• Title/Summary/Keyword: Efficiency temperature coefficient

Search Result 274, Processing Time 0.026 seconds

Study on Performance Testing of Concentric Evacuated Tube Solar Energy Collector System (이중진공관형 태양열 집열기의 성능시험에 관한 연구)

  • Yoon, Young-Hwan;Kim, Kyung-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.2
    • /
    • pp.19-26
    • /
    • 2005
  • Concentric evacuated tube solar energy collector has been interested recently since government has driven to install alternative energy systems in new large building. In this paper, testing of the evacuated tube collector is conducted in outdoor during daytime by transient method. The collector thermal efficiencies are plotted in term of $(T_{in}-T_a)/Ic$, where $T_{in}$ is inlet working fluid temperature, $T_a$ is atmospheric temperature and $I_c$ is solar irradiation on the collector surface. The evacuated tube collector efficiency is ranged from 50% to 63% in real outdoor condition. In addition, the total overall heat loss coefficient is found to have an inverse variation to $(T_{in}-T_a)/I_c$ so that the coefficient becomes very high when $(T_{in}-T_a)/I_c$ is small.

Analyses of TOC Efficiency and Correlation between DO, BOD, COD and Influence Factors using Long-term Observation Data in the Main Stream of Nakdong River (낙동강 본류에서 장기관측 자료를 이용한 DO, BOD, COD와 그 영향인자의 상관관계 및 TOC 분해율)

  • Kang, Dong-hwan;So, Yoon Hwan;Park, Kyeong-deok;Kim, Il-kyu;Kim, Byung-Woo
    • Journal of Environmental Science International
    • /
    • v.28 no.5
    • /
    • pp.465-474
    • /
    • 2019
  • Herein, we analyzed the spatial and temporal variation of DO (dissolved oxygen), BOD (biochemical oxygen demand), and COD (Chemical Oxygen Demand) with the monthly mean observed data for 10 years (2008~2017) in the main stream of the Nakdong River. The water quality of the stations declined in a downstream direction, with the BOD and COD showing their highest values at the ST5 station. From the analysis of the correlation of water quality components at 10 stations, the correlation coefficient between the DO and water temperature was more than -0.90, and that between BOD and Chl-a was 0.48~0.85, and that between COD and TOC was more than 0.65 except for the ST5 and ST10 stations. From the regression analysis using data collected from all stations, the water temperature and DO decreased linearly with a coefficient of determination of 0.90, and the Chl-a and BOD could be described by increasing power functions with a coefficient of determination of 0.83. The TOC and COD followed increasing logarithm functions with a coefficient of determination of 0.58. The TOC efficiency at the 10 stations was estimated and the average efficiencies of BOD and COD were 15.5~36.3% and 57.4~89.6%, respectively.

A Study on Removal Efficiency of Cd by using Chitosan Complex isolated from Aspergillus oryzae (Aspergillus oryzae로부터 분리한 chitosan복합체에 의한 카드뮴 제거 효율에 관한 연구)

  • 장재선;이제만;김용희
    • Journal of environmental and Sanitary engineering
    • /
    • v.19 no.1
    • /
    • pp.37-41
    • /
    • 2004
  • The removal efficiency of cadmium by chitosan complex isolated from Aspersillus oryzae was investigated through laboratory experiments. The results of the study are as follows. The adsorption kinetics of cadmium was reached the adsorption equilibrium in approximately 20 minutes and the removal efficiency was showed 95.8%. The effect of temperature on cadmium adsorption by chitosan complex shows that as the temperature increased, the amount of cadmium adsorption per unit weight of chitosan complex increased. The correlation between amount of cadmium adsorption per unit weight of chitosan complex and temperature was obtained through the coefficient of determination($R^2$). $R^2$ values was 0.854(p<0.05). A linearized Freundlich equation was used to fit the acquired experimental data. As a result, Freundlich constant, the adsorption intensity(1/n) was 0.550, and the measure of adsorption(k) was 2.181. So, it was concluded that adsorption of cadmium by chitosan complex is effective.

Thermal Performance Evaluation of The Window Film Insulation for Building Energy Savings (건물에너지 절감을 위한 열차단 필름의 성능 평가)

  • Nam, Jung-Woo;Won, Jong-Seo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.75-80
    • /
    • 2008
  • Recently, Energy savings in buildings has received much attention in response to the increased needs for global warming and better comforts of the occupants in apartment housing. This study proposes the method which uses the sun control window film to reduce the cooling load and heating load improving the thermal performance of the building and it improves an energy efficiency. The film which used in actual measurement has a low shading coefficient and a solar energy transmission. so we measured the surface temperature of the triple Low-e glazing system used and inside temperature according to the change of outside temperature and solar energy to study thermal performance evaluation. As a result, it was helpful to use window film insulation to reduce inside temperature in summer and to keep room warm in winter.

  • PDF

Efficiency of a Direct Absorption Solar Collector using Ag Nanofluids Synthesized by Chemical Reduction Method (화학적 환원법으로 제조된 은나노유체를 사용한 직접흡수식 태양열 집열기의 효율)

  • Lee, Seung-Hyun;Park, Yong-Jun;Choi, Tae Jong;Jang, Seok Pil
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.5
    • /
    • pp.65-72
    • /
    • 2014
  • In this paper, the water-based Ag nanofluids are synthesized by the chemical reduction method and their extinction coefficients are measured by an in-house developed measurement device. The Ag nanofluids are manufactured by the chemical reduction method with the mixing of silver nitrate ($AgNO_3$) and sodium borohydride ($NaBH_4$) in an aqueous solution of polyvinyl pyrrolidone (PVP). The extinction coefficients of Ag nanofluids are measured by means of the in-house developed apparatus at a wavelength of 632.8nm according to the particle volume fractions. The results show that the extinction coefficient of water-based Ag nanofluids increases with the increase of nanoparticle concentrations. Finally, the temperature field and efficiency of direct absorption solar collector (DASC) are analytically estimated based on the measured extinction coefficient of water-based Ag nanofluids. The results indicate that the direct absorption solar collectors using nanofluids have the feasibility to improve the efficiency of conventional flat-plate solar collectors without using an absorber plate.

A Study on the Augmentation of Thermal Efficiency and the Development for the Fulidized Bed Combustor Untilizing Korean Low Grade Anthracite Coals (국산(國産) 저질무연탄(低質無煙炭) 연소용(燃燒用) 유동층(流動層) 연소로(燃燒爐) 개발(開發) 및 열효율(熱效率) 증대(增大)에 관한 연구(硏究))

  • Rhee, K.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.2
    • /
    • pp.112-118
    • /
    • 1990
  • Characteristics of heat transfer in a smooth and finned tube located vertically in atmospheric fluidized bed combustor which uses low grade anthracite coals was studied. Experiments to investigate the characteristics of heat transfer between smooth and finned tube are carried out and the results depend on particle size, fluidizing air velocity and bed temperature are summarized. It is found that heat transfer coefficient of the smooth and finned tube increases with decrease in particle diameter and increase in bed temperature. Furthermore, it is noted that heat transfer coefficient increase at the first with increase in the velocity of fluidizing air and tends to decrease at a certain fluidizing air velocity. The increase of heat transfer coefficient for the finned tube is appeared to be increased in 30% compared to that for the smooth tube.

  • PDF

Simulation of a two-stage absorption heat pump cycle using treated sewage (하수처리수 이용 흡수식 열펌프 사이클의 시뮬레이션)

  • 이용화;신현준;최국광
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.422-430
    • /
    • 1999
  • This paper concerns the study of a two-stage absorption heat pump cycle to utilize treated sewage. This two-stage cycle consists of coupling double-effect with parallel or series flow type and single effect cycle so that the first stage absorber and condenser produces hot water to evaporate refrigerant in the evaporator of the second stage. The effects of operating variables such as absorber temperature on the coefficient of performance have been studied for two-stage absorption heat pump cycle. The working fluid is lithium bromide and water solution. The efficiency of the two-stage absorption heat pump cycle has been studied and simulation results show that higher coefficient of performance could be obtained for the first stage with parallel flow type. The optimum ratio of solution distribution can be shown by considering the COP, the crystallization of solution and the generator temperature.

  • PDF

Simulation of the Characteristics of High-Performance Absorption Cycles (고성능 흡수냉동 사이클의 특성 시뮬레이션)

  • 윤정인;오후규;이용화
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.1
    • /
    • pp.231-239
    • /
    • 1995
  • This paper describes a computer simulation of the triple effect, water-lithium bromide absorption cooling cycles. The performance of the absorption systems is investigated through cycle simulation to obtain the system characteristics with the cooling water inlet temperature, the working solution concentrations, the ratio of the amount of the weak solution to the high, middle and low temperature generators, and the temperature difference of each solution heat exchanger. The efficiency of different cycles has been studied and the simulation results show that higher coefficient of performance could be obtained for the parallel cycle of constant solution distribution rate. As a result of this analysis, the optimum designs and operating conditions were determined based on the operating conditions and coefficient of performance.

Oxygen Transfer Characteristics of an Ejector Aeration System

  • Yang, Hei-Cheon;Park, Sang-Kyoo
    • International Journal of Fluid Machinery and Systems
    • /
    • v.5 no.1
    • /
    • pp.10-17
    • /
    • 2012
  • The objective of this study was to investigate the oxygen transfer characteristics of an ejector aeration system. In order to evaluate the oxygen transfer performance of the ejector aeration system, a comparative experiment was conducted on a conventional blower aeration system. The effect of entrained air flow rate and aerating water temperature on the oxygen transfer efficiency was investigated. The dissolved oxygen concentration increased with increasing entrained air flow rate, but decreased with increasing aerating water temperature for two aeration systems. The volumetric mass transfer coefficient increased with increasing entrained air flow rate and with increasing aerating water temperature for both aeration systems. The average mass transfer coefficient for the ejector aeration system was about 20% and 42% higher than that of the blower aeration system within the experimental range of entrained air flow rates and aerating water temperatures.

An Experimental Comparison Study of PVT Water and PVT Air Modules for Heat and Power Co-Generation (태양 열 전기 복합생산 PVT Water and PVT Air 모듈의 실험적 성능비교 연구)

  • Lee, Kwang-Seob;Putrayudha S., Andrew;Kang, Eun-Chul;Lee, Euy-Joon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.559-564
    • /
    • 2014
  • The development of photovoltaic-thermal (PVT) technology has been introduced in recent years specifically to increase PV efficiency. One of the characteristics of PV systems is that the electricity generation increases as the solar radiation increases whereas the efficiency decreases because of high surface temperatures. Using a photovoltaic-thermal system, the surface temperature can be decreased by capturing the excess heat and the efficiency can be increased due to these characteristics. In this paper, three cases are introduced : 1) PV_r as the reference case, 2) PVT_a, which uses air as a heat source, and 3) PVT_w, which uses water as a heat source. Experiments were performed, analyzed, and compared to examine the effect of the PVT type on the efficiency of the system. The results showed that ETC($%/^{\circ}C$) efficiency of the PVT cases was increased versus the reference case due to decreasing surface temperature. Total efficiencies, which are electrical efficiency and thermal efficiency, for each PVT are tested and found to be 12.22% for PV_r, 29.50% for PVT_a, and 68.74% for PVT_w.