• Title/Summary/Keyword: Effective Impedance

Search Result 365, Processing Time 0.038 seconds

Electrical Properties of Traveling-wave Coplanar Waveguide Transmission Line with a Abruptly broken Input-Output-taper for $LiNbO_3$Optical Modulator Electrode (급격히 꺾인 Taper를 갖는 Traveling-wave Coplanar Waveguide형 $LiNbO_34$전기광학변조기 전송선로의 전기적 특성)

  • 정운조;김성구
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.12
    • /
    • pp.1051-1057
    • /
    • 2000
  • A traveling-wave CPW(coplanar waveguide) electrode with abruptly broken input/output-taper for LiNbO$_3$optical modulator was designed and fabricated. The electrical characteristics of traveling-wave electrode on z-cut LiNbO$_3$crystal with SiO$_2$buffer layers were measured by network analyzer. To confirm the possibility of the electro-optic modulator electrode, detailed calculations of the impedance, microwave effective index and attenuation constants are presented as a function of the microwave electrode thickness, but the buffer layer thickness is fixed as 1${\mu}{\textrm}{m}$. These characteristics are discussed from the viewpoint of the device optimization and are expected to be design guides for the LiNbO$_3$modulator’s electrodes.

  • PDF

Study about MULTI MODE Measurement Algorithm For Effective Structural Monitoring System (효과적인 구조물 진단 시스템을 위한 MULTI MODE 계측법의 연구)

  • Hong, Yong;Wang, Gao-Ping;Hwang, Seung-Ho;Park, Hyun-Woo;Hong, Dong-Pyo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1382-1385
    • /
    • 2007
  • In this paper, we study about the measuring algorithm that can implement Structural Health Monitoring (SHM) more efficiently by two measurement methods using smart sensor. Through the impedance measurement method, the damage condition of structures on wide area is monitored first, and then it changes the mode to guided wave measurement mode by mode switching algorithm when impedance measurement mode detects abnormal signals. Efficient handling of the real-time data would be available by analyzing location and shape of damage through guided wave measurement.

  • PDF

Study on the Necessity for Limiting Impedance of Superconducting Fault Current Limiter Considering Protective Coordination of power distribution (배전보호협조를 고려한 초전도 한류임피던스 제한에 필요성 연구)

  • Ahn, Jae-Min;Kim, Jin-Seok;Moon, Jong-Fil;Lim, Sung-Hun;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.34-36
    • /
    • 2008
  • In this paper, we study on the necessity for limiting impedance of Superconducting Fault Current Limiter(SFCL) considering protective coordination. Several countermeasures have been proposed to protect the power system effectively from the larger fault current. Among them, the SFCL has been expected as one of the most effective solutions. However, the application of SFCL into power system can cause some problems, such as non-operation of instantaneous elements, of protective coordination because of limiting fault current. So we suggest that impedance of SFCL is must limited for operation of instantaneous elements. 'This method is essential to introduce application of SFCL into power distribution system.

  • PDF

Identification and Damping of Resonances in Inverter-based Microgrids

  • Afrasiabi, Morteza;Rokrok, Esmaeel
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1235-1244
    • /
    • 2018
  • The application of shunt capacitor banks and underground cables typically induces resonance in power distribution systems. In this study, the propagation of resonance in a microgrid (MG) with inverter-based distributed generators (IBDGs) is investigated. If resonances are not properly damped, then the output current of the inverters may experience distortion via resonance propagation due to the adverse effect of resonances on MG power quality. This study presents a conceptual method for identifying resonances and related issues in multi-inverter systems. For this purpose, existing resonances are identified using modal impedance analysis. However, some resonances may be undetectable when this method is used. Thus, the resonances are investigated using the proposed method based on the frequency response of a closed-loop MG equivalent circuit. After analyzing resonance propagation in the MG, an effective virtual impedance damping method is used in the IBDG control system to damp the resonances. Results demonstrate the effectiveness of the proposed method in compensating for existing resonances.

Calculation of Electric Potential Rise of Horizontal Grounding Electrode Caused by Lightning Stroke Currents (뇌격전류에 의한 수평접지극의 전위상승 계산)

  • Lee, Bok-Hee;Cho, Sung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.12
    • /
    • pp.81-86
    • /
    • 2013
  • An electric potential rise of the grounding electrode developed by the lightning stroke currents should be calculated for the purpose of effective protection of electrical and electronic equipment. In this paper, the electromagnetic model was applied to calculate the harmonic impedance of grounding electrode. Also the empirical equation related to the permittivity and resistivity of soil was used. The lightning current waveforms, which are expressed by the Heidler's equation, were used in order to calculate accurately transient electric potential rises. The transient voltage was obtained by using the simulated harmonic impedance and the lightning current in frequency domain. Finally, the transient voltages of horizontal grounding electrode(10m) under lightning stroke currents were calculated by IFFT(Inverse Fast Fourier Transform).

An Effective Fault Analysis Method in Large Scale Power System (대전력계통의 고장해석에 관한 효추적인 계산방법에 관한 연구)

  • Jai-Kil Chung;Gi-Sig Byun
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.32 no.12
    • /
    • pp.435-440
    • /
    • 1983
  • The methods of forming the bus impedance matrix, which is mainly employed in fault analysis of power system, can be generally classified in catagories, (1) the one being the inverse matrix of bus admittance matrix, and (2) the other the bus impedance matrix succesive formation method by particular algorithms. The former method is theouetically elegant, but the formation and inverse of complex bus admittance matrix for large power system requires too much amounts of computer memory space and computing time. The latter method also requires too much memory space. Therefore, in this paper, an algorithm and computer program is introduced for the formation of a sparse bus impedance matrix which generates only the matching terms of the admittance matrix. So, this method can reduce the computer memory and computing time, and can be applied to fault analysis of large power system by small digital computer.

A Study on the Algorithm for Fault Discrimination in Transmission Lines using Neural Network and the Variation of Fault Currents (신경회로망과 고장전류의 변화를 이용한 고장판별 알고리즘에 관한 연구)

  • Yeo, Sang-Min;Kim, Cheol-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.8
    • /
    • pp.405-411
    • /
    • 2000
  • When faults occur in transmission lines, the classification of faults is very important. If the fault is HIF(High Impedance Fault), it cannot be detected or removed by conventional overcurrent relays (OCRs), and results in fire hazards and causes damages in electrical equipment or personal threat. The fast discrimination of fault needs to effective protection and treatment and is important problem for power system protection. This paper propolsed the fault detection and discrimination algorithm for LIFs(Low Impedance Faults) and HIFs(High Impedance Faults). This algorithm uses artificial neural networks and variation of 3-phase maximum currents per period while faults. A double lines-to-ground and line-to-line faults can be detected using Neural Network. Also, the other faults can be detected using the value of variation of maximum current. Test results show that the proposed algorithms discriminate LIFs and HIFs accurately within a half cycle.

  • PDF

The Design of a Power Supply for Planer Type of the Dielectric Barrier Discharge Ozone Reactor with Impedance Matching (유전체 장벽 방전을 이용한 오존 발생기의 전원장치 최적 설계 및 비교)

  • Kim, Bong-Seong;Shin, Young-Chul;Ko, Kwang-Cheol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.1
    • /
    • pp.57-63
    • /
    • 2011
  • Dielectric Barrier Discharge (DBD) reactor with sinsodual AC type of power supply is very widely adopted for its compact size and effective discharging mechanism to generate high density of ozone radicals. However, at the aspect of design on power supply, its optimal switching conditions and topology is achieved by empirical test. Therefore, throughout this paper, it is proposed a design method of DBD power supply to guarantee a maximum ozone yield rate in accordance with DBD reactor modification and impedance variation when rapid gas discharging in the DBD reactor is proceeded.

Development of a Battery Monitoring Technology using Its Impedance (임피던스를 이용한 배터리 모니터링 기술)

  • Shim, Jae-Hong;Kim, Jae-Dong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.4
    • /
    • pp.25-29
    • /
    • 2011
  • Emerging demands for rechargeable battery for various applications needs more effective battery management system such as the prediction of the usable time about a battery. Many prediction methods have been suggested but none of them come into bounds of reliability. In this paper, we proposed a new prediction algorithm for the remaining capacity of a rechargeable battery by using the transformed curve based on its impedance. Hardware for monitoring a battery was designed and made. Through a series of experiment, we showed the effectiveness of the proposed prediction algorithm of a battery's remaining capacity.

The transient grounding impedance measurment of large grid grounding electrodes (대규모 그리드 접지전극의 과도접지임피던스의 측정)

  • Jeon, Byung-Wook;Lee, Su-Bong;Li, Feng;Lee, Seung-Ju;Jung, Dong-Cheol;Lee, Bok-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.69-72
    • /
    • 2008
  • This paper presents the transient and conventional grounding impedance behaviors of large grid grounding system associated with the injection point of impulse current The measurement methods consider two possible errors in the grounding-system impedances: (1) ground mutual resistance due to current flow through ground from the ground electrode to be measured to the current auxiliary, (2) ac mutual coupling between the current test lead and the potential test lead The test circuit was set to reduce the error factors. The transient grounding impedance depends on the rise time and injection point of impulse current It is effective that grounding conductor is connected to the center of the large grid grounding system.

  • PDF