• Title/Summary/Keyword: Elastic Recoil

Search Result 27, Processing Time 0.029 seconds

Using Finite Element Analysis for Mechanical Properties of Coronary Stents (유한요소법을 이용한 스텐트의 기계적 성능 비교 및 평가)

  • 조승관;김한성;이상헌;탁계래;탁승제
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1306-1309
    • /
    • 2003
  • In the present paper, finite element analyses were carried out to evaluate the most important feature of a stent, that is. high radial strength and flexibility. Palmaz-Schatz 154 stent and two new models(stent A, stent B) were selected because they are the most representatives of tubular stents. Finite element analyses for the stent system were performed using ABAQUS/Explicit code. As a result, Palmaz-Schatz 154 stent shows sufficient radial strength but it needs some improvement in general properties such as high flexibility, low elastic recoil, low longitudinal contraction and low metal coverage area. Other two models show that sufficient flexibility, foreshortening and longitudinal recoil.

  • PDF

Quantitative analysis of hydrogen in thin film by scattering-recoil co-measurement technique (산란-되튐 동시 측정 방법에 의한 박막 중 수소 정량법)

  • Lee, Hwa-Ryun;Eum, Chul Hun;Choi, Han-Woo;Kim, Joonkon
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.400-406
    • /
    • 2006
  • Hydrogen analysis by elastic recoil detection has been performed utilizing polyimide film as a reference sample of known hydrogen content assuming the soundness of ion beam current integration. However beam current integration at higher incidence angle is not reliable. Scattering yield per unit fluence by current integration which is normalized per unit path length decreases as the sample tilt angle is getting higher. Moreover because beam current integration at high tilt angle is incomplete, hydrogen evaluation is very risky by direct comparison of sequentially collected recoil spectra between reference and target sample. In this study, primary ion beam dose is determined by backscattering spectrum that is collected simultaneously with recoil spectrum instead of ion beam current integration in order to reduce uncertainty arising in the process of current integration and to enhance the reliability of quantitative analysis. Three test samples are selected $-7.6{\mu}m$ polyimide film, hydrogen implanted silicondioxide and Au deposited carbon wafer- and analyzed by two methods and compared.

A Study on Optimal Shape of Stent by Finite Element Analysis (유한요소 해석을 이용한 스텐트 최적형상 설계)

  • Lee, Tae-Hyun;Yang, Chulho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.1-6
    • /
    • 2017
  • Stents are widely used as the most common method of treating coronary artery disease with implants in the form of a metal mesh. The blood flow is normalized by inserting a stent into the narrowed or clogged areas of the human body. In this study, the mechanical characteristics of a stent are investigated according to the variations of its design parameters by the Taguchi method and finite element analysis. A stent model of the Palmaz-Schatz type was used for the analysis. In the analysis, an elasto-plastic material model was adopted for the stent and a hyper-elastic model was used for the balloon. The main interest of this study is to investigate the effects of the design parameters which reduce the possibility of restenosis by adjusting the recoil amount. A Taguchi orthogonal array was constructed on the model of the stent. The thickness and length and angle of the slot were selected as the design parameters. The amounts of radial recoil and longitudinal recoil were calculated by finite element analysis. The statistical analysis using the Taguchi method showed that optimizing the shape of the stent could reduce the possibility of restenosis. The optimized shape showed improvements of recoil in the radial and longitudinal directions of ~1% and ~0.1%, respectively, compared to the default model.

Difference in Core Stability and Muscle Balance of the Pilates Teaser Motion According to Kinds of the Ground and Skills (지면의 종류와 숙련도에 따른 필라테스 티져(Teaser)동작의 코어안정화와 근육 균형의 차이)

  • Shin, Yun-Kyung;Yi, Kyung-Ock
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.1
    • /
    • pp.65-76
    • /
    • 2015
  • Objective : The purpose of this study was to analyse the differences in core stability and muscle balance of the pilates Teaser motion according to the surfaces and skills. Methods : There were 10 subjects in this study with 5 being skilled and 5 that were not skilled. The independent variables were surfaces (high elastic & aluminum) and skills (skilled & unskilled). Dependent variables were core stability and muscle balance. Core stability was measured by Force Platform (9872, Switzerland), 3D Imagery (IBS-2000, EXYMA) was used to understand the muscle balance. In order to do the Teaser movement subjects had to lay flat on their back and then lean forward as much as possible and hold the position for 10 seconds. Afterwards, they would lay back down again. A camera (MHS-PM5K, SONY) was used to make 4 phases (take off, recoil forward, holding, recoil backward) during the teaser exercise to analyze movement. In this study quantitative and qualitative analysis was used. For the statistical analysis, 2X2 ANOVA was used to analyze the differences in movement time, X,Y,Z maximum force, center of pressure and angles according to different phases. 2X3 ANOVA was used to analyze the differences in muscle balance via SPSS 18.0. Results : Soft. Elastic mat had a longer holding time, lower Fx/ Fy/ Fz, shorter Fx trajectory, larger angle and shorter gaps in muscle balance than a hard surface in skilled subjects. This was because the mat can help to recruit and then sustain core fine muscles during holding time in the Teaser movement.

Passivation Properties of Hydrogenated Silicon Nitrides deposited by PECVD

  • Kim, Jae Eun;Lee, Kyung Dong;Kang, Yoonmook;Lee, Hae-Seok;kim, Donghwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.334.2-334.2
    • /
    • 2016
  • Silicon nitride (SiNx:H) films are generally used as passivation layer on solar cell and they are usually made by plasma enhanced chemical vapor deposition (PECVD). In this study, we investigated the properties of silicon nitride (SiNx:H) films made by PECVD. Effects of mixture ratio of process gases with silane (SiH4) and ammonia (NH3) on the passivation qualities of silicon nitride film are evaluated. Passivation properties of SiNx:H are focused by making antireflection properties identical with thickness and refractive index controlled. The absorption coefficient of each film was evaluated by spectrometric ellipsometery and the minority carrier lifetimes were evaluated by quasi-steady-state photo-conductance (QSSPC) measurement. The optical properties were obtained by UV-visible spectrophotometer. The interface properties were measured by capacitance-voltage (C-V) measurement and the film components were identified by Fourier transform infrared spectroscopy (FT-IR) and Rutherford backscattering spectroscopy detection (RBS) - elastic recoil detection (ERD).

  • PDF

Dynamic Analysis and Experiments of High Impulsive Force Device with Isolation System (완충시스템을 장착한 고충격 발생기구의 동특성 해석 및 실험)

  • Park, Moon-Sun;Kang, Tae-Ho;Byun, Young-Seop;Song, Joon-Beom;Ku, Tae-Wan;Kang, Beom-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.10
    • /
    • pp.107-114
    • /
    • 2008
  • The aim of this study is to obtain the useful design guideline for high impulsive force device with an isolation system by the analytic approach of dynamics characteristics. In this study, the high impulsive force system was modeled and analyzed in view of multi-body dynamics, and verified the modeling and analysis result by the experiment of the high impulsive force device. Additionally, the dynamic analysis was performed for the isolation system with the selected coefficients of elastic spring and damper selected. Experimental result for the high impulsive force device with the isolation system was compared and analyzed. From the result, it was confirmed that the design guideline for the isolation system of the high impulsive force device was useful.

Comparison of Light Output from NE213 for Electrons and Protons

  • Shin, Hyun-Kook;Koh, Byung-Joon
    • Nuclear Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.111-117
    • /
    • 1979
  • The light output of the NE213 liquid scintillator to electrons and protons was measured by coincidence spectrometer which employs the time of flight technique. The proton energies (3.2Mev, 4Mev, 5Mev, 6Mev) represent the kinetic energies of recoil protons from elastic scattering of a polyenergetic neutron source Am-Be (about 2-9 Mev) at angle of 45$^{\circ}$ and 60$^{\circ}$. The response of the NE213 liquid scintillator to protons was varied nonolinearly as the energy increased. while the response to electrons was varied linearly. The light intensity produced by electrons was relatively larger than that of protons in the rate of about three times when the same energy was introduced. The results of the light output to protons were similar to those of Batchelor et al.

  • PDF

Pathophysiology of Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환의 병태생리)

  • Kim, Hyun Kuk;Lee, Sang-Do
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.1
    • /
    • pp.5-13
    • /
    • 2005
  • Chronic obstructive pulmonary disease (COPD) is a chronic progressive disease, characterized by irreversible airflow limitation, with a partially reversible component. The pathological abnormalities of COPD are associated with lung inflammation, imbalances of proteinase and antiproteinase, and oxidative stress, which are induced by noxious particles and gases in susceptible individuals. The physiological changes of COPD are mucus hypersecretion, ciliary dysfunction, airflow limitation, pulmonary hyperinflation, gas exchange abnormalities, pulmonary hypertension, cor pulmonale and systemic effects. The airflow limitation principally results from an increase in the resistance of the small conducting airways and a decrease in pulmonary elastic recoil due to emphysematous lung destruction. This article provides a general overview of the pathophysiology of COPD.

비정질 탄소막 (a-C:H) 내에 존재하는 수소에 관한 연구

  • 박노길;박형국;손영호;정재인
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.133-133
    • /
    • 1999
  • 비정질 탄소막 제조에 있어서 수소가 포함된 반응성 가스를 사용할 경우 제작된 탄소막 내부에는 수소가 포함되게 되며, 이러한 수소원자들은 막의 특성에 중요한 영향을 주는 것으로 알려져 있다. 따라서, 본 연구에서는 비정질 탄소막(a-C:H) 내부에 존재하는 수소가 탄소막의 특성에 미치는 영향을 알아보고, 막 내부에 포함된 수소의 함량과 공정조건 사이의 함수계를 조사함으로써 수소의 함량을 인위적으로 통제할 수 있는 가능성을 제시하고자 한다. 수소가 포함된 비정질 탄소막은 2.45 GHz의 전자기파를 사용하는 electron cyclotron resonance plasma enhanced chemical vapor deposition (ECR-PECVD) 방법과 DC magnetron sputtering 법을 사용하여 제작하였다. 기판으로는 Si(001) wafer를 사용하였으며, 아세톤과 에탄올을 사용하여 표면의 유기성분을 제거하고, 진공챔버속에서 Ar 플라즈마를 발생시켜 sputter etching 방법으로 표면을 세척하였다. ECR-PECVD 방법에서는 반응가스로 메탄(CH4)과 수소(H2)의 혼합가스를 사용하였으며, 혼합가스의 비는 5~50% 범위내에서 변화를 주었다. 수소가스의 유량은 100SCCM으로 고정하였으며, 마이크로웨이브의 power는 360~900W였고, 기판에 가해준 negative DC bias 전압은 0~-500V이었다. DC magnetron sputtering 방법에서는 반응가스로 아세틸린(C2H2) 가스를 사용하였으며, 플라즈마 발생을 용이하게 하기 위해서 Ar 가스와 혼합하여 사용하였다. Ar 가스의 유량은 10SCCM으로 고정하였으며, 아세틸렌 가스의 유량은 5~20SCCM 범위내에서 주입하였다. 이때, 기판에 가해준 negative DC bias 전압은 0~-100V이었다. 제작된 탄소막의 수소 함량을 조사하기 위하여 Fourier Transform Infrared (FTIR) 분광법과 Elastic Recoil Detection Analysis (EFDA) 법을 사용하였으며, 증착율은 SEM 단면촬영과 a-step을 이용하여 측정하였고, 막의 경도는 Micro-Hardness Testing 법을 사용하여 측정하였다.

  • PDF