• Title/Summary/Keyword: Edge-to-edge repair

Search Result 80, Processing Time 0.026 seconds

Arthroscopic Treatment of Metallic Suture Anchor Failures after Bankart Repair (Bankart 수술 후 발생한 금속 봉합 나사못 합병증의 관절경적 치료)

  • Shin, Sang-Jin;Jung, Jae-Hoon;Kim, Sung-Jae;Yoo, Jae-Doo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.1
    • /
    • pp.70-76
    • /
    • 2006
  • Purpose: This study presents 5 patients who had metallic anchor protrusion on glenoid after Bankart repair in anterior shoulder instability and reviewed the cause, clinical feature and arthroscopic removal technique. Method and Materials: 5 male with average age of 22 years (range 19 to 25 years) were included. 4 patients had arthroscopic Bankart repair and 1 patient had open repair for anterior shoulder instability. They had protruded metallic suture anchors on glenoid and the protruded suture anchors were removed arthroscopically using larger suture anchor empty inserter. Results: 4 patients had painful clicking sound with motion of abduction and external rotation and 1 patient showed shoulder instability. The ROM showed normal except mild degrees loss of external rotation. The position of protruded metallic anchor was 2, 3 and 5 O'clock in three patients and 4 O'clock in 2 patients. In 2 patients, the metallic suture anchor was malpositioned about 5mm off on the medial side from the anterior glenoid edge. All had Outerbrige classification Grade II-III chondral damage on humeral head and 1 patient showed glenoid cartilage destruction. None had shoulder instability after 2 years of follow-up. Constant score was 65 preoperatively and 89 postoperatively. ASES score was 67 preoperatively and 88 postoperatively. Conclusion: Symptoms of protruded suture anchor are not combined with instability. Most of symptoms were revealed from the rehabilitation period and confused with postoperative pain. Prompt diagnosis and early arthroscopic removal or impaction of protruded metallic suture anchor is recommended because of serious glenohumeral cartilage destruction. This is easy and simple and reproducible method to remove protruded metallic suture anchor arthroscopically.

  • PDF

The Use of Hyalomatrix$^{(R)}$ in the Treatment of Difficult To Heal Wound (치료하기 어려운 창상에서 하이알로매트릭스$^{(R)}$의 사용)

  • Koo, Hyun-Kook;Kim, Young-Seok;Hong, Jong-Won;Roh, Tai-Suk;Rah, Dong-Kwun
    • Archives of Plastic Surgery
    • /
    • v.37 no.5
    • /
    • pp.600-606
    • /
    • 2010
  • Purpose: Although traditional and current treatment strategies may demonstrate success, persistence or recurrence of difficult-to-heal wounds remain significant problems. A novel product, Hyalomatrix$^{(R)}$ (Fidia Advanced Biopolymer, Abano Terme, Italy) is a bilayer of an benzyl esterified hyaluronan scaffold beneath a silicone membrane. The scaffold delivers hyaluronan to the wound, and the silicone membrane acts as a temporary epidermal barrier. We present the results obtained with Hyalomatrix$^{(R)}$ in the treatment of difficult-to-heal wounds. Methods: From November, 2008 to March, 2010, Hyalomatrix$^{(R)}$ has been used on total 10 patients with wounds that were expected difficult to heal with traditional and other current strategies. After average 37.4 days from development of wounds, Hyalomatrix$^{(R)}$ was applied after wound debridement. On the average, Hyalomatrix$^{(R)}$ application period was 17.6 days. After average 16.5 days from removal of Hyalomatrix$^{(R)}$, skin grafts was performed. Results: In all cases, regeneration of fibrous granulation tissues and edge re-epithelization were present after the application of the Hyalomatrix$^{(R)}$. And all of the previous inflammatory signs were reduced. After skin grafts, no adverse reactions were recorded in 9 cases. But in one case, postoperative wound infection occured due to a lack of efficient fibrous tissues. In this model, the Hyalomatrix$^{(R)}$ acts as a hyaluronan delivery system and a barrier from the external environments. In tissue repair processes, the hyaluronan performs to facilitate the entry of a large number of cells into the wounds, to orientate the deposition of extracellular matrix fibrous components and to change the microenvironment of difficult-to-heal wounds. Conclusion: Our study suggests that Hyalomatrix$^{(R)}$ could be a good and feasible approach for difficult-to-heal wounds. The Hyalomatrix$^{(R)}$ improves microenvironments of difficult-to-heal wounds, reduces infection rates and physical stimulus despite of aggravating factors.

Evaluation of Adhesion Characteristics of Crack Sealants Used in Asphalt Concrete Pavement (아스팔트 콘크리트 포장용 균열실링재의 부착특성 평가)

  • Lee, Jae-Jun;Kim, Seung-Hoon;Baek, Jong-Eun;Lim, Jae-Kyu;Kim, Yong-Joo
    • International Journal of Highway Engineering
    • /
    • v.17 no.2
    • /
    • pp.55-62
    • /
    • 2015
  • Cracking is an inevitable fact of asphalt concrete pavements and plays a major role in pavement deterioration. Pavement cracking is one of the main factors determining the frequency and method of repair. Cracks can be treated with a number of preventative maintenance actions, including overlay surface treatments such as slurry sealing, crack sealing, or crack filling. Pavement cracks can show up as one or all of the following types: transverse, longitudinal, fatigue, block, reflective, edge, and slippage. Crack sealing is a frequently used pavement maintenance treatment because it significantly extends the pavement service life. However, crack sealant often fails prematurely due to a loss of adhesion. Because current test methods are mostly empirical and only provide a qualitative measure of the bond strength, they cannot accurately predict the adhesive failure of the sealant. This study introduces a laboratory test aimed at assessing the bonding of hot-poured crack sealant to the walls of pavement cracks. A pneumatic adhesion tensile testing instrument (PATTI) was adopted to measure the bonding strength of the hot-poured crack sealant as a function of the curing time and temperature. Based on a limited number of test results, the hot-poured crack sealants have very different bonding performances. Therefore, this test method can be proposed as part of a newly developed performance-based standard specification for hot-poured crack sealants for use in the future. PURPOSES : The purpose of this study was to evaluate both the adhesion and failure performance of a crack sealant as a function of its curing time and curing temperature. METHODS: A pneumatic adhesion tensile testing instrument (PATTI) was adopted to measure the adhesion performance of a crack sealant as a function of the curing time and curing temperature. RESULTS: With changes in the curing time, curing temperature, and sealant type, the bond strengths were found to be significantly different. Also, higher bond strengths were measured at lower temperatures. Different sealant types produced completely different bond strengths and failure behaviors. CONCLUSIONS: The bonding strength of an evaluated crack sealant was shown to differ depending on various factors. Two sealant types, which were composed of different raw materials, were shown to perform differently. The newly proposed test offers the possibility of evaluating and differentiating between different crack sealants. Based on alimited number of test results, this test method can be proposed as part of a newly developed performance-based standard specification for crack sealants or as part of a guideline for the selection of hot-poured crack sealant in the future.

A Study of Metalworking Techniques Seen in the Gold Buckle from Seogam-ri Tomb No. 9 (석암리 9호분 출토 금제띠고리의 제작 방법 고찰)

  • Ro, Jihyun;Yu, Heisun
    • Conservation Science in Museum
    • /
    • v.17
    • /
    • pp.1-16
    • /
    • 2016
  • The gold buckle excavated from Seogam-ri Tomb No. 9(National Treasure No. 189), one of the oldest gold artifacts discovered within the Korean Peninsula, was created using granulation techniques. The buckle is made with 22.8K gold sheets and features a decorative design with seven dragons in repousse metalwork. The outlines of the dragons and the edge of the buckle are finished with 23.8K gold wires and granules. Some curved sections of the buckle are also covered with an extra sheet of 23.8K gold, possibly added to repair defects discovered during production or thereafter. Gold wire used to render the dragon's nostrils is slightly lower in purity(23.3K) and was probably preferred in this case due to its increased hardness. As a result, the metal is better able to retain the complex shape of the dragons' nostrils, created by rolling gold wire into spirals. The buckle's gold granules are found in small, medium and large sizes and are presumed to have been bonded using copper. The foreheads and the bodies of the seven dragons are inset with turquoise and the eyes are decorated with red cinnabar/vermillion(HgS).

Research & Development on the Scaffolding for Cylindrical Desulfurizers Facility Maintenance (원통형 탈황설비 정비용 비계 연구개발)

  • Lee, Kwang-Gil;Kim, Woo-Gon;Eum, Seok-Ho;Kang, Cheol-Min;Kang, Jeong-Ki;Oh, Cheol-Seok;Seo, Ju-Sik;Kim, Kyeong-Jae;Park, Jong-In;Jang, Mong-Yong;Kim, Moo-Seong;Kim, Dae-Nyeon;Jung, Soo-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.3
    • /
    • pp.1-8
    • /
    • 2020
  • The desulfurizers facility is cylindrical shape. To operate properly it needs nozzles cleaned, get rid of lime adhesion and sludge, repair the wear and corrosion of facility regularly. For this purpose, workers shall access the ceiling or vertical wall at high place. Ordinary scaffoldings such as steel pipe scaffolding or system scaffolding have been using so that workers can access them. With these ordinary scaffoldings, openings around cylindrical wall are inevitable which make workers can expose always to the risk of falling. The purpose of this study is to develop customized scaffolding to minimize the openings to prevent workers form falling during maintenance it. It consists of a hexagonal central tower and six trapezoidal outer towers. And the bracing among the towers have connected each other for self-standing and for maintaining the structure of towers. Span decks, the circumference footstools, steps, etc. are laid on each floor. The safety is reviewed by structural analysis and performance test. With this study, openings each floor of this scaffold are removed. The gap between the cylindrical wall and the edge of the work stage is approximately 100 mm. Therefore, we expect that workers can work safely and efficiently.

Transcriptional Profiling of Differentially Expressed Genes in Porcine Satellite Cell

  • Jeong, Jin Young;Kim, Jang Mi;Rajesh, Ramanna Valmiki;Suresh, Sekar;Jang, Gul Won;Lee, Kyung-Tai;Kim, Tae Hun;Park, Mina;Jeong, Hak Jae;Kim, Kyung Woon;Cho, Yong Min;Lee, Hyun-Jeong
    • Reproductive and Developmental Biology
    • /
    • v.37 no.4
    • /
    • pp.233-245
    • /
    • 2013
  • Muscle satellite cell (SC) is responsible for postnatal muscle growth, repair, and regeneration. Satellite cell is an important source of multi-potent stem cell process and differentiation into adipogenic, myogenic, and osteoblastogenic. The objective of this study was to identify alter of transcriptome during differentiation in porcine satellite cell and to elevated transcriptome at different stages of postnatal development to gain insight into the differences in differentiated PSC. We used RNA-seq technique to investigate the transcriptomes during differentiation in pig muscle. Sequence reads were obtained from Illumina HiSeq2000. Differentially expressed genes (DEG) were detected by EdgeR. Gene ontology (GO) terms are powerful tool for unification among representation genes or products. In study of GO biological terms, functional annotation clustering involved in cell cycle, apoptosis, extracellular matrix, phosphorylation, proteolysis, and cell signaling in differences stage. Taken together, these results would be contributed to a better understanding of muscle biology and processes underlying differentiation. Our results suggest that the source of DEGs could be better understanding of the mechanism of muscle differentiation and transdifferentiation.

A Suture Bridge Transosseous-Equivalent Technique for Bankart Lesions with Deficient Bony Stability - Technical Note - (골안정성 결손을 가진 Bankart 병변에 대한 경 골-유사 교량형 봉합술식 - 술기 보고 -)

  • Choi, Chang-Hyuk;Kim, Shin-Kun;Chang, Il-Woong;Chae, Sung-Bum
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.2
    • /
    • pp.179-182
    • /
    • 2009
  • Purpose: Point fixation at the margin of the glenoid is a limitation of conventional arthroscopic stabilization using suture anchors, and does not afford sufficient footprint healing, especially in glenoid bone deficiency. So, we introduce an arthroscopic suture bridge transosseous-equivalent technique for bony Bankart lesions to avoid the technical disadvantage of point contact with anchor fixation and to improve mechanical stability through cross compression of the labrum. Surgical approach: The technique was adapted from the transosseous-equivalent rotator cuff repair technique using suture bridges, which improved the pressurized contact area and mean pressure between the tendon and footprint. After preparation of the glenoid bed by removal, reshaping, or mobilization of the bony lesion, two anchors (3.0 mm Biofastak, $Arthrex^{(R)}$, Naples, FL) were inserted into the superior and inferior portion of the bony Bankart lesion. Using a suture hook, medial mattress sutures were applied around the capsulolabral portion of the IGHL complex to obtain sufficient depth of glenoid coverage. A 3.5 mm pushloc anchor ($Arthrex^{(R)}$, Naples, FL) hole was made in the articular edge of the anterior glenoid rim. distal, suture bridge was applied, and proximal was inserted to mobilize the labrum in the proximal direction. This avoided the technical disadvantage of point contact with anchor fixation and decreased the level of gap formation through cross-compression of the labrum.

  • PDF

Aortic Valvuloplasty Using Triangular Resection lechniolue (설상절제술(triangular resection)을 사용한 대동맥판막 성형술의 단기 성적)

  • 김욱성;정철현;허재학;백만종;이석기;박영관;김종환;장우익;장지민
    • Journal of Chest Surgery
    • /
    • v.35 no.2
    • /
    • pp.113-117
    • /
    • 2002
  • With an increasing awareness of the limitations of both mechanical prostheses and bioprostheses, aortic valvuloplasty has gained attention as an alternative procedure for aortic valve disease. Material and Method: Eight consecutive patients underwent aortic valvuloplasty caused by leaflet prolapse between June 1799 to June 2000. Mean age of the patients was 18.4$\pm$12.6 year. Four paitents(50%) were male. Six patients had tricuspid valves and ventricular septal defect and two patients had bicuspid valves. The extent of aortic insufficiency was 3.5$\pm$0.5 by preoperative Doppler echocardiography. The technique involved triangular resection of the free edge of the prolapsed leaflet, annular plication at the commissure, and resection of a raphe when present in bicuspid valves. Result: There was no in-hospital mortality or morbidity. Mean follow-up was complete at 11.973.6months. There was no late mortality or morbidity. The amount of the severity of aortic insufficiency, as assessed by echocardiography preoperatively, postoperatively and at late follow-up was 3.5$\pm$0.5, 0.6$\pm$0.5 and 0.8$\pm$0.6, respectively(p value : 0.01). There was one patient with grade 2/4 aortic insufficiency and in the other patients, grade 1/2 or trivial aortic insufficiency were detected with late echocardiograms. Conclusion: Triangular resection in the patients with aortic leaflet prolapse offers a good early clinical result, but long-term follow-up is necessary.

A Study on the Arrangements of YangjinDang in Sang-ju Foundation by Date on the Excavation and Jungsuki (중수기 및 발굴 자료로 본 상주 양진당의 배치에 관한 연구)

  • Kim, Chan-Yeung;Chung, Myung-Sup
    • Journal of architectural history
    • /
    • v.20 no.4
    • /
    • pp.61-80
    • /
    • 2011
  • This study estimated the prototype of Yangjindang at the time of its foundation by putting together the literature and discovered data and historical research on family related to Sangju Yangjindang, and looked at its architectural characteristics. These are summarized as follows: First, Yangjindang is an office building which was completed in three years [1629] after its start of construction when Keomgan Jojeong was at the age of 72 [1626] in his latter days and it was used for performing ancestral rites for Jojeong's forefathers of the head family of Pungyang Jo by family origin. Yangjindang was founded as a base of utopia for putting ancestral rites & commemoration, harmoniousness of a tribe, and educational idea into practice together with Ojakdang. Such a movement can be judged to interpret and apply the circumstances of the times realistically and flexibly where they tried to pursue the promotion of Confucianism & studies of the proprieties as well as the consciousness of practice, and to bring a tribe into harmony after the war through the retirement of Toegye School. Second, it is located at a topographically ideal spot on the edge of the Jangcheon-a tributary of Nakdong with a good physiology and landscape and its location was also the lot for a house of Jojeong's ancestor, which was burned down by war. Behind such a location and planning of Yangjindang, it is presumed, though not certain that it was modelled after Naeap village at Andong- Jojeong's parents-in-low's home. Third, as for its foundation size, it's a head house as much as about more than 100-kan, and its structure is composed of Samyo, Bonche, and Yangjindang. In addition, arrangements of buildings and its composition system and renovation procedures followed Chu-tzu Garyoe. Composition of Samyo can be restored to Yangjindang, Jugo, Woesammun, and Samyo; however, there has been no case of existence in case of Jugo building composition & arrangement takes on an aspect of a compromise between Gamyojido and Sandangjido of Garoe, which seems to be the result from flexibly interpreting and applying the rituals and studies of the proprieties of Toegye School in keeping with locational topography and realistic circumstances while making it a principle for them to observe by Toegye School. There exists a difference between Bonche and its counterpart of the upper class housing at Sangju district in that Bonche[main building] is a squre-shaped 'Ttuljip' typical of Andong setting a family ancestral ritual as a main function. Fourth, there existed a lot of hardships in raising money to cover repairs in time of doing repairs to this structure after 180 years since its establishment. In case of the repair work on Bonche, the level of renovation was limited to the replacement of old materials for rafters, doorpost, roof members and railings with new materials, together with partial alterations in case of window system. It is estimated that Yangjindang was renovated in 1808, and afterwards it was renamed Okryujeong after being re-built at another site. Through the repairs, the floor was expanded for the clan's meeting, and angle rafters and roof members were mended as well. Especially, the plane and structure of Okryujeong which was re-built at another site are expected to give clues to its restoration due to the resemblance to original appearance of Yangjindang at the time of its renovation in 1808.

Properties of Components for the Dapogye of Hipped and Gable Roof Wooden Buildings (합각지붕 사찰 주불전의 규모에 따른 기둥 및 처마부 관계분석 연구)

  • Go, Jung-Ju;Lee, Jeong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3192-3202
    • /
    • 2014
  • This study has its purposes on analyzing specific features of the elements according to scales of 32 main buddhist sancta among wooden temples with gable roof that are nationally designated as cultural assets, and analyzing influences and proportional relations between main and submaterials, so that it could be basic and objective data for restore and repair cultural assets in the future. Results of the study are following. First of all, the average plane proportion of doritong (facade) and yangtong (side) in 3-room building is about 1.31:1, while it is 1.70:1 in 5-room building. Secondly, as a result of analyzing the locational proportion and thickness of pillars at each location, floor room turned out to have wider space between pillars than that of edge room or side room in both cases of 3 and 5-room buildings. In the mean time, for the average thickness of the pillars in 3-room building, it was 491mm for corner pillars, 433mm for general pillars in cases of 3-room building, while it was 595 and 511mm respectively in cases of 5-room building. The reason why corner pillars are 60~80mm thicker than general ones in average, is determined to considered structural stability and optical illusion. For the third, as a result of analyzing the influences on pillar thickness, eaves projection and eaves height according to the scale(dimension) of buildings, 3-room buildings have outstanding correlation as its scale(dimension) goes bigger, while 5-room ones are not very much influenced by its scale(dimension). For the fourth, as a result of the relation between pillars and eaves, both of 3 and 5-room buildings have longer-projected and higher eaves as their pillars go taller; especially height of eaves turns out to have very close relation between length of pillars. In addition to that, both of 3 and 5-room buildings have much projected eaves as the eaves go higher.