• Title/Summary/Keyword: Egress safety

Search Result 92, Processing Time 0.023 seconds

Egress Safety of Nursing Hospital Considering Egress Guides and Smoke Exhaust System (피난유도자 수와 배연설비를 고려한 요양병원의 피난안전성 평가)

  • Choi, Seung-Ho;Darkhanbat, Khaliunaa;Heo, Inwook;Kim, Kang Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.3
    • /
    • pp.64-71
    • /
    • 2022
  • In this study, fire and egress simulation was conducted for the egress safety evaluation of the nursing hospitals. A fire simulation was performed with or without the smoke exhaust system using the FDS, and the available safe egress time (ASET) of the nursing hospitals was calculated. In addition, an egress simulation considering the characteristics of occupants and egress delay time was performed using Pathfinder, and the required safe egress time (RSET) was calculated. By comparing the ASET and RSET, the egress safety of the nursing hospital with or without a smoke exhaust system was evaluated according to the number of egress guides and the egress delay time. The simulation results show that the number of casualties increased as the egress delay time increased, and the required safe egress time decreased as the number of egress guides increased. In addition, it was found that if a smoke exhaust system with the capacity specified in the KFPA is secured, the available safe egress time can be greatly increased and the number of casualties can be greatly reduced.

A Study on the High-rise Apartment Balcony Plan for Egress Safety Design (고층 공동주택의 피난안전을 위한 발코니계획에 관한 연구)

  • 이용재
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.63-69
    • /
    • 2001
  • Applying a life safety concept to apartment design procedure is essential to protect people from unwanted fire. A Balcony design in apartment is a important egress safety factor because it provide means of safe egress and can limit a flame spread to adjacent space from fire source. Some design principles and details of balcony plan are suggested to improve egress safety level with analyzing broad case study.

  • PDF

A Study on the Improvement of Means of Egress Based on NFPA 101 (NFPA 101 피난 안정성 평가에 기초한 피난 규정 개선 방향 연구)

  • Kyeung-Ho Kang;Suck-Hwan Joung
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.1
    • /
    • pp.31-38
    • /
    • 2023
  • The object of this study is to evaluate whether the means of egress of Jechon Sports Center and Miryang Sejong Hospital, where massive fire human casualties occurred in 2017 and 2018 respectively, comply with NFPA 101(Life Safety Code), and to suggest the need for supplementation of domestic means of egress regulations. The study evaluated the number and arrangement of the means of egress, travel distance, common path of travel, dead end and discharge from exit for each building by applying the means of egress regulations of NFPA 101. As a result of the evaluation through NFPA 101, the travel distance was appropriate, but some of the other items except for the travel distance did not meet NFPA 101. The regulations that need to be supplemented are 1)occupant load calculation 2)egress capacity calculation 3)continuous concept of means of egress 4)concept of common path of travel. It is especially necessary to revise the requirement for fire door of the evacuation floor(normal 1st floor) of the stairwell in case of below the five story building.

A Study on the Comparison of Building Egress Safety Rule in Countries (건축물의 피난안전에 관한 국가간 기준 비교 연구)

  • 박재성;윤명오;이용재
    • Fire Science and Engineering
    • /
    • v.16 no.2
    • /
    • pp.27-32
    • /
    • 2002
  • As a result of increase of high-rise building and complex building in cities, fire damage become larger and complicated. However, law and standards in connection with life safety in the fire is deficient in safety performance and the institution of fire is divided into two parts : the building law and the fire law. The aim of this research is to compare with egress safety rule in advanced countries and to analyze the national standard of egress safety by investigating research data in order to make fire safety rule more effective. On the basis of this analysis, this research also suggested that reform measures should make egress safety in the fire.

A Investigation Study on the Development of Egress Simulation for Evacuation Safety Evaluation of Tokyo Fire Dept. Department in Japan (일본 동경소방청의 피난안정성평가 시뮬레이션 기술개발 사례연구)

  • Lee, Hyun-Jin;Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.216-222
    • /
    • 2008
  • A large number of Computer-based fire growth and Evacuation model have been developed for various purpose and many of these are widely used for research and engineering. And Most of Egress simulation program are ordinary case only related to human behavior But Egress safety Evaluation is very closed to smog movement. It is well known that the Egress simulation program made by Tokyo Fire Department are related to smog movement. So It is the aim of this study to investigate on the Development of Egress Simulation for Evacuation Safety Evaluation of Tokyo Fire Dept. Department in Japan.

  • PDF

Experiments on Egress of Persons with Mobile Disability in Train Car (철도차량에서의 지체장애인 피난 실험)

  • Kim, Jong-Hoon;Kim, Woon-Hyung;Roh, Sam-Kew;Lee, Duck-Hee;Jung, Woo-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.6
    • /
    • pp.865-872
    • /
    • 2009
  • Korean railroad company is continuously improving the service for the disabled. They also install and reform many facilities for them. However, It is not considered the importance of egress when fire occurred in a cabin Now, Fire hazard analysis and risk assessment are introduced into domestic regulations for improving fire safety performance of train car and railroad facilities. Considering the fact that fire safety evaluation process doesn't fully include disabled person, fundamental egress data for them is very important for life safety aspect. In this paper, Egress experiments and analysis were conducted to measure the movement speed of the disabled with Mugunghwa and Saemaul.

The Evaluation of the Egress Performance in the Buildings Installed with Luminous Egress Guide-lines (건축물내 자체발광식 피난유도선 설치에 따른 피난성능 평가)

  • Park, Yong-Hwan;Kim, Beom-Gyu;Lim, Chae-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.120-126
    • /
    • 2011
  • Recently luminous egress guide-lines are introduced for the fire safety of residents in the multi-use buildings such as Gosiwon. Little literature, however, on the quantitative and qualitative estimation for the egress performance of the luminous egress guide-lines can be found. This study carried out experimental investigations to evaluate the egress performance of the existing egress guide-lights and new luminous egress guide-lines. The results showed that both luminous egress guide-lines and egress guide-light satisfied the basic performance of KFI requirements. Under the 7 % smoke transmittance, however, luminous egress guide-lines showed 3 times longer visibility and less evacuation time than egress guide-lights. The evacuation density and smoke transmittance have significant effect on the evacuation time increase without the luminous egress guide-lines, however little effect with the installation.

The Study of Crowd Movement in Stair and Turnstile of Subway Station (지하철 역사에서의 계단 및 개찰구 군중흐름에 관한 연구)

  • Kim, Myeoung-Hun;Kim, Eung-Sik;Cho, Ju-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.3
    • /
    • pp.88-95
    • /
    • 2009
  • Most of subway stations are located underground and the number of passengers is far more than that of designed value, therefore the risk of accident is growing bigger and serious damage is expected in case of disaster. In Korea the period of evacuation study is short and numerical and experimental data of evacuation phenomena in subway station is rare. Many egress evaluation depend on foreign commercial S/Ws which are not yet proven its availability in special case such as subway station. In this paper outflow coefficients which are essential in egress evaluation are calculated at train door, stairway and turnstile at 3 most crowed subway stations. This numerical data can be used in prediction of egress evaluation and the result of other prediction methods can be verified with these experimental data.

A Study on the Evaluation Method of the Building Safety Performance and the during Building Fires with Computer Prediction of Occupants′ Egress Behavior Simulation (컴퓨터시뮬레이션에 의한 피난행태예측 및 안전성능평가 방법에 관한 연구(I))

  • 최원령;이경회
    • Fire Science and Engineering
    • /
    • v.3 no.1
    • /
    • pp.19-28
    • /
    • 1989
  • It has been recognized that the escape facility planning is very important for effective evacuation of accupants on fire event. The ultimate goal of the escape facility planning is to evacuate occupants rapidly from building fires to the safe areas. In fire event, occupants usually gather, utilize and finally act upon information about state transient of building fire system, which is consisted of components of fire, building and accupant during the ralatively short period of the fire event. That is, occupants' egress behavior is largely dependent upon building fire system. Therefore, comprehensive study for the relationship between building fire system and occupants' egress behavior is needed. This study aims to suggest the pre -occupancy evaluation method of the life safety performance for the architectural design based on prediction of occupants' egress behavior during building fires with computer simulation.

  • PDF

Experiments on Egress of Persons with Mobile Disability in Train Car (철도차량 화재 시 지체 장애인 피난 실험)

  • Kim, Jong-Hoon;Kim, Woon-Hyung;Roh, Sam-Kew;Lee, Duck-Hee;Jung, Woo-Sung
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1673-1679
    • /
    • 2009
  • Korean railroad company is continuously improving the service for the disabled. They also install and reform many facilities for them. However, They didn't consider the egress of the disabled when fire occurred until today. At present, fire hazard analysis and risk assessment are introduced into Korea regulation for improving fire safety performance of train car and railroad facilities. Fire safety evaluation for the railroad conducted in Korea didn't generally consider the disabled. In the present situation, the study for the egress of the disabled in train car was needed. The egress experiment was conducted to measure the movement speed of the disabled who didn't walk or walk very slow.

  • PDF