• Title/Summary/Keyword: Effective volume

Search Result 2,423, Processing Time 0.036 seconds

A Study on the Thermal Conductivity of Carbon-Nanotube Nanofluids (탄소 나노튜브 나노유체의 열전도도에 대한 연구)

  • Kim, Bong-Hun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.3
    • /
    • pp.275-283
    • /
    • 2007
  • An experimental study was conducted to investigate the effect of the morphology of CNT (Carbon Nanotube) on the thermal conductivity of suspensions. The effective thermal conductivities of the samples were measured using a steady-state cut bar apparatus method. Enhancements based on the thermal conductivity of the base fluid are presented as functions of both the volume fraction and the temperature. Although functionalized SWNT (Single-Walled Carbon Nanotube) produced more stable and homogeneous suspensions, the addition of small amounts of surfactant to suspensions of 'as produced' SWNT demonstrated a greater increase in effective thermal conductivity than functionalized SWNT alone. The effective thermal conductivity enhancement corresponding to 1.0% by volume approached 10%, which was observed to be lower than expected, but more than twice the values, 3.5%, obtained for similar tests conducted using aluminum oxide suspensions. However, for suspensions of MWNT (Multi-Walled Carbon Nanotube), the degree of enhancement was measured to be approximately 37%. It was postulated that the effect of clustering, resulting from the multiple heat-flow passages constituted by interconnecting neighboring CNT clusters, played an important role in significant enhancement of effective thermal conductivity.

Study on the Thermal Conductivity of Carbon-Nanotube Nanofluids (탄소 나노튜브 나노유체의 열전도도에 대한 연구)

  • Kim, Bong-Hun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.168-175
    • /
    • 2006
  • An experimental study was conducted to investigate the effect of the morphology of CNT on the thermal conductivity of suspensions. The effective thermal conductivities of the samples were measured using asteady-state cut bar apparatus method. Enhancements based on the thermal conductivity of the base fluid are presented as functions of both the volume fraction and the temperature, Although functionalized SWNT produiced a more stable and homogeneous suspension, the addition of small amounts of surfactant to suspensions of 'as produced' SWNT demonstrated a greater increase in effective thermal conductivity than functionalized SWNT alone. The effective thermal conductivity enhancement corresponding to 1.0 percent by volume approached 10%, which was observed to be lower than expected, but more than twice the values, 3.5%, obtained for similar tests conducted using aluminum oxide suspensions. However, for suspensions of MWNT, the degree of enhancement was measured to be approximately 37%. It was postulated that the effect of clustering, resulting from the multiple heat-flow passages constituted by interconnecting neighboring CNT clusters, played an important role in significant enhancement of effective thermal conductivity.

  • PDF

A Generalized Model on the Estimation of the Long - term Run - off Volume - with Special Reference to small and Medium Sized Catchment Areas- (장기만연속수수량추정모형의 실용화 연구 -우리나라 중소유역을 대상으로-)

  • 임병현
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.32 no.4
    • /
    • pp.27-43
    • /
    • 1990
  • This study aimed at developing a generalized model on the estimation of the long - term run - off volume for practical purpose. During the research period of last 3 years( 1986-1988), 3 types of estimation model on the long - term run - off volume(Effective rainfall model, unit hydrograph model and barne's model for dry season) had been developed by the author. In this study, through regressional analysis between determinant factors (bi of effective rainfall model, ai of unit hydrograph model and Wi of barne's model) and catchment characteris- tics(catchment area, distance round the catchment area, massing degree coefficient, river - exte- nsion, river - slope, river - density, infiltration of Watershed) of 11 test case areas by multiple regressional method, a new methodology on the derivation of determinant factors from catchment characteristics in the watershed areas having no hydrological station was developed. Therefore, in the resulting step, estimation equations on run - off volume for practical purpose of which input facor is only rainfall were developed. In the next stage, the derived equations were applied on the Kang - and Namgye - river catchment areas for checking of their goodness. The test results were as follows ; 1. In Kang - river area, average relative estimation errors of 72 hydrographs and of continuous daily run - off volume for 245 days( 1/5/1982 - 31/12) were calculated as 6.09%, 9.58% respectively. 2. In Namgye - river area, average relative estimation errors of 65 hydrographs and of conti- nuous daily run - off volume for 2fl days(5/4/1980-31/12) were 5.68%, 10.5% respectively. In both cases, relative estimation error was averaged as 7.96%, and so, the methodology in this study might be hetter organized than Kaziyama's formula when comparing with the relative error of the latter, 24~54%. However, two case studies cannot be the base materials enough for the full generalization of the model. So, in the future studies, many test case studies of this model should he carries out in the various catchment areas for making its generalization.

  • PDF

Research on the characteristics of noise exposure on worker wearing acoustic devices (음향도구 착용 근로자의 소음노출 실태에 관한 연구)

  • Kim, Kab-Bae;Yoo, Kye-Mook;Lee, In-Seop;Chung, Kwang-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.808-813
    • /
    • 2011
  • There are hundreds of thousands call center workers wearing acoustic device. However, researches and noise exposure measurements on the noise transmitted from acoustic devices have seldom been performed due to the difficulty of measurement and to the absence of the measuring method in Korea. The aim of this study is to set up management measures to protect hearing loss on the call operator by acquiring measurement data of noise transmitted from the headset Noise exposure measurements of 17 operators were performed in 7 call centers and Head and Torso Simulator method in compliance with the ISO Standard 11904-2 was used for the measurement of noise transmitted from the headset Sound pressure levels(SPL) transmitted from the headset were 73.2~86 dB(A). The operator exposed to the highest SPL set up his volume control at 9 which was the highest volume level. The volume control level, adjustable from 1 to 9, could be identified 12 out of 17 operators and the range of volume levels was 4.5~9. As a result of Pearson Correlation Analysis, the correlation between volume level and SPL transmitted from the headset showed high relation as significance at the 0.672 level(p<0.05). To protect hearing loss of call center operators, it is more practical and effective measure to limit the volume level below the noise exposure level, i.e. 85 dB(A), rather than to carry out noise monitoring considering cost-effective aspect.

  • PDF

Research on the Characteristics and Measures of Noise Exposure on Worker Wearing Acoustic Devices (음향도구 착용 근로자의 소음노출 실태에 관한 연구)

  • Kim, Kab-Bae;Yoo, Kye-Mook;Lee, In-Seop;Chung, Kwang-Jae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.7
    • /
    • pp.615-621
    • /
    • 2011
  • There are hundreds of thousands call center workers wearing acoustic device. However, researches and noise exposure measurements on the noise transmitted from acoustic devices have seldom been performed due to the difficulty of measurement and to the absence of the measuring method in Korea. The aim of this study is to set up management measures to protect hearing loss on the call operator by acquiring measurement data of noise transmitted from the headset. Noise exposure measurements of 17 operators were performed in 7 call centers and head and Torso simulator method in compliance with the ISO standard 11904-2 was used for the measurement of noise transmitted from the headset. Sound pressure levels(SPL) transmitted from the headset were 73.2~86 dB(A). The operator exposed to the highest SPL set up his volume control at 9 which was the highest volume level. The volume control level, adjustable from 1 to 9, could be identified 12 out of 17 operators and the range of volume levels was 4.5~9. As a result of pearson correlation analysis, the correlation between volume level and SPL transmitted from the headset showed high relation as significance at the 0.672 level(p<0.05). To protect hearing loss of call center operators, it is more practical and effective measure to limit the volume level below the noise exposure level, i.e. 85 dB(A), rather than to carry out noise monitoring considering cost-effective aspect.

Analytic Generation of Reach Volume Based on Range of Two Degrees of Freedom Motion (2자유도 동작범위를 고려한 reach volume의 해석적 생성)

  • Kee, Do-Hyung
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.23 no.1
    • /
    • pp.147-162
    • /
    • 1997
  • When designing workplaces or arranging controls on panel, devices and controls should be placed within the reach of operator's arm or foot to guarantee effective performances. Most of the existing research on the reach volume were based on measurements of a few subject's arm reach, and limited to Caucasian and Chinese populations. Furthermore, reach volume considering foot or trunk motion have not been investigated. Range of human joint motion and that of two degrees of freedom motion are needed to generate reach volume analytically using the sweeping algorithm. However, range of two degrees of freedom motion has not been measured up to now. Therefore, range of two degrees of freedom motion was measured in this research, where 47 college students were participated voluntarily as subjects. The results showed that the motion of one joint can be limited by the motion of another motion, that is to say, the shoulder flexion was decreased significantly when the shoulder was adducted or abducted. Second, new approximate algorithms generating reach volumes were suggested, in which range of two degrees of freedom motion was used as input data. Depending upon the body segment included such as trunk, arm and leg, three types of reach volume were provided, in which the human body was modeled as a multilink system based on the robot kinematics and the sweeping method was employed. Reach volume generated analytically in this study showed statistically reasonable results when compared with that obtained from direct measurement.

  • PDF

VOLUME REDUCTION OF DISMANTLED CONCRETE WASTES GENERATED FROM KRR-2 AND UCP

  • Min, Byung-Youn;Choi, Wang-Kyu;Lee, Kune-Woo
    • Nuclear Engineering and Technology
    • /
    • v.42 no.2
    • /
    • pp.175-182
    • /
    • 2010
  • As part of a fundamental study on the volume reduction of contaminated concrete wastes, the separation characteristics of the aggregates and the distribution of the radioactivity in the aggregates were investigated. Radioisotope $^{60}Co$ was artificially used as a model contaminant for non-radioactive crushed concrete waste. Volume reduction for radioactively contaminated dismantled concrete wastes was carried out using activated heavy weight concrete taken from the Korea Research Reactor 2 (KRR-2) and light weight concrete from the Uranium Conversion Plant (UCP). The results showed that most of the $^{60}Co$ nuclide was easily separated from the contaminated dismantled concrete waste and was concentrated mainly in the porous fine cement paste. The heating temperature was found to be one of the effective parameters in the removal of the radionuclide from concrete waste. The volume reduction rate achieved was above 80% for the KRR-2 concrete wastes and above 75% for the UCP concrete wastes by thermal and mechanical treatment.

Nonlinear Analysis of RC Structures Using Volume Control Method (체적 제어법을 이용한 철근 콘크리트 구조물의 비선형 해석)

  • Song Ha-Won;Nam Sang-Hyeok;Lee June-Hee;Lim Sang-Mook
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.891-897
    • /
    • 2006
  • The volume control method which utilize a pressure node added into a finite shell element can overcome the drawbacks of conventional load control method and displacement control method. In this study, an improved volume control method is introduced for effective analysis of path-dependant behaviors of RC structures subjected to cyclic loading. RC shell structures including RC hollow columns are anlayized by discretizing the structures with layered shell elements and by applying in-plane two dimensional constitutive equations for concrete layers and reinforcement layers of the shell elements. The so-called path dependant volume control method is verified by comparing analysis results with other data including experimental results.

  • PDF

Volume Reduction of Waste Water Sludge using Electrolysis (전기분해를 이용한 하수 슬러지 감량)

  • Lee, Byungheon;Bang, Myunghwan;Kim, Geonha
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.264-270
    • /
    • 2006
  • In this research, volume reduction of activated sludge using electrolysis was studied to find an optimum condition using lab scale experiments. Wasted sludge was treated by electrolysis with controlling current density, chloride concentration, electrode distance, and reaction time. Volume of return sludge was reduced by 9.79% in average while maximum was 16.7%. Sludge volume reduction efficiency was affected by current density and reaction time. It was reversely proportional to the electrode distance. Especially current density was effective on the system performance significantly. Electric conductivity, salinity and COD were increased by electrolysis implying sludge disintegrated and converted to COD in part. An empirical equation for total solid removal efficiency by electrolysis was proposed by multiple linear regression analysis as: $TS_{rem}$(%) = 5.534 ${\times}$ current density (A/l) + 0.178 ${\times}$ reaction time (m) + 2.758.

Relationship between Pedestrian Network and Pedestrian Volume Using Connectivity (연결도를 이용한 보행네트워크와 보행통행량의 상호관련성 연구)

  • Han, Sang-Jin;Kim, Young-Ook;Oh, Soon-Mi
    • Journal of Korean Society of Transportation
    • /
    • v.26 no.1
    • /
    • pp.137-144
    • /
    • 2008
  • It is important to know pedestrian volume to carry out pedestrian safety analysis and pedestrian friendly design. However, it is too difficult to come across research work related to pedestrian volume analysis in the field of transport, due to lack of interests on pedestrian movement. Most transport research has been focused on vehicles and highways rather than pedestrian. On the other hand, in the field of urban studies, there comes an effective tool to estimate pedestrian volumes using Space Syntax theory. This theory twins out to be effective and economic because it only requires network information, which is easy to acquire from maps and field survey. However, this method is different in the way representing networks from the way that is common in the field of transport. To make up for this point, this paper develops a novel measure for estimating pedestrian volume using Dial's algorithm, and applies the model in the two test networks; Insadong and Soongryemoon networks. The application results reveals that developed measure is an effective tool to explain pedestrian volume; a correlation coefficient between the measure and pedestrian volume is 0.713 in Insadong and 0.492 in Soongryemoon, and the goodness of fit($R^2$) of regression models are 0.893 in Insadong and 0.671 in Soongryemoon. This estimation method is significantly less complicated to estimate the effect of a pedestrian network change than Space Syntax theory, which requires special softwares not readily available.