• Title/Summary/Keyword: Effective Concentration

Search Result 5,481, Processing Time 0.039 seconds

Prediction for the Lifetime Effective Dose and Radon Exposure Risk by using Dose Conversion Convention: Base on the Indoor Radon Concentration of Lecture Room in a University (선량 환산 관례를 이용한 생애유효선량 및 라돈피폭 위험도 예측: 대학 강의실 라돈농도 중심으로)

  • Lee, Jae-Seung;Kweon, Dae Cheol
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.243-249
    • /
    • 2018
  • The indoor radon concentration was measured in the lecture room of the university and the radon concentration was converted to the amount related to the radon exposure using the dose conversion convention and compared with the reference levels for the radon concentration control. The effect of indoor radon inhalation was evaluated by estimating the life effective dose and the risk of exposure. To measure the radon concentration, measurements were made with a radon meter and a dedicated analysis Capture Ver. 5.5 program in a university lecture room from January to February 2018. The radon concentration measurement was carried out for 5 consecutive hours for 24 hours after keeping the airtight condition for 12 hours before the measurement. Radon exposure risk was calculated using the radon dose and dose conversion factor. Indoor radon concentration, radon exposure risk, and annual effective dose were found within the 95% confidence interval as the minimum and maximum boundary ranges. The radon concentration in the lecture room was $43.1-79.1Bq/m^3$, and the maximum boundary range within the 95% confidence interval was $77.7Bq/m^3$. The annual effective dose was estimated to be 0.20-0.36 mSv/y (mean 0.28 mSv/y). The life-time effective dose was estimated to be 0.66-1.18 mSv (mean $0.93{\pm}0.08mSv$). Life effective doses were estimated to be 0.88-0.99 mSv and radon exposure risk was estimated to be 12.4 out of 10.9 per 100,000. Radon concentration was measured, dose effective dose was evaluated using dose conversion convention, and degree of health hazard by indoor radon exposure was evaluated by predicting radon exposure risk using nominal hazard coefficient. It was concluded that indoor living environment could be applied to other specific exposure situations.

Ecotoxicity Assessment of Potassium Hydrogen Phthalate and Verification of Standard Reference Toxicity Test Method Using Potassium Hydrogen Phthalate

  • Dong Jin Choi
    • Proceedings of the National Institute of Ecology of the Republic of Korea
    • /
    • v.4 no.1
    • /
    • pp.49-62
    • /
    • 2023
  • Phthalates are animal carcinogens. Potassium hydrogen phthalate (KHP), which has the least complicated structure among phthalates, is used for the analysis of total organic carbon and formaldehyde. However, its toxicity has not been confirmed. A 24-hour acute toxicity test was performed using Daphnia magna, a water flea used to evaluate aquatic toxicity owing to its high sensitivity. The lowest observed effect concentration of KHP was found to be 240 mg/L. The effects of phosphorus, nitrogen, and Cr(6+), which are able to be discharged along with KHP, were also confirmed using tests. At 240 mg/L KHP, toxicity increased as phosphorus, nitrogen, and Cr(6+) increased. In addition, tests were performed to confirm the half maximal effective concentration of KHP. Through 10 test repetitions, the average ecotoxicity value was found to be 0.3, the average half maximal effective concentration was 327.75 mg/L, and the coefficient of variation (%) was 3.16%; because the latter value is lower than 25%, which is what is generally suggested for the water pollution standard method, the reproducibility of the tests is sufficient to replace the existing standard reference toxicity test that uses potassium dichromate. In addition, the half maximum effective concentration of potassium hydrogen phthalate is approximately 218 times more than that of potassium dichromate; therefore, toxicity is relatively low. In conclusion, KHP is a feasible alternative to the highly toxic potassium dichromate for performing the standard reference toxicity test.

Anti-static behavior of Synthetic fabrics treated by anti-static agents (대전방지처리된 합성섬유의 대전성에 관한 연구)

  • Choi Suk-Chul;Kim Mi-Sung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.11 no.1
    • /
    • pp.51-62
    • /
    • 1987
  • In this study, electrostatic behavior of polyester and nylon fabric treated with anti-static agents were investigated. The effects of the concentration of the agents and curing conditions on the electrostatic charge of the fabrics were studied. And washfastness, lightfastness and physicalproperties of the treated fabrics were also investigated. The results were as follows: 1) Polyethylene glycol alkylester was more effective in antistatic behavior than polyethylene laurylphosphate, and polyester is more effective in anti-static behavior than nylon. 2) Concentration of anti-static agents were suitable in concentration of $4\%$. 3) Glyoxal resin was more effective in anti-static behavior than melamine resin, and it was also good in the retaing anti-static behavior after treatments of lightfastness and washfastness. 4) As the condition of curing treatment, $190^{\circ}C$, 1min. for glyoxal resin and $130^{\circ}C$, 4min. for melamine resin is appropriate. 5) In comparison of anti-static behavior according to treating conditions, the simultaneous treatment was more effective than any other treatments. 6) Change of electrostatic charge of anti-static nylon cloths after treatments of lightfastness and washfastness increased greatly in above 10 laundering time and 20 fade-O-meter time. 7) In physical properties according to concentration of treating agents. decrease of physical properties scarcely appeared in concentration of treating agents $4\~5\%$.

  • PDF

Indoor Radon Levels and Effective Dose Estimation in Learning and Common Living Space of University (대학 내 학습공간과 공동 생활공간에 대한 실내 라돈 농도 측정과 유효선량 산출)

  • Kim, Jung-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.329-334
    • /
    • 2018
  • Radon which is natural component of air is a colorless and odorless radioactive gas. Radon exposure can also occur from some building materials if they are made from radon-containing substances by breathing. In this study, The radiation dose of radon concentration was detected at 8 buildings of the A university during 3-month from June. 2017 to August. 2017. We detected indoor radon exposure at 8 building of the university and estimated annual effective dose. The radon concentration of Hall G and Hall F of the A university represented 81 and $14Bq/m^3$ respectively and average indoor radon concentration represented $41.63Bq/m^3$. Average effective dose was estimated 0.40 mSv/y, maximum effective dose was 0.78 mSv/y and minimum effective dose was 0.13 mSv/y respectively. University is the place that students spend the almost whole time. We suggest ventilation and appropriate management of a building, which could reduce the natural radiation exposure by radon concentration.

Double-Diffusive Convection in a Salt-Stratified Fluid Heated From Below (농도 성층화된 유체의 아랫면 가열에 의한 이중확산대류에 관한 연구)

  • 강신형;김무현;이진호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.12
    • /
    • pp.3297-3304
    • /
    • 1994
  • Experimental investigation have been made to study the double-diffusive nature of convection of an initially stratified salt-water solution heated from below in a cylindrical cavity. The objective is to examine the process of mixed-layer formation, the flow phenomena, the heat transfer characteristics, and temperature and concentration distribution according to the changes in the effective Rayleigh number based on the reference height which represents the relation of temperature and concentration gradient. The types of initially formed flow pattern are categorized in three regimes depending on the effective Rayleigh number ; stagnant flow regime, single mixed-layer flow regime and successively formed multiple mixed-layer flow regime. The temperature and concentration profiles are both uniform in each layer due to convective mixing in the layered flow regime, but both linear in stagnant flow regime and single mixed-layer flow regime. At the interface between adjacent layers, the temperature changes smoothly but the concentration changes rapidly. The layers expand by diffusion of concentration through the interface along with its random fluctuation.

Effective Thermal Conductivities of Al203 Nanoparticles Suspended in Water with Low Concentration less than 1 Vol. % (1%미만의 부피비를 가지는 알루미나 나노유체의 유효 열전도도)

  • Hwang, Kyo-Sik;Lee, Byeong-Ho;Kim, Jun-Ho;Jang, Seok-Pil
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.15 no.3
    • /
    • pp.1-5
    • /
    • 2007
  • In this paper, effective thermal conductivities of water-based Al203-nanofluids with low concentration from 0.01 vol. % to 0.3 vol. % are experimentally obtained by transient hot wire method (THWM). The water-based Al203-nanofluids are manufactured by two-step method which is widely used. To examine suspension and dispersion characteristics of the water-based A1203-nanofluids, Zeta potential as well as transmission electron micrograph (TEM) is observed. We confirm the manufactured Al203-nanofluids have good suspension and dispersion. The effective thermal conductivities of the water-based Al203-nanofluids with low concentration are enhanced up to 1.64% compared with that of DI water at $21^{\circ}C$. In addition, experimental results are compared with theoretical results from Jang and Choi model.

  • PDF

Pathogenicity of Entomopathogenic Nematodes to Some Agro-Forest Insect Pests (농림해충에 대한 곤충병원성 선충의 병원성)

  • 이상명;이동운;추호렬;김도완;김준범
    • The Korean Journal of Soil Zoology
    • /
    • v.2 no.2
    • /
    • pp.76-82
    • /
    • 1997
  • Mortality of some agro-forest insect pests, Agrotis segetum, Blitopertha orientalis, Agerastica coerulea, Glyphodes perspectalis and Acantholyda parki caused by entomopathogenic nematodes was investigated in laboratory and in pot. Steinernema carpocapsae All and Pocheon strain were effective against 2nd of 3rd instar larvae of A. segetum showing 100% mortalities at the concentration of 10Ijs/larva but not effective against 4th inster larvae. Mortality of B. orientalis was 100% after 26 days in H. bacteriopora NC 1, H. bacteriophora Hamyang and S. glageri NC strain treatment. S. monticulum also showed 100% mortalities against A. coerulea andd G. perspectalis at the concentration of 80 and 40 Ijs/larva. However, H. bacteriophora Cheju and S. glaseri Cheju strain were not effective against A. parki, i.e., showing 23.3 and 20.0% mortalities, respectively at the concentration of 160Ijs/larva. S. glaseri Hanrim strain was more effective than H. bacteriophora Cheju strain against Pryeria sinica.

  • PDF

Effect of Several Zinc Solutions on Concentration of Oral Volatile Sulfur Compounds(VSCs) (수종의 Zinc 수용액이 구강내 휘발성 황화합물의 농도에 미치는 영향)

  • Park, Moon-Soo;Han, Song
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.1
    • /
    • pp.1-7
    • /
    • 2000
  • The purpose of this study is to investigate effects of several zinc solutions including Artemisia asiatica-containing zinc solution on concentration of oral volatile sulfur compounds(VSCs). We determined the VSCs concentration of breath of human subjects before and after use of zinc solutions(O.25% $ZnF_2$ Artemisia asiatica-containing 0.25% $ZnCl_2$ and Artemisia asiatica-containing 0.25% $ZnCl_2$ solutions) The results were as follows : 1. 0.25% $ZnCl_2$ solution was more effective than 0.25% $ZnF_2$ solution in reducing the concentration of oral VSCs and the maintenance duration of effectiveness. 2. Artemisia asiatica-containing 0.25% $ZnCl_2$ solution was more effective than Artemisia asiatica-containing 0.25% $ZnF_2$ solution in reducing the concentration of oral VSCs and the maintenance duration of effectiveness. 3. Artemisia asiatica-containing 0.25% $ZnF_2$ solution and 0.25% $ZnF_2$ solution showed no significant difference in reducing the concentration of oral VSCs and the maintenance duration of effectiveness but, Artemisia asiatica-containing 0.25% $ZnF_2$ solution was slightly more effective. 4. Artemisia asiatica-containing 0.25% $ZnCl_2$ solution and 0.25% $ZnCl_2$ solution showed no significant difference in reducing the concentration of oral VSCs and the maintenance duration of effectiveness but, Artemisia asiatica-containing 0.25% $ZnF_2$ solution was slightly more effective.

  • PDF

High concentration ratio approximation of linear effective properties of materials with cubic inclusions

  • Mejak, George
    • Coupled systems mechanics
    • /
    • v.7 no.1
    • /
    • pp.61-77
    • /
    • 2018
  • This paper establish a high concentration ratio approximation of linear elastic properties of materials with periodic microstructure with cubic inclusions. The approximation is derived using first few terms of power series expansion of the solution of the equivalent eigenstrain problem with a homogeneous eigenstrain approximation. Viability of the approximation at high concentration ratios is proved by comparison with a numerical solution of the homogenization problem. To this end some theoretical result of symmetry properties of the homogenization problem are given. Using these results efficient numerical computation on a reduced computational domain is presented.

Radon Concentration in Various Indoor Environment and Effective Dose by Inhabitants in Korea (국내 다양한 실내환경에서 라돈농도 및 거주자의 실효선량 평가)

  • Lee, Cheol-Min;Kim, Yoon-Shin;Roh, Young-Man;Kim, Ki-Youn;Jeon, Hyung-Jin;Kim, Jong-Cheol
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.4
    • /
    • pp.264-275
    • /
    • 2007
  • The objective of this study was to offer basic and scientific data for decision-making of policy for improvement and management of radon, natural radiation gas, in Korea and to form the foundation of radon related international cooperation. Therefore, this study collected and re-analysed the articles on exposure of radon in various indoor environment in journals related environment in Korea since 1980 and estimated the annual exposure dose and effective dose by exposure of radon received by inhabitants in them. The highest pooled average radon concentration of $50.17{\pm}4.08\;Bq/m^3$ (95% CI : $42.17{\sim}58.17\;Bq/m^3$) was found in dwelling house among various indoor environment. All of pooled average radon concentration estimated in this study showed lower than the guideline concentration ($148\;Bq/m^3)$ of US EPA and the Korean Ministry of Environment. The annual effective dose received by inhabitants in various indoor environment was estimated 1.071 mSv/yr. That is equal to annual effective dose (1.0 mSv/yr) by exposure of radon estimated by UNSCEAR.