• 제목/요약/키워드: Effective tube

검색결과 820건 처리시간 0.033초

Design of High Stability Space Tube

  • Lee Deog-Gyu;Woo Sun-Hee;Lee Eung-Shik;Youn Heong-Sik;Paik Hong-Yul
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.479-482
    • /
    • 2004
  • Laminate Design of a composite tube for a space telescope(Fig. 1) under hygrothermal load is studied. Carpet plots for laminate effective engineering constants are generated and used for selecting the best tube lay-ups satisfying the optomechanical requirements for a space telescope being dimensional1y stable under orbital thermal loading. Despace of the tubes constructed with the selected lay-ups are calculated with a Zig-Zag Triangular Element which accurately represents through thickness stress variations for laminated structures. The effects of moisture absorption when exposed to humidity environment and moisture desorption through outgassing on the dimensional stability are also investigated.

  • PDF

Axial compressive behavior of concrete-filled steel tube columns with stiffeners

  • Liang, Wei;Dong, Jiangfeng;Wang, Qingyuan
    • Steel and Composite Structures
    • /
    • 제29권2호
    • /
    • pp.151-159
    • /
    • 2018
  • In order to reduce the deformation and delay the local buckling of concrete filled steel tube (CFST) columns, strengthening the structures with stiffeners is an effective method. In this paper, a new stiffening method with inclined stiffeners was used to investigate the behaviors of short CFST columns under axial compression. Besides, a three-dimensional nonlinear finite element (FE) model was applied to simulate the mechanical performances, including the total deformation, local buckling, and stress-strain relationship. Revised constitutive models of stiffened steel tube and confined concrete are proposed. A good agreement was achieved between the test and FE results. Furthermore, the calculated results of load capacity by using a simplified method also show a good correlation with experimental data.

기상 화학증착법에 의해 $\alpha$-Alumina 지지관 상에 제조한 Silica막의 수소투과 특성 (Hydrogen Permeance of Silica Membrane Prepared by Chemical Vapor Deposition Method on an $\alpha$-Alumina Support Tube)

  • 김성수;이재홍;서동수;박상욱;서봉국
    • 한국환경과학회지
    • /
    • 제7권5호
    • /
    • pp.669-677
    • /
    • 1998
  • A porous $\alpha$-alumina tube of 2.5 mm O.D. and 1.9 mm I.D. was used as the support of an inorganic membrane. Macropores of the tube, about 150 nm in size, were plugged with silica formed by thermal decomposition of tetraethylorthosilicate at $600^{\circ}C$. The forced cross-flow CVD method that reactant was evacuated through the porous wall of the support was very effective in plugging macropores. The H$_2$ permeance of the prepared membrane was of the order of $10^{-8}/ molㆍs^{-1}/ㆍm^{-2}/. Pa{-1}$/, while the $N_2$ permeance was below $10^{-11}/ molㆍs^{-1}/ㆍm^{-2}/ㆍPa^{-1}$/ at $600^{\circ}C$. This was comparable to that of silica-modified Vycor glass whose size was 4 nm.

  • PDF

플라즈마 살균 효과 개선을 위한 공진용 인버터 전원 시스템 (Resonance inverter power system for plasma sterilization effective improvement)

  • 김주용;문상필;김종실;김영문;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1172-1174
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM)voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

플라즈마 살균 효과 향상을 위한 공전형 전원 시스템 (Resonance Inverter Power System for Sterilization Effective Improvement of Plasma)

  • 김주용;문상필;정장근;이현우;서기영
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.397-401
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM) voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with 6.5[㎑], 1.8[㎾] inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

증기발생기 전열관의 유체탄성불안정성 및 난류가진 특성 연구 (Study on the Fluid-elastic Instability and Turbulence Excitation for the Steam Generator Tube)

  • 유기완;박치용;박수기;이종호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1400-1405
    • /
    • 2001
  • In this study, an analysis program to assess the susceptibility of steam generator tubes due to the flow-induced vibration was developed. Analysis of fluid-elastic instability and random turbulence excitation for the U-tube bundle in CE-type steam generator was accomplished. The effective mass distribution along the U-tube was obtained to calculate the natural frequency and dynamic mode shape. Finally, stability ratios and rms vibration amplitude for selected tubes are obtained.

  • PDF

손마사지가 폐엽 절제술 환자의 흉관 제거시 통증과 불안에 미치는 영향 (The Effect of Hand Massage on Pain and Anxiety Related to Chest Tube Removal in Patients with a Lobectomy)

  • 송영숙
    • 기본간호학회지
    • /
    • 제9권1호
    • /
    • pp.27-44
    • /
    • 2002
  • The main purpose of this study was to identify the effect of hand massage on pain and anxiety related to chest tube removal in patients with a lobectomy. The research design of this study was a nonequivalent control group non-synchronized design. Of the twenty nine adult subjects, fourteen were assigned to the experimental group and fifteen to the control group. The data were obtained over 3 months from a medical center in Seoul. The instruments used to assess trait state anxiety was the Spielberger Trait-State anxiety Inventory. For pain and psychological anxiety. The Visual Analogue Scale was used. Hiko analogue sphygmo-manometer(2001) was used to check blood pressure and pulse rate as indicators of physiological anxiety Subjects in the experimental group received hand massage for 5 minutes just before chest tube was removed, and subjects assigned to the control group did not receive hand massage. Data were analysed with $x^2$-test and Mann-Whitney U test using the SPSSWIN 10.0 program. The results of the study are as follows : 1. Hypothesis 1: 'there will be a significant difference between two groups in the level of pain after chest tube removal' was supported (u = 23.00, p < 0.001). 2. Hypothesis 2: 'there will be a significant difference between the two groups in the level of psychological anxiety after chest tube removal' was supported (u = 3.00, p < 0.001). 3. Hypothesis 3: 'there will be a significant difference between the two groups in physiological anxiety(systolic, diastolic blood pressure and pulse rate) after chest tube removal' was supported(u =55.50, p = 0.01 ; u = 41.50, p = 0.01 ; u = 20.50, p < 0.001, relatively). The findings of this study indicate that hand massage is effective for pain and anxiety related to chest tube removal in patients with lobectomy. Therefore, hand massage is recommended as an effective nursing intervention for relieving pain and anxiety in patients undergoing chest tube removal. Further research is needed to identify the proper duration and timing to achieve the optimal effect of hand massage. A larger subject population is required to apply the current findings to the general population. Further research is also needed to assess the effects of hand massage in other patient subsets. Finally, it would be interesting to see if the effects of hand massaging would be attenuated when performed by a non-medical specialist.

  • PDF

심장수술 환아의 흉관제거시 통증에 대한 냉요법의 효과 (Effects of Ice pack application for the postcardiac surgery toddlers before C-tube removal)

  • 신희선;김동옥;조경미
    • 대한간호학회지
    • /
    • 제25권2호
    • /
    • pp.341-350
    • /
    • 1995
  • A quasi-experimental study was conducted to examine the effect of ice pack application to post cardiac surgery toddlers before C-tube removal. Twenty toddlers aged 13 months to 24 months, who were admitted to the hospital for open heart surgery during the period from July, 1993 to October, 1993 were randomly assigned to the experimental or control group. An ice pack was applied to the C-tube insertion site for 8 minutes before C-tube removal for the experimental group. The children were videotaped during the procedure to assess pain behavior and crying time. The score on the Modified Behavioral Pain Scale(MBPS), crying time, and vital signs were measured to determine the effect of ice pack application. The data were analyzed using Mann-Whitney U test, Paired t-test, and Pearson correlation coefficient. The result of the study are as follows : 1. There was a significant difference between the experimental group and the control group in pain behavior (U=17.0, p=.01). 2. There was no significant difference between the two groups in crying time. 3. There was a significant difference between the two groups in heart rate (U=24.5, p=.05). 4. There was a significant difference between the two groups in systolic blood pressure (U=24.0, p=.05) 5. There was a significant difference between the two groups in diastolic blood pressure (U=23.0, p=.04). 6. There was no significant difference between the two groups in respiration rate. 7. Pain behavior was significantly correlated with heart rate, systolic blood pressure, and crying time (r=.50, .54 and .59, p<.05). The result showed that the ice pack application was effective to reduce pain related to C-tube removal for the toddlers. From the study, it is recommended that the effectiveness of the cold ap-plication to children undergoing different painful procedures be examined to determine the most effective length of cold application to reduce pain in children.

  • PDF

Development of a Practical Two-Microphone Impedance Tube Method for Sound Transmission Loss Measurement of Sound Isolation Materials

  • Ro, Sing-Nam;Hwang, Yoon;Lee, Dong-Hoon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권3호
    • /
    • pp.105-113
    • /
    • 2003
  • This study developed a practical two-microphone impedance tube method to measure the sound transmission loss of sound isolation materials without the use of an expensive reverberation room or an acoustic intensity probe. In order to evaluate the validation and applicability of the two-microphone impedance tube method, sound transmission losses for several sound isolation materials with different surface density and bending stiffness were measured, and the measured values were compared with the results from the reverberation room method and the theory. From the experimental results, it was found that the accuracy of sound transmission loss obtained by the impedance tube method depends upon the diameter size of the impedance tube (i.e., tested sample size). For sound isolation materials having relatively large bending stiffness such as acryl, wood, and aluminum plates, it was found that the impedance tube method proposed by this study was not valid to measure the sound transmission loss. On the other hand, for sound isolation materials having relatively small bending stiffness such as rubber, polyvinyl, and asphalt sheets, the comparisons of transmission loss between the results from the impedance tube method and the theory showed a good agreement within the range of the frequencies satisfying the normal incidence mass law. Therefore, the two-microphone impedance tube method proposed by this study can be an effective measurement method to evaluate the sound transmission loss for soft sound isolation sheets having relatively small bending stiffness.

태양열 집열기 성능실험을 통한 공동주택 효율적 설치방안 연구 (A Study on the Effective Installation to the Apartment Through Solar Collector Performance Test)

  • 김미연;최병도;김형근;박진철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.480-487
    • /
    • 2012
  • The application of solar energy in residential building is general and natural in today. And application methods of solar thermal energy is divided in two kind of form, single evacuated tube and flat-plate form. Then in this study, the efficiency of single evacuated tube and flat-plate system is compared by total and effective area considering the time receiving the solar radiation between 24 hours and the specific time(10:00~15:00). As a result of the experiment, single evacuated tube and flat-plate collector's efficiency is varied by the quantity of solar radiation. And especially, the flat-plate system is more affected by outdoor temperature. Therefore the application of solar thermal system should be considered the solar radiation and outdoor temperature.

  • PDF