• Title/Summary/Keyword: Effective Impedance

Search Result 366, Processing Time 0.035 seconds

Analysis of Dynamic Behavior of Piezoelectric Atomic Force Microscope Cantilever (압전형 AFM 외팔보의 동적거동 해석)

  • 하성규;박성균;김영호
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.3
    • /
    • pp.187-194
    • /
    • 2002
  • A seven-port impedance and admittance matrices of multilayered piezoelectric beam are derived for the analysis of piezoelectric AFM ( atomic force microscope) cantilever that is partially covered by the piezoelectric layer. The variational principle is used for deriving the extensional and flexural motional equations and the conjugate parameters. Overall impedance matrix of AFM cantilever can be obtained by combining two impedance matrices of the covered and the non-covered. she resonance and antiresonance frequencies and the effective electromechanical coupling factors are calculated using the derived matrices. The results and the three dimensional finite element solutions are compared with the experimental results in other publication.

Permittivity Adjustment and Impedance Matching of Ferrite Composite Microwave Absorber (복합 Ferrite 전파흡수체의 유전율 제어 및 임피던스 정합)

  • 최경구;조성백;권경일;김성수;김재묵
    • Journal of the Korean Ceramic Society
    • /
    • v.29 no.4
    • /
    • pp.293-297
    • /
    • 1992
  • A proper combination of complex permeability and permittivity is necessary to produce the zero-reflection microwave absorber with an impedance matching. Increasing of dielectric permittivity and development of an impedance matching was investigated in ferrite-rubber composite specimens by addition of conducting materials. Graphite powder of high dielectric constant was added to the composite specimens to increase the permittivity. The precise estimation of graphite content to produce the matched-wave-impedance absorber at a given frequency can be made by using the numerically derived solution map of impedance matching. It was suggested that permittivity adjustment is an effective technique to obtained the microwave absorber with both good absorbing properties and small thickness as well.

  • PDF

Calculation of the Area of Vulnerability to Voltage Sags by using Impedance Building Algorithm (임피던스 행렬 구성법을 이용한 순간전압강하 취약지역의 계산)

  • Park, Jong-Il;Park, Chang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.1
    • /
    • pp.44-53
    • /
    • 2012
  • This paper presents a method to calculate the area of vulnerability by using the impedance building algorithm. The installation of DG (Distributed Generation) is one of the countermeasures against voltage sags in power systems. In order to estimate the effect of the DG, the voltage sag assessment should be performed based on the area of vulnerability and system fault statistics. To determine the area of vulnerability, system impedance matrix should be calculated. The calculation of the impedance matrix of large systems is time-consuming task. This paper addresses an effective scheme to calculate the area of vulnerability and system impedance matrix.

Friction Compensation for Impedance Control of Pneumatic Manipulator (공압매니퓰레이터의 임피던스제어를 위한 마찰보상법)

  • Park, Jung-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.2
    • /
    • pp.252-260
    • /
    • 1997
  • In this paper, a friction compensation method using a disturbance observer is proposed for an impedance control of pneumatic manipulator. It is assumed that the generated torque by a pneumatic actuator can be estimated based on the pressure signals and the discharge volume. In order to improve the dynamic characteristics of the pneumatic actuator driven by meter out method, we construct the inner torque control system by feeding back the generated torque. In order to reduce the influence of disturbances comprising friction torque and parameter variations of plant, the impedance control system is constructed with a disturbance observer which estimates the disturbances based on the generated torque of pneumatic actuator, the angular velocity and the reaction torque. From some experiments, it is confirmed that the proposed control system is effective to improve the robustness for the friction torque in the impedance control of a pneumatic manipulator.

Development of Ground Impedance Measuring Instrument for Lightning Protection System (뇌보호 설비를 위한 접지임피던스 측정기 개발)

  • Lee, Tae-Hyung;Cha, Sung-Chul;Earn, Ju-Hang
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.194-195
    • /
    • 2006
  • This study evaluated the impedance characteristics of earth termination system and developed a variable frequency-typed inverter (measuring tool) for the utilization in ground design for lightning protection. The variable-frequency-typed inverter were composed of rectification part, voltage adjuster, IGBT controller and measuring part. Meanwhile, the square wave signal of variable frequency converted its frequency up to lightning surge band by using an IGBT after rectifying an alternating current (AC). It conducted performance evaluation of ground impedance of actual earth termination system by using the developed measuring tool for ground impedance and confirmed that such impedance-oriented performance evaluation was effective in the design of lightning protection.

  • PDF

Ground Impedance and Frequency Response Characteristics of Large-scale Ground Rods (대형 봉상 접지전극의 접지임피던스와 주파수 응답특성)

  • Lee, Bok-Hee;Eom, Ju-Hong;Kim, Tai-Doo;Chung, Dong-Chul;Kil, Hyeong-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1791-1793
    • /
    • 2003
  • In order to analyze the dynamic characteristics of ground impedance in large grounding system for lightning and surge protections, a novel method for measuring the ground impedance as a function of frequency was proposed. The experiments were carried out in the grounding system composed of ground rods and mesh grids. The test current was injected by the variable frequency inverter whose frequency is linearly controlled in the range of $5{\sim}500$kHz. The ground impedance and frequency response of the grounding system were mainly caused by the inductive current flowing through grounding conductors over the frequency of 2002. In the combined grounding system of rods and mesh grids, inductive component of ground impedance was significantly decreased. It was fumed out that the grounding system is effective for the surge protection.

  • PDF

Computation of Underwater Acoustic Field Using Acoustic Impedance as an Input Parameter for the Ocean Bottom (음향 임피던스를 해저면 입력인자로 이용하는 수중음장 계산)

  • Lee Seongwook;Oh Taekhwan;Na Jungyul;Lee Phil-Ho;Yoon Jong Rak
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • The Possibility of using acoustic impedance as an input Parameter for computation of underwater acoustic field in shallow waters was investigated. Analysis of the acoustic reflection from the ocean bottom with shear wave effect showed that acoustic impedances below the critical grazing angle have nearly angle-independent property and could be approximated with a single value of near-grazing impedance $Z_0$. Computations of the Propagation loss based on the concept of 'effective depth' indicate that near-grazing bottom acoustic impedances could be used as an input parameter for simulation of the acoustic fields in shallow waters.

Design and Fabrication of High Frequency Ground Impedance Measuring System for Assessment of Grounding System for Lightning Protection (낙뢰 보호용 접지시스템 평가를 위한 고주파 접지임피던스 측정시스템의 설계 및 제작)

  • Gil, Hyoung-Jun;Shong, Kil-Mok;Kim, Young-Seok;Kim, Chong-Min;Kim, Young-Jin
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.3
    • /
    • pp.47-52
    • /
    • 2016
  • This paper describes the design and fabrication of high frequency ground impedance measuring system for assessment of grounding system for Lightning protection. The ground impedance measuring system has been designed and fabricated which makes it possible to assess the ground impedance by frequency ranges from 100 Hz to 1 MHz. The effective grounding systems having a very low impedance to electromagnetic disturbance such as lightning surges and noises in microelectronics and high-technology branches are strongly required. In order to analyze the dynamic characteristic of grounding system impedances in lightning and surge protection grounding systems, it is highly desirable to assess the ground impedances as a measure of performance of grounding system in which lightning and switching surge currents with fast rise time and high frequency flow. The measuring system is based on the variable frequency power supply and consists of signal circuit part, main control part, data acquisition and processing unit, and voltage and current probe system. The ground impedance measuring system can be used to assess grounding system during occurrence of lightning.

Transient Grounding Impedance Behaviors of Deeply-driven Ground Rods According to the Injection Point of Impulse Currents (임펄스전류의 인가위치에 따른 심매실 봉상 접지전극의 과도접지임피던스 특선)

  • Lee, Su-Bong;Li, Feng;Lee, Seung-Ju;Jeon, Byung-Wook;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.62-68
    • /
    • 2008
  • This paper presents the transient and conventional grounding impedance behaviors of deeply-driven ground rods associated with the injection point of impulse currents. The transient grounding impedance strongly depends on the length of deeply-driven ground rod and the rise time and injection point of impulse currents, and the intrinsic inductance of ground rod has a significant affect on the transient grounding impedance of grounding system in fast rise time ranges. The reduction of inductance is decisive to improve the impulse impedance behaviors of deeply-driven ground rods. It is effective that grounding conductor is connected to the top of the ground rod as short as possible.

Effective impulse impedances of a deep-driven ground rod combined with other grounding electrodes (다른 형상의 접지전극에 접속된 심매설 접지전극의 실효임펄스임피던스)

  • Lee, Bok-Hee;Chang, Keun-Chul;Lee, Su-Bong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.565-569
    • /
    • 2004
  • This paper deals with the characteristics of potential rise and effective impulse impedance of deep-driven ground rods that are used in high resistivity soil or in confined places such as downtown. Also the effects of the impulse and fault currents on the deep-driven ground rods combined with different type grounding electrodes like as mesh grids and counterpoises are described. The $8/20{\mu}s$ impulse current and other wave currents with different rise times are injected into the test ground rod and the effective impedances are examined. The most effective way to obtain the fine transient impedance behaviors of deep-driven ground rods is to reduce the inductive component of grounding electrode systems combined with other ground electrodes.

  • PDF