• Title/Summary/Keyword: Effective permeability

Search Result 533, Processing Time 0.024 seconds

Seepage analysis on seadike by considering permeability of the rubble base (바닥보호공의 투수성을 고려한 방조제의 침투류해석)

  • 조재홍;김서룡;장웅희;노종구
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.491-498
    • /
    • 2002
  • The rubble base in the seadike structure is construct with rubble-mound of big size for stability of seadike against a tidal current velocity at the closing. The permeability gives an effect to stability of seadike a lot in The case which rubble base is founded long with a lake direction like objective area of this study. The permeability of the rubble base produced in the model test regarding filling condition and materials of the rubble base, It applied the result which it tests in seepage analysis and it analyzed a stability of piping, In this study, it diminishes the permeability of the rubble base to respect, the pit soil more the dredge soil is effective and it was analyzed with the fact that it increases the stability of lake direction slope against the piping.

  • PDF

Magnetic Properties and Magnetoimpedance Effect in Mumetal Thin Films

  • Cho, Wan-Shik;Yoon, Tae-Sick;Lee, Heebok;Kim, Chong-Oh
    • Journal of Magnetics
    • /
    • v.6 no.1
    • /
    • pp.9-12
    • /
    • 2001
  • The dependence of the magnetoimpedance effect (MI) on magnetic properties has been investigated in mumetal thin films prepared by rf magnetron sputtering. Coercivity of thin films prepared at 400 W was about 0.4 Oe, and the magnetic anisotropy field of films deposited under a uniaxial magnetic field decreased with increasing film thickness. The saturation magnetization of mumetal films increased with rising input power and thickness and was smaller than that of permalloy films. Transverse incremental Permeability (TPR) of films of 1$\mu m$ thick increased with increasing effective permeability. The magneto impedance ratio (MIR) was proportional to TPR in films 1$\mu m$ thick but in spite of lower effective permeability at higher thicknesses, MIR increased due to skin effect. The height of the double peaks in the MIR curves decreased with decreasing anisotropy and thickness. The maximum MIR value for a 4$\mu m$ thick 75% at 36.5 MHz.

  • PDF

Testing of the permeability of concrete box beam with ion transport method in service

  • Wang, Jia Chun
    • Computers and Concrete
    • /
    • v.15 no.3
    • /
    • pp.461-471
    • /
    • 2015
  • The permeability is the most direct indicator to reflect the durability of concrete, and the testing methods based on external electric field can be used to evaluate concrete permeability rapidly. This study aims to use an experiment method to accurately predict the permeability of concrete box beam during service. The ion migration experiments and concrete surface resistivity are measured to evaluate permeability of five concrete box beams, and the relations between these results in service concrete and electric flux after 6 hours by ASTM C1202 in the laboratory are analyzed. The chloride diffusion coefficient of concrete, concrete surface resistivity and concrete 6 hours charge have good correlation relationship, which denote that the chloride diffusion coefficient and the surface resistivity of concrete are effective for evaluating the durability of concrete structures. The chloride diffusion coefficient of concrete is directly evaluated permeability of concrete box beam in service and may be used to predict the service life, which is fit to engineering applications and the concrete box beam is non-destructive. The concrete surface resistivity is easier available than the chloride diffusion coefficient, but it is directly not used to calculate the service life. Therefore the mathematical relation of the concrete surface resistivity and the concrete chloride diffusion coefficient need to be found, which the service life of reinforced concrete is obtained by the concrete surface resistivity.

Numerical study on PEM fuel cell performance with variation of GDL permeability and channel geometry (기체확산층의 유동투과율과 채널 형상 변화에 따른 고분자 전해질 연료전지 성능변화 수치연구)

  • Koh, Soo-Gon;Sohn, Sang-Ho;Nam, Jin-Hyun;Kim, Charn-Jung
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.3114-3119
    • /
    • 2008
  • Relatively high convective flow exists in the under-rib regions of a gas diffusion layer (GDL) when serpentine flow fields are employed in a PEMFC. This under-rib convection is believed to be favorable for the performance of PEMFCs, by enabling more effective use of catalysts in the under-rib regions. From the fact that the under-rib convection in a GDL is directly proportional to the permeability of the GDL, computational fluid dynamics (CFD) simulations were performed to discover the relationship between the GDL permeability and the PEMFC performance. Single-, triple-, and quintuple-path parallel serpentine flow fields for $9\;cm^2$ active cell area were considered while changing the GDL permeability from $1{\times}10^{-12}$ to $5{\times}10^{-11}m^2$. The results showed that higher GDL permeability generally resulted in better performance of PEMFCs, but the degree of performance enhancement became smaller as the parallel path number increased. The effects of the permeability on the local variables were also discussed.

  • PDF

Impact of Micellar Vehicles on in situ Intestinal Absorption Properties of Beta-Lapachone in Rats

  • Jang, Soung Baek;Kim, Dongju;Kim, Seong Yeon;Park, Changhee;Jeong, Ji Hoon;Kuh, Hyo-Jeong;Lee, Jaehwi
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.17 no.1
    • /
    • pp.9-13
    • /
    • 2013
  • The aim of the present study was to examine the effect of micellar systems on the absorption of beta-lapachone (b-lap) through different intestinal segments using a single-pass rat intestinal perfusion technique. B-lap was solubilized in mixed micelles composed of phosphatidylcholine and sodium deoxycholate, and in sodium lauryl sulfate (SLS)-based conventional micelles. Both mixed micelles and SLS micelles improved the in situ permeability of b-lap in all intestinal segments tested although the mixed micellar formulation was more effective in increasing the intestinal absorption of b-lap. The permeability of b-lap was greatest in the large intestinal segments. Compared with SLS micelles, the effective permeability coefficient values measured with mixed micelles were 5- to 23-fold higher depending on the intestinal segment. Our data suggest that b-lap should be delivered to the large intestine using a mixed micellar system for improved absorption.

Soil Properties regarding Geological Conditions in Landslides area (산사태 발생지역에서의 지질조건별 토질특성)

  • Song, Young-Suk;Kim, Won-Young;Chae, Byung-Gon;Kim, Kyeong-Su
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.884-889
    • /
    • 2005
  • A lot of landslides were occurred in Gangnung, Macheon and Geochang areas by Typhoons such as RUSA(2002) and MEAMI(2003). Soil properties of these areas are investigated regarding geological conditions in this study. The shallow plane failure were occurred in Gangnung and Geochang areas, whereas the deep circle failure were occurred in Macheon area. The matrix in Gangnung and Geochang areas was composed of Granite, and the matrix in Macheon area was composed of Gabbro. The disturbed and undisturbed soils were sampled in these areas. As the results of laboratory tests using sampled soils, the coefficient of permeability in Granite region is lower than that in Gabbro region. In the cases that the silt and clay contents are included less than 4% for the soils of Granite region and less than 7% for the soils of Gabbro region, the coefficients of permeability are rapidly increased for both soils. In addition, the simple equations for predicting the coefficients of permeability are proposed using the effective particle size and the silt and clay contents according to geological condition.

  • PDF

Assessment of Consolidation Properties Using Modified Oedometer for Radial Drainage Condition (개량형 수평배수 압밀시험 장치에 의한 압밀특성 평가)

  • Jeon, Jesung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.7
    • /
    • pp.143-150
    • /
    • 2009
  • Material functions about effective stress, permeability, coefficient of consolidation and coefficient of volume change has important role to predict consolidation velocity and settlement of soft ground. Modified oedometer for radial drainage is adapted to find out material functions on laboratory tests. Undisturbed sample for laboratory tests were taken from construction sites of industrial complexes on southern coastal area which consists of upper dredged fill and lower original clay layer. For different drainage condition in consolidation process void ratio, effective stress, permeability, coefficient of consolidation and coefficient of volume change has been assessed with results of existing standard oedometer tests. It is worthwhile to note that consolidation material functions could be expressed as regression equation by Stark (2005), heterogeneity for permeability could be assessed from these relationships.

  • PDF

Relationship Between AC and DC Magnetic Properties of an Iron-Based Amorphous Alloy for High Frequency Applications

  • Choi, Y.S.;Noh, T.H.;Lim, S.H.
    • Journal of Magnetics
    • /
    • v.1 no.1
    • /
    • pp.24-30
    • /
    • 1996
  • The relationship between effective permeability and the remanence ratio of an Fe-based amorphous alloy (Metglas 2605S3A) is investigated over a wide frequency range, in an effort to understand magnetization behavior of the alloy. In the frequency range from 1 to 200 kHz, the permeability is maximum at the remanence ratio of 0.4-0.5 and, at frequencies over 500 kHz, the correlation with negative coefficients emerges indicating that the permeability decreases with the remanent ratio, except for the ribbon coated with an insulating layer of MgO which exhibits both high values of the effective permeability and remanence ratio. It is considered from the correlation results that the boundary at which the dominant magnetization mechanism changes from domain wall motion to spin rotation is near 500 kHz. The core loss is also investigated as a function of annealing time when the samples are annealed at a fixed temperature of $435^{\circ}C$. The core loss in most cases decreases with the annealing time, the degree of the loss may consist of the hysteresis loss and anomalous eddy current loss. The two loss components are considered to be of similar magnitudes at low frequencies while, at high frequencies, the dominant contribution to the total loss is the anomalous loss.

  • PDF

Analytical Modeling for Microstructural Permeability Coefficient of (Non)Carbonated Concrete (탄산화 및 비탄산화된 콘크리트의 투수계수의 해석 기법 개발)

  • Yoon, In-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.3
    • /
    • pp.255-264
    • /
    • 2009
  • Permeability coefficient of concrete is a substaintial key parameter for understanding the durability performance of concrete and its microstructural densification. Many researches for the issue have been accomplished, however, it is very rare to deal with the theoretical study on permeability coefficient in connection with carbonation of concrete and the the effect of volumetric fraction of cement paste or aggregate on the permeability coefficient. The majority of these researches have not dealt with this issue combined with carbonation of concrete, although carbonation can significantly impact on the permeability coefficient of concrete. The purpose of this study is to establish a fundamental approach to compute the permeability coefficeint of (non)carbonated concrete. When simulating a microstructural characteristics as a starting point for deriving a model for the permeability coefficient by the numerical simulation program for cementitious materials, HYMOSTRUC, a more realistic formulation can be achieved. For several compositions of cement pastes, the permeability coefficient was calculated with the analytical formulation, followed by a microstructure-based model. Emphasis was on the microstructural changes and its effective change of the permeability coefficient of carbonated concrete. For carbonated concrete, reduced porosity was calculated and this was used for calculating the permeability coefficeint. The computational result was compared with experimental outcome.

Time Evolution of Water Permeability Coefficient of Carbonated Concrete (탄산화된 콘크리트의 투수계수에 대한 시간단계별 해석)

  • Yoon, In-Seok;Lee, Jeong-Yun;Cho, Byung-Young;Kim, Young-Geun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.1053-1056
    • /
    • 2008
  • Permeability coefficient of concrete is a substantial key parameter for understanding the durability performance of concrete and its micro-structural densification. Many researches to deal with the issue have been accomplished, however, it is very rare to deal with the theoretical study on permeability coefficient in connection with carbonation of concrete and the effect of volumetric fraction of cement paste or aggregate on the permeability coefficient. The majority of these researches have not dealt with this issue combined with carbonation of concrete, although carbonation can significantly impact on the permeability coefficient of concrete. The purpose of this study is to establish a fundamental approach to compute the permeability coefficient of (non)carbonated concrete. When simulating micro-structural characteristics as a starting point for deriving a model for the permeability coefficient by the numerical simulation program for cementitious materials, HYMOSTRUC, a more realistic formulation can be achieved. For several compositions of cement pastes, the permeability coefficient is calculated with the analytical formulation, followed by a microstructure-based model. Emphasis is on the micro-structural changes and its effective change of the permeability coefficient of carbonated concrete. The results of micro-structural water permeability coefficient model will be compared with results achieved from permeability experiments.

  • PDF