Comparison of Measurement Methods for Head-related Transfer Function(HRTF) (머리전달함수 측정법의 실험적 비교)

  • Ahn, Tae-Soo;Lee, Doo-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.12
    • /
    • pp.1260-1268
    • /
    • 2009
  • Three methods(the stepped sine method, the statistical method(random excitation method) and the maximum-length sequence(MLS) method) for head-related transfer functions(HRTFs) are experimentally compared in view point of accuracy and efficiency. First, the stepped sine method has high signal-to-noise ratio, but low efficiency. Second, the statistical method is fast measurement speed, but weak to noise than the other methods. Finally, the MLS method shows both good efficiency and high signal-to-noise ratio, but it needs additional software or equipment such as MLS signal generator. For comparison of measurement accuracy, HRTFs of KEMAR dummy are measured for various azimuths and elevations. Error norms for magnitude and phase of HRTFs are defined and calculated for the measured HRTFs. The calculated error norms show that the methods give similar results in magnitude and phase except a little phase difference in the MLS method.

Study on Applicability of Multi-Criteria Decision Making Technique for Malfunctioning Reservoir Selection (기능저하 저수지 선정을 위한 다기준 의사결정기법 적용성 연구)

  • Shim, Hyun Chul;Choi, Kyung Sook
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.3
    • /
    • pp.11-19
    • /
    • 2017
  • The decision-making process is the act of finding the best solution among various alternatives through comparison between various criteria based on objectives of the project, evaluation standard, and conditions. However, in practice it is not easy to simply decide the optimum decision, especially for selecting malfunctioning reservoirs because no systematic evaluation criteria or standard assessment process are available. Therefore, this study adopted AHP method, which is a MCDM (multi-criteria decision making technique) to identify the malfunctioning reservoirs for efficient management of reservoirs. Important criteria of the selection of malfunctioning reservoirs and priority weights of each criteria were determined based on results of expert's survey under a stepwise hierarchical approach. The most important factor for the decision of malfunctioning reservoirs was obtained as Reservoir efficiency among the selected criteria including Reservoir efficiency decrease, Disaster Risk, Reservoir efficiency, Available water storage, Future water demand, Resident Needs. The AHP technique was applied on 11 reservoirs in Andong region to verify its applicability. Scoring method was applied for the comparison with the results of AHP method.

Numerical comparison of bearing capacity of tapered pile groups using 3D FEM

  • Hataf, Nader;Shafaghat, Amin
    • Geomechanics and Engineering
    • /
    • v.9 no.5
    • /
    • pp.547-567
    • /
    • 2015
  • This study investigates the behavior of group of tapered and cylindrical piles. The bearing capacities of groups of tapered and cylindrical piles are computed and compared. Modeling of group of piles in this study is conducted in sand using three-dimensional finite element software. For this purpose, total bearing capacity of each group is firstly calculated using the load-displacement curve under specific load and common techniques. Then, the model of group of piles is reloaded under this calculated capacity to find group settlements, stress states on the lateral surfaces of group block, efficiency of group and etc. In order to calculate the efficiency of each group, single tapered and cylindrical piles are modeled separately. Comparison for both tapered and cylindrical group of piles with same volume is conducted and a relation to predict tapered pile group efficiency is developed. A parametric study is also performed by changing parameters such as tapered angle, angle of internal friction of sand, dilatancy angle of soil and coefficient of lateral earth pressure to find their influences on single pile and pile group behavior.

Catalytic Reduction Efficiency Comparison between Porous Au, Pt, and Pd Nanoplates (요철형 금, 백금, 팔라듐 나노플레이트의 촉매성 환원 효율 비교)

  • Shin, Woojun;Kim, Young-Jin;Jang, Hongje;Park, Ji Hun;Kim, Young-Kwan
    • Composites Research
    • /
    • v.32 no.2
    • /
    • pp.85-89
    • /
    • 2019
  • The size, morphology and composition of nanoparticles are regarded as the most important factors to the efficiency of catalytic reduction of various chemical compounds. In order to make a systematic comparison, gold, platinum and palladium nanoplates with 100 nm diameter with rough surface morphology were manufactured through the galvanic replacement reaction, and the reaction kinetics of the catalytic reduction of 4-nitrophenol and 4-nitroaniline was systematically analyzed by spectroscopic measurement. According to the observation, the catalytic reduction efficiency was significantly different against the constitutional elements in order of Pd > Au > Pt, and it was additionally influenced by the type of substrate.

High Throughput Multiplier Architecture for Elliptic Cryptographic Applications

  • Swetha, Gutti Naga;Sandi, Anuradha M.
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.9
    • /
    • pp.414-426
    • /
    • 2022
  • Elliptic Curve Cryptography (ECC) is one of the finest cryptographic technique of recent time due to its lower key length and satisfactory performance with different hardware structures. In this paper, a High Throughput Multiplier architecture is introduced for Elliptic Cryptographic applications based on concurrent computations. With the aid of the concurrent computing approach, the High Throughput Concurrent Computation (HTCC) technology that was just presented improves the processing speed as well as the overall efficiency of the point-multiplier architecture. Here, first and second distinct group operation of point multiplier are combined together and synthesised concurrently. The synthesis of proposed HTCC technique is performed in Xilinx Virtex - 5 and Xilinx Virtex - 7 of Field-programmable gate array (FPGA) family. In terms of slices, flip flops, time delay, maximum frequency, and efficiency, the advantages of the proposed HTCC point multiplier architecture are outlined, and a comparison of these advantages with those of existing state-of-the-art point multiplier approaches is provided over GF(2163), GF(2233) and GF(2283). The efficiency using proposed HTCC technique is enhanced by 30.22% and 75.31% for Xilinx Virtex-5 and by 25.13% and 47.75% for Xilinx Virtex-7 in comparison according to the LC design as well as the LL design, in their respective fashions. The experimental results for Virtex - 5 and Virtex - 7 over GF(2233) and GF(2283)are also very satisfactory.

A Study on the Comparison of Emissions and Fuel Efficiency Performance of 2.0 Liter LPG Hybrid Engine and Vehicle (2.0 리터급 LPG 하이브리드 엔진 및 차량의 배출가스 및 연비성능 비교에 관한 연구)

  • Seokjoo Kwon;Bonseok Koo;Jaehoon Kang;Kangmyeon Kim;Sedoo Oh;Youngho Seo
    • Journal of ILASS-Korea
    • /
    • v.28 no.4
    • /
    • pp.191-197
    • /
    • 2023
  • LPG direct injection (LPDi) technology is a method of improving the weaknesses of existing LPG vehicles by directly injection into the combustion chamber. This study was conducted on the comparison of emissions and fuel efficiency performance of the engine and vehicle by applying LPDi technology. The LPDi hybrid engine's maximum output and maximum torque were measured at an equivalent level of less than 1% compared to conventional gasoline fuel. The fuel amount was corrected using the LCU controller, and the THC, CO, and NOx emissions were reduced to 90% in the operating range of the three-way catalyst through air-fuel ratio control. The analysis of THC+NOx and CO emissions in FTP-75 (CVS-75) driving mode satisfied the US LEV III SULEV30 regulation.

Comparison of Electrical Properties and AFM Images of DSSCs with Various Sintering Temperature of TiO2 Electrodes (TiO2 전극의 소결 온도에 따른 DSSCs의 전기적 특성 및 AFM 형상 비교)

  • Kim, Hyun-Ju;Lee, Dong-Yun;Lee, Won-Jae;Koo, Bo-Kun;Song, Jae-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.6
    • /
    • pp.571-575
    • /
    • 2005
  • In order to improve the efficiency of dye-sensitized solar cell (DSSC), $TiO_2$ electrode screen-printed on transparent conducting oxide (TCO) substrate was sintered in variation with different temperature$(350\;to\;550^{\circ}C)$. $TiO_2$ electrode on fluorine doped tin oxide (FTO) glass was assembled with Pt counter electrode on FTO glass. I-V properties of DSSCs were measured under solar simulator. Also, effect of sintering temperature on surface morphology of $TiO_2$ films was investigated to understand correlation between its surface morphology and sintering temperature. Such surface morphology was observed by atomic force microscopy (AFM). Below sintering temperature of $500^{\circ}C$, efficiency of DSSCs was relatively lower due to lower open circuit voltage. Oppositely, above sintering temperature of $500^{\circ}C$, efficiency of DSSCs was relatively higher due to higher open circuit voltage. In both cases, lower fill factor (FF) was observed. However, at sintering temperature of $500^{\circ}C$, both efficiency and fill factor of DSSCs were mutually complementary, enhancing highest fill factor and efficiency. Such results can be explained in comparison of surface morphology with schematic diagram of energy states on the $TiO_2$ electrode surface. Consequently, it was considered that optimum sintering temperature of a-terpinol included $TiO_2$ paste is at $500^{\circ}C$.

Efficiency Analysis of Contract-managed Business and Industry Foodservice Operations Using Data Envelopment Analysis (자료포락분석(DEA)을 이용한 위탁급식전문업체의 산업체 급식소 효율성 평가)

  • Choi, Kyu-Wan;Park, Young-Min;Shin, Seo-Young;Kwak, Tong-Kyung
    • Korean Journal of Community Nutrition
    • /
    • v.12 no.2
    • /
    • pp.178-188
    • /
    • 2007
  • This study was performed to suggest a new efficiency measurement indicator is necessary for evaluating management efficiency of food service operations in contract-managed foodservice companies, to distinguish efficient food service providers and inefficient ones by measuring comparative efficiency among food service operations, and to provide guidance for effective management through showing benchmarking targets for improving inefficient food service providers. The subjects of this study were the 93 B&I foodservice Operations of a domestic contract food service company. The analysis was conducted using CCR model in DEA model. A software, 'Frontier analyst', was used for the analysis. Based on the results derived from comparison of efficiency evaluation classified by providers with use of DEA, it was possible to identify efficient food providers and inefficient providers, and subsequently provide benchmarking guidelines for improvement of the inefficient groups. In analyzing the differences between the results of DEA efficiency evaluation by detailed operation status of food service providers, there was significant difference of efficiency outcomes in terms of contract types, while there was no significant difference in terms of business condition.