• 제목/요약/키워드: Effective Impedance

검색결과 366건 처리시간 0.032초

유체의 흐름이 있는 엔진 흡기계용 직조관의 음향 임피던스 측정 및 전달손실 예측 (Measurement of acoustic impedance of porous woven hoses in engine intake systems in the presence of mean flow)

  • 이정권;박철민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.996-1000
    • /
    • 2002
  • A porous tube, comprised of a resin-coated woven fabric has recently been used as an effective component for use in intake systems of internal combustion engines to reduce the intake roaring. For the prediction of the acoustic performance of an engine intake system with a porous woven hose, the acoustic wall impedance of the hose must be known. Because of its peculiar acoustical and structural characteristics, the accurate measurement of the wall impedance ofa porous woven hose is not easy. A new measurement technique is proposed herein, that is valid over the low to mid frequency ranges. The acoustics impedance is inversely estimated from an overdetermined set of measured pressure transmission coefficients for specimens of different lengths and the reflection coefficient of end termination. The method involves only one measurement, and, as a result, it is very simple. The measured TL for samples with arbitrary conditions, arbitrary porous frequency, arbitrary length, and arbitrary mean flow condition, are in reasonably good agreement with values predicted from curve-fitted impedance data.

  • PDF

SPT 동적신호를 이용한 지반정보 추정에 관한 해석적 연구 (Analytical Studies for Estimating Soil Properties from the SPT Dynamic Signals)

  • 이병식;김영수;김범상
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.423-430
    • /
    • 2002
  • A feasibility of a trial test method was evaluated analytically, in which the elastic modulus of a soil deposit was tried to estimate by analyzing dynamic signals measured during conducting the SPT. If there existed a reliable relationship between the impedance ratio of a rod to a soil and the amplitude ratio of a reflected to an incident wave signal at the tip of steel rod contacting the soil surface, it was expected that one could determine the impedance of soil, and then roughly estimate the elastic modulus from the impedance. For a simple rod-soil system, the existence of the relevant relationship was verified in this study by analyzing computed wave signals propagating up and down through the rod. On the basis of these results, thus, a potential of the test method to practical applications could be seen. However, apparent theoretical shortcomings possessed in this approach were also realized since the soil part had an unconfined contact area where contacted with the rod. Therefore, it was concluded that further studies needed to be conducted, in which the reliable theoretical relationship between the impedance and the amplitude ratio as well as the effective contacting soil area contributing to wave reflection should be justified.

  • PDF

Correlations between the Impedance and Compressive Strength of Hardened Cement According to the Aggregate Type

  • Hojin Kim;Jinju Kim;Sungyu Park;Je Hyun Bae
    • Journal of Electrochemical Science and Technology
    • /
    • 제15권2호
    • /
    • pp.242-252
    • /
    • 2024
  • To date, methods used to assess the interfacial transition zone (ITZ), which represents the boundary between the aggregate and paste inside concretes, have primarily relied on destructive tests, and non-destructive tests has received little attention until recently. This study assessed the interfaces of concretes with lightweight aggregates based on electrochemical impedance spectroscopy (EIS) for high-strength concretes and examined the possibility of estimating the compressive strength of concretes through non-destructive testing using EIS. The experimental results revealed that the impedance of the hardened cement increased with increasing compressive strength and aggregate density. In particular, when the results of impedance measurement were displayed as a Nyquist plot, the intercept of the x-axis depicting the effective conductivity was proportional to the compressive strength. Furthermore, an equivalent circuit was selected to interpret the correlation between cement aggregates and impedance. Consequently, the compressive strength was found to increase with the value of the resistances of the electrolyte filled in continuous pores in the cement aggregate. And, the pores formed in the ITZ affect this value. The resistance at the ITZ for different aggregates was also obtained, and it was found that the resistance was consistent with the results predicted by SEM images of the ITZ and correlated with the strength of the concretes. The proposed method can be used as a way to easily determine the strength of cement according to differences in aggregate.

수중 음향재료의 음향성능 설계기법 연구 (A Study on the Acoustic Performance Design Technique of Underwater Acoustic Material)

  • 서영수;함일배;전재진
    • 한국소음진동공학회논문집
    • /
    • 제23권10호
    • /
    • pp.920-927
    • /
    • 2013
  • The requirement of acoustic performance about underwater acoustic material which is used in underwater environment more increases. Underwater acoustic material was made by viscoelastic material such as a rubber and a polyurethane etc. In order to increase an acoustic performance, several kinds of inclusions were added to viscoelastic material. In this paper, acoustic modelling and analysis techniques were introduced and the acoustic characteristics of underwater acoustic material were studied. Echo reduction and transmission loss were calculated with volume fraction of inclusion in the material. Also the characteristic impedance and the input impedance of underwater acoustic material were obtained and effects on the echo reduction and transmission loss of material were discussed.

비파괴 검사용 초음파 탐촉자에서의 정합층 최적 설계법 (Design Method for the Optimized Acoustic Matching Layers of UT Probes)

  • 박치승;김선진
    • 한국재료학회지
    • /
    • 제13권10호
    • /
    • pp.658-662
    • /
    • 2003
  • In this study, we have tried to find the optimized design variables of the matching layer which is important part of thickness mode ultrasonic transducer and finally reach the conclusion that the electrical property of piezo-element must be under consideration when the optimized acoustic impedance is estimated. Proper expression of the effective impedance of front load at free resonant frequency(: $Z_{f}$ $^{(0)}$ /) has been induced by introducing the principle of binomial multilayer transformer and gradient based numerical method is utilized to find the most acceptable value of $Z_{ f}$/$^{(0)}$ . Optimized point of acoustic impedance can be calculated directly from $Z_{f}$ $^{(0)}$ using some simple formula which we propose. We also verify our result by both numerical and experimental method and get a good enhancement especially it concern to the bandwidth of ultrasonic transducer.

생체 전기 신호에 의한 효율적인 생체 신호 측정 (Effective Body Signal Measurement with the Bioelectric Impedance Analysis)

  • 오세용;황대석;이영우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 춘계종합학술대회
    • /
    • pp.955-958
    • /
    • 2005
  • 생체 전기 임피던스법(Bioelectrical Impedance Analysis, BIA)은 신체의 체수분량을 측정하고 이를 바탕으로 체지방량을 측정할 수 있다. 여기에 사용된 상관식은 FFM=-4.104+0.518H+0.231W+0.130X+4.229S를 사용하였다. 여기서 H는 신장, R은 저항값, W는 체중, X는 리액턴스이고 S는 성별이다.

  • PDF

효율적인 생체 임피던스 신호 측정에 관한 연구 (Effective Body Signal Measurement with the Bioelectric Impedance Analysis)

  • 오세용;이영우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 추계종합학술대회
    • /
    • pp.689-692
    • /
    • 2005
  • 생체 전기 임피던스법(Bioelectrical Impedance Analysis, BIA)은 신체의 체수분량을 측정하고 이를 바탕으로 체지방량을 측정할 수 있다. 이를 효율적으로 측정하기 위해서 4개의 전극을 손바닥에 위치 시키고 전류(50kHz, 800uA)를 신체에 흘려 보내 전압과 캐패시턴스를 측정하고 기본 파라미터인 키, 몸무게, 나이와 성별을 입력하여 체지방량을 측정하는 방법을 제안하였다.

  • PDF

인하도선 길이에 따른 과도접지임피던스 특성 (Effects of Length of Down Conductor on Transient Ground Impedance)

  • 이복희;정동철;이수봉;이태형;정현욱;이규선;이승칠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2235-2237
    • /
    • 2005
  • This paper presents the transient impedance behaviors of grounding systems to lightning impulse current. The potential rise and effective impulse ground impedance of the test grounding electrodes were measured as a function of the rise time of impulse currents and lengths of down conductor. The transient ground impedances strongly depend on the configuration and size of grounding electrodes, the impulse current shapes and lengths of down conductor, and the inductance of reduce of grounding electrode inductance is an important factor to improve the transient ground impedance.

  • PDF

Development of a Practical Two-Microphone Impedance Tube Method for Sound Transmission Loss Measurement of Sound Isolation Materials

  • Ro, Sing-Nam;Hwang, Yoon;Lee, Dong-Hoon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권3호
    • /
    • pp.105-113
    • /
    • 2003
  • This study developed a practical two-microphone impedance tube method to measure the sound transmission loss of sound isolation materials without the use of an expensive reverberation room or an acoustic intensity probe. In order to evaluate the validation and applicability of the two-microphone impedance tube method, sound transmission losses for several sound isolation materials with different surface density and bending stiffness were measured, and the measured values were compared with the results from the reverberation room method and the theory. From the experimental results, it was found that the accuracy of sound transmission loss obtained by the impedance tube method depends upon the diameter size of the impedance tube (i.e., tested sample size). For sound isolation materials having relatively large bending stiffness such as acryl, wood, and aluminum plates, it was found that the impedance tube method proposed by this study was not valid to measure the sound transmission loss. On the other hand, for sound isolation materials having relatively small bending stiffness such as rubber, polyvinyl, and asphalt sheets, the comparisons of transmission loss between the results from the impedance tube method and the theory showed a good agreement within the range of the frequencies satisfying the normal incidence mass law. Therefore, the two-microphone impedance tube method proposed by this study can be an effective measurement method to evaluate the sound transmission loss for soft sound isolation sheets having relatively small bending stiffness.

가정용 전기기구의 효과적인 뇌서지 보호기법 (Effective Protection Methods of Household Electric Appliances. from Lightning Surges)

  • 이복희;강성만;엄주홍;이수봉;길형준;구본완;안창환
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권3호
    • /
    • pp.149-156
    • /
    • 2004
  • This paper deals with the effective protection method for the household electric appliances against lightning surges invading from the Power lines. Direct or induced lightning is the main cause of the breakdown of household electric appliance. The most effective protection method is to install SPDs(surge protective devices) at household electric appliances. If SPDs were not installed at most household electric appliances, it is necessary to install SPDs on the mains. Therefore the propagation aspect and protection methods of lighting surges coming into household electric appliances through the mains was experimentally investigated. The in actual-sized test circuits results of protection method for 8 household electric appliances including computer monitors and TV set could be summarized as follows: The breakdown characteristics of household electric appliances from lightning surges were significantly changed with the their input impedance. Namely, the types of input impedance are classified into infinite, resistive or inductive impedances. Especially, the monitor for computer with inductive input impedance from lightning surges was relatively weak against lightning surges. It was confirmed that the self inductance of branch circuits on the mains have protection effect for household electric appliances against lightning surges invading from the power lines. Also the varistors installed at cabinet panel or circuit-breaker were more effective than multi-tap outlet with varistors. When installed varistors in cabinet panel and multi-tap outlet together, the surge protection effect is much more excellent in technical and economical aspects.