• Title/Summary/Keyword: Effiency

Search Result 35, Processing Time 0.03 seconds

Experimental Studies on the Effiency of Sagantang (사간탕(瀉肝湯)의 효능(效能)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Lee, Won-Ik;Lee, Won-Chul;Bai, Hyung-Sup;Koo, Bon-Hong
    • The Journal of Internal Korean Medicine
    • /
    • v.10 no.1
    • /
    • pp.39-52
    • /
    • 1989
  • The present investigation was undertaken to confirm of clinical effects of Sagnating. So, experimental studies were done, especially, to ascertain whether Sagantang had pharmacological effect of analgesia, antipyresis, diuresis and decreasing blood pressure and so on. The results of the studies were obtained as follows: 1. The analgesic effects of Sagantang were obtained in mice. 2. Sagantang prolonged the duration of hypnosis which is induced thiopental-Na in mice, but it was not effective in rotor rod method. 3. Antipyretic effect of Sagantang was known on the typhoid vaccine induced fever in rats. 4. Sagantang inhibited automatic movement on the isolated ileum of mice, and antiacetylcholine effect and antibarium chloride effect of Sangantang were known on that. 5. Sangantang decreased blood pressure due to vasodilatation in anesthetized mice. 6. The effect of diuresis were noted in mice. According to the above results, clinical effects of Sagantang on oriental medical references were similar to the actual experimental results.

  • PDF

Desorption Characteristics of Grinding Oil from Swarf by using Supercritical Carbon Dioxide (초임계 이산화탄소를 이용한 스와프로부터 연마유 탈착 특성)

  • Yang, Jun Youl;Lee, Youn-Woo;Lim, Jong Sung
    • Clean Technology
    • /
    • v.10 no.3
    • /
    • pp.139-148
    • /
    • 2004
  • The recovery of stainless steel fiber by removing cutting oil from grinding swarf, which is classified as specified wastes, was investigated. Swarf loaded with grinding oil was regenerated by supercritical carbon dioxide. And, the effects of temperature(313.15K-323.15K), pressure(10MPa-30MPa) on regeneration efficiency were studied. Regeneration effiency was increased as the pressure was increased. Also, at the same pressure, the experiments at higher temperature were more efficient for regeneration. The experiment results was predicted by applying a one-parameter mathematical model assuming linear desorption kinetics. The predicted value showed good agreement with experimental data.

  • PDF

Application of Partnering and Constructability in the Design Development Phase of Public Design-Build Projects (공공부문 일괄사업 실시설계단계의 파트너링과 시공성 분석 적용방안)

  • Nam, Yong-Ho;Yeon, Hee-Jung;Hong, Tae-Hoon;Koo, Kyo-Jin;Hyun, Chang-Taek
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.531-534
    • /
    • 2007
  • In the current domestic design-build contract, design and construction are separated due to prohibition of outside work. but instead the design-build contract adopts a method of fulfilling each assignment as a joint venture, which makes it difficult for participants to communicate each other and often require changes of design. also, It is difficult to performance efficiency project that they don't want to share useful information related to design and construction. In this study suggests how to maxmize the effiency of the project by proposing a process model connected with an efficient partnering and constructability in a deign development phase of design-build constract.

  • PDF

Composition of Cotton Textile Dyeing Process Wastewater and its Treatment Characteristics by Ionized Gas (면섬유염색폐수의 공정별 폐수성상과 이온화가스에 의한 처리특성)

  • Lim, Gyeong-Eun;Chung, Paul-gene;Kwon, Ji-Young;Lee, Eun-Ju
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.3
    • /
    • pp.303-308
    • /
    • 2007
  • Three types dyeing wastewater (dark, medium, light color) discharged from cotton textile dyeing with reactive dye was collected at each step of process. Each process dying wastewater was analyzed and treated by ionized gas. The analysis focused on $COD_{Cr}$, SS and color. Bleaching & scouring process wastewater has the highest $COD_{Cr}$ value in the three type dyeing wastewater. SS shows the highest value at dyeing process wastewater in dark and medium color but light color has at finishing process wastewater. The result of process wastewater treatment by ionized gas was that the ionized gas was effective in $COD_{Cr}$ removing of bleaching & scouring process and finishing process wastewater but was not good at dyeing process wastewater. From that result it is estimated that the ionized gas could not work in opening the aromatic ring and react only in aliphatic component of the molecule. Because the surfactants contained in bleaching & scouring process and finishing process wastewater have only one aromatic ring in its molecular structure, in contrast with the reactive dye compounds consist of aromatic rings great part of its molecular structure. The color almost removed in 1.5 hrs reaction time but $COD_{Cr}$ removal effiency was only 30.7% through 3hrs in 1500 mL of total dyeing wastewater treated by 10 L/min ionized gas.

New Isolated Zero Voltage Switching PWM Boost Converter (새로운 절연된 영전압 스위칭 PWM 부스트 컨버터)

  • Cho, Eun-Jin;Moon, Gun-Woo;Jung, Young-Suk;Youn, Myung-Joong
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.535-538
    • /
    • 1994
  • In this paper, an isolated ZVS-PWM boost converter is proposed for single stage line conversion. For power factor correction, we used the half bridge topology at the primary side of isolation transformer permitting switching devices to operate under ZVS by using circuit parastics and operating at a fixed duty ratio near 50%. Thus the relatively continuous input current distortion and small size input filter are also achievable. The ZVS-PWM boost operation of the proposed converter can be achieved by using the boost inductor $L_f$, main switch $Q_3$, and simple auxiliary circuit at the secondary side of isolation transformer. The secondary side circuit differ from a conventional PWM boost converter by introduction a simple auxiliary circuit. The auxiliary circuit is actived only during a short switching transition time to create the ZVS condition for the main switch as that of the ZVT-PWM boost converter. With a single stage, it is possible to achieve a sinusoidal line current at unity power factor as well as the isolated 48V DC output. Comparing to the two stage schemes, overall effiency of the proposed converter is highly improved due to the effective ZVS of all devices as well as single stage power conversion. Thus, it can be operated at high switching frequency allowing use of small size input filter. Minimum voltage and current stress make it high power application possible.

  • PDF

Comparison of Sampling Methods for Determining Airborne Mixture of Organic Solvents (공기중 유기용제 혼합물 측정방법의 비교연구)

  • Chun, Mee Hye;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.1
    • /
    • pp.16-28
    • /
    • 1991
  • A study on comparison of standard charcoal tube method, infrared gas analyzer, and detector tube method were conducted. Measurements were performed simultaneously at same sampling points in an air chamber containing benzene, toluene and xylene vapors. Charcoal tube samles were collected at sampling flowrates of 0.05, 0.2, 0.5, and 1.0 1pm. Results are as follows : 1. Coefficients of variation of results with charcoal tube method for bezene, toluene and xylene mixture vapor were 14.34 % in benzene(0.28-11.12 ppm), 9.20 % in toluene (2.68-135.09 ppm) and 10.21 % in xylene (2.56-82.64 ppm), respectively. 2. Results of infrared gas analyzer in mixture air were non-specific on benzene and toluene. Ratio of results of infrared gas analyzer to those of charcoal tube on benzene, toluene and xylene were 696.4 %, 30.3 % and 36.6 %, respectively. 3. Ratio of responses of detector tubes to those of charcoal tube were 49.4 % in benzene, 22.1 % in toluene and 223.9 % in xylene. Xylene detector tube were interfered by toluene greately. 4. Collection efficiencies of charcoal tubes at low concentraton(benzene : 1 ppm, toluene : 10 ppm, xylene : 10 ppm) were stable on various flowrate from 0.05 to 1.0 1pm, but at high concentrations the efficiency decreased at high flowrate above 0.5 1pm. 5. Within the saturation capacity of charcoal, collection effiency decreased at 0.5-1.0 1pm. Smpling feowrates of 0.05-0.20 1pm were appropriate for sampling organic vapors.

  • PDF

Research on Improvement of Efficiency in Flat Plate Solar Collector by Using Double-Wall Glazing and VIP Insulation (이중투과체 및 VIP복합 단열재 적용 평판 집열기의 성능 향상에 대한 연구)

  • Lee, Doo Ho;Jang, Han Bin;Kim, Young Hak;Do, Kyu Hyung;Lee, Kwang Seob;Lyu, Nam Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.11
    • /
    • pp.458-465
    • /
    • 2016
  • The purpose of this research is to improve the thermal effiency of solar collector and to quantitatively analyze its performance. Solar thermal systems have been limited to water heating systems mainly using low-temperature range. However, through diverse developments, the application has been extended to medium- and high-temperature fields such as solar heating, solar air conditioning, and solar thermal industrial process. Among the diverse research, this research is specially focusing on enhancement of the thermal performance by minimizing the heat loss coefficient of flat plate solar collectors. In order to do it, a front-side glazing material and a back-side insulation material with high insulated structure is proposed and based on computational analysis, the performance of energy collecting volume of the proposed solar collector is analyzed. The research shows that the proposed structure has the excellent performance at medium- and high-temperature range. therefore, it is expected that the proposed structure can easily replace existing technologies.

Investigation of the Ni/Cu metal grid space for high-effiency, low cost crystlline silicon solar cells (고효율, 저가화 태양전지에 적합한 Ni/Cu 금속 전극 간격에 따른 특성 평가)

  • Kim, Min-Jeong;Lee, Ji-Hun;Cho, Kyeng-Yeon;Lee, Soo-Hong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.225-229
    • /
    • 2009
  • The front metal contact is one of the most important element influences in efficiency in the silicon solar cell. First of all selective of the material and formation method is important in metal contacts. Commercial solar cells with screen-printed contacts formed by using Ag paste process is simple relatively and mass production is easy. But it suffer from a low fill factor and a high shading loss because of high contact resistance. Besides Ag paste too expensive. because of depends income. This paper applied for Ni/Cu metallization replace for paste of screen printing front metal contact. Low cost Ni and Cu metal contacts have been formed by using electroless plating and electroplating techniques to replace the screen-printed Ag contacts. Ni has been proposed as a suitable silicide for the salicidation process and is expected to replace conventional silicides. Copper is a promising material for the electrical contacts in solar cells in terms of conductivity and cost. In experiments Ni/Cu metal contact applied same grid formation of screen-printed solar cell. And it has variation of different grid spacing. It was verified that the wide spacing of grid finger could increase the series resistance also the narrow spacing of grid finger also implies a grid with a higher density of grid fingers. Through different grid spacing found alteration of efficiency.

  • PDF

Isolation and Characteristic of the Phosphate Solubilizing Bacteria Klebsiella sp. DA 71-1 (Hydroxyapatite 인산염 가용화 균 Klebsiella sp. DA 71-1의 분리와 가용화특성)

  • 이진우;정연주;이경아;최시림;김영길;최용락
    • Journal of Life Science
    • /
    • v.14 no.1
    • /
    • pp.174-179
    • /
    • 2004
  • To develop high effiency biofertilizer, a bacterium having ability to solubilize inorganic phosphate was isolated from cultivated soils, using a sucrose minimal agar-hydroxyapatite medium. The strain was identified as Klebsiella sp. DA7l-1, based on the physiological and biochemical properties. The activity of solubilizing inorganic phosphate of Klebsiella sp. DA7l-1 against three types of insoluble phosphate such as tri-calcium phosphate, aluminium phosphate, hydroxyapatite were quantitatively determined. The results indicated that the strain solubilized hydroxyapatite. The MPS (mineral phosphate solubilizing) conditions of Klebsiella sp. DA7l-1, were measured to determine the optimal conditions. The optimal temperature and initial pH to solubilize insoluble phosphate in sucrose minimal medium were $30^{\circ}C$ and pH 6.0, respectively.

Experimental studies of the effiency of Banhaonphetang and Banhaonphetang gamibang on the pulmonary injury in rats (반하온폐탕(半夏溫肺湯)과 반하온폐탕가미방(半夏溫肺湯加味方)의 효능(效能)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Seo, Ryoung-Suv;Jeong, Hee-Jae;Jung, Sung-Ki;Rhee, Hyung-Koo
    • The Journal of Korean Medicine
    • /
    • v.18 no.1
    • /
    • pp.208-217
    • /
    • 1997
  • Experimental studies were done to research the clinical effect of Banhaonpyetang and Banhaonpyetanggarnibang estimated the level of $pO_2,\;pCO_2$, and pH, the concentration of $HCO_{3}-ion$, the lung TBA(thiobarbituric acid) values in blood and oxygen consumption values in blood in $O_{3}-intoxicated$ rats. The results were obtained as follows. 1. Both Banhaonpyetang and Banhaonpyetanggamibang revealed the increasing effect with statistically significant on the blood $pO_2$ level in $O_{3}-intoxicated$ rats 2. Both Banhaonpytang and Banhaonpyetanggarnibang revealed the decreasing effect with statistically significant on the blood $pO_2$ level in $O_{3}-intoxicated$ rats 3. Both Banhaonpyetang and Banhaonphetanggarnibang revealed the decreasing effects with statistically significant on the blood $HCO_{3}level$ in $O_{3}-intoxicated$ rats. 4. Both Banhaonpyetang and Banhaonpyetanggamibang revealed the increasing effects with statistically significant on the blood pH level in. $O_{3}-intoxicated$ rats. 5. Both Banhaonpyetang and Banhaonpyetanggamibang revealed the decreasing effects with statistically significant on the Oxygen consumption values in $O_{3}-intoxicated$ rats. 6. Both Banhaonpyetang and Banhaonpyetanggamibang revealed the decreasing effects with statistically significant on the Lung TBA values in $O_{3}-intoxicated$ rats. According to the above findings, it is suggested that Banhaonpyetang and Banhaonpyetanggamibang retain effectiveness on the lung damages and can be used for treatment of respiratory disease.

  • PDF