• Title/Summary/Keyword: Effective SNR

Search Result 169, Processing Time 0.025 seconds

A Study on Dose and Image Quality according to X-ray Photon Detection Method in Digital Radiography System (Digital Radiography System에서 X선 광자 검출 방식에 따른 선량 및 화질 특성에 관한 연구)

  • Hong, Sun Suk;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.247-253
    • /
    • 2013
  • The purpose is a comparative evaluation in the DR System according to the dosimetry and image quality of the quantitative and objective via Direct digital radiography, Indirect digital radiography, Image intensifier (Charge Coupled Device type) digital radiography. The experimental method used rando phantom and measured the entrance surface dose. And through using the measured entrance surface dose and then using the PCXMC program were evaluated risk due to irradiation and the effective dose. SNR and NPS and CNR were measured and analyzed by using 21cm acryl phantom. Significance of measured value was evaluated by statistics method. Entrance surface dose, major organ dose, effective dose all of them were measured the lowest rated in direct DR when it is on the basis of direct DR dose, high-dose ratio were measured in I.I DR approximately 1.3 times, indirect DR approximately 2.4 times. Risk in accordance with radiation also was measured same as dose ratio. On the conclusion that SNR measurement result based on direct DR SNR measurements, low-SNR ratio were measured in I.I DR approximately 7.25 times, indirect DR approximately 1.48 times. On the conclusion that CNR measurement result based on direct DR CNR measurements, high-dose ratio were measured in I.I type DR approximately 1.16 tims and low-dose ratio were measured in indirect DR approximately 0.87 times. Therefore Direct DR system using a-selenium sensing element to detect x-ray photon is thought effectively at the examination such as infant to sensitive irradiation and the genital gland. Because quality image is built by low dose. Also when it is necessary that image test requiring many diagnosis information, indirect DR system is thought effectively.

A Design of SINR Measurement Unit for IEEE 802.16m (IEEE 802.16m 시스템의 SINR 측정기의 설계)

  • Kim, Jun-Woo;Park, Youn-Ok;Kim, Whan-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.12A
    • /
    • pp.1097-1104
    • /
    • 2010
  • This paper presents the signal-to-noise ratio (SNR) and signal-to-interference plus noise ratio (SINR) estimation based on A-Preamble of IEEE 802.16m IMT-Advanced WiMax system with simulation results. The downlink signal of IEEE 802.16m has two kinds of A-Preambles: the PA-Preamble and the SA-Preamble. This paper proposes the effective method of estimating SNR and SINR with A-Preambles, and also shows that this method can recognize the ICI(Inter-Carrier-Interference) occurrence due to doppler frequency. With the recognition of ICI, the mobile station can save the power by operating 1-tap equalizer in usual cases, and activating ICI mitigation module only when it perceives the ICI occurrence.

Effective Adaptive Dynamic Quadrature Demodulation in Medical Ultrasound Imaging

  • Yoon, Heechul;Jeon, Kang-won;Lee, Hyuntaek;Kim, Kyeongsoon;Yoon, Changhan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.468-475
    • /
    • 2018
  • In medical ultrasound imaging, frequency-dependent attenuation downshifts and reduces a center frequency and a frequency bandwidth of received echo signals, respectively. This causes considerable errors in quadrature demodulation (QDM), result in lowering signal-to-noise ratio (SNR) and contrast resolution (CR). To address this problem, adaptive dynamic QDM (ADQDM) that estimates center frequencies along depth was introduced. However, the ADQDM often fails when imaging regions contain hypoechoic regions. In this paper, we introduce a valid region-based ADQDM (VR-ADQDM) method to reject the misestimated center frequencies to further improve SNR and CR. The valid regions are regions where the center frequency decreases monotonically along depth. In addition, as a low-pass filter of QDM, Gaussian wavelet based dynamic filtering was adopted. From the phantom experiments, average SNR improvements of the ADQDM and the VR-ADQDM over the traditional QDM were 1.22 and 5.27 dB, respectively, and the corresponding maximum SNR improvements were 2.56 and 10.58 dB. The contrast resolution of the VR-ADQDM was also improved by 0.68 compared to that of the ADQDM. Similar results were obtained from in vivo experiments. These results indicate that the proposed method would offer promises for imaging technically-difficult patients due to its capability in improving SNR and CR.

An Effective Method to Treat The Boundary Pixels for Image Compression with DWT (DWT를 이용한 영상압축을 위한 경계화소의 효과적인 처리방법)

  • 서영호;김종현;김대경;유지상;김동욱
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.6A
    • /
    • pp.618-627
    • /
    • 2002
  • In processing images using 2 dimensional Discrete Wavelet Transform(2D-DWT), the method to process the pixels around the image boundary may affect the quality of image and the cost to implement in hardware and software. This paper proposed an effective method to treat the boundary pixels, which is apt to implement in hardware and software without losing the quality of the image costly. This method processes the 2-D image as 1-D array so that 2-D DWT is performed by considering the image with the serial-sequential data structure (Serial-Sequential Processing). To show the performance and easiness in implementation of the proposed method, an image compression codec which compresses image and reconstructs it has been implemented and experimented. It included log-scale fried quantizer, but the entropy coder was not implemented. From the experimental results, the proposed method showed the SNR of almost the same SNR(Signal to Noise Ratio) to the Periodic Expansion(PE) method when the compression ratio(excluding entropy coding) of 2:1, 15.3% higher than Symmetric Expansion(SE) method, and 9.3% higher than 0-pixel Padding Expansion(ZPE) method. Also PE method needed 12.99% more memory space than the proposed method. By considering only the compression process, SE and ZPE methods needed additional operations than the proposed one. In hardware implementation, the proposed method in this paper had 5.92% of overall circuit as the control circuit, while SE, PE, and ZPE method has 22%, 21,2%, and 11.9% as the control circuit, respectively. Consequently, the proposed method can be thought more effective in implementing software and hardware without losing any image quality in the usual image processing applications.

A Study on the Optimization of Image Quality and Dose in Chest PA Digital Radiography (디지털 흉부 방사선 검사의 화질과 선량의 최적화에 관한 연구)

  • Park, Han Sol;Kim, Myeong Seong;Jung, Hong-Moon;Lee, Jong Woong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.55-61
    • /
    • 2017
  • There are no recommended test conditions for digital photography in Chest PA examinations. However, each company recommends shooting examinations of the high voltage applied to the previous analog examination. The condition that satisfies the value of 200 ~ 800 which is the recommended Exposure Index value recommended by Philips was selected, and the dose was evaluated by Monte Carlo simulation, and the SNR and CNR were compared. As a result, it was possible to reduce the effective dose up to 77% by controlling the tube voltage, tube current, and additional filter, not the conventional high voltage imaging method. Although there were some differences according to the test conditions, the image evaluation results were similar to the images. We will compare the exposure dose according to changes in tube voltage, tube current, and additional filter at the digital chest radiograph and evaluate the image quality of the image to propose optimal conditions.

A study on Gaussian mixture model deep neural network hybrid-based feature compensation for robust speech recognition in noisy environments (잡음 환경에 효과적인 음성 인식을 위한 Gaussian mixture model deep neural network 하이브리드 기반의 특징 보상)

  • Yoon, Ki-mu;Kim, Wooil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.6
    • /
    • pp.506-511
    • /
    • 2018
  • This paper proposes an GMM(Gaussian Mixture Model)-DNN(Deep Neural Network) hybrid-based feature compensation method for effective speech recognition in noisy environments. In the proposed algorithm, the posterior probability for the conventional GMM-based feature compensation method is calculated using DNN. The experimental results using the Aurora 2.0 framework and database demonstrate that the proposed GMM-DNN hybrid-based feature compensation method shows more effective in Known and Unknown noisy environments compared to the GMM-based method. In particular, the experiments of the Unknown environments show 9.13 % of relative improvement in the average of WER (Word Error Rate) and considerable improvements in lower SNR (Signal to Noise Ratio) conditions such as 0 and 5 dB SNR.

Comparison of Image Quality and Effective Dose by Additional Filtration on Digital Chest Tomosynthesis (Digital Chest Tomosynthesis에서 부가필터에 따른 화질 및 유효선량)

  • Kim, Kye-Sun;Kim, Sungchul
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.347-353
    • /
    • 2015
  • The purpose of this study is to suggest proper additional filtration by comparisons patient dose and image quality among additional filters in digital chest tomosynthesis (DTS). We measured the effective dose, dose area product (DAP) by changing thickness of Cu, Al and Ni filter to compare image quality by CD curve and SNR, CNR. Cu, Al and Ni exposure dose were similar thickness 0.3 mm, 3 mm and 0.3 mm respectively. The exposure dose using filter was decreased average about 33.1% than non filter. The DAP value of 0.3 mm Ni were decreased 72.9% compared to non filter and the lowest dose among 3 filter. The effective dose of 0.3 mm Ni were decreased 48% compared to 0.102 mSv effective dose of non filter. At the result of comparison of image quality through CD curve there were similar aspect graph among Cu, Al and Ni. SNR was decreased average 19.07%, CNR was average decreased 18.17% using 3 filters. In conclusion, Ni filtration was considered to be most suitable when considered comprehensive thickness, character, sort of filter, dose reduction and image quality evaluation in DTS.

Bit-to-Symbol Mapping Strategy for LDPC-Coded Turbo Equalizers Over High Order Modulations (LDPC 부호 기반의 터보 등화기에 적합한 고차 변조 심볼사상)

  • Lee, Myung-Kyu;Yang, Kyeong-Cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.5C
    • /
    • pp.432-438
    • /
    • 2010
  • In this paper we study the effect of bit-to-symbol mappings on the convergence behavior of turbo equalizers employing low-density parity-check (LDPC) codes over high order modulations. We analyze the effective SNR of the outputs from linear minimum mean-squared error (MMSE) equalizers and the convergence property of LDPC decoding for different symbol mappings. Numerical results show that the bit-reliability (BR) mapping provides better performance than random mapping in LDPC-coded turbo equalizers over high order modulations. We also verify the effect of symbol mappings through the noise threshold and error performance.

PCA-based Variational Model Composition Method for Roust Speech Recognition with Time-Varying Background Noise (시변 잡음에 강인한 음성 인식을 위한 PCA 기반의 Variational 모델 생성 기법)

  • Kim, Wooil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.12
    • /
    • pp.2793-2799
    • /
    • 2013
  • This paper proposes an effective feature compensation method to improve speech recognition performance in time-varying background noise condition. The proposed method employs principal component analysis to improve the variational model composition method. The proposed method is employed to generate multiple environmental models for the PCGMM-based feature compensation scheme. Experimental results prove that the proposed scheme is more effective at improving speech recognition accuracy in various SNR conditions of background music, compared to the conventional front-end methods. It shows 12.14% of average relative improvement in WER compared to the previous variational model composition method.

Improvement of the Signal-to-Noise Ratio of Photorefractive Joint Transform Correlator using Characteristics of $BaTiO_3$ ($BaTiO_3$의 특성을 이용한 광굴절 결합 변환 상관기의 신호 대 잡음비 개선)

  • 공명술;서동환;신창목;조규보;김철수;김수중
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.3
    • /
    • pp.19-32
    • /
    • 2003
  • In the conventional photorefractive joint transform correlator(PRJTC), the intensity ration of input signal-to-pump beam should be large enough to saturate two-beam coupling transfer function to obtain a desired correlation result. As a result, the signal-to-noise ratio(SNR) of correlation result is decreased in a noisy input image. In this paper, we propose the improved method for increasing the SNR of the PRJTC by using the characteristics of BaTiO$_3$. We stop the energy transfer saturating by low intensity ratio of input beam and realize a short length of effective interaction in BaTiO$_3$ by making large incident angle of the signal beam. So the gain in high frequency area is decreased and the gain in low frequency area comes up to the saturation gain of the beam coupling transfer function. Therefore the SNR is improved in noisy input image and the PRJTC can be easily realized by low intensity ratio of input beam.