• Title/Summary/Keyword: Efficient treatment

Search Result 2,200, Processing Time 0.033 seconds

Cost-effectiveness Analysis of Pharmacologic Treatment in Hypercholesterolemia (고콜레스테롤혈증 치료 약물들에 대한 비용-효과 분석)

  • 정경래;문옥륜
    • Health Policy and Management
    • /
    • v.9 no.3
    • /
    • pp.70-94
    • /
    • 1999
  • This paper was performed for a cost-effectiveness analysis of pharmacologic treatment of hypercholesterolemia. Agents modeled were cholestyramine, gemfibrozil. bezafibrate, lovastatin, pravastatin, simvastatin. Pharmacologic effectiveness was estimated by regression from reported clinical trials. Pharmacologic effects were expressed as the percent change of blood cholesterol level. Cost estimates included patients' travel expenses and time loss as well as resource consumption in the health care sector. Bezafibrate was the most efficient agent for reducing total cholesterol levels, having an cost over 1 year of ₩31.400 per percent reduction in total cholesterol. Simvastatin (10mg/d) was also efficient(₩33,100 per percent reduction). Chole styramine(8g/d) was least efficient at ₩90,200. For low-density lipoprotein cholesterol. simvastatin(10mg/d) was most efficient, at ₩23,200 per percent reduction, followed by lovastatin(20mg/d) at ₩28,000. Gemfibrozil was least efficient at ₩77,800 per percent reduction. For high-density lipoprotein cholesterol. bezafibrate(400mg/d) was most efficient at ₩39,300 per percent increase of high-density lipoprotein cholesterol. Cholestyramine was least efficient at ₩514,700. Analyses combining low-density lipoprotein cholesterol and high-density cholesterol effects suggest that bezafibrate(600mg/d) and simvastatin (10mg/d) were most efficient for reducing cardiovascular risk. The cost-effectiveness analysis results show that both simvastatin and bezafibrate could be efficient treatment. Simvastatin provide more effective treatment at higher cost, whereas bezafibrate is more cost-effective, as it may be less effective, at lower cost. Therefore, clinicians should choose reasonable treatment according to the patient's needs This pharmacoeconimc analysis will provide a guideline for efficient pharmacologic treatment and also be reference data for pricing new drugs.

  • PDF

A Study on Efficient Simple Water Supply System in Rural Areas (농촌지역의 효율적인 간이 상수처리에 관한 연구)

  • 이홍근;백남원;백도현
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.3
    • /
    • pp.103-115
    • /
    • 1996
  • The purpose of this study was to establish acceptable criteria for the design of simple water treatment plant in rural areas. To develop efficient simple water treatment methods for rural areas, water quality in the study areas was investigated and rapid and slow filtrations in pilot-scale were tested under various conditions. The main results of this study are as follows. It was found that the water qualities of the study areas exceed the drinking water standards, which implies that some treatments are required in rural areas. Treatment efficiencies of both rapid sand and dual-media (sand and anthracite) filtration without pre-treatment such as flocculation and sedimentation are very low, which were turned out to be unadequate for the rural areas. Treatment efficiencies of both vertical and horizontal slow filtration without chlorination are very high for consumed $KMnO_4, NH_3-N, NO_3-N$, turbidity, and very low for coliform and bacteria. Treatment efficiencies of both vertical and horizontal slow filtration with chlorination are very high over the most pollutants. A slow filtration with chlorination is efficient for the rural areas. An adequate depth of sand layer is over 60 cm. A horizontal filtration is more economical than a vertical filtration. A horizontal filtration can be operated for a relatively long periods of time without sand washing or replacement because clogging is removed by simple back-washing.

  • PDF

Recovering the Energy Potential of Sewage as Approach to Energy Self-Sufficient Sewage Treatment (하수처리장 에너지 자립화를 위한 하수 에너지 잠재력 회수 기술)

  • Bae, Hyokwan
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.1
    • /
    • pp.121-131
    • /
    • 2018
  • Domestic sewage treatment plants (STPs) consume about 0.5 % of total electric energy produced annually, which is equivalent to 207.7 billion Korean won per year. To minimize the energy consumption and as a way of mitigating the depletion of energy sources, the sewage treatment strategy should be improved to the level of "energy positive". The core processes for the energy positive sewage treatment include A-stage for energy recovery and B-stage for energy-efficient nitrogen removal. The integrated process is known as the A/B-process. In A-stage, chemically enhanced primary treatment (CEPT) or high rate activated sludge (HRAS) processes can be utilized by modifying the primary settling in the first stage of sewage treatment. CEPT utilizes chemical coagulation and flocculation, while HRAS applies returned activated sludge for the efficient recovery of organic contents. The two processes showed organic recovery efficiencies ranging from 60 to 70 %. At a given recovery efficiency of 80 %, 17.3 % of energy potential ($1,398kJ/m^3$) is recovered through the anaerobic digestion and combustion of methane. Besides, anaerobic membrane bioreactor (AnMBR) can recover 85% of organic contents and generate $1,580kJ/m^3$ from the sewage. The recovered energy is equal to the amount of energy consumption by sewage treatment equipped with anaerobic ammonium oxidation (ANAMMOX)-based B-stage, $810{\sim}1,620kJ/m^3$. Therefore, it is possible to upgrade STPs as efficient as energy neutral. However, additional novel technologies, such as, fuel cell and co-digestion, should be applied to achieve "energy positive" sewage treatment.

Electrolytic Treatment of Emulsified Oily Wastewater Using DSA Electrode (I) - Batch Treatment - (DSA 전극을 사용한 에멀젼 함유폐수의 전해처리 (I) -회분식 전해처리-)

  • 김인수;송영채
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.2 no.1
    • /
    • pp.67-75
    • /
    • 1996
  • An innovative batch electrolytic system consisted of electrolytic basin, which was equipped with DSA(Dimensionally Stable Anode) type insoluble electrode, Ti/IrO2 anode and H-C metal cathode, and flotation separator was developed for the efficient treatment of shipboard emulsified oily wastewater. The electorod cleance and current density of elecrolytic basin to ensure maximum treatment efficiency of oily wastewater was evaluated as 6 mm, 3 A/dm3, respectively. The electrolytic efficiency of oily wastewater was affected by the operationtemperature, and it means that the temperature controller to ensure the stabiity of the process is required. The conductivity in the electrolytic basin was increased with the percentage of sea water in the oily wastewater, and over 90% of treatment efficiency of oily wastewater could be obtained at 7% of sea water. The oil removal rate was increased according to the increase of the quantity of electricity, and the maximum value of electrilyic rate constant was 288 mgoil/A.min. The information obtained from this study might be used for development of an efficient continuous electrolytic system treating the emulsified oily wastewater.

  • PDF

Application of the Proper Air Supply Amount Based on the Influent Water Quality for the Development of Efficient Blower Control Logic in Sewage Treatment Plants (하수처리장의 효율적인 Blower Control Logic 개발을 위한 유입수질 기반 공기공급량 적용 연구)

  • Yeo, Wooseok;Kim, Jong Kyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.4
    • /
    • pp.493-499
    • /
    • 2022
  • The standards pertaining to the quality of discharged water in sewage treatment plants are strengthening, and accordingly, facilities in sewage treatment plants are being upgraded. In addition, the discharge water quality of sewage treatment plants must be maintained at a high level, and efficient sewage treatment plant operations have thus emerged as a very important issue. For the efficient operation of sewage treatment plants, this study applied a basic blowing amount calculation method based on sewage facilities to evaluate the required oxygen amount and blowing amount according to inflow water quality by logicizing various influencing factors. As a result of calculating the amount of air blown by applying actual April water quality data from sewage treatment plant A to the blower demand calculation developed through this study, it was found that the average amount of air blown was reduced by about 12%. When the blower demand calculation developed here is applied to an actual sewage treatment plant, the amount of air blown can be controlled based on the inflow water quality. This can facilitate the realization of an autonomous control of sewage treatment plants, in contrast to the existing sewage treatment operation method that relies on operational experience of operator. In addition, it is expected that efficient sewage treatment plants can be operated by reducing blowing amounts and power costs, which will contribute to both energy and carbon savings.

Heat Treatment Characteristics of Press Blanking Die by Using High Power Diode Laser (고출력 다이오드 레이저를 이용한 프레스 전단금형의 경화특성)

  • Hwang, Hyun-Tae;So, Sang-Woo;Hwang, Jae-Hyun;Kim, Jong-Do
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.23 no.5
    • /
    • pp.257-262
    • /
    • 2010
  • Recently, metal molding has become essential not only for automobile parts, but also mass production, and has greatly influenced production costs as well as the quality of products. Its surface has been treated by carburizing, nitriding and induction hardening, but these existing treatments cause considerable deformation and increase the expense of postprocessing after treatment; furthermore, these treatments cannot be easily applied to parts that requiring the hardening of only a certain section. This is because the treatment cannot heat the material homogeneously, nor can it heat all of it. Laser surface treatment was developed to overcome these disadvantages, and, when the laser beam is irradiated on the surface and laser speed is appropriate, the laser focal position is rapidly heated and the thermal energy of surface penetrates the material after irradiation, finally imbuing it with a new mechanical characteristic by the process of self-quenching. This research estimates the material characteristic after efficient and functional surface treatment using HPDL, which is more efficient than the existing CW Nd:YAG laser heat source.

Heat Treatment Characteristics of a Press Draw Mold by Using High Power Diode Laser (고출력 다이오드 레이저를 이용한 프레스 드로우금형의 열처리 특성)

  • Hwang, Hyun-Tae;So, Sang-Woo;Kim, Jung-Do;Kim, Young-Kuk;Kim, Byeong-Hun
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.22 no.6
    • /
    • pp.339-344
    • /
    • 2009
  • Recently, Laser surface treatment technologies have been used to improve wear charactenitics and fatigue resistance of metal molding. When the laser beam is irradiated on the surface and laser speed is appropriate, the laser focal position is rapidly heated and the thermal energy of surface penetrates the material after irradiation, finally imbuing it with a new mechanical characteristic by the process of self-quenching. This research estimates the material characteristic after efficient and functional surface treatment using HPDL, which is more efficient than the existing CW Nd:YAG laser heat source. To estimate this, microstructural changes and hardness characteristics of three parts (the surface treatment part, heat affect zone, and parental material) are observed with the change of laser beam speed and surface temperature. Moreover, the depth of the hardened area is observed with the change of the laser beam speed and temperature. From the results of the experiments, it has been shown that the maximum hardness is approximately 788Hv when the heat treatment temperature and the travel speed are $1150^{\circ}$ and 2 mm/sec, respectively.

An Efficient and Easy Discretizing Method for the Treatment of Noise Factors in Robust Design

  • Lanzotti, Antonio;Vanacore, Amalia
    • International Journal of Quality Innovation
    • /
    • v.8 no.3
    • /
    • pp.188-197
    • /
    • 2007
  • In this work, an efficient and easy statistical method to find an equivalent discrete distribution for a continuous random variable (r.v.) is proposed. The proposed method is illustrated by applying it to the treatment of the anthropometrical noise factors in the context of Robust Ergonomic Design.

A study on the characteristic of organic wastewater treatment in biofilm reactor with five types of media (생물막법에서 여재의 종류에 따른 유기성 오수의 처리 특성에 관한 연구)

  • 주욱종;권순국
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.508-512
    • /
    • 1998
  • Recently, biofilm reactors are considered as efficient wastewater treatment system in rural areas, because of characteristics of easy operation and economic feasibility. In order to select the most efficient media, an experimental apparatus with five different media was designed, installed and examined. The media used in this study were zeolite, artificial sponge gourd, absorbent biofilter, non-woven fabric and charcoal. With only one month investigation, all five media showed high removal efficiencies of BOD.

  • PDF

Preparation of Si(Al)ON Precursor Using Organoaluminum Imine and Poly (Phenyl Carbosilane), and the Compositional Change of the Film with Different Heat Treatment Condition

  • Lee, Yoonjoo;Shin, Dong-Geun;Kwon, Woo Teck;Kim, Soo Ryong;Kim, Younghee
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.4
    • /
    • pp.243-247
    • /
    • 2015
  • Si(Al)ON precursor was synthesized by formation of new Si-N bond using organoaluminum imine and liquid type poly(phenyl carbosilane). It was decomposed between $200-600^{\circ}C$, and the ceramic yield was 51% after pyrolysis. 150 - 200 nm in thickness of coating film was obtained by spin coating method. The precursor was easily oxidized during process because it was unstable in air. However the oxygen content was limited to 0.5 - 0.7 to silicon in heat treatment step. Even though the content of nitrogen was decreased by pyrolysis, Al-N and Si-N bonds were formed in ammonia atmosphere, and Si(Al)ON film was formed with 0.2 in content to silicon.