Vibro-Contact Analysis of Ultrasonic Atomic Force Microscopy Tip and It's Application to Nano Surface (UAFM(초음파원자현미경) 팁의 진동-접촉 해석과 나노 표면에의 응용)

  • Park, Tae-Sung;Kwak, Dong-Ryul;Park, Ik-Keun;Kim, Chung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.2
    • /
    • pp.132-138
    • /
    • 2010
  • Vibro-contact of cantilever tip is studied with respect to contact mechanics and an elastic characteristic of nanoscale surface is imaged. The contact resonance frequency is calculated theoretically using the spring-mass and Herzian models, and the variation of resonance frequency of cantilever was analyzed when the cantilever was free and contact. The elasticity imaging was also achieved successfully using phase and amplitude signals obtained from the spheroidized steel specimens by prototype ultrasonic AFM.

Research on Thermal Refocusing System of High-resolution Space Camera

  • Li, Weiyan;Lv, Qunbo;Wang, Jianwei;Zhao, Na;Tan, Zheng;Pei, Linlin
    • Current Optics and Photonics
    • /
    • v.6 no.1
    • /
    • pp.69-78
    • /
    • 2022
  • A high-resolution camera is a precise optical system. Its vibrations during transportation and launch, together with changes in temperature and gravity field in orbit, lead to different degrees of defocus of the camera. Thermal refocusing is one of the solutions to the problems related to in-orbit defocusing, but there are few relevant thermal refocusing mathematical models for systematic analysis and research. Therefore, to further research thermal refocusing systems by using the development of a high-resolution micro-nano satellite (CX6-02) super-resolution camera as an example, we established a thermal refocusing mathematical model based on the thermal elasticity theory on the basis of the secondary mirror position. The detailed design of the thermal refocusing system was carried out under the guidance of the mathematical model. Through optical-mechanical-thermal integration analysis and Zernike polynomial calculation, we found that the data error obtained was about 1%, and deformation in the secondary mirror surface conformed to the optical index, indicating the accuracy and reliability of the thermal refocusing mathematical model. In the final ground test, the thermal vacuum experimental verification data and in-orbit imaging results showed that the thermal refocusing system is consistent with the experimental data, and the performance is stable, which provides theoretical and technical support for the future development of a thermal refocusing space camera.

Imaging Findings of Breast Metastasis from Malignant Peripheral Nerve Sheath Tumor of Mediastinum: A Case Report (종격동 악성 말초 신경 초종으로부터 유방 전이의 영상 소견: 증례 보고)

  • So Hyeong Park;Ji Yeon Park;Mee Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.770-775
    • /
    • 2023
  • Malignant peripheral nerve sheath tumor (MPNST), a rare soft-tissue sarcoma, is most commonly located in the trunk, extremities, and head and neck, but rare in the breast. We report a metastatic breast MPNST in a 27-year-old woman with neurofibromatosis type 1 (NF-1). Chest computed tomography revealed a well-defined, oval, mildly enhancing nodule in the right breast. US revealed a circumscribed, oval, heterogeneous echoic mass with vascularity and intermediate elasticity in the right upper outer breast. The breast mass was excised and diagnosed as MPNST on histopathology evaluation. Although rare, it should be included in the differential diagnosis of breast mass in NF-1 patient.

Conventional Ultrasonography and Real Time Ultrasound Elastography in the Differential Diagnosis of Degenerating Cystic Thyroid Nodules Mimicking Malignancy and Papillary Thyroid Carcinomas

  • Wu, Hong-Xun;Zhang, Bing-Jie;Wang, Jun;Zhu, Bei-Lin;Zang, Ya-Ping;Cao, Yue-Long
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.2
    • /
    • pp.935-940
    • /
    • 2013
  • Background: To evaluate the diagnostic utility of conventional ultrasonography and real time ultrasound elastography in differentiating degenerating cystic thyroid nodules mimicking malignancy from papillary thyroid carcinoma. Methods: We retrospectively analyzed conventional ultrasonographic and elastographic characteristics of 19 degenerating cystic thyroid nodules mimicking malignancy in 19 patients, with 30 surgically confirmed PTCs as controls. Based on size, the nodules had been grouped into less than 10mm (group A) and greater than 10 mm (group B). We evaluated conventional parameters and elasticity pattern. Color-scaled elastograms were graded as to stiffness of nodules using an elasticity pattern from I (soft) to IV (stiff). Results: Degenerating cystic thyroid nodules were similar to PTCs in conventional ultrasonographic findings, but the former frequently showed oval to round in shape (group A, 69.2% vs 18.8%, P=0.017; group B, 66.7% vs 7.14%, P=0.017) and punctuate hyperechoic foci (group A, 61.5% vs 0, P<0.001; group B, 50% vs 0, P<0.001). On real time ultrasound elastography, 7 of 13 degenerating cystic thyroid nodules in group A were pattern I, 5 were pattern II, 1 was pattern III. One degenerating cystic thyroid nodule in group B was pattern II, 5 were pattern III. The area under the curve for elastography was 0.98 in group A (sensitivity 92.3%, specificity 100%, P = 0.002), and 0.88 in group B (sensitivity 16.7%, specificity 100%, P = 0.014). Conclusions: As a dependable imaging technique, elastography helps increase the performance in differential diagnosis of degenerating cystic thyroid nodule and malignancy.

Comparison of Shear Wave Elastography and Pathologic Results Using BI - RADS Category for Breast Mass (유방종괴에 대한 BI-RADS범주를 이용한 횡탄성 초음파와 병리결과 비교분석)

  • An, Hyun;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.217-223
    • /
    • 2018
  • This study to search the diagnostic performance of shear wave elastography(SWE) in breast mass and to compare the biopsy result and stiffness obtained from shear wave elastography. Diagnostic breast ultrasonography and SWE were targeted for 157 patients who had breast ultrasonography was diagnosed mass from June 2017 to September 2017. Pathology results of 157 patients showed a benign 92 patients(Age, $44.54{\pm}11.84$) and a malignancy 65 patients(Age, $51.55{\pm}10.54$). Final evaluation, biopsy result, and quantitative SWE result were obtained and compared with each other according to Breast Imaging Reporting and Data System(BI-RADS) of diagnostic breast ultrasonography. Quantitative SWE value and pathologic result showed the highest diagnostic specificity of 83.70% in Emean and sensitivity of 89.23% in Emin. Quantitative SWE result and biopsy result is statistically significant.(p=0.000). The optimal cut-off value for malignant lesions was 66.3 kPa and 63.7 kPa, respectively, for the sensitivity, specificity, high maximum mean elasticity value(Emax) and mean elasticity value(Emean) and this showed the highest diagnostic area under the ROC curve(Az) value compared to other SWE measurement(p=0.000). The addition of SWE to conventional US in breast mass make a increase diagnostic specificity and reduce unnecessary biopsy. Therefore, it is expected that it will be helpful to analyze the breast mass using the above analysis and apparatus.

The Effect of $Sa-Am$ Lung Sedating Acupuncture on Wrist Pulse in Healthy Human Subjects (폐승격(肺勝格) 자침이 촌관척(寸關尺) 맥파변화에 미치는 영향)

  • Kim, Seok-Joo;Lee, Hyun
    • Journal of Acupuncture Research
    • /
    • v.29 no.2
    • /
    • pp.43-57
    • /
    • 2012
  • Objectives : The purpose of this study is to observe the effects of $Sa-Am$ lung sedating acupuncture (LS) on wrist pulse changes in healthy participants. Method : Forty healthy subjects participated in this study, and were divided into an acupuncture group and controlled group. Using a three-dimensional pulse imaging system (DMP-3000), wrist pulse was measured before, immediately after, 30 minutes after and 60 minutes after acupuncture in the acupuncture group, with the rest in controlled group. Sixteen parameters between the acupuncture group and the controlled group were analyzed at Cun, Guan and Chi in each time. Result : After LS acupuncture, wrist pulse sixteen parameters were changed significantly according to the time at each measuring region. 1. Heart rate significantly decreased in immediately after, 30 minutes after and 60 minutes after, Pulse period significantly increased in 30 minutes after and 60 minutes after. 2. T4 didn't significantly changed, T-T4 significantly increased in immediately after, 30 minutes after and 60 minutes after. T4/T, T4/(T-T4), T1/T, T5/T significantly decreased in immediately after, 30 minutes after and 60 minutes after. (T-T4)/T significantly decreased in immediately after, 30 minutes after and 60 minutes after. T5 significantly increased in 30 minutes after and 60 minutes after. 3. Modulus of elasticity significantly decreased in left Cun 60 minutes after, significantly increased in left Chi 30 minutes after. 4. Variance of Amplitude significantly increased in right Guan 60 minutes after. 5. Area of pulse significantly increased in left Cun 60 minutes after, left Chi 30 minutes after and right Cun 60 minutes after. Systolic pulse area significantly decreased left Chi 30 minutes after, right Cun immediately after, 30 minutes after and 60 minutes after, right Guan in immediately after. 6. Energy/min significantly decreased in left Chi 60 minutes after and right Cun immediately after. EIx significantly decreased in right Cun immediately after. 7. In both sides Cun, Guan, Chi wrist pulse, a lot of significant changes in right Cun and left Chi appeared, and then followed by the left Cun, right Guan. Conclusion : This study analyzed that the correlation between LS acupuncture and radial pulse(cun, guan, chi) is considered to be meaningful, hereafter clinical studies on this are needed.

Differences in the Length Change Pattern of the Medial Gastrocnemius Muscle-Tendon Complex and Fascicle during Gait and One-legged and Two-legged Vertical Jumping (보행과 한발·두발 수직점프 수행 시 내측비복근 근-건 복합체와 근섬유다발의 길이 변화 패턴의 차이)

  • Lee, Hae-Dong;Han, Bo-Ram;Kim, Jin-Sun;Oh, Jeong-Hoon;Cho, Han-Yeop;Yoon, So-Ya
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.2
    • /
    • pp.175-182
    • /
    • 2015
  • Objective : The purpose of this study was to investigate difference in fascicle behavior of the medial gastrocnemius during the locomotion with varying intensities, such as gait and one-legged and two-legged vertical jumping. Methods : Six subjects (3 males and 3 females; age: $27.2{\pm}1.6yrs.$, body mass: $62.8{\pm}9.8kg$, height: $169.6{\pm}8.5cm$) performed normal gait (G) at preferred speed and maximum vertical jumping with one (OJ) and two (TJ) legs. While subjects were performing the given tasks, the hip, knee and ankle joint motion and ground reaction force was monitored using a 8-infrared camera motion analysis system with two forceplates. Simultaneously, electromyography of the triceps surae muscles, and the fascicle length of the medial gastrocnemius were recorded using a real-time ultrasound imaging machine. Results : Comparing to gait, the kinematic and kinetic parameters of TJ and OJ were found to be significantly different. Along with those parameters, change in the medial gastrocnemius (MG) muscle-tendon complex (MTC) length ($50.57{\pm}6.20mm$ for TJ and $44.14{\pm}5.39mm$ for OJ) and changes in the fascicle length of the MG ($18.97{\pm}3.58mm$ for TJ and $20.31{\pm}4.59mm$ for OJ) were observed. Although the total excursion of the MTC and the MG fascicle length during the two types of jump were not significantly different, however the pattern of length changes were found to be different. For TJ, the fascicle length maintained isometric longer during the propulsive phase than OJ. Conclusion : One-legged and two-legged vertical jumping use different muscle-tendon interaction strategies.

Relationship between Muscle Strength and Tendon Stiffness of the Ankle Plantarflexors and Its functional Consequence (인체 족저굴곡근의 근력과 아킬레스 건의 경도, 기능적 능력 간 상관관계 분석)

  • Han, Seong-Won;Lee, Dae-Yeon;Lee, Hae-Dong
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.1
    • /
    • pp.35-42
    • /
    • 2014
  • Tendon elasticity is an important factor affecting muscle function and thus human movements. It has been reported that the mechanical properties of tendon are adaptable to external loading condition. Based on the adaptability of muscle and tendon to external loading conditions, one can assume that there might be an optimum ratio between muscle strength and tendon stiffness. The present study aimed to investigate whether there is correlation between plantar flexor muscle strength and stiffness of the achilles tendon (AT). Twenty two male subjects (age: $23.2{\pm}1.5yrs$, height: $175.5{\pm}6.2cm$, weight: $75.4{\pm}9.8kg$) performed maximum voluntary isometric plantarflexion on a custom-built dynamometer and muscle-tendon junction of the medial gastrocnemius muscle was simultaneously monitored using a real-time ultrasound imaging machine. The averages of muscle force and tendon stiffness were $366.38{\pm}79.37N$, $35.34{\pm}10.42N/mm$, respectively. Significant positive correlation was observed between muscle strength and tendon stiffness (r=0.8507), indicating that the muscle force is proportional to tendon stiffness. The results might have been used in computational modeling and criterion of training progress level in the fields of training and rehabilitation.

The Effect of Sa-Am Lung Tonifying Acupuncture on Radial Pulse in Healthy Human Subjects (폐정격(肺正格) 자침이 촌관척(寸關尺) 맥파 변화에 미치는 영향)

  • Kim, Na-Yeon;Kang, Jae-Hui;Lee, Hyun
    • Journal of Acupuncture Research
    • /
    • v.29 no.5
    • /
    • pp.17-29
    • /
    • 2012
  • Objectives : The purpose of this study is to find the effects of Sa-Am lung tonifying acupuncture on radial pulse through the parameters difference. Methods : Forty healthy subjects participated in this study, acupuncture group and control group were divided. Compared various parameters of radial pulse between two groups, and the significantly changed 16 parameters ware measured using 3 dimensional pulse imaging system(DMP-3000) before, right after, 30 minutes after, and 60 minutes after acupuncture at Chon, Gwan, Cheok in acupucture group. Results : After lung tonifying acupuncture, radial pulse 16 parameters were showed changes significantly according to the time at each measuring location. 1. Heart rate, T2/T, T5, T5/T and W/T significantly decreased, W significantly increased. 2. Modulus of elasticity significantly decreased in left Cheok. 3. Amplitude of H4 significantly increased in left Gwan and right Cheok. 4. AIx, AIxHR significantly decreased in left Gwan and significantly increased in right Chon. 5. Area of pulse, area of W significantly increased in right Cheok. 6. Pulse energy, energy/min, EIx significantly decreased in left Cheok. 7. Maximum variation time of each parameter is showed different according to the parameter. Conclusions : Lung tonifying acupuncture exerts an influence on radial purse parameters. Further radial pulse change study on various acupuncture treatment is required.

The role of internal architecture in producing high-strength 3D printed cobalt-chromium objects

  • Abdullah Jasim Mohammed;Ahmed Asim Al-Ali
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.2
    • /
    • pp.91-104
    • /
    • 2024
  • PURPOSE. The objectives of the current study were to estimate the influence of self-reinforced hollow structures with a graded density on the dimensional accuracy, weight, and mechanical properties of Co-Cr objects printed with the direct metal laser sintering (DMLS) technique. MATERIALS AND METHODS. Sixty-five dog-bone samples were manufactured to evaluate the dimensional accuracy of printing, weight, and tensile properties of DMLS printed Co-Cr. They were divided into Group 1 (control) (n = 5), Group 2, 3, and 4 with incorporated hollow structures based on (spherical, elliptical, and diamond) shapes; they were subdivided into subgroups (n = 5) according to the volumetric reduction (10%, 15%, 20% and 25%). Radiographic imaging and microscopic analysis of the fractographs were conducted to validate the created geometries; the dimensional accuracy, weight, yield tensile strength, and modulus of elasticity were calculated. The data were estimated by one-way ANOVA and Duncan's tests at P < .05. RESULTS. The accuracy test showed an insignificant difference in the x, y, z directions in all printed groups. The weight was significantly reduced proportionally to the reduced volume fraction. The yield strength and elastic modulus of the control group and Group 2 at 10% volume reduction were comparable and significantly higher than the other subgroups. CONCLUSION. The printing accuracy was not affected by the presence or type of the hollow geometry. The weight of Group 2 at 10% reduction was significantly lower than that of the control group. The yield strength and elastic modulus of the Group 2 at a 10% reduction showed means equivalent to the compact objects and were significantly higher than other subgroups.