• Title/Summary/Keyword: Elastic restoring force

Search Result 21, Processing Time 0.027 seconds

Experimental study on pullout capacity on friction type steel pipe rock bolt to use elastic restoring force and existing rock bolts (탄성복원력을 이용한 마찰형 강관 록볼트 및 기존 록볼트에 대한 인발력 실험연구)

  • Moorak Son;Jihyun Kim
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.6
    • /
    • pp.459-468
    • /
    • 2023
  • In this study, an experiment on pullout capacity was conducted of rock bolts using grouting materials such as cement mortar and resin, which are widely used, and a newly proposed steel pipe friction type rock bolt using elastic restoring force, and the results were compared and analyzed. The experimental results showed that the pullout capacity on the rock bolts with cement mortar under a dry condition (no ground water) was relatively larger than the rock bolts with resin and the steel pipe. Nevertheless, the friction type steel pipe rock bolt to use elastic restoring force is expected to be useful in the field particularly where groundwater exists and it affects the loss and curing of grouting materials such as cement mortar or resin. In addition, it was found to have the advantage of being easy and quick to install.

A Study on the Nonlinear Restoring Force Characteristics for Shear Wall Structures by JEAC 4601 (JEAC 4601에 의한 전단벽 구조물의 비선형 복원력 특성에 대한 고찰)

  • Lee, Won Hun;Kim, Hee Kyun;Song, Sung Bin;Hwang, Kee Tae
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.25 no.3
    • /
    • pp.121-128
    • /
    • 2021
  • Structures of domestic nuclear power plants are designed to perform elastic behavior against beyond design earthquakes, but studies on the nonlinear behavior of structures have been insufficient since the beyond design earthquake. Accordingly, it is judged that it will be necessary to develop an evaluation method that considers the nonlinear behavioral characteristics to check the safety margin for a standard nuclear power plant structure. It is confirmed that the restoring force characteristics for each member level can be identified through the calculation formula, and the lateral stiffness for each story can also be easily calculated by JEAC 4601. In addition, as a result of applying the evaluation method of JEAC 4601 as a nonlinear restoring force model of the nuclear power plant, a certain degree of safety margin can be identified.

Studies on restoring force model of concrete filled steel tubular laced column to composite box-beam connections

  • Huang, Zhi;Jiang, Li-Zhong;Zhou, Wang-Bao;Chen, Shan
    • Steel and Composite Structures
    • /
    • v.22 no.6
    • /
    • pp.1217-1238
    • /
    • 2016
  • Mega composite structure systems have been widely used in high rise buildings in China. Compared to other structures, this type of composite structure systems has a larger cross-section with less weight. Concrete filled steel tubular (CFST) laced column to box-beam connections are gaining popularity, in particular for the mega composite structure system in high rise buildings. To enable a better understanding of the destruction characteristics and aseismic performance of these connections, three different connection types of specimens including single-limb bracing, cross bracing and diaphragms for core area of connections were tested under low cyclic and reciprocating loading. Hysteresis curves and skeleton curves were obtained from cyclic loading tests under axial loading. Based on these tested curves, a new trilinear hysteretic restoring force model considering rigidity degradation is proposed for CFST laced column to box-beam connections in a mega composite structure system, including a trilinear skeleton model based on calculation, law of stiffness degradation and hysteresis rules. The trilinear hysteretic restoring force model is compared with the experimental results. The experimental data shows that the new hysteretic restoring force model tallies with the test curves well and can be referenced for elastic-plastic seismic analysis of CFST laced column to composite box-beam connection in a mega composite structure system.

Analysis of hysteresis rule of energy-saving block and invisible multi-ribbed frame composite wall

  • Lin, Qiang;Li, Sheng-cai;Zhu, Yongfu
    • Structural Engineering and Mechanics
    • /
    • v.77 no.2
    • /
    • pp.261-272
    • /
    • 2021
  • The energy-saving block and invisible multi-ribbed frame composite wall (EBIMFCW) is a new type of load-bearing wall. The study of this paper focus on it is hysteresis rule under horizontal cyclic loading. Firstly, based on the experimental data of the twelve specimens under horizontal cyclic loading, the influence of two important parameters of axial compression ratio and shear-span ratio on the restoring force model was analyzed. Secondly, a tetra-linear restoring force model considering four feature points and the degradation law of unloading stiffness was established by combining theoretical analysis and regression analysis of experimental data, and the theoretical formula of the peak load of the EBIMFCW was derived. Finally, the hysteretic path of the restoring force model was determined by analyzing the hysteresis characteristics of the typical hysteresis loop. The results show that the curves calculated by the tetra-linear restoring force model in this paper agree well with the experimental curves, especially the calculated values of the peak load of the wall are very close to the experimental values, which can provide a reference for the elastic-plastic analysis of the EBIMFCW.

A Study on Mechanical Properties of Acrylonitrile Butadiene Rubber Composites

  • Jung, Eugene;Pyo, Kyeong-Deok;Park, Cha-Cheol
    • Elastomers and Composites
    • /
    • v.52 no.4
    • /
    • pp.280-286
    • /
    • 2017
  • The mechanical and dynamic properties according to the content of filler, plasticizer, and crosslinking agent of rubber composites for Lipseal were measured in this study. The mechanical properties of the composite including the silane coupling agent and silica were found to be superior to those of the composite containing carbon black. It was found that the rebound resilience characteristics were influenced by the crosslink density of sulfur rather than the filler or plasticizer. In the case of recovery, it was confirmed that the elastic restoring force improved in the compression deformation condition and recovery increased as the crosslinking density increased. The rubber composite for Lipseal of this study is expected to improve the manufacturing technology of the rubber composite which can implement the optimum function for recognizing the performance such as oil resistance, durability and compression set.

Microfluidic Suction Pump based on Restoring Force of Elastomer for Liquid Transportation in Microfluidic System (미세유체시스템의 유체이송을 위한 탄성체의 복원력을 이용한 흡입형 미세유체펌프)

  • Byun, Kang Il;Han, Eui Don;Kim, Byeong Hee;Seo, Young Ho
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.1
    • /
    • pp.81-86
    • /
    • 2015
  • This paper presents a disposable passive suction pump that uses the restoring force of an elastomeric chamber for liquid transportation in a microfluidic system. The proposed suction pump can be operated by finger pressure without any peripheral equipment. To adjust the generated suction pressure, five different displacements of the suction chamber ceiling, two different chamber shapes, and five different elastic moduli of the elastomer were considered. For a cylindrical chamber with a 5 mm height and 5 mm radius, the generated suction pressure and flow rate increased almost linearly up to about 31 kPa and $160.8{\mu}L/min$, respectively, depending on the chamber deformation. A maximum suction pressure of $42.9{\pm}0.7kPa$ was obtained for a hemispherical chamber with a 2.1 mm height and 5 mm radius.

MODEL ON THE DYNAMIC BEHAVIOR OF CONDUCTIVE FERROMAGNETIC MATERIAL WITH NEGLIGIBLE COERCIVITY

  • Kim, Dac-Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.790-794
    • /
    • 1995
  • Differential equations governing dynamic behavior of toroid-shaped ferro-magnetic material having a small gap of uniform width were derived incorporating Maxwell equations of electromagnetic induction relevent to the system and Newtonian equation of motion. Once the external uniform magnetic field was applied within the material through dc-circuit around the toroid, gap begin to change which lead to the abrupt variation of field in the material and gap according to the differential equations already derived. Characteristics of current and electromotive force with respect to time in the circuit consisting of inductance and resistance in series could be predicted from numerical solutions of these equations. As current in the circuit increasesl, magnetic field in the material increases, thus, the gap starts to shrink due to increased attractive force between gap and elastic restoring force in the material. With an appropriate selection of elastic constant of toroidal ferromagnetic material and design of gap structure it is possible to obtain the specified in both linear and nonlinear magnetic characteristics, such as current dependent and independent inductance.

  • PDF

PERIODIC OSCILLATIONS OF A PARTICLE NONLINEARLY SUPPORTED FROM TWO POINTS

  • Oh, Hye-Young
    • Journal of applied mathematics & informatics
    • /
    • v.8 no.2
    • /
    • pp.613-625
    • /
    • 2001
  • In this paper, we investigate a simplified model of a particle suspended elastically from two towers by two nonlinear elastic springs, with a restoring force similar to Hooke’s law under extension and with no resistance to compression. Numerical results are presented, showing the solutions can be either of the same period oscillation the forcing term, can be a subharmonic response of multiple period, or can be noisy periodic which is apparently chaotic. Multiplicity of periodic solutions for certain physical parameters are demonstrated.

Dynamic Stability Analysis of Base-Isolated Low-level Nonlinear Structure Under Earthquake Excitation (지진시 저층건물 면진구조의 비선형 동적 거동)

  • Mun, Byeong-Yeong;Gang, Gyeong-Ju;Gang, Beom-Su;Kim, Gye-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.11
    • /
    • pp.1743-1750
    • /
    • 2001
  • This paper presents an analysis of nonlinear response of the seismically isolated structure against earthquake excitation to evaluate isolation performances of a rubber bearing. In the analysis of the vibration of building, the building is modeled by lumped mass system where the restoring force is considered as linear, bilinear and trilinear. Fundamental equations of motion are derived for the base isolated structure, and hysteretic and nonlinear-elastic characteristics are considered for a numerical calculation. The excitation levels are magnified fur the recorded strong earthquake motions in order to examine dynamic stability of the structure. Seismic responses (of the building are compared fur the each restoring force type. As a result, it is shown that the effect of the motion by the nonlinear response of the building is comparatively not so large from a seismic design standpoint. The responses of the isolated structures reduce sufficiently and controled the motion of the building well in a practical range. By increasing the acceleration of the earthquake, the yielding of the farce was occurred in the concrete and steel frame, which shows the necessity of the exact nonlinear dynamic analysis.

Compliant Micro Actuator made from Dielectric Polymer

  • Sunghwi Cho;Sungmoo Ryew;Jeon, Jae-Wook;Kim, Hunmo;Nam, Jae-Do;Park, Hyoukryeol;Ryutaro Maeda
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.103.2-103
    • /
    • 2001
  • In this paper, we discusses compliant actuators those are made of electrostrictive polymer. Electrostrictive polymer actuators(EPAs) are based on the deformation of dielectric elastomer polymer in the presence of an electric field. We address actual design and fabrication method of an actuator using the electrostrictive polymer. We have developed primitive prototypes of the actuator using elastic restoring force. And they actuators have 1 to 3 DOF, 1 DOF actuators are simple linear actuators and 3 DOF actuator has linear actuation and steering capability. They are simple in structure with lightweight, high trust, force and large stroke. Basic design principles and experimental procedures for confirming their performance will be introduced.

  • PDF