• 제목/요약/키워드: Eigen system

검색결과 194건 처리시간 0.027초

Eigen - Environment 잡음 보상 방법을 이용한 강인한 음성인식 (Robust Speech Recognition using Noise Compensation Method Based on Eigen - Environment)

  • 송화전;김형순
    • 대한음성학회지:말소리
    • /
    • 제52호
    • /
    • pp.145-160
    • /
    • 2004
  • In this paper, a new noise compensation method based on the eigenvoice framework in feature space is proposed to reduce the mismatch between training and testing environments. The difference between clean and noisy environments is represented by the linear combination of K eigenvectors that represent the variation among environments. In the proposed method, the performance improvement of speech recognition systems is largely affected by how to construct the noisy models and the bias vector set. In this paper, two methods, the one based on MAP adaptation method and the other using stereo DB, are proposed to construct the noisy models. In experiments using Aurora 2 DB, we obtained 44.86% relative improvement with eigen-environment method in comparison with baseline system. Especially, in clean condition training mode, our proposed method yielded 66.74% relative improvement, which is better performance than several methods previously proposed in Aurora project.

  • PDF

인적정보의 고유기능과 계량화 방안에 관한 연구 (A Study on the Eigen Ethnic Function and Mathematical Processing Method of Human Information)

  • 김홍재;서윤정
    • 산업경영시스템학회지
    • /
    • 제19권40호
    • /
    • pp.329-339
    • /
    • 1996
  • This study presents the eigen ethnic function and mathematical processing method of human information. Human information can be definded as the overlap area taking the superposition property composed of intuition and sensory in stimulus/response (S/R) model, In S/R model, the intuition and sensory eigen ethnic function acts on the forming of perception. Perception process by the superposition property of intuition and sensory analogy to the basic neural network model. This analogy model extends to the analysis method. As an analysis method, optimal ratio number induced to the golden section ratio. Golden section ratio drived out by diverse source and implicated to the sensory and intuitive context such as beauty, harmony, optimality etc. This numerical orders can be applied to analysing the Perception process and extended to pursue the Potential human behavior, On the basic of proposed applying method, an illustrative mathematical examples are presented.

  • PDF

USE OF AN ORTHOGONAL PROJECTOR FOR ACCELERATING A QUEUING PROBLEM SOLVER

  • Park, Pil-Seong
    • Journal of applied mathematics & informatics
    • /
    • 제3권2호
    • /
    • pp.193-204
    • /
    • 1996
  • Overflow queuing models are ofter analyzed by explicitly solving a large sparse singular linear systems arising from Kolmogorov balance equation. The system is often converted into an eigenvalue problem the dominant eigenvector of which is the desired null vector. In this paper we convert an overflow queuing problem the dominant eigenvector of which is the desired null vector. In this paper we convert an overflow queuing problem into an overflow queuing problem into an eigen-value problem into an eigen-value problem of size 1/2 of the original. Then we devise an orthogonal projector that enhances its convergence by removing unsanted eigen-components effectively. Numerical result with some suggestion is given at the end.

Modal Analysis법에 의한 무주대공간 구조물의 좌굴해석 (Buckling Analysis of the Large Span Spatial Structures by Modal Analysis)

  • 한상을;권택진
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.195-201
    • /
    • 1996
  • This paper is mainly forcused on the application of modal analysis In analyze the geometrically non-linear buckling behaviors of large span spatial structures, and the evaluation of each eigen mode affected post-buckling behaviors and buckling loads. Modal analysis is applied . to derivation of the system matrices transforming actual displacement space into generalized coordinates space represented by coefficients multiplied in the linear combination of eigen modes which are independent and orthogonal each other. By using modal analysis method, it will be expected to save the calculating time by computer extremely. For example, we can obtain the satisfactorily good results by using about 7% of total eigen modes only in case of single layer latticed dome. And we can decrease the possibility of divergence on the bifurcation point in the calculation of post-buckling path. Arc-length method and Newton-Raphson iteration method are used to calculate the nonlinear equilibrium path.

  • PDF

Free vibration analysis of concrete arch dams by quadratic ideal-coupled method

  • Rezaiee-Pajand, Mohammad;Sani, Ahmad Aftabi;Kazemiyan, Mohammad Sadegh
    • Structural Engineering and Mechanics
    • /
    • 제65권1호
    • /
    • pp.69-79
    • /
    • 2018
  • This paper is devoted to two new techniques for free vibration analysis of concrete arch dam-reservoir systems. The proposed schemes are quadratic ideal-coupled eigen-problems, which can solve the originally non-symmetric eigen-problem of the system. To find the natural frequencies and mode shapes, a new special-purpose eigen-value solution routine is developed. Moreover, the accuracy of the proposed approach is thoroughly assessed, and it is confirmed that the new scheme is very accurate under all practical conditions. It is also concluded that both decoupled and ideal-coupled strategy proposed in the previous works can be considered as special cases of the current more general procedure.

대규모 전력계통의 과도안정도 상정사고 선택에 고유치감도 응용 (Applications of Eigen-Sensitivity for Contingency Screening of Transient Stability in Large Scale Power Systems)

  • 심관식;남해곤;김용구;송성근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.193-196
    • /
    • 1999
  • This paper presents a new systematic contingency selection and screening method for transient stability. The variation of modal synchronizing torque coefficient(MSTC) is computed using eigen-sensitivity analysis of the electromechanical oscillation modes in small signal stability model and contingencies are ranked in decreasing order of the sensitivities of the MSTC(SMSTC). The relevant clusters are identified using the eigenvector or participating factor. The proposed algorithm is tested on the KEPCO system. Ranking obtained by the SMSTC is consistent with the time simulation results by PSS/E.

  • PDF

원통형 액체저장탱크의 고유진동에 대한 이론적 연구 (Analytical Study on Free Vibration of Cylindrical Liquid-Storage Tanks)

  • 이진규;이상영;김기환;조진래;박태학;이우용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.602-607
    • /
    • 2000
  • Fuel-storage tank is a representative example of liquid-structure interaction systems. In order to prevent the undesired structural failure by a variety of external loads, the reliable analysis of the dynamic response of such structural system is of a great importance. In this paper, we address the analytical study on free vibration of axisymmetric cylindrical fuel-storage tanks together with the parametric investigation of eigen-characteristics with respect to the relative fuel fill-height and the relative tank height. Numerical results illustrating theoretical results are also included.

  • PDF

Performance of Multicarrier-CDMA Uplink with Antenna Arrays and Multiuser Detection

  • Sigdel, Shreeram;Ahmed, Kazi M.;Fernando, Anil
    • Journal of Communications and Networks
    • /
    • 제5권2호
    • /
    • pp.150-156
    • /
    • 2003
  • In this paper, an uplink MC-CDMA system incorporating multiuser detection and smart antennas has been considered. The performance of asynchronous as well as synchronous system is studied over a correlated Rayleigh multipath slow fading channel. A simplified array-processing algorithm suitable for slow fading situation is investigated to overcome the heavy computational complexity associated with Eigen solutions. The effect of variable data rate in the system performance is considered and effectiveness of antenna array to handle high data rate is discussed. A brief investigation on the system performance degradation due to correlated channel is also carried out. Based on the extensive simulation carried out, the performance of the asynchronous uplink system is found dramatically improved with antenna array and multiuser detection. Asynchronicity and channel correlation are found to affect the system performance significantly. The investigated simpli- fied algorithm produces similar results as Eigen solutions in slow fading situation with much reduced complexity.

지역모드 제동을 위한 고유치 감도와 PSS 설계 (Design of Power System Stability for Local Mode Using Eigen-Sensivity)

  • 송성근;남해곤;심관식;김용구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.14-16
    • /
    • 2001
  • The Eigen-Sensitivity theory at full system is used to supplement drawback of the existing PSS gain tuning methods in this paper. Hessenberg method is used to linear analysis. This proposed method is successfully tested on KEPCO 2003 off-peak power system to improve local mode. The designed PSS at 2003 off-peak system is installed in 2003 peak system to improve robustness.

  • PDF

가중치를 이용한 CDMA 시스템 성능분석 (On the Performance CDMA System Using Weighted Value)

  • 이관형;김학윤;송우영
    • 한국컴퓨터정보학회논문지
    • /
    • 제11권3호
    • /
    • pp.213-219
    • /
    • 2006
  • 이동통신시스템에서 사용자의 신호는 다른 방향에서 도래하는 신호로부터 간섭이 발생한다. 간섭을 제거하기위해서 다이버시티, 등화기 등 다양한 연구가 진행되었다. 본 논문에서는 배열안테나의 가중치을 구하여 신호대잡음비를 향상시키고자 한다. 가중치는 신호의 상관계수에 의해서 고유값과 고유벡터로부터 구한다. 구한 가중치를 CDMA시스템에 적용하여 시스템성능과 용량을 증가시켰다. 변조방식은 QPSK와 OQPSK를 시스템에 적용시켜 성능을 분석하였다.

  • PDF