• Title/Summary/Keyword: Efficiency Standards

Search Result 981, Processing Time 0.028 seconds

Investigations on Microcrystalline Silicon Films for Solar Cell Application

  • Hwang, Hae-Sook;Park, Min-Gyu;Ruh, Hyun;Yu, Hyun-Ung
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.10
    • /
    • pp.2909-2912
    • /
    • 2010
  • Hydrogenated microcrystalline silicon (${\mu}c$-Si:H) thin film for solar cells is prepared by plasma-enhanced chemical vapor deposition and physical properties of the ${\mu}c$-Si:H p-layer has been investigated. With respect to stable efficiency, this film is expected to surpass the performance of conventional amorphous silicon based solar cells and very soon be a close competitor to other thin film photovoltaic materials. Silicon in various structural forms has a direct effect on the efficiency of solar cell devices with different electron mobility and photon conversion. A Raman microscope is adopted to study the degree of crystallinity of Si film by analyzing the integrated intensity peaks at 480, 510 and $520\;cm^{-1}$, which corresponds to the amorphous phase (a-Si:H), microcrystalline (${\mu}c$-Si:H) and large crystals (c-Si), respectively. The crystal volume fraction is calculated from the ratio of the crystalline and the amorphous phase. The results are compared with high-resolution transmission electron microscopy (HR-TEM) for the determination of crystallinity factor. Optical properties such as refractive index, extinction coefficient, and band gap are studied with reflectance spectra.

A Study on Work Development Direction of Cost Analysis through Cost Analysis of Micro Satellite (초소형위성 비용분석 사례연구를 통한 비용분석 업무발전 방향에 대한 고찰)

  • Lee, Tae Hwa
    • Journal of Korean Society for Quality Management
    • /
    • v.51 no.3
    • /
    • pp.461-479
    • /
    • 2023
  • Purpose: It emphasizes the importance of cost analysis for weapons systems that require enormous develop- ment costs, analyzes the problems of cost analysis steps from a practical point of view, and presents the direction of business development in terms of cost analysis reliability, timeliness, and efficiency. Methods: It analyzes the R&D cost of Micro satellites with a complex cost structure and large scale according to engineering estimation procedures, derives major analysis step-by-step problems, and presents business development directions. Results: Problems with standards and assumptions, data collection, cost division structure, and cost estimation methods were derived through the micro satellite cost analysis process, and business development directions such as expanding common standards, standardizing basic data, standardizing cost division structures and cost items, and data asset were presented. Conclusion: In order to develop work in terms of cost analysis reliability, timeliness, and efficiency, it is important to prepare and standardize standards and rules for detailed tasks at each analysis stage, and through this, it is expected that high utilization value and systematic cost data will be assetized in the future.

Determination of Dibutyltin in Sediments Using Isotope Dilution Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry

  • Yim, Yong-Hyeon;Park, Ji-Youn;Han, Myung-Sub;Park, Mi-Kyung;Kim, Byung-Joo;Lim, Young-Ran;Hwang, Eui-Jin;So, Hun-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.3
    • /
    • pp.440-446
    • /
    • 2005
  • A method is described for the determination of dibutyltin (DBT) in sediment by isotope dilution using liquid chromatography inductively-coupled plasma/mass spectrometry (LC-ICP/MS). To achieve the highest accuracy and precision, special attentions are paid in optimization and evaluation of overall processes of the analysis including extraction of analytes, characterization of the standards used for calibration and LC-ICP/MS conditions. An approach for characterization of natural abundance DBT standard has been developed by combining inductively-coupled plasma/optical emission spectrometry (ICP/OES) and LC-ICP/MS for the total Sn assay and the analysis of Sn species present as impurities, respectively. An excellent LC condition for separation of organotin species was found, which is suitable for simultaneous DBT and tributyltin (TBT) analysis as well as impurity analysis of DBT standards. Microwave extraction condition was also optimized for high efficiency while preventing species transformation. The present method determines the amount contents of DBT in sediments with expanded uncertainty of less than 5% and its result shows high degree of equivalence with reference values of an international inter-comparison and a certified reference material (CRM) within stated uncertainties.

Comparison of Test Standards for the Performance and Safety of Agricultural Tractors: A Review

  • Kabir, Md. Shaha Nur;Chung, Sun-Ok;Kim, Yong-Joo;Shin, Sung-Hyun
    • Journal of Biosystems Engineering
    • /
    • v.39 no.3
    • /
    • pp.158-165
    • /
    • 2014
  • Purpose: The objective of this paper was to compare test standards regarding the performance and safety of agricultural tractors to identify the differences in test conditions, measurement tolerances, and test procedures. Based on the comparison, some recommendations were proposed for possible revisions or improvements to current tractor test standards. Methods: The test standards and codes of major standards development organizations (SDOs), such as the Organization for Economic Cooperation and Development (OECD), the International Organization for Standardization (ISO), the American Society of Agricultural and Biological Engineers (ASABE), EC type approval, and the board of actions of the Nebraska Tractor Test Laboratories (NTTL), were selected and analyzed. Comparison of the test standards: The ISO provides references for fuel and lubricants for tractor tests, and the OECD provides additional measurements for calculating fuel consumption characteristics during the power take-off (PTO) tests. The ISO, EC type approval, and the ASABE provide PTO protective device and the safety requirements. During drawbar power tests, seven transmission ratios are selected for fully automatic transmissions, according to the OECD. In case of hydraulic lift tests, ISO 789-2 and OECD Code 2 advise the use of a static lift force, while SAE J283 advises the use of additional dynamic lift capacity tests for a better representation of in-field operations. The OECD, the ISO, and EC type approval determine the seat index point (SIP), whereas the ASABE determines the seat reference point (SRP) for roll-over protective structure (ROPS) tests. Diversified measurement tolerances were among the braking performance test standards. The European Union (EU) has developed daily limits for vibration exposures with adaptations from ISO 2631-1. Electromagnetic compatibility evaluations are emerging of high-efficiency tractors due to the long-term conformance to electromagnetic emissions and interferences. Comparisons of tractor test standards discussed in this paper are expected to provide useful information for tractor manufacturers and standards development personnel to improve the performance and safety test standards of tractors.

The Automatic Precision Measurement of RF Voltage using Power and Impedance Standards (전력과 임피던스표준을 이용한 RF전압의 정밀 자동측정)

  • Shin, Jin-Kook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.3A
    • /
    • pp.319-323
    • /
    • 2007
  • In this paper, the automatic precision measurement of RF voltage has been done using the power and impedance standards [1] in the frequency range of 50 to 1000 MHz. A coaxial microcalorimeter and an automatic network analyzer were used for the determination of the RF-DC differences and the total uncertainty is about 1.0 %. A HP computer, a commodore computer and IEEE-488 interface bus were used for measuring the effective efficiency of thermistor mount and the RF-DC difference of thermal voltage converter, All processes of measurement were accomplished by self-developed program automatically.

Design of A Multimedia Bitstream ASIP for Multiple CABAC Standards

  • Choi, Seung-Hyun;Lee, Seong-Won
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.6 no.4
    • /
    • pp.292-298
    • /
    • 2017
  • The complexity of image compression algorithms has increased in order to improve image compression efficiency. One way to resolve high computational complexity is parallel processing. However, entropy coding, which is lossless compression, does not fit into the parallel processing form because of the correlation between consecutive symbols. This paper proposes a new application-specific instruction set processor (ASIP) platform by adding new context-adaptive binary arithmetic coding (CABAC) instructions to the existing platform to quickly process a variety of entropy coding. The newly added instructions work without conflicts with all other existing instructions of the platform, providing the flexibility to handle many coding standards with fast processing speeds. CABAC software is implemented for High Efficiency Video Coding (HEVC) and the performance of the proposed ASIP platform was verified with a field programmable gate array simulation.

Optimization of Solid Phase Extraction Method for Quantitative Analysis of Perfluorooctanoic Acid in Serum using Liquid Chromatography-Tandem Mass Spectrometry

  • Lee, Hyun-Seok;Yim, Yong-Hyeon
    • Mass Spectrometry Letters
    • /
    • v.5 no.1
    • /
    • pp.30-33
    • /
    • 2014
  • A solid phase extraction (SPE) method was optimized for the quantitative analysis of perfluorooctanoic acid (PFOA) in serum using hydrophilic-lipophilic balance SPE and LC-MS/MS. Fetal bovine serums spiked with $^{13}C_8$-PFOA before or after SPE were used as test samples for evaluation of the SPE efficiency. Simultaneous evaluation of matrix effects and absolute SPE recovery for $^{13}C_8$-PFOA in serum using different sample pre-treatments and SPE conditions allowed optimization of SPE process efficiency with minimal matrix effect and decent SPE recovery. Introduction of protein precipitation as a sample pre-treatment procedure for serum samples before SPE generally decreased matrix effect in LC-MS/MS analysis and provided more stable recovery of PFOA.

Application of Home-made Capillary Zone Electrophoresis System to the Separation of Organic Molecules (제작된 모세관 전기영동 시스템의 유기물 분석에의 응용)

  • Kong Joo Lee;Gwi Suk Heo
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.3
    • /
    • pp.219-225
    • /
    • 1991
  • Capillary zone electrophoresis (CZE) which is highly efficient separation technique has been domestically established having optimum detection sensitivity. By applying 20∼35 kV of electric potential to the narrow (50 ${\mu}m$ i.d.) capillary tubing filled with running buffer, this technique can quickly (< 20 min) separate the small quantities of sample with high separation efficiency (number of theoretical plates : 200,000∼500,000). Factors affecting the separation efficiency and resolution in CZE were examined by analyzing adenine and catecholamine derivatives.

  • PDF

Efficiency of Energy Performance Improvement by Retrofit in existing Buildings (기존 건축물의 리트로핏에 따른 에너지 성능개선 효과 분석)

  • Kim, Dong-Hee;Moon, Hyunseok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.126-127
    • /
    • 2016
  • The Korean government has developed and strengthened energy related regulations to pursue eco-friendly buildings since 1979. However, required design standards for energy based quantitative studies focused on energy performance in existing buildings are meagered. Therefore in this study, required energy performance by design standards for energy are analyzed. And a energy performance by retrofits for insulation improvement is studied using energy simulations.

  • PDF