• 제목/요약/키워드: Effective Thickness

검색결과 1,955건 처리시간 0.027초

광대역 특성을 갖는 3층형 페라이트 전파흡수체의 설계 (A Design of Ferrite Electromagnetic Wave Absorber Three Layered Type with Wide-Band Characteristics.)

  • 이창우;김동일
    • 한국항해학회지
    • /
    • 제22권4호
    • /
    • pp.51-57
    • /
    • 1998
  • According to the rapid development of the electric industry, the demand of the frequency allocation and the usage of electromagnetic wave are increased due to automation of modem society. Electromagnetic wave absorbers for anechoic chamber are needed to broaden the effective frequency bandwidth, reduce the thickness, and decrease the weight. There are various absorbers proposed for the above conditions, but they could not decisively solve the above requirements. The Electromagnetic wave absorber made by a conventional ferrite tile has, for example, broadened the effective frequency bandwidth by the way of forming air layer(practically in urethane foam, etc.) on the ferrite tile. Therefore, an air layer is formed between a reflection plate and a sintered Ni-Zn ferrite tile of 7 mm in thickness, which has reflectivity less than -20 dB from 30 MHz to 400 MHz in bandwidth. In this paper, a broadband electromagnetic wave absorber are designed, which has the reflection characteristics less than -20 dB from 30 MHz to 8,000 MHz in the bandwidth. A super broadband electromagnetic wave absorber is achieved by inserting square Ferrite Cylinders Type with the thickness less than 23.5 mm and with the frequency band from 30 MHz to 8,000 MHz under the above tolerance limits. The purpose of this research is on the development of a universal anechoic chamber for measuring radiated electromagnetic wave or immunity of electronic equipments, GTEM-cell and also a wall material for preventing TV ghost, etc.

  • PDF

단축이방성 배향막이 코팅되어 있는 다층박막시료의 타원식 (Ellipsometric Expressions of Multilayered Substrate Coated with a Uniaxially Anisotropic Alignment Layer)

  • 김상열
    • 한국광학회지
    • /
    • 제24권5호
    • /
    • pp.271-278
    • /
    • 2013
  • 다층박막이 있는 기층에 단축이방성 배향막이 코팅되어 있을 때 비스듬히 입사한 빛의 유효반사계수 표현들을 유도하였다. 유효반사계수들과 타원상수들을 다층박막의 미지상수들은 물론 단축이방성 배향막의 광학이방성의 크기와 광축의 방향 그리고 배향막의 두께로 표현하였다. 이를 바탕으로 배향막의 정상굴절률과 이상굴절률, 배향된 두께 그리고 광축의 방위각과 기울임각을 다층박막의 두께나 조성비 등과 함께 타원법이 가지고 있는 높은 수준의 측정 정밀도를 유지하며 기존의 모델링 분석방법으로 결정할 수 있도록 하였다.

자동차 루프의 진동제어를 위한 제진재의 위치 및 두께에 대한 실험적 연구 (An Experimental Study on Placements and Thickness of Damping Material for Vibration Control of Automotive Roof)

  • 이정균;김찬묵;사종성
    • 한국자동차공학회논문집
    • /
    • 제13권6호
    • /
    • pp.31-37
    • /
    • 2005
  • This paper presents an experimental study on vibration characteristics of an automotive roof with damping material. The goal of the study is to extract modal parameters(natural frequency, loss factor, and mode shape) of automotive roof with damping materials treatment. To determine the effective positions and thickness of the damping material on a roof, vibration tests have been carried out for six cases; an aluminum plate with damping material on maximum strain energy positions, and an aluminum plate with damping material on nodal lines. From the result of aluminum plate, it is found that the damping material should be placed on the location with maximum strain energy part. For the automotive roof, patches of constrained damping material, which has two different density, have been attached to the positions of the maximum strain energy with four kinds of thicknesses. This paper shows that the proper positioning of the damping material is very important and the effective thickness is about twice that of the roof panel.

남성노인의 코어 안정화 운동 형태가 근 두께에 미치는 영향 (Change of Muscle Thickness on Exercise Type of Core Stabilization in Aged Men)

  • 임재길
    • 대한통합의학회지
    • /
    • 제8권1호
    • /
    • pp.67-76
    • /
    • 2020
  • Purpose : The purpose of this study was to provide more effective interventions for elderly men with weak core muscles by measuring the thickness of the muscles according to the five core stabilization exercise and comparing the thickness differences in muscles in each posture. Methods : The study selected 29 elderly men aged 65 to 80 years old among outpatient patients at S Medical Center in B city, and measured the muscle thickness by exercise posture once. In order to find out the thickness of the external oblique (EO), internal oblique (IO), and transverse abdominis (TrA) muscles were measured by using rehabilitative ultrasound imaging (RUSI) in five exercise conditions. Results : A significant change in the thickness of the EO muscles in each group was measured by the method of motion, followed by the abdominal crunches (1.67±0.15), the lower body rotations (1.54±0.07). As a result of measuring the thickness of the IO muscles of each group according to the exercise method, the bridge group (1.14±0.22) was the highest, followed by the abdominal drawing group (1.05±0.03). As a result of measuring the thickness of the TrA muscles of each group according to the exercise method, the abdominal crunches (0.98±1.00) were the highest, and the bridge group (0.57±0.05) were higher in order of magnitude. Conclusion : Consequently, the five core stabilization exercises all affect changes in abdominal thickness and are expected to continue to require training studies on muscle posture.

엎드려 무릎관절 굽힘 자세에서 엉덩관절 폄 동작 시 무게 부하 변화에 따른 큰볼기근과 넙다리두갈래근의 두께 비교 (A Comparison of Gluteus Maximus Muscle and Biceps Femoris Muscle Thickness According to Weight Load during Prone Hip Extension with Knee Flexion Exercises)

  • 장은미;정다은
    • PNF and Movement
    • /
    • 제21권3호
    • /
    • pp.309-317
    • /
    • 2023
  • Purpose: This study set out to investigate the effects of prone hip extension with knee flexion (PHEKF) exercises according to external load on the thickness of the gluteus maximus (Gmax) and biceps femoris (BF). Methods: Twenty-three healthy men participated in this study. All subjects randomly practiced PHEKF under the burden of external loads created by sandbags (0 kg, 1 kg, and 2 kg). Rehabilitative ultrasound imaging (RUSI) was used to measure the thickness of the Gmax and BF during the PHEKF with different external loads. Results: The thickness of the Gmax was highest during the 2 kg resistance exercise and lowest at 0 kg. The thickness of the Gmax was significantly increased at 1 kg and 2 kg compared to 0 kg and significantly increased at from 1 kg to 2 kg (p < 0.05). The thickness of the biceps femoris was highest at 0 kg and lowest at 2 kg. The thickness of the biceps femoris muscle was significantly reduced at 1 kg and 2 kg compared to 0 kg (p < 0.05), but there was no significant difference between 1 kg and 2 kg (p > 0.05). Conclusion: The thickness of the Gmax was increased by applying PHEKF with a higher external load, whereas the muscle thickness of the biceps femoris decreased. These results suggest that the application of external loads during PHEKF exercises may be an effective method for selective strengthening of the Gmax.

Comparison of light transmittance in different thicknesses of zirconia under various light curing units

  • Cekic-Nagas, Isil;Egilmez, Ferhan;Ergun, Gulfem
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권2호
    • /
    • pp.93-96
    • /
    • 2012
  • PURPOSE. The objective of this study was to compare the light transmittance of zirconia in different thicknesses using various light curing units. MATERIALS AND METHODS. A total of 21 disc-shaped zirconia specimens (5 mm in diameter) in different thicknesses (0.3, 0.5 and 0.8 mm) were prepared. The light transmittance of the specimens under three different light-curing units (quartz tungsten halogen, light-emitting diodes and plasma arc) was compared by using a hand-held radiometer. Statistical significance was determined using two-way ANOVA (${\alpha}$=.05). RESULTS. ANOVA revealed that thickness of zirconia and light curing unit had significant effects on light transmittance ($P$ <.001). CONCLUSION. Greater thickness of zirconia results in lower light transmittance. Light-emitting diodes light-curing units might be considered as effective as Plasma arc light-curing units or more effective than Quartz-tungsten-halogen light-curing units for polymerization of the resin-based materials.

지하레이다(GPR)를 이용한 터널 라이닝 비파괴시험에 관한 연구 (Non-Destructive Test for Tunnel Lining Using Ground Penetrating Radar)

  • 김영근;이용호;정한중;신상범;조철현
    • 터널과지하공간
    • /
    • 제7권4호
    • /
    • pp.274-283
    • /
    • 1997
  • It is necessary to estimate the soundness of tunnel using non-destructive tests(NDT) for effective repairs and maintenances. But, the state of tunnel lining could not be investigated using previous non-destructive techniques, due to the various types of support and accessibility only from one side in tunnel lining. Recently, the various non-destructive techniques such as ground penetrating radar(GPR) have been researched and developed for inspection of tunnel lining. In this study, the usefulness and applicability of GPR test in tunnel lining inspection has been investigated through model tests and tunnel site application. This paper described the tunnel lining inspection for lining thickness, cavity and support using GPR test. From the results of tests, we have concluded that GPR test are very useful and effective techniques to look into the interior of lining and measure the lining thickness.

  • PDF

급격히 꺾인 Taper를 갖는 Traveling-wave Coplanar Waveguide형 $LiNbO_34$전기광학변조기 전송선로의 전기적 특성 (Electrical Properties of Traveling-wave Coplanar Waveguide Transmission Line with a Abruptly broken Input-Output-taper for $LiNbO_3$Optical Modulator Electrode)

  • 정운조;김성구
    • 한국전기전자재료학회논문지
    • /
    • 제13권12호
    • /
    • pp.1051-1057
    • /
    • 2000
  • A traveling-wave CPW(coplanar waveguide) electrode with abruptly broken input/output-taper for LiNbO$_3$optical modulator was designed and fabricated. The electrical characteristics of traveling-wave electrode on z-cut LiNbO$_3$crystal with SiO$_2$buffer layers were measured by network analyzer. To confirm the possibility of the electro-optic modulator electrode, detailed calculations of the impedance, microwave effective index and attenuation constants are presented as a function of the microwave electrode thickness, but the buffer layer thickness is fixed as 1${\mu}{\textrm}{m}$. These characteristics are discussed from the viewpoint of the device optimization and are expected to be design guides for the LiNbO$_3$modulator’s electrodes.

  • PDF

해양 스태빙 가이드 설계 고찰 (Study on Offshore Stabbing Guide design)

  • 조철희;홍성근
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.69-77
    • /
    • 1999
  • The stabbing guide is often used to guide an add-on pile into an existing pile in offshore jacket installation. It provides a pile alignment for a welding tie-in in static condition as well. Even stabbing guide is an essential component in pile installation, it is not considered as a permanent offshore structure. In this regard, there is not a define design guideline proposed. In API RP 2A WSD, it briefly define the design considerations of stabbing guide. The failure of stabbing guide can cause a greate economical loss and a serious impact to the project schedule. Stabbing guide design should consider many factors considering actual work conditions for both static and dynamic situations. In the paper, a design method is proposed by appling the plate theory and it is confirmed numerically with FEM modeling. The geometry of stabbing guide is assumed as a cylinder shape with various wall thickness and effective length. The various thickness, effective length and pile size are compared for stable stabbing guide design.

  • PDF

벽체 내·외부에 시공한 PCM혼입 도료의 열적성능 평가에 관한 실험적 연구 (An experimental study on thermal performance evaluation of PCM mixed coating material constructed in and out of the wall)

  • 주동욱;신상헌;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.216-217
    • /
    • 2014
  • Optimum finishing position, thickness and phase change temperature of winter and summer season were selected and suitability of finishing materials was evaluated based on temperature measurement of specimens applying the coating material mixed phase change materials(PCM). As a result, when finishing position was interior and finishing thickness of coating material mixed n-Octadecane(28℃ PCM) was 4mm, thermal performance was effective. n-Octadecane in summer season and n-Hexadecane(18℃ PCM) in winter season are indicated effective on energy savings, respectively.

  • PDF