• 제목/요약/키워드: Elastic Recoil

검색결과 27건 처리시간 0.035초

유한요소법을 이용한 스텐트의 기계적 성능 비교 및 평가 (Using Finite Element Analysis for Mechanical Properties of Coronary Stents)

  • 조승관;김한성;이상헌;탁계래;탁승제
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1306-1309
    • /
    • 2003
  • In the present paper, finite element analyses were carried out to evaluate the most important feature of a stent, that is. high radial strength and flexibility. Palmaz-Schatz 154 stent and two new models(stent A, stent B) were selected because they are the most representatives of tubular stents. Finite element analyses for the stent system were performed using ABAQUS/Explicit code. As a result, Palmaz-Schatz 154 stent shows sufficient radial strength but it needs some improvement in general properties such as high flexibility, low elastic recoil, low longitudinal contraction and low metal coverage area. Other two models show that sufficient flexibility, foreshortening and longitudinal recoil.

  • PDF

산란-되튐 동시 측정 방법에 의한 박막 중 수소 정량법 (Quantitative analysis of hydrogen in thin film by scattering-recoil co-measurement technique)

  • 이화련;음철헌;최한우;김준곤
    • 분석과학
    • /
    • 제19권5호
    • /
    • pp.400-406
    • /
    • 2006
  • 탄성되튐검출(Elastic Recoil Detection)법에 의한 박막시료의 수소 정량은 빔전류 측정의 신뢰성을 전제로 유기물 필름을 정량 비교체로 사용하여 이루어진다. 그러나 탄성되튐검출법에서 일반적으로 사용되는 편향각(tilt angle)인 $75^{\circ}$에서는 시편에 조사되는 일차 이온빔의 조사량을 정확하게 측정하기 어렵다. 시편의 편향각을 바꿔가며 탄성산란 신호를 비교하면 편향각이 커질수록 단위 조사량 당 산란신호는 감소하며 또한 시편의 표면 물질에 따라 이온빔전류 적산의 효율이 달라진다. 이러한 빔전류 적산과정의 오류를 제거하여 정량의 신뢰성을 제고하는 방법으로 되튐스펙트럼과 동시에 측정한 산란스펙트럼을 이용하여 빔 조사량을 결정하였다. 산란스펙트럼에 의한 조사량 결정법은 수 10%에 이르는 전류적산과정의 오차요인을 근본적으로 제거하여 되튐반응에 의한 수소정량의 신뢰성을 향상시켰다. 수소정량의 비교체로 사용해 왔던 폴리이미드 필름과 수소이온주입 시료, 그리고 카본웨이퍼를 대상으로 시험분석하고 기존의 전류적산에 의한 직접정량법과 비교하였다.

유한요소 해석을 이용한 스텐트 최적형상 설계 (A Study on Optimal Shape of Stent by Finite Element Analysis)

  • 이태현;양철호
    • 한국산학기술학회논문지
    • /
    • 제18권11호
    • /
    • pp.1-6
    • /
    • 2017
  • 스텐트는 인체의 좁아지거나 막힌 부위에 삽입되어 혈류의 흐름을 정상화 시키는데 사용되는 금속망 형태의 임플란트로 관상 동맥 질환을 치료하는데 가장 일반적인 방법으로 널리 사용된다. 본 논문에서는 유한요소 해석과 다꾸지 방법을 이용하여 설정한 스텐트 설계 인자의 변화에 따른 기계적 반응을 고찰하였다. 스텐트 모델은 팔마즈 스텐트를 사용하였고 스텐트의 재료 모델로서는 탄소성 모델, 풍선은 초탄성 모델을 사용하였다. 연구의주요 관심은 스텐트의 탄성 회복량 조절을 통한 혈관의 재 협착 문제를 감소시킬 수 있는 방안에 대한 설계 인자의 영향을 고찰하는데 있다. 스텐트 두께, 슬롯의 가로 길이, 슬롯의 세로 길이의 각도를 설계인자로 선택하여 직교배열표를 구성하였다. 유한요소 해석을 이용하여 혈관 내 스텐트의 반경 방향 탄성회복율과 길이 방향 탄성회복율을 계산하였고 다구찌 기법을 이용한 통계적 분석을 하여 재 협착의 가능성을 감소시킬 수 있는 스텐트의 최적 형상 설계 방향을 제시하였다. 최적형상은 기본 모델에 비하여 탄성회복율은 반경방향으로 약 1%, 길이방향으로 약 0.1% 감소함을 보였다.

지면의 종류와 숙련도에 따른 필라테스 티져(Teaser)동작의 코어안정화와 근육 균형의 차이 (Difference in Core Stability and Muscle Balance of the Pilates Teaser Motion According to Kinds of the Ground and Skills)

  • 신윤경;이경옥
    • 한국운동역학회지
    • /
    • 제25권1호
    • /
    • pp.65-76
    • /
    • 2015
  • Objective : The purpose of this study was to analyse the differences in core stability and muscle balance of the pilates Teaser motion according to the surfaces and skills. Methods : There were 10 subjects in this study with 5 being skilled and 5 that were not skilled. The independent variables were surfaces (high elastic & aluminum) and skills (skilled & unskilled). Dependent variables were core stability and muscle balance. Core stability was measured by Force Platform (9872, Switzerland), 3D Imagery (IBS-2000, EXYMA) was used to understand the muscle balance. In order to do the Teaser movement subjects had to lay flat on their back and then lean forward as much as possible and hold the position for 10 seconds. Afterwards, they would lay back down again. A camera (MHS-PM5K, SONY) was used to make 4 phases (take off, recoil forward, holding, recoil backward) during the teaser exercise to analyze movement. In this study quantitative and qualitative analysis was used. For the statistical analysis, 2X2 ANOVA was used to analyze the differences in movement time, X,Y,Z maximum force, center of pressure and angles according to different phases. 2X3 ANOVA was used to analyze the differences in muscle balance via SPSS 18.0. Results : Soft. Elastic mat had a longer holding time, lower Fx/ Fy/ Fz, shorter Fx trajectory, larger angle and shorter gaps in muscle balance than a hard surface in skilled subjects. This was because the mat can help to recruit and then sustain core fine muscles during holding time in the Teaser movement.

Passivation Properties of Hydrogenated Silicon Nitrides deposited by PECVD

  • Kim, Jae Eun;Lee, Kyung Dong;Kang, Yoonmook;Lee, Hae-Seok;kim, Donghwan
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.334.2-334.2
    • /
    • 2016
  • Silicon nitride (SiNx:H) films are generally used as passivation layer on solar cell and they are usually made by plasma enhanced chemical vapor deposition (PECVD). In this study, we investigated the properties of silicon nitride (SiNx:H) films made by PECVD. Effects of mixture ratio of process gases with silane (SiH4) and ammonia (NH3) on the passivation qualities of silicon nitride film are evaluated. Passivation properties of SiNx:H are focused by making antireflection properties identical with thickness and refractive index controlled. The absorption coefficient of each film was evaluated by spectrometric ellipsometery and the minority carrier lifetimes were evaluated by quasi-steady-state photo-conductance (QSSPC) measurement. The optical properties were obtained by UV-visible spectrophotometer. The interface properties were measured by capacitance-voltage (C-V) measurement and the film components were identified by Fourier transform infrared spectroscopy (FT-IR) and Rutherford backscattering spectroscopy detection (RBS) - elastic recoil detection (ERD).

  • PDF

완충시스템을 장착한 고충격 발생기구의 동특성 해석 및 실험 (Dynamic Analysis and Experiments of High Impulsive Force Device with Isolation System)

  • 박문선;강태호;변영섭;송준범;구태완;강범수
    • 한국정밀공학회지
    • /
    • 제25권10호
    • /
    • pp.107-114
    • /
    • 2008
  • The aim of this study is to obtain the useful design guideline for high impulsive force device with an isolation system by the analytic approach of dynamics characteristics. In this study, the high impulsive force system was modeled and analyzed in view of multi-body dynamics, and verified the modeling and analysis result by the experiment of the high impulsive force device. Additionally, the dynamic analysis was performed for the isolation system with the selected coefficients of elastic spring and damper selected. Experimental result for the high impulsive force device with the isolation system was compared and analyzed. From the result, it was confirmed that the design guideline for the isolation system of the high impulsive force device was useful.

Comparison of Light Output from NE213 for Electrons and Protons

  • Shin, Hyun-Kook;Koh, Byung-Joon
    • Nuclear Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.111-117
    • /
    • 1979
  • Time of flight Technique를 사용한 coincidence spectrometer에 의해 액체 형광물질(liquid scintillator) NE213의 전자와 양자에 대한 빛 방출량을 측정하였다. 이 실험에서 양자에너지 (3.2Mev, 4Mev, 5Mev, 6Mev)는 2Mev에서 9Mev에 이르는 여러 에너지 분포를 갖고 있는 Am.Be 중성자원을 사용하여 중성자 탄성산란의 각도(45$^{\circ}$ and 60$^{\circ}$)와 측정기간의 거리를 조절하므로서 얻었다. NE213액체발광물질의 빛 방출량은 전자 에너지에 대해 선형적인 응답을 보였으며 양자에 대한 응답은 에너지 증가에 따라 비선형적이었다. 빛의 세기도 전자에 의한 응답이 양자에 의한 것보다 약 세배 가랑 컸다. 본 실험결과는 Batchelor et at 이 발표한 실험결과와 거의 비슷했다.

  • PDF

만성폐쇄성폐질환의 병태생리 (Pathophysiology of Chronic Obstructive Pulmonary Disease)

  • 김현국;이상도
    • Tuberculosis and Respiratory Diseases
    • /
    • 제59권1호
    • /
    • pp.5-13
    • /
    • 2005
  • COPD는 비가역적인 기류제한을 특징으로 하는 질병의 상태이다. 이러한 기류제한은 유해입자나 가스등에 대한 폐의 비정상적인 염증반응과 관련되어 있고 자연경과 중 지속적으로 진행하는 양상을 띤다. 비정상적인 염증반응 및 단백분해효소와 항단백분해효소간의 불균형과 산화 스트레스 등의 기전에 의해 점액의 과분비, 섬모의 기능장애, 소기도의 섬유화와 협착, 폐실질의 파괴, 폐혈관손상 등이 발생한다. 이러한 병리학적 변화에 의해 기류제한이 발생하고 가스교환 장애, 폐고혈압, 폐성심, 전신적인 염증이나 골격근의 기능장애 등이 유발된다. COPD 환자의 일반적인 증상인 기침, 객담, 호흡곤란 등은 이러한 병태생리학적 변화로 설명할 수 있다.

비정질 탄소막 (a-C:H) 내에 존재하는 수소에 관한 연구

  • 박노길;박형국;손영호;정재인
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1999년도 제17회 학술발표회 논문개요집
    • /
    • pp.133-133
    • /
    • 1999
  • 비정질 탄소막 제조에 있어서 수소가 포함된 반응성 가스를 사용할 경우 제작된 탄소막 내부에는 수소가 포함되게 되며, 이러한 수소원자들은 막의 특성에 중요한 영향을 주는 것으로 알려져 있다. 따라서, 본 연구에서는 비정질 탄소막(a-C:H) 내부에 존재하는 수소가 탄소막의 특성에 미치는 영향을 알아보고, 막 내부에 포함된 수소의 함량과 공정조건 사이의 함수계를 조사함으로써 수소의 함량을 인위적으로 통제할 수 있는 가능성을 제시하고자 한다. 수소가 포함된 비정질 탄소막은 2.45 GHz의 전자기파를 사용하는 electron cyclotron resonance plasma enhanced chemical vapor deposition (ECR-PECVD) 방법과 DC magnetron sputtering 법을 사용하여 제작하였다. 기판으로는 Si(001) wafer를 사용하였으며, 아세톤과 에탄올을 사용하여 표면의 유기성분을 제거하고, 진공챔버속에서 Ar 플라즈마를 발생시켜 sputter etching 방법으로 표면을 세척하였다. ECR-PECVD 방법에서는 반응가스로 메탄(CH4)과 수소(H2)의 혼합가스를 사용하였으며, 혼합가스의 비는 5~50% 범위내에서 변화를 주었다. 수소가스의 유량은 100SCCM으로 고정하였으며, 마이크로웨이브의 power는 360~900W였고, 기판에 가해준 negative DC bias 전압은 0~-500V이었다. DC magnetron sputtering 방법에서는 반응가스로 아세틸린(C2H2) 가스를 사용하였으며, 플라즈마 발생을 용이하게 하기 위해서 Ar 가스와 혼합하여 사용하였다. Ar 가스의 유량은 10SCCM으로 고정하였으며, 아세틸렌 가스의 유량은 5~20SCCM 범위내에서 주입하였다. 이때, 기판에 가해준 negative DC bias 전압은 0~-100V이었다. 제작된 탄소막의 수소 함량을 조사하기 위하여 Fourier Transform Infrared (FTIR) 분광법과 Elastic Recoil Detection Analysis (EFDA) 법을 사용하였으며, 증착율은 SEM 단면촬영과 a-step을 이용하여 측정하였고, 막의 경도는 Micro-Hardness Testing 법을 사용하여 측정하였다.

  • PDF