• Title/Summary/Keyword: Effective Thickness

Search Result 1,955, Processing Time 0.025 seconds

Enhancement of peri-implant bone formation via parathyroid hormone administration in a rat model at risk for medication-related osteonecrosis of the jaw

  • Park, Ji Young;Heo, Hyun A;Park, Suhyun;Pyo, Sung Woon
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.2
    • /
    • pp.121-131
    • /
    • 2020
  • Purpose: Dental implant-associated medication-related osteonecrosis of the jaw has been frequently reported in patients administered bisphosphonates (BPs) to prevent osteoporosis. The aim of this study was to investigate the effect of intermittent administration of parathyroid hormone (PTH) on peri-implant bone in the maxillae of ovariectomized rats systemically administered BPs. Methods: Thirty 8-week-old female Sprague-Dawley rats were randomly divided into 3 groups. The OVX-ZP group included ovariectomized rats administered 60 ㎍/kg of zoledronate once a week for 6 weeks and 30 ㎍/kg PTH after implant installation. The OVX-Z group included ovariectomized rats administered 60 ㎍/kg of zoledronate once a week for 6 weeks and saline after implant installation, and the control group included rats that underwent a sham operation and were then administered saline. Rats were sacrificed 4 weeks after implant placement for histomorphometric and micro-computed tomography (CT) analyses. Results: The average bone area percentage was greater in the OVX-ZP group than in the OVX-Z group (53.4%±4.0% vs. 28.9%±9.5%, P=0.01). The bone-to-implant contact ratio was 50.8%±1.4% in the OVX-ZP group and 16.9%±2.4% in the OVX-Z group (P=0.012). The average bone volume ratio as shown on micro-CT was 31.3%±19.8% in the OVX-ZP group and 19.4%±9.3% in the OVX-Z group (P=0.045). The OVX-ZP and OVX-Z groups displayed similar trabecular thickness (0.06±0.004 mm vs. 0.06±0.002 mm) (P>0.05) and trabecular separation (0.21±0.02 mm vs. 0.29±0.13 mm) (P>0.05). However, the number of trabeculae in the OVX-ZP group was significantly higher than that in the OVX-Z group (4.3±1.33/㎣ vs. 2.2±0.19/㎣) (P=0.024). Conclusions: The present findings indicate that intermittently-administered PTH can promote peri-implant bone formation and suggest that PTH administration may aid in effective treatment for medication-related osteonecrosis of the jaw after dental implantation.

MAXILLARY MOLAR DISTALIZATION WITH THE BONE-SUPPORTED PENDULUM (Bone-supported pendulum을 이용한 상악대구치 원심이동)

  • Jang, Yong-Gul;Park, Ho-Won;Lee, Ju-Hyun;Seo, Hyun-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.3
    • /
    • pp.464-474
    • /
    • 2009
  • To distalize the maxillary molars, the traditional techniques such as extra-oral traction, Wilson distalizing arches, removable spring appliances and Schwarz plate-type appliances have been used. But, these need considerable patient cooperation. For minimal patient compliance, many practitioners use the pendulum appliances. Several clinical studies demonstrated pendulum is effective molar distalization appliance in the growing patient(using the premolars and the palate as anchorage). But unfortunately, maxillary anterior teeth also shift mesially as the molar moves distally. As a result anchorage loss is occurred. To overcome these disadvantages, we used bone-supported pendulum, combined the conventional pendulum with Skeletal Anchorage System(SAS). The miniscrew was implanted in the anterior paramedian region of the median palatal suture, which has comparatively sufficient bone thickness and is low risk to damage on the dental follicles. We report three cases, using bone-supported pendulum for the maxillary molar distalization in children. After treatment, we find out anchorage stability, minimal unfavorable anterior tooth movement and sufficient molar distalization.

  • PDF

Effects of Ultraviolet Radiation on the Skin (자외선에 의한 피부반응)

  • Youn, Jail-Il
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.3
    • /
    • pp.181-186
    • /
    • 1995
  • UV irradiation causes a variety of biologic effects on the skin. These effects can be devided to acute reactuons and chronic reacxtions by duration of UV irradiation. Acute reactions are erythema reaction, pigment reactions and changes in epidermal thickness. Among them erythema reaction is most common and conspicuous acute effects of the skin. Upon exposure to sun or artificial UV soures, a faint redness response of skin may begin. Larger exposure causes sunburn reaction which is exaggerated erythema reactionassociated with pain, swelling, vesicle and dulla. Extent and time course of erythema reaction depend upon several factors including wavelength and dose of UVR, skin conditions likeas skin type, site, color, temperature, humidity and environmental factors. Evaluation of erythema erythema induced by UV irradiation is difficult to quantify. Degree of redness of skin are usually estimated by subjective visual evaluation. The lowest exposure dose required to protuce erythema is called minimal erythema dose (mod). Repeated exposures of UVR result in photaging skin. In this condition we can see wrinkling, skin atrophy, dilated blood vessels and keratoses. In sensitive persons photocarcinogenesis is can Be developed on exposed area of skin. Recently skin canser is increasing now in our country. An effective public education and photopreventive method must be developed.

  • PDF

Rapidly and Accurately Processing of Low Melting Block for Shielding of Radiotherapy (방사선(放射線) 치료(治療)의 신속정확(迅速正確)을 위한 저온용융(低溫熔融) 차폐물(遮蔽物)의 제작(製作)과 응용(應用))

  • Chu, S.S.;Lee, D.H.;Park, C.Y.
    • Journal of Radiation Protection and Research
    • /
    • v.4 no.1
    • /
    • pp.14-20
    • /
    • 1979
  • For accurate and easily shielding irregular shaped organ, its minimized penumbra region and a low melting point alloy 'Lead Y' and synchronizing instrument have been developed. The 'Lead Y' is the quaternary eutectic alloy and it is composed of Lead 30.0% Tin 11.5% Bismuth 48 5% Cadmium 10.0% The density of its at $22^{\circ}C$ is $9.8g/cm^3$ and the melting temperature has $40^{\circ}C\;to\;68^{\circ}C$. The thickness of 'Lead Y' for perfect shielding of Co-60 gamma ray and LINAC 10MeV x-ray is 6cm and 7cm respectively. The 'Lead Y' shielding block is casted directly on the styrofoam from which is cut with hot wire of synchronizer device. The special features and advantages of the Lead Y shielding block could be summarized as follows; 1. The shielding block for radiotherapy is rapidly processed only with boiling water and styrofoam. 2. It is not injure one's health and not danger of a fire, because of not generating of any metals vapor and evil smelling. 3. It is very effective to minimize secondary penumbra for the protection of healthy tissue from unnecessary ionizing radiation regardless of the magnification source to skin distance. 4. The HVL of the Lead Y is 1.2cm for Co-60 gamma ray and it's shielding effect is almost same as the pure lead block. 5. The hardness of Lead Y is 1.5 times higher than lead block. 6. It's reavailability is higher than lead block and then one block of Lead Y is reavailable about 30 to 40 times. 7. It is usefull for shielding of x-ray, gamma ray, beta-ray, electron and neutron radiation. 8. The materials for Lead Y are easy to acquire with reasonable price and tractable.

  • PDF

Broadband LTCC Receiver Module for Fixed Communication in 40 GHz Band (40 GHz 대역 고정통신용 광대역 LTCC 수신기 모듈)

  • Kim Bong-Su;Kim Kwang-Seon;Eun Ki-Chan;Byun Woo-Jin;Song Myung-Sun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.10 s.101
    • /
    • pp.1050-1058
    • /
    • 2005
  • This paper presents how to design and implement a very compact, cost effective and broad band receiver module for IEEE 802.16 FWA(Fixed Wireless Access) in the 40 GHz band. The presented receiver module is fabricated in a multi-layer LTCC(Low Temperature Cofired Ceramic) technology with cavity process to achieve excellent electrical performances. The receiver consists of two MMICs, low noise amplifier and sub-harmonic mixer, an embedded image rejection filter and an IF amplifier. CB-CPW, stripline, several bond wires and various transitions to connect each element are optimally designed to keep transmission loss low and module compact in size. The LTCC is composed of 6 layers of Dupont DP-943 with relative permittivity of 7.1. The thickness of each layer is 100 um. The implemented module is $20{\times}7.5{\times}1.5\;mm^3$ in size and shows an overall noise figure of 4.8 dB, an overall down conversion gain of 19.83 dB, input P1 dB of -22.8 dBm and image rejection value of 36.6 dBc. Furthermore, experimental results demonstrate that the receiver module is suitable for detection of Digital TV signal transmitted after up-conversion of $560\~590\;MHz$ band to 40 GHz.

X-RAY ASTRONOMY EXPERIMENT ON THE INDIAN SATELLITE IRS-P3

  • AGRAWAL P. C.;PAUL B.;RAO A. R.;SHAH M. R.;MCKERJEE K.;VARIA M. N.;YADAV J. S.;DEDHIA D. K.;MALKAR J. P.;SHAH P.;DAMLE S. V.;MARAR T. M. K.;SEETHA S.
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.429-432
    • /
    • 1996
  • An x-ray astronomy experiment consisting of three collimated proportional counters and an X-ray Sky Monitor (XSM) was flown aboard the Indian Satellite IRS-P3 launched on March 21, 1996 from SHAR range in India. The Satellite is in a circular orbit of 830 km altitude with an orbital inclination of $98^{\circ}$ and has three axis stabilized pointing capability. Each pointed-mode Proportional Counter (PPC) is a multilayer, multianode unit filled with P-10 gas ($90\%$ Ar + $10\%\;CH_4$) at 800 torr and having an aluminized mylar window of 25 micron thickness. The three PPCs are identical and have a field of view of $2^{\circ}{\times}2^{\circ}$ defined by silver coated aluminium honeycomb collimators. The total effective area of the three PPCs is about 1200 $cm^2$. The PPCs are sensitive in 2-20 keV band. The XSM consists of a pin-hole of 1 $cm^2$ area placed 16 cm above the anode plane of a 32 cm$\times$32 cm position sensitive proportional counter sensitive in 3-8 keV interval. The position of the x-ray events is determined by charge division technique using nichrome wires as anodes. The principal objective of this experiment is to carry out timing studies of x-ray pulsars, x-ray binaries and other rapidly varying x-ray sources. The XSM will be used to detect transient x-ray sources and monitor intensity of bright x-ray binaries. Observations of black-hole binary Cyg X-1 and few other binary sources were carried out in early May and July-August 1996 period. Details of the x-ray detector characteristics are presented and preliminary results from the observations are discussed.

  • PDF

The Effect of Impact Velocity on Droplet-wall Collision Heat Transfer Above the Leidenfrost Point Temperature (Leidenfrost 지점 온도 이상에서 액적-벽면 충돌 열전달에 대한 충돌 속도의 영향)

  • Park, Jun-seok;Kim, Hyungdae;Bae, Sung-won;Kim, Kyung Doo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.7
    • /
    • pp.567-578
    • /
    • 2015
  • Single droplet-wall collision heat transfer characteristics on a heated plate above Leidenfrost temperature were experimentally investigated considering the effects of impact velocity. The collision characteristics of the droplet impinged on the heated wall and the changes in temperature distribution were simultaneously measured using synchronized high-speed video and infrared cameras. The surface heat flux distribution was obtained by solving the three-dimensional transient heat conduction equation for the heated substrate using the measured surface temperature data as the boundary condition for the collision surface. As the normal impact velocity increased, heat transfer effectiveness increased because of an increase in the maximum spreading diameter and a decrease in the vapor film thickness between the droplet and heated wall. For We < 30, droplets stably rebounded from a heated wall without breakup. However, the droplets broke up into small droplets for We > 30. The tendency of the heat transfer to increase with increasing impact velocity was degraded by the transition from the rebounding region to the breakup region; this was resulted from the reduction in the effective heat transfer area enlargement due to the breakup phenomenon.

Effects of Concurrent Administration of JaUmJeSeupTangKaKam(JUJSTK) and Atopy Cream, Jawoongo(AJ) on Atopic Dermatitis-like Skin Lesions in NC/Nga Mouse (아토피양(樣)피부염 NC/Nga 생쥐에서 자음제습탕가감(滋陰除濕湯加減)과 아토피 크림-자운고(紫雲膏)의 병용투여가 피부염에 미치는 영향)

  • Lee, Nam-Yerl;Kim, Yun-Hee;Han, Jae-Kyung
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.23 no.3
    • /
    • pp.9-36
    • /
    • 2009
  • Objectives The purpose of this study is to examine the effect of a concurrent administration of JUJSTK and AJ on atopic dermatitis in an in-vivo experiment. Thus, this study is expressed by using NC/Nga atopic dermatitis mice which have histological and clinical similarities to that of humans have been used. Methods Clinical skin score, hematology, serum total IgE and IgG1 of the mouse was evaluated, and cytokine levels, total number of the cells, immunohistochemical staining, histological features of axillary lymph node(ALN), peripheral blood mononuclear cells(PBMCs), and a dorsal skin tissue of the mouse were analyzed. Results Oral administration of JUJSTK and concurrent administration of JUJSTK and AJ lowered the clinical skin score, total cell number of WBC, eosinophils in blood, and serum total of IgE & IgG1, IFN-$\gamma$, IL-5, IL-13, IL-17. In addition, total cell number of ALN and dorsal skin tissue, absolute cell number of $CD3e^+$ T cell, $CD4^+$ Th cell, $CD8^+$ c/sT cell, $CD3^+CCR3^+$ cell, $CCR3^+$ cell, $CD3^+CD69^+$, $CD4^+CXCR5^+$ in ALN, PBMCs, absolute cell number of $CCR3^+$, $CD3^+/CD69^+$, $CD11b^+/Gr-1^+$, $CD11b^+/Gr-1^+$ in dorsal skin tissue, Eotaxin2 mRNA, CCR3 mRNA in dorsal skin tissue and gene expression of IL-5 mRNA, IL-13 mRNA in ALN were significantly decreased. Furthermore, thickness of epidermis infiltrated inflammatory immune cell & mast cell in dermis, histological infiltration of mast cell, the size of inflammatory lymphocytes cells & plasma cells in ALN and histological infiltration of $CD4^+$ & $CCR3^+$ in ALN and dorsal skin tissue were significantly decreased as well. Conclusions Concurrent administration of JUJSTK and AJ on atopic dermatitis in an in-vivoexperiment by using an NC/Nga atopic dermatitis mouse was very effective as an atopic dermatitis treatment.

  • PDF

Effect of Jeseupwiryeongtang-gagam on Atopic Dermatitis-like Skin NC/Nga Mouse Induced by Dermatophagoides Farinae Crude Extract (제습위령탕가감이 집 먼지 진드기 추출물로 유도된 NC/Nga mouse의 아토피 피부염에 미치는 영향)

  • Na, Dong-Gyu;Han, Jae-Kyung;Kim, Yun-Hee
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.22 no.2
    • /
    • pp.81-114
    • /
    • 2008
  • Objectives : The purpose of this study is to investigate the effect of Jeseupwiryeongtang-gagam(JWTG) on atopic dermatitis by in vivo experiment using NC/Nga atopic dermatitis mouse, which has histological and clinical similarities to the atopic dermatitis of human. Methods : To investigate the effect of JWTG on AD, we evaluated atopic dermatitis-like skin lesions by clinical skin index and analyzed immunological parameters in peripheral blood mononuclear cells(PBMCs), splenocytes, draining lymph node(DLN) and performed skin histology in ears and dorsal skin of atopic dermatitis-like skin NC/Nga mouse in vivo. Results and Conclusions : In vivo, clinical skin severity score were significantly lower in JWTG group than control group. IgE, IL-6, $TNF-{\alpha}$, IgM, IgG2a and IgG2b levels in serum were decreased remarkably in JWTG group than control group and $IFN-{\gamma}$ production, secreted in Th1 cell were increased by JWTG. After experiment ended, we analyzed immunological cells ($CD3^+$, $CD19^+$, $CD4^+$, $CD8^+$, $CD3^+$$CD69^+$, $CD4^+$$CD25^+$ and $CD49b^+$) by flow cytometry. It resulted that total absolute number of $CD3^+$, $CD19^+$, $CD4^+$ and $CD8^+$ cells were recovered as normal and $CD3^+$$CD69^+$ were decreased significantly compared with control group in isolated DLN and PBMCs from NC/Nga mouse and total absolute number of $Gr-1^+$, $CD11b^+$ and $CD3^+$ in dorsal skin of NC/Nga mouse were decreased by JWTG. We analyzed ear, DLN, and neck-back skin after biopsy and dyeing by hematoxyline/eosin(H&E) and toluidine staining (mast cells marker) and obtained results that JWTG were effective to histological symptoms (dermal and epidermal thickening, hyperkeratosis and inflammatory cell infiltration). Ear thickness was decreased significantly than the control group and the size of inflammatory lymphocytes cells(ILC) and plasma cells(PC) in DLN were also decreased.

  • PDF

Effects of soy-based formula on infants' growth and blood laboratory values spanning 3 years after birth (대두 영유아식이 생후 3세까지 신체 계측치 및 혈액검사에 미치는 영향)

  • Yoon, Ji Eun;Kim, Mi-Jung;Han, Heon-Seok
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.1
    • /
    • pp.28-35
    • /
    • 2009
  • Purpose : We compared body growth, blood cell counts, and chemistry among infants receiving soy-based formula (SF), breast milk (BM), and casein-based formula (CF). Methods : Full-term neonates delivered at our hospital from June 2001 to August 2003 were recruited and divided into 3 feeding groups (BM=20, SF=19, CF=12 ) according to the parents wishes. Breast feeding or artificial formulae were given during the initial 3 months of age; thereafter, weaning foods were added freely. Height, weight, head circumference, skin-fold thickness, and mid-arm circumference were measured at birth and 1, 2, 4, 5, 12, and 36 months of age. Cell counts and blood chemistry were analyzed at 5, 12, and 36 months of age. Result : At 5 months of age, body weight was the lowest in the SF group; the height was similar among all groups. Thereafter, there were no differences in height or weight among the groups until 36 months of age. Hemoglobin was the lowest in the BM group at 5 and 12 months of age (P< 0.05 ). At 5 months of age, serum cholesterol, BUN, phosphates, and K+ were significantly lower in the SF group; thereafter, all chemical parameters were similar until 36 months of age. Conclusion : Infants fed with SF showed normal growth during the first 3 years of life as compared to infants fed with BM and CF. Low values of serum phosphates and K+ at 5 months of age in the SF group, despite the high mineral content, suggest that further investigation is needed for effective mineral absorption.