• Title/Summary/Keyword: Effect-evaluation

Search Result 11,208, Processing Time 0.052 seconds

Studies on the Functional Interrelation between the Vestibular Canals and the Extraocular Muscles (미로반규관(迷路半規管)과 외안근(外眼筋)의 기능적(機能的) 관계(關係)에 관(關)한 연구(硏究))

  • Kim, Jeh-Hyub
    • The Korean Journal of Physiology
    • /
    • v.8 no.2
    • /
    • pp.1-17
    • /
    • 1974
  • This experiment was designed to explore the specific functional interrelations between the vestibular semicircular canals and the extraocular muscles which may disclose the neural organization, connecting the vestibular canals and each ocular motor nuclei in the brain system, for vestibuloocular reflex mechanism. In urethane anesthetized rabbits, a fine wire insulated except the cut cross section of its tip was inserted into the canals closely to the ampullary receptor organs through the minute holes provided on the osseous canal wall for monopolar stimulation of each canal nerve. All extraocular muscles of both eyes were ligated and cut at their insertio, and the isometric tension and EMG responses of the extraocular muscles to the vestibular canal nerve stimulation were recorded by means of a physiographic recorder. Upon stimulation of the semicircular canal nerve, direction if the eye movement was also observed. The experimental results were as follows. 1) Single canal nerve stimulation with high frequency square waves (240 cps, 0. 1 msec) caused excitation of three extraocular muscles and inhibition of remaining three muscles in the bilateral eyes; stimulation of any canal nerve of a unilateral labyrinth caused excitation (contraction) of the superior rectus, superior oblique and medial rectus muscles and inhibition (relaxation) of the inferior rectus, inferior oblique and lateral rectos muscles in the ipsilateral eye, and it caused the opposite events in the contralateral eye. 2) By the overlapped stimulation of triple canal nerves of a unilateral labyrinth, unidirectional (excitatory or inhibitory) summation of the individual canal effects on a given extraocular muscles was demonstrated, and this indicates that three different canals of a unilateral vestibular system exert similar effect on a given extraocular muscles. 3) Based on the above experimental evidences, a simple rule by which one can define the vestibular excitatory and inhibitory input sources to all the extraocular muscles is proposed; the superior rectus, superior oblique and medial rectus muscles receive excitatory impulses from the ipsilateral vestibular canals, and the inferior rectus, inferior oblique and lateral rectus muscles from the contralateral canals; the opposite relationship applies for vestibular inhibitory impulses to the extraocular muscles. 4) According to the specific direction of the eye movements induced by the individual canal nerve stimulation, an extraocutar muscle exerting major role (a muscle of primary contraction) and two muscles of synergistic contraction could be differentiated in both eyes. 5) When these experimental results were compared to the well known observations of Cohen et al. (1964) made in the cats, extraocular muscles of primary contraction were the same but those of synergistic contraction were partially different. Moreover, the oblique muscle responses to each canal nerve excitation appeared to be all identical. However, the responnes of horizontal (medial and lateral) and vertical (superior and inferior) rectus muscles showed considerable differences. By critical analysis of these data, the author was able to locate theoretical contradictions in the observations of Cohen et al. but not in the author's results. 6) An attempt was also made to compare the functional observation of this experiment to the morphological findings of Carpenter and his associates obtained by degeneration experiments in the monkeys, and it was able to find some significant coincidence between there two works of different approach. In summary, the author has demonstrated that the well known observations of Cohen et al. on the vestibulo-ocular interrelation contain important experimental errors which can he proved by theoretical evaluation and substantiated by a series of experiments. Based on such experimental evidences, a new rule is proposed to define the interrelation between the vestibular canals and the extraocular muscles.

  • PDF

The Long-term Follow-up Study of Therapeutic Effects of 8 French Catheter for Spontaneous Pneumothorax (자연 기흉의 치료에서 8 French 도관삽입의 치료 효과에 대한 장기적 관찰)

  • Shin, Jong-Wook;Lee, Byoung-Hoon;An, Chang-Hyeok;Choi, Jae-Sun;Yoo, Jee-Hoon;Lim, Seong-Yong;Kang, Yoon-Jung;Koh, Hyung-Ki;Kim, Jae-Yeol;Na, Moon-Jun;Park, In-Won;Sobn, Dong-Suep;Choi, Byoung-Whui;Hue, Sung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.1094-1104
    • /
    • 1997
  • Background : Spontaneous pneumothoraces(SP) are divided into primary spontaneous pneumothoraces (PSP) which develop in healthy individuals without underlying pulmonary disorders and secondary spontaneous pneumothoraces(SSP) which occur in those who have underlying disorders such as tuberculosis or chronic obstructive lung diseases. Yet there is no established standard therapeutic approach to this disorder, i.e., from the spectrum of noninvasive treatment such as clinical observation with or without oxygen therapy, to aggressively invasive thoracoscopic bullectomy or open thoracotomy. Although chest tube thoracostomy has been most widely used, the patients should overcome pain in the initiation of tube insertion or during indwelling it potential infection and subcutaneous emphysema. Thus smaller-caliber tube has been challenged for the treatment of pneumothorax. Previously, we studied the therapeutic efficacy of 8 French catheter for spontaneous pneumothorax. But there has been few data for effectiveness of small-caliber catheterization in comparison with that of chest tube. In this study, we intended to observe the long-term effectiveness of 8 French catheter for the treatment of spontaneous pneumothoraces in comparison with that of chest tube thoracostomy. Method : From January, 1990 to January, 1996, sixty two patients with spontaneous pneumothoraces treated at Chung-Ang University Hospital were reviewed retrospectively. The patients were sub-divided into a group treated with 8 French catheter(n=23) and the other one with chest tube insertion(n=39). The clinical data were reviewed(age, sex, underlying pulmonary disorders, past history of pneumothorax, size of pneumothorax, follow-up period). And therapeutic effect of two groups was compared by treatment duration(duration of indwelling catheter or tube), treatment-associated complications and recurrence rate. Results : The follow-up period(median) of 8 French catheter group and chest tube group was 28 and 22 months, which had no statistical significance. Ther was no statistically significant difference of clinical characteristics between two groups with SP, PSP, SSP. The indwelling time of 8 French catheter group was $6.2{\pm}3.8$ days, which was significantly shorter than that of chest tube group in SP, $9.1{\pm}7.5$ days(p=0.047). In comparison of treatment-related complication in PSP, 8 French catheter group as 6.25% of complication showed lower tendency than the other group as 23.8% (p=0.041 ; one-tailed, p=0.053; two-tailed). The recurrence rate in each group of SP was 17.4%, 10.3%, which did not show any statistically significant difference. Conclusion : Treatment with 8 French catheter resulted in shorter indwelling time in sponteous pneumothorax, and lower incidence of treatment-related complication in primary spontaneous pneumothorax. And the recurrence rate in each of treatment group showed no statistically significant difference. So, we can recommend the 8 French small-caliber catheter for the initial therapy for spontaneous pneumothorax for the replacement of conventional chest tube thoracostomy. But further prospective study with more subjects of spontaneous pneumothorax will be needed for the evaluation of effectiveness of 8 French cateter.

  • PDF

The Effect of Korean Soysauce and Soypaste Making on Soybean Protein Quality Part II. Chemical Changes During Meju-brine Ripening (재래식 간장 및 된장 제조가 대두 단백질의 영양가에 미치는 영향 제2보 메주장의 숙성중에 일어나는 성분 변화)

  • Lee, Cherl-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.19-32
    • /
    • 1976
  • The laboratory Mejus as well as home-made Meju and improved Meju received from Korea were ripened in the brine for up to 8 months and the changes is the chemical composition during the process were determined and the differences between the types of Meju were compared. On the basis of the amino acid pattern, the changes in the protein quality of soybean during the process was evaluated. No significant changes in the general chemical composition of Meju were noticed during the ripening for 8 months. However, the nitrogen solubility of Meju increased for $13{\sim}29%$ to $66{\sim}78%$ during 8 month ripening of the Meju-brine mixture. The concentration of free amino-N to the total-N increased from $4{\sim}7%$ in Meju to $29{\sim}35%$ in the 8month ripened mixture. The concentration of amino-N to the total-N increased from $1{\sim}4%$ in Meju to $5{\sim}14%$ in the 8month ripened mixture and the changes varied with the type of Meju used. Remarkable changes in the amino acid pattern of soybean were occured during the ripening process. The concentration of methionine decreased to the half of original Meju during the first month of ripening. Arginine and histidine were destroyed rapidly by the ripening longer than 1 month. A considerable amount of ornithine was synthesized during the ripening. The amino acid pattern of Meju did change drastically during the ripening longer than 3 months and the changes varied with the type of Meju. The retention of the nutrients in soybean during 8 month ripening of the laboratory 3 month Meju in the brine was 49% for carbohydrates, 107% for crude fat, 93% for crude protein and 74% for the total amino acid. Histidine, arginine and methionine and 74% for the total amino acid. Histidine, arginine and methionine were the most damaged during the process, retaining only 25%, 27% and 49% of the contents in raw soybean, respectively, whereas lysine retained 79%. By the separation of the 8 month ripened mixture, approximately 60% of crude protein, all of crude fat and 80% of carbohydrates in the mixture were retained in soypaste. Soypaste contained higher concentrations of amino acids per 16gN compared to soysauce, except for lysine. The most limiting amino acid of the protein was the S-containing amino acids in all cases studied, whereas the second limiting amino acid varied from valine in soybean to threonine in most of Mejus and the brine mixtures, lysine in most of soypastes and tryptophan in some of soysauces. According to the protein quality evaluation made by the reference of the FAO provisional pattern of amino acid, the chemical score of raw soybean was 82, which was reduced to 77 by cooking and further reduced to $71{\sim}74$ by Meju fermentation. At the eighth month of ripening the chemical score of the Meju-brine mixtures were reduced to $51{\sim}66. After the separation, the chemical score of soypaste ranged from 60 to 71, whereas that of soysauce varied from 45 to 57. Generally, the products made from improved Meju recorded the highest score, whereas those made from homemade Meju showed the poorest protein quality. The essential amino acid index(EAAI) of the samples was similar to the chemical score, but it appeared to fit the overall changes in the amino acid pattern during the process better than the chemical score.

  • PDF

The Comparison of Image Quality and Quantitative Indices by Wide Beam Reconstruction Method and Filtered Back Projection Method in Tl-201 Myocardial Perfusion SPECT (Tl-201 심근관류 SPECT 검사에서 광대역 재구성(Wide Beam Reconstruction: WBR) 방법과 여과 후 역투영법에 따른 영상의 질 및 정량적 지표 값 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Shim, Dong-Oh;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.122-127
    • /
    • 2010
  • Purpose: The Xpress3.$cardiac^{TM}$ which is a kind of wide beam reconstruction (WBR) method developed by UltraSPECT (Haifa, Israel) enables the acquisition of at quarter time while maintaining image quality. The purpose of this study is to investigate the usefulness of WBR method for decreasing scan times and to compare to it with filtered back projection (FBP), which is the method routinely used. Materials and Methods: Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on an equality with counts from patient's body. The Tl-201 concentrations in the compartments were 74 kBq (2 ${\mu}Ci$)/cc in myocardium, 11.1 kBq (0.3 ${\mu}Ci$)/cc in soft tissue, and 2.59 kBq (0.07 ${\mu}Ci$)/cc in lung. The non-gated Tl-201 myocardial perfusion SPECT data were acquired with the phantom. The former study was scanned for 50 seconds per frame with FBP method, and the latter study was acquired for 13 seconds per frame with WBR method. Using the Xeleris ver. 2.0551, full width at half maximum (FWHM) and average image contrast were compared. In clinical studies, we analyzed the 30 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center from January to April 2010. The patients were imaged at full time (50 second per frame) with FBP algorithm and again quarter-time (13 second per frame) with the WBR algorithm. Using the 4D MSPECT (4DM), Quantitative Perfusion SPECT (QPS), and Quantitative Gated SPECT (QGS) software, the summed stress score (SSS), summed rest score (SRS), summed difference score, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were analyzed for their correlations and statistical comparison by paired t-test. Results: As a result of the phantom study, the WBR method improved FWHM more than about 30% compared with FBP method (WBR data 5.47 mm, FBP data 7.07 mm). And the WBR method's average image contrast was also higher than FBP method's. However, in result of quantitative indices, SSS, SDS, SRS, EDV, ESV, EF, there were statistically significant differences from WBR and FBP(p<0.01). In the correlation of SSS, SDS, SRS, there were significant differences for WBR and FBP (0.18, 0.34, 0.08). But EDV, ESV, EF showed good correlation with WBR and FBP (0.88, 0.89, 0.71). Conclusion: From phantom study results, we confirmed that the WBR method reduces an acquisition time while improving an image quality compared with FBP method. However, we should consider significant differences in quantitative indices. And it needs to take an evaluation test to apply clinical study to find a cause of differences out between phantom and clinical results.

  • PDF

Evaluation of Artifacts by Dental Metal Prostheses and Implants on PET/CT Images: Phantom and Clinical Studies (PET/CT 영상에서의 치과재료에 의한 인공물에 관한 연구)

  • Bahn, Young-Kag;Park, Hoon-Hee;NamKoong, Hyuk;Cho, Suk-Won;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.110-116
    • /
    • 2010
  • Purpose: The X-ray attenuation coefficient based on CT images is used for attenuation correction in PET/CT. The polychromatic X-ray beam can introduce beam-hardening artifact on CT images. The aims of the study were to evaluate the effect of dental metal prostheses in phantom and patients on apparent tracer activity measured with PET/CT when using CT attenuation correction. Materials and Methods: 40 normal patients (mean age $54{\pm}12$) was scanned between Jan and Feb 2010. NEMA(National Electrical Manufactures Association) PET $Phantom^{TM}$ (NU2-1994) was filled with $^{18}F$-FDG injected into the water that insert implant and metal prostheses dental cast. Region of interest were drawn in non-artifact region, bright steak artifact region and dark streak artifact region on the same transaxial CT and PET slices. Patients and phantom with dental metal prostheses and dental implant were evaluated the change rate of CT Number and $SUV_{mean}$ in PET/CT. A paired t-test was performed to compare the ratio and the difference of the calculated values. Results: In patients with dental metal prostheses, $SUV_{mean}$ was reduced 19.64% (p<0.05) in the non-steak artifact region than the brightstreak artifact region whereas was increased 90.1% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental metal prostheses, $SUV_{mean}$ was reduced 18.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 18.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In patients with dental implant, $SUV_{mean}$ was increased 19.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 96.62% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental implant, $SUV_{mean}$ was increased 14.4% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 7.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. Conclusion: When CT is used for attenuation correction in patients with dental metal prostheses, 19.1% reduced $SUV_{mean}$ is anticipated in the dark streak artifact region on CT images. The dark streak artifacts of CT by dental metal prostheses may cause false negative finding in PET/CT. We recommend that the non-attenuation corrected PET images also be evaluated for clinical use.

  • PDF

A study on evaluation of the image with washed-out artifact after applying scatter limitation correction algorithm in PET/CT exam (PET/CT 검사에서 냉소 인공물 발생 시 산란 제한 보정 알고리즘 적용에 따른 영상 평가)

  • Ko, Hyun-Soo;Ryu, Jae-kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.55-66
    • /
    • 2018
  • Purpose In PET/CT exam, washed-out artifact could occur due to severe motion of the patient and high specific activity, it results in lowering not only qualitative reading but also quantitative analysis. Scatter limitation correction by GE is an algorism to correct washed-out artifact and recover the images in PET scan. The purpose of this study is to measure the threshold of specific activity which can recovers to original uptake values on the image shown with washed-out artifact from phantom experiment and to compare the quantitative analysis of the clinical patient's data before and after correction. Materials and Methods PET and CT images were acquired in having no misalignment(D0) and in 1, 2, 3, 4 cm distance of misalignment(D1, D2, D3, D4) respectively, with 20 steps of each specific activity from 20 to 20,000 kBq/ml on $^{68}Ge$ cylinder phantom. Also, we measured the distance of misalignment of foley catheter line between CT and PET images, the specific activity which makes washed-out artifact, $SUV_{mean}$ of muscle in artifact slice and $SUV_{max}$ of lesion in artifact slice and $SUV_{max}$ of the other lesion out of artifact slice before and after correction respectively from 34 patients who underwent $^{18}F-FDG$ Fusion Whole Body PET/CT exam. SPSS 21 was used to analyze the difference in the SUV between before and after scatter limitation correction by paired t-test. Results In phantom experiment, $SUV_{mean}$ of $^{68}Ge$ cylinder decreased as specific activity of $^{18}F$ increased. $SUV_{mean}$ more and more decreased as the distance of misalignment between CT and PET more increased. On the other hand, the effect of correction increased as the distance more increased. From phantom experiments, there was no washed-out artifact below 50 kBq/ml and $SUV_{mean}$ was same from origin. On D0 and D1, $SUV_{mean}$ recovered to origin(0.95) below 120 kBq/ml when applying scatter limitation correction. On D2 and D3, $SUV_{mean}$ recovered to origin below 100 kBq/ml. On D4, $SUV_{mean}$ recovered to origin below 80 kBq/ml. From 34 clinical patient's data, the average distance of misalignment was 2.02 cm and the average specific activity which makes washed-out artifact was 490.15 kBq/ml. The average $SUV_{mean}$ of muscles and the average $SUV_{max}$ of lesions in artifact slice before and after the correction show a significant difference according to a paired t-test respectively(t=-13.805, p=0.000)(t=-2.851, p=0.012), but the average $SUV_{max}$ of lesions out of artifact slice show a no significant difference (t=-1.173, p=0.250). Conclusion Scatter limitation correction algorism by GE PET/CT scanner helps to correct washed-out artifact from motion of a patient or high specific activity and to recover the PET images. When we read the image occurred with washed-out artifact by measuring the distance of misalignment between CT and PET image, specific activity after applying scatter limitation algorism, we can analyze the images more accurately without repeating scan.

A Study on Effects of the vocal psychotherapy upon Self-Consciousness (성악심리치료활동을 통한 자기의식 변화에 관한 연구)

  • Lee, Hyun Joo
    • Journal of Music and Human Behavior
    • /
    • v.4 no.2
    • /
    • pp.66-83
    • /
    • 2007
  • The purpose of this study is to learn both effects of the vocal psychotherapy on the self-consciousness and the variety of the self-consciousness on the vocal psychotherapy in return. The research for this study was performed to three subjects who were students of E university, Seoul, ten times for sixty minutes. The subjects were all volunteers for the advertisement on a music-therapy program searching for them on the web site of E university. The vocal psychotherapy program consists of four steps and each of them consists of two to four short terms again. Both before and after the experiment, examinations on self-consciousness were done to recognize the change of the subjects' self-consciousness which would be caused by the vocal psychotherapy activity. After every short term, the subjects were asked to write reports to closely analyze the change of self-consciousness according to the terms and the variety of the subjects. The effect of the vocal psychotherapy activity on the changes of scores in the self-consciousness examination is the first thing to point out on this study. There appeared some personal varieties on the total scores of the examination and scores of some sub-categories. Especially, there were different scores on the private self-consciousness, the public self-consciousness, and the social anxiety between before and after performing the vocal psychotherapy program. Subject A, who had got the best score of all on the scope of the private self-consciousness, showed the steepest decrease on the very scope. On the contrary, the subject showed decrease of scores of the public self-consciousness and the social anxiety in the relatively little rate. Subject B, who had got the highest score of the three on the public self-consciousness, showed the steepest decrease on that of all scopes and showed no difference on the social anxiety scope. In the case of the last one, subject C, who had relatively low scores on the private and public self-consciousness than the others, the private self-consciousness score increased but the public self-consciousness and the social anxiety scores decreased. The changes of the scores of each questions were examined in order to see possible other changes that had not been exposed on the changes of the total and sub-categories scores. As a result of that, of all twenty-eight questions, there were changes about one to two points. Subject A showed the difference with thirteen questions, subject B with sixteen and subject C with nineteen questions. The rate of change of subject C was relatively small but more questions changed and the change of score was wider than the others. Considering all those results, It can be possibly said that the vocal psychotherapy affects the changes of the scores of sub-categories in self-consciousness examination. The next thing to point out on this study is the change of recognition that was exposed on the subjects' report after every short term of the program. As a result of the close analyzing, according to the short terms and variety of self-consciousness, recognizing the way express subjects themselves by voice and recognizing their own voices appeared to be different. How much they cared about others and why they did so were also different. According to the self reports, subject A cared much about her inner thought and emotion and tended to concentrate herself as a social object. There appeared some positive emotional experiments such as emotional abundance and art curiosities on her reports but at the same time some negative emotions such as state-trait anxiety and neuroticism also appeared. Subject B, who showed high scores on the private and public self-consciousness like subject A, had a similar tendency that concentrates on herself as a social object but she showed more social anxiety than subject A. Subject C got relatively lower points in self-consciousness examination, tended to care about herself, and had less negative emotions such as state-trait anxiety than other subjects. Also, with terms going on, she showed changes in the way of caring about her own voice and others. This study has some unique significances in helping people who have problems caused by self-estimation activated with self-consciousness, using voices closely related to one's own self, performing the vocal skills discipline to solve the technical problems. Also, this study has a potentiality that the vocal psychotherapy activity can be effectively used as a way affects the mental health and developing personality.

  • PDF

A Critical Evaluation of the Correlation Between Biomarkers of Folate and Vitamin $B_{12}$ in Nutritional Homocysteinemia (엽산과 비타민 $B_{12}$ 결핍에 의한 호모시스테인혈증 흰쥐의 조직내 비타민 지표간의 상관관계 분석)

  • Min, Hye-Sun;Kim, Mi-Sook
    • Journal of Nutrition and Health
    • /
    • v.42 no.5
    • /
    • pp.423-433
    • /
    • 2009
  • Folate and vitamin $B_{12}$ are essential cofactors for homocysteine (Hcy) metabolism. Homocysteinemia has been related with cardiovascular and neurodegenerative disease. We examined the effect of folate and/or vitamin $B_{12}$ deficiency on biomarkers of one carbon metabolism in blood, liver and brain, and analyzed the correlation between vitamin biomarkers in mild and moderate homocysteinemia. In this study, Sprague-Dawley male rats (5 groups, n = 10) were fed folatesufficient diet (FS), folate-deficient diet (FD) with 0 or 3 g homocystine (FSH and FDH), and folate-/vitamin $B_{12}$-deficient diet with 3 g homocystine (FDHCD) for 8 weeks. The FDH diet induced mild homocysteinemia (plasma Hcy 17.41 ${\pm}$ 1.94 nmol/mL) and the FDHCD diet induced moderate homocysteinemia (plasma Hcy 44.13 ${\pm}$ 2.65 nmol/mL), respectively. Although liver and brain folate levels were significantly lower compared with those values of rats fed FS or FSH (p < 0.001, p < 0.01 respectively), there were no significant differences in folate levels in liver and brain among the rats fed FD, FDH and FDHCD diet. However, rats fed FDHCD showed higher plasma folate levels (126.5 ${\pm}$ 9.6 nmol/L) compared with rats fed FD and FDH (21.1 ${\pm}$ 1.4 nmol/L, 22.0 ${\pm}$ 2.2 nmol/L)(p < 0.001), which is the feature of "ethyl-folate trap"by vitamin $B_{12}$ deficiency. Plasma Hcy was correlated with hepatic folate (r = -0.641, p < 0.01) but not with plasma folate or brain folate in this experimental condition. However, as we eliminated FDHCD group during correlation test, plasma Hcy was correlated with plasma folate (r = -0.581, p < 0.01), hepatic folate (r = -0.684, p < 0.01) and brain folate (r = -0.321, p < 0.05). Hepatic S-adenosylmethionine (SAM) level was lower in rats fed FD, FDH and FDHCD than in rats fed FS and FSH (p < 0.001, p < 0.001 respectively) and hepatic S-adenosylhomocysteine (SAH) level was significantly higher in those groups. The SAH level in brain was also significantly increased in rats fed FDHCD (p < 0.05). However, brain SAM level was not affected by folate and/or vitamin $B_{12}$ deficiency. This result suggests that dietary folate- and vitamin B12-deficiency may inhibit methylation in brain by increasing SAH rather than decreasing SAM level, which may be closely associated with impaired cognitive function in nutritional homocysteinemia.

Energy expenditure measurement of various physical activity and correlation analysis of body weight and energy expenditure in elementary school children (일부 초등학생의 대표적 신체활동의 에너지소비량 측정 및 에너지소비량과 체중과의 상관성 분석)

  • Kim, Jae-Hee;Son, Hee-Ryoung;Choi, Jung-Sook;Kim, Eun-Kyung
    • Journal of Nutrition and Health
    • /
    • v.48 no.2
    • /
    • pp.180-191
    • /
    • 2015
  • Purpose: There is a lack of data on the energy cost of children's everyday activities, adult values are often used as surrogates. In addition, the influence of body weight on the energy cost of activity when expressed as metabolic equivalents (METs) has not been vigorously explored. Methods: In this study 20 elementary school students 9~12 years of age completed 18 various physical activities while energy expenditure was measured continuously using a portable telemetry gas exchange system ($K_4b^2$, Cosmed, Rome, Italy). Results: The average age was 10.4 years and the average height and weight was 145.1 cm and 43.6 kg, respectively. Oxygen consumption ($VO_2$), energy expenditure and METs at the time of resting of the subjects were 5.41 mL/kg/min, 1.44 kcal/kg/h, and 1.5 METs, respectively. METs values by 18 physical activities were as follows: Homework and reading books (1.6 METs), playing game with a mobile phone or video while sitting (1.6 METs), watching TV while sitting on a comfortable chair (1.7 METs), playing video game or mobile phone game while standing (1.9 METs), sweeping a room with a broom (2.7 METs) and playing a board game (2.8 METs) belong to light intensity physical activities. By contrary, speedy walking and running were 6.6 and 6.7 METs, respectively, which belong to high intensity physical activities over 6.0 METs. When the effect of body weight on physical activity energy expenditure was determined, $R^2$ values increased with 0.116 (playing a game at sitting), 0.176 (climbing up and down stairs), 0.246 (slow walking), and 0.455 (running), which showed that higher activity intensity increased explanation power of body weight on METs value. Conclusion: This study is important for direct evaluation of energy expenditure by physical activities of children, and it could be used directly for revising and complementing the existing activity classification table to fit for children.

The Developmental Effects of Radiation on ICR Mouse Embryos in Preimplantation Stage (착상전기(着床前期)에 있어서 ICR Mouse의 태아(胎兒)에 대한 방사선(放射線) 개체(個體) Level 영향(影響)의 연구(硏究))

  • Gu, Yeun-Hwa
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.4
    • /
    • pp.273-284
    • /
    • 1996
  • Embryos and fetuses are more sensitive to various environmental agents than are adults or children. The biological effects such as intrauterine death and malformation are closely connected with prenatal exposure very various agents. The sensitivity of these embryonic/fetal effects depends on the stage of pregnancy. From the viewpoint of fetal development, embryonic and fetal stages can be divided into three stages : Preimplantation, organogenetic and fetal. Each stage corresponds to 0 to 4.5days, 4.5 to 13.5days, and 13.5days of gestation in mice, respectively. Many studies on the biologcal effects of mice irradiated by ${\gamma}-rays$ at various stages during organogenesis and fetal period have been performed. Based on these results, the dose-effect and dose-response relationships in malformations, intrauterine death, or retardation of the physical growth have been practically modeled by the ICRP(International Commission on Radiological Protection) and other international bodies for radiation protection. Many experimental studies on mice have made it clear that mice embryos in the preimplantation period have a higher sensitivity to radiation for lethal effects than the embryos/fetuses on other prenatal periods. However, no eratogenic effects of radiation at preimplantation stages of mice have been described in many textbooks. It has been believed that 'all or none action results' for radiation of mice during the preimplantation period were applied. The teratogenic and lethal effects during the preimplantation stage are one of the most important problems from the viewpoint of radiological protection, since the preimplantation stage is the period when the pregnancy itself is not noticed by a pregnant woman. There are many physical or chemical agents which affect embryos/fetuses in the environment. It is assumed that each agents indirectly effects a human. Then, a safety criterion on each agent is determined independently. The pregnant ICR mice on 2, 48, 72 or 96 hours post-conception (hpc), at which are preimplantation stage of embryos, were irradiated whole body Cesium-gamma radiation at doses of 0.1, 0.25, 0.5, 1.5, and 2.5 Gy with dose rate of 0.2 Gy/min. In the embryos from the fetuses from the mice irradiated at various period in preimplantation, embryonic/fetal mortalities, incidence of external gross malformation, fetal body weight and sex ratio were observed at day 18 of gestation. The sensitivity of embryonic mortalities in the mice irradiated at the stage of preimplantation were higher than those in the mice irradiated at the stage of organogenesis. And the more sensitive periods of preimplantation stage for embryonic death were 2 and 48 hpc, at which embryos were one cell and 4 to 7 cell stage, respectively. Many types of the external gross malformations such as exencephaly, cleft palate and anophthalmia were observed in the fetuses from the mice irradiated at 2, 72 and 96 hpc. However, no malformations were observed in the mice irradiated at 48 hpc, at which stage the embryos were about 6 cell stage precompacted embryos. So far, it is believed that the embryos on preimplantation stage are not susceptible to teratogens such as radiation and chemical agents. In this study, the sensitivity for external malformations in the fetuses from the mice irradiated at preimplantation were higher than those in the fetuses on stage of organogenesis.

  • PDF