• Title/Summary/Keyword: Effect-site Concentrations

Search Result 165, Processing Time 0.026 seconds

Vegetation and Soil Properties of the Coastal Sand Dune in Sinduri, Taean Gun (태안군 신두리 해안사구의 식생과 토양특성)

  • Song, Hokyung;Park, Gwansoo;Park, Hyerim;Seo, Eunkyoung;So, Soonku;Kim, Muyeol
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.8 no.6
    • /
    • pp.59-68
    • /
    • 2005
  • This study was carried out to investigate soil properties, ordination, and vegetation of the coastal sand dune in Sinduri, Taean-Gun. 1. The Orobanche coerulescens and Ixeris repens that are a peculiar species were found in Sinduri coastal sand dune and the Salix purpurea var. japonica that is an endemic species of korea was found in that place. The plant communities was categorized into seven groups, such as Rosa rugosa community, Vitex rotundifolia communit, Carex kobomugi community, Imperata cylndrica var. koenigii community, Carex pumila community, Artemisia capillaris community, and Calamagrostis epigeios community. 2. The soil organic matter, total nitrogen, available phosphorous concentrations, and cation exchange capacity were lower in the study sites than in forest soil of seashore. There was little difference in soil exchangeable Ca, Mg, and K concentrations between in the study site and in the forest soil of seashore. The soil pH was ranged from 5.69 to 7.63. The soil texture in the study site was sand or loamy sand. 3. The results of the correlation between Sinduri coastal sand dune community and environmental factor are as follows; the soil pH was the most effect to the community distribution, and CEC, total nitrogen, soil organic matter, and the amount of silt in soil have some correlation with community distribution. 4. The results of the correlation between Sinduri coastal sand dune community and soil characteristics are as follows; the Calamagrostis epigeios community was found in area that have high soil moisture content; the Rosa rugosa community was found in area that have high soil CEC, organic matter concentration, and total nitrogen concentration, and low soil pH; the Vitex rotundifolia community, Carex kobomugi community, and Artemisia capillaris community were found in area that have low soil CEC, organic matter concentration, and total nitrogen concentration, and high soil pH; the Imperata cylndrica var. koenigii community and Carex pumila community were found in area that have medium soil CEC, organic matter concentration, total nitrogen concentration, and soil pH.

Concentrations of Criteria Pollutants in Indoor and Ambient Air of Public Facilities in Taegu Area (대구지역 공중이용시설의 실내 $\cdot$ 외 공기 중 기준성오염물질의 농도)

  • 송희봉;민경섭;한개희;김종우;백성옥
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.4
    • /
    • pp.429-439
    • /
    • 1996
  • A comprehensive air quality monitoring was carried out in this study to investigate the concentrations of criteria air pollutants in indoor and outdoor air of public facilities in Taegu area. Four different kinds of public facilities were seleced as sampling sites, which are underground stores, stations & terminals, general hospitals, and department stores. Each group of the public facilities was consisted of three different sampling sites. As a consequence, a total of 12 different sampling sites were surveyed throughout this study. Sampling was conducted simultaneously indoors, three times per day (in the morning, afternoon, and evening) and four times per year (spring, summer, fall, and winter) at each sampling site during the period of October 1994 to July 1995. A range of criteria pollutants were measured in order to obtain a broad profile of indoor and ambient air quality, including total suspended particles (TSP), carbon monoxide (CO), carbon dioxide ($CO_2$), formaldehyde (HCHO), sulfur dioxide ($SO_2$), and nitrogen dioxide ($NO_2$). In addition, temperature, relative humidity, and air current were measured on site together with those air pollutants. Results of this study indicated that the indoor levels of TSP, CO, $SO_2, and NO_2$ appeared to be generally higher in stations/terminals and underground stores than those in department stores and hospitals. However, HCHO and $CO_2$ were found to have higher levels in the department stores and hospitals than other places, indicating that the effects of indoor sources for these pollutants are significantly different from other combustion related pollutants such as TSP, CO, and $SO_2$. It was also found that there are marked seasonal and daily variations both in indoor and outdoor air quality. In general, combustion related pollutants such as CO, $SO_2$ and $NO_2$ showed a typical pattern of higher levels in winter than insummer, and also higher in the morning and/or in the evening than in the afternoon. However, the seasonal and daily patterns of HCHO appeared to be opposite to the combustion related pollutants, i.e., higher both in summer and in the afternoon, implying the effect of temperature on the volatilization from indoor sources of HCHO. Results of correlation analyses between indoor and outdoor air quality also indicated that the effects of outdoor sources on the indoor levels of TSP, $SO_2$, CO, and $NO_2$ and much significant, whilst no significant correlations between indoor and outdoor levels were found for HCHO and $CO_2$.

  • PDF

Chemical Composition and Features of Asian Dust Observed in Korea (2000~2002) (2000~2002년 우리나라에서 관측된 황사의 화학 조성 및 특성)

  • Shin S.A;Han J.S;Hong Y.D;Ahn J.Y;Moon K.J;Lee S.J;Kim S.D
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.1
    • /
    • pp.119-129
    • /
    • 2005
  • The ambient TSP data measured at Seoul, Incheon. Taean, Daegu, Busan in Korea were used to explain the chemical composition and general features of Asian Dust (AD) observed in Korea. 9 episodes out of 19 were sampled from 2000 through May 2002, and measurements were conducted covering ionic and metal components with mass concentration. The results showed that daily averaged mass concentration (TSP) during the AD episodes was 458 $\mu\textrm{g}$/㎥, and ionic and metal concentrations were 27.93 $\mu\textrm{g}$/㎥ and 71.7 $\mu\textrm{g}$/㎥, respectively, accounting for 6.1 % and 15.5% of the total aerosol mass. TSP concentrations during episodes were varied from 120 to 1742 $\mu\textrm{g}$/㎥ according to the impact of Asian Dusts and had a tendency of showing higher values at sites in the west side of Korea, which can be explained by the effect of diffusion and deposition. In this study, ionic components like Ca (NO$_3$)$_2$, CaSO$_4$, NaNO$_3$, Na$_2$SO$_4$ were prominent types in secondary aerosol during AD periods and also indicated that V, Co as well as soil elements such as Ca, Fe, Mg, Mn, K correlated well with Al, while Cu, Cd, Pb, Zn didn't agree well with it. In addition, enrichment factors (EFs) for each metal component were obtained to provide simple information about source contribution of Asian Dust, and the results were compared with those from other AD studies. In this study, the results showed that aerosol properties in Korea during the Asian Dust were considerably different from those of general atmospheric condition and specially varied from case to case rather than site to site, which implies that there are certain variations in the soil of source region, pathways of air mass, and meteorological condition. For the enhanced study, those factors should be combined with the features of Asian Dust resolved from this study.

The Effect of Platform Screen Doors on PM10 Levels in a Subway Station and a Trial to Reduce PM10 in Tunnels

  • Son, Youn-Suk;Salama, Amgad;Jeong, Hye-Seon;Kim, Suhyang;Jeong, Jin-Ho;Lee, Jaihyo;SunWoo, Young;Kim, Jo-Chun
    • Asian Journal of Atmospheric Environment
    • /
    • v.7 no.1
    • /
    • pp.38-47
    • /
    • 2013
  • $PM_{10}$ concentrations were measured at four monitoring sites at the Daechaung station of the Seoul subway. The four locations included two tunnels, a platform, and a waiting room. The outside site of the subway was also monitored for comparison purposes. In addition, the effect of the platform screen doors (PSDs) recently installed to isolate the $PM_{10}$ in a platform from a tunnel were evaluated, and a comparison between $PM_{10}$ levels during rush and non-rush hours was performed. It was observed that $PM_{10}$ levels in the tunnels were generally higher than those in the other locations. This might be associated with the generation of $PM_{10}$ within the tunnel due to the train braking and wear of the subway lines with the motion of the trains, which promotes the mixing and suspension of particulate matter. During this tunnel study, it was observed that the particle size of $PM_{10}$ ranged from 1.8 to 5.6 ${\mu}m$. It was revealed that the $PM_{10}$ levels in the tunnels were significantly increased by the PSDs, while those in the platform and waiting room decreased. As a result, in order to estimate the effect of ventilation system on $PM_{10}$ levels in the tunnels, fans with inverters were operated. It was found that the concentration of $PM_{10}$ was below 150 ${\mu}g/m^3$ when the air flow rate into a tunnel was approximately 210,000-216,000 CMH.

Effect of organic concentration on its degradation kinetics in a burial site (매몰지 내 유기물 농도가 분해 속도에 미치는 영향)

  • Lee, Chae-Young;Choi, Jae-Min;Oh, Seung-Jun;Han, Sun-Kee;Park, Joon-Kyu
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.21 no.1
    • /
    • pp.62-68
    • /
    • 2013
  • The effect of organic substance on its degradation rate in burial site was investigated using batch tests. Substrate were swine and cattle with the initial concentrations of 2, 4, 6, 8, and 10 g VS(volatile solids)/L, respectively. The highest methane production rates of swine and cattle were found at 2 g VS/L as 46.3 and 48.4 ml CH4/g VS.d, respectively. As substrate concentration increased, the methane production rate decreased. The inhibition constants were n and m that were estimated using nonlinear inhibition model. The values of n and m were inhibition constants of methane production rate and ultimate methane yield, respectively. The values of n and m were 4.9 and 0.6 on swine and 1.1 and 0.4 on cattle. The methane production rate was responded sensitively by increase and decrease of substrate concentration, whereas ultimate methane yield do not relatively. From a relation between n and m, inhibitory effect of substrate concentration was confirmed as uncompetitive inhibition.

Exposure Assessments of Environmental Contaminants in Ansim Briquette Fuel Complex, Daegu(II) - Concentration distribution and exposure characteristics of TSP, PM10, PM2.5, and heavy metals - (대구 안심연료단지 환경오염물질 노출 평가(II) - TSP, PM10, PM2.5 및 중금속 농도분포 및 노출특성 -)

  • Jung, Jong-Hyeon;Phee, Young-Gyu;Lee, Jun-Jung;Oh, In-Bo;Shon, Byung-Hyun;Lee, Hyung-Don;Yoon, Mi-Ra;Kim, Geun-Bae;Yu, Seung-do;Min, Young-Sun;Lee, Kwan;Lim, Hyun-Sul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.380-391
    • /
    • 2015
  • Objectives: The objective of this study is to assess airborne particulate matter pollution and its effect on health of residents living near Ansim Briquette Fuel Complex and its vicinities. Also, this study measured and analyzed the concentration of TSP, $PM_{10}$, $PM_{2.5}$, and heavy metals which influences on the environmental and respiratory disease in Ansim Briquette Fuel Complex, Daegu, Korea. Methods: In this study, we analyzed various environmental pollutants such as particulate matter and heavy metals from Ansim Briquette Fuel Complex that adversely affected local residents's health. In particular, we verified the concentration distribution and characteristics of exposure for TSP, $PM_{10}$, and $PM_{2.5}$ among particulate matters, and heavy metals(Cd, Cr, Cu, Mn, Ni, Pb, Fe, Zn, and Mg). In that regard, the official test method on air pollution in Korea for analysis of particulate matter and heavy metal in atmosphere were conducted. The large capacity air sampling method by the official test method on air pollution in Korea were applied for sampling of heavy metals in atmosphere. In addition, we evaluated the concentration of seasonal environmental pollutants for each point of residence in Ansim Briquette Fuel Complex and surrounding area. The sampling measured periods for air pollutants were from August 11, 2013 to February 21, 2014. Furthermore, we measured and analyzed the seasonal concentrations(summer, autumn and winter). Results: The average concentration for TSP, $PM_{10}$, and $PM_{2.5}$ by direct influence area at Ansim Briquette Fuel Complex were 1.7, 1.4 and 1.9 times higher than reference region. In analysis results of seasonal concentrations for particulate matter in four direct influence and reference area, concentration levels for winter were generally somewhat higher than concentrations for summer and autumn. The average concentrations for Cd, Cr, Mn, Ni, Pb, Fe, and Zn in direct influence area at Ansim Briquette Fuel Complex were $0.0008{\pm}0.0004{\mu}g/Sm^3$, $0.0141{\pm}0.0163{\mu}g/Sm^3$, $0.0248{\pm}0.0059{\mu}g/Sm^3$, $0.0026{\pm}0.0011{\mu}g/Sm^3$, $0.0272{\pm}0.0084{\mu}g/Sm^3$, $0.4855{\pm}0.1862{\mu}g/Sm^3$, and $0.3068{\pm}0.0631{\mu}g/Sm^3$, respectively. In particularly, the average concentrations for Cd, Cr, Mn, Ni, Pb, Fe, and Zn in direct influence area at Ansim Briquette Fuel Complex were 1.9, 3.6, 2.1, 1.9, 1.4, 2.6, and 1.2 times higher than reference area, respectively. The continuous monitoring and management were required for some heavy metals such as Cr and Ni. Moreover, the average concentration in winter for particulate matter in direct influence area at Ansim Briquette Fuel Complex were generally higher than concentrations in summer and autumn. Also, average concentrations for TSP, $PM_{10}$, and $PM_{2.5}$ were from 1.5 to 2.0 times, 1.2 to 1.8 times, and 1.1 to 2.3 times higher than reference area, respectively. In results for seasonal atmospheric environment, TSP, $PM_{10}$, $PM_{2.5}$, and heavy metal concentrations in direct influence area were higher than reference area. Especially, the concentrations in C station were a high level in comparison with other area. Conclusions: In the results, some particulate matters and heavy metals were relatively high concentration, in order to understand the environmental pollution level and health effect in surrounding area at Ansim Briquette Fuel Complex. The concentration of some heavy metals emitted from direct influence area at Ansim Briquette Fuel Complex were relatively higher than reference area. In particular, average concentration for heavy metals in this study were higher than average concentrations in air quality monitoring station for heavy metal for 7 years in Deagu metropolitan region. Especially, the residents near Ansim Briquette Fuel Complex may be exposed to the pollutants(TSP, $PM_{10}$, $PM_{2.5}$, and heavy metals, etc) emitted from the factories in Ansim Briquette Fuel Complex.

Variations of Ozone and PM10 Concentrations and Meteorological Conditions according to Airflow Patterns of their High Concentration Episodes on Jeju Island (제주지역 오존 및 미세먼지 고농도일의 기류패턴에 따른 농도변화와 기상조건 분석)

  • Han, Seung-Bum;Song, Sang-Keun;Choi, Yu-Na
    • Journal of Environmental Science International
    • /
    • v.26 no.2
    • /
    • pp.183-200
    • /
    • 2017
  • The classification of airflow patterns during high ozone ($O_3$) and $PM_{10}$ episodes on Jeju Island in recent years (2009-2015), as well as their correlation with meteorological conditions according to classified airflow patterns were investigated in this study. The airflow patterns for $O_3$ and $PM_{10}$ were classified into four types (Types A-D) and three types (Types E-G), respectively, using the HYbrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model and synoptic weather charts. Type A was the most dominant airflow pattern for $O_3$ episodes, being characterized by the transport of airflows from urban and industrial areas in China with the highest frequency (about 69%, with a mean of 67 ppb). With regard to the $PM_{10}$ episodes, Type E was the most dominant airflow pattern, and was mostly associated with long distance transport from Asian dust source regions along northwesterly winds, having the highest frequency (about 92%, with a mean of $136{\mu}g/m^3$). The variations in the concentration of $O_3$ and $PM_{10}$ during the study period were clarified in correlation with two pollutant and meteorological variables; for example, the high (low) $O_3$ and $PM_{10}$ concentrations with high (low) air temperature and/or wind speed and vice versa for precipitation. The contribution of long-range transport to the observed $PM_{10}$ levels in urban sites for different airflow patterns (Types E-F), if estimated in comparison to the data from the Gosan background site, was found to account for approximately 87-93% (on average) of its input. The overall results of the present study suggest that the variations in $O_3$ and $PM_{10}$ concentrations on Jeju Island are mainly influenced by the transport effect, as well as the contribution of local emissions.

Evaluation of Methane Oxidation Potentials of Alpine Soils Having Different Forestation Structure in Gajwa mountain (경상남도 가좌산의 소나무, 참나무, 밤나무 우점 산림토양 별 메탄 산화능 평가)

  • Park, Yong Kwon;Kim, Sang Yoon;Gwon, Hyo Suk;Kim, Pil Joo
    • Korean Journal of Environmental Agriculture
    • /
    • v.33 no.4
    • /
    • pp.306-313
    • /
    • 2014
  • BACKGROUND: Forest soils contain microbes capable of consuming atmospheric methane ($CH_4$), an amount matching the annual increase in $CH_4$ concentration in the atmosphere. However, the effect of plant residue production by different forest structure on $CH_4$ oxidation is not studied in Korea. The objective of this study was to evaluate the effect of Korean alpine soils having different forestation structure on $CH_4$ uptake rates. METHODS AND RESULTS: the $CH_4$ flux was measured at three sites dominated with pine, chestnut and oak trees in southern Korea. The $CH_4$ uptake potentials were evaluated by a closed chamber method for a year. The $CH_4$ uptake rate was the highest in the pine tree soil ($1.05mg/m^2/day$) and then followed by oak ($0.930mg/m^2/day$) and chestnut trees ($0.497mg/m^2/day$). The $CH_4$ uptake rates were highly correlated to soil organic matter and moisture contents, and total microbial and methanotrophs activities. Different with the general concent, there was no any correlation between $CH_4$ oxidation rates, and soil temperature and labile carbon concentrations, irrespective with tree species. CONCLUSION: Conclusively, the methane oxidation rate was correlated in positive manner with organic matter, abundance of methanotrophs. Methane oxidation was different among tree species. This results could be used to estimate methane oxidation rate in forest of Korea after complementing information about statistical data and methane oxidation of other site.

A Comparative Analysis of Negative Air Ions according to the Planting Structure at School Forests (학교 숲 식재구조에 따른 음이온 발생량 비교 분석)

  • Kim, Jeong-Ho;Oh, Deuk-Kyun;Park, Yong-Gwan;Yoon, Yong-Han
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.5
    • /
    • pp.55-64
    • /
    • 2015
  • In this study, negative air ions, which can increase comfort and positively influence human health, was set as an evaluative factor for school forests. The characteristics, location and microclimate of school forests were examined to determine an effective school forest model for maximum negative air ion generation. It also aimed to provide basic data for the development of urban green fields. The negative air ion concentrations were different according to the green types. The order from the highest to the lowest was: single-layer structure($934ea/cm^3$) > multi-layer structure($794ea/cm^3$) > grass($553ea/cm^3$) > bare ground($529ea/cm^3$). As for the correlation with microclimate, negative air ion concentration was negatively correlated with temperature. The negative air ion concentration was significantly different according to planting type. The negative air ion concentration was higher at single-layer structure sites than at multi-layer structure sites, which appears to indicate that the temperature is higher when the vegetation structure was single-layer compared to multi-layer. Wind speed was higher at the single-layer planted site than at the multi-layer planted site. The vegetation wind shielding effect was lower at single-layer planted sites than at multi-layer planted sites. The single-layer planted site provided more favorable conditions for the generation and dispersion of negative air ions.

Safety and efficacy of target controlled infusion administration of propofol and remifentanil for moderate sedation in non-hospital dental practice

  • Douglas Lobb;Masoud MiriMoghaddam;Don Macalister;David Chrisp;Graham Shaw;Hollis Lai
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.23 no.1
    • /
    • pp.19-28
    • /
    • 2023
  • Background: Fearful and anxious patients who find dental treatment intolerable without sedative and analgesic support may benefit from moderate sedation. Target controlled infusion (TCI) pumps are superior to bolus injection in maintaining low plasma and effect-site concentration variability, resulting in stable, steady-state drug concentrations. We evaluated the safety and efficacy of moderate sedation with remifentanil and propofol using TCI pumps in non-hospital dental settings. Methods: A prospective chart review was conducted on 101 patients sedated with propofol and remifentanil using TCI pumps. The charts were completed at two oral surgeons and one general dentist's office over 6 months. Hypoxia, hypotension, bradycardia, and over-sedation were considered adverse events and were collected using Tracking and Reporting Outcomes of Procedural Sedation (TROOPS). Furthermore, patient recovery time, sedation length, drug dose, and patient satisfaction questionnaires were used to measure sedation effectiveness. Results: Of the 101 reviewed sedation charts, 54 were of men, and 47 were of women. The mean age of the patients was 40.5 ±18.7 years, and their mean BMI was 25.6 ± 4.4. The patients did not experience hypoxia, bradycardia, and hypotension during the 4694 min of sedation. The average minimum Mean Arterial Pressure (MAP) and heartbeats were 75.1 mmHg and 60.4 bpm, respectively. 98% of patients agreed that the sedation technique met their needs in reducing their anxiety, and 99% agreed that they were satisfied with the sedation 24 hours later. The average sedation time was 46.9 ± 55.6 min, and the average recovery time was 12.4 ± 4.4 min. Remifentanil and propofol had mean initial effect-site concentration doses of 0.96 µ/.ml and 1.0 ng/ml respectively. The overall total amount of drug administered was significantly higher in longer sedation procedures compared to shorter ones, while the infusion rate decreased as the procedural stimulus decreased. Conclusion: According to the results of this study, no patients experienced adverse events during sedation, and all patients were kept at a moderate sedation level for a wide range of sedation times and differing procedures. The results showed that TCI pumps are safe and effective for administering propofol and remifentanil for moderate sedation in dentistry.