Verification of Microstructure Qualities of ACR-Approved Mammography Phantoms by Refraction-Enhanced Synchrotron Radiation Imaging

  • Imamura, Keiko;Ehara, Norishige;Inada, Yoichi;Miyamoto, Keiko;Kanemaki, Yoshihide;Umetani, Keiji;Uesugi, Kentaro;Ochiai, Yoshinori;Fukuda, Mamoru;Nakajima, Yasuo
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.415-417
    • /
    • 2002
  • Images of microcalcification specks showed large variation in conventional radiographs of phantoms which are approved for mammography image quality standard by the American College of Radiology (ACR). This kind of variation is not appropriate for image quality standards because the number of specks are visually counted in images and that number is important in image quality evaluation. Our study using synchrotron radiation (SR) imaging revealed the overlapping of micro-sized air bubble(s) to some specks, and also the structural deformation or crackings. Eight phantoms approved by ACR from two different makers and an air-bubble phantom were examined. SR imaging was performed at a synchrotron radiation facility, SPring-8, in Japan. The image-detector was a fluorescent-screen optical-lens coupling system using a CCD camera with a spatial resolution of 6 $\square$m. Objects when imaged with longer sample-to-detector distance show edge enhancement due to a difference in refraction indices, that is refraction enhancement. Refraction-enhanced SR images revealed that some of specks carried foreign objects, which were proven to be air. In phantoms provided by one maker, attaching/overlapping airs were observed for 62 out of 150 specks (41%) , with a higher incidence for the smallest specks. A speck becomes hardly visible in a conventional radiograph when air(s) overlaps the majority part of a speck, though depending on the size of the air-inclusion and on its configuration. Those airs might have been adsorbed on a speck surface before being embedded and then introduced into the matrix together with specks. Our study using SR imaging has clearly shown the nature of defects in some mammography phantoms which seriously degrade the quality as an image standard.

  • PDF

Evaluation of Source Identification Method Based on Energy-Weighting Level with Portal Monitoring System Using Plastic Scintillator

  • Lee, Hyun Cheol;Koo, Bon Tack;Choi, Chang Il;Park, Chang Su;Kwon, Jeongwan;Kim, Hong-Suk;Chung, Heejun;Min, Chul Hee
    • Journal of Radiation Protection and Research
    • /
    • 제45권3호
    • /
    • pp.117-129
    • /
    • 2020
  • Background: Radiation portal monitors (RPMs) involving plastic scintillators installed at the border inspection sites can detect illicit trafficking of radioactive sources in cargo containers within seconds. However, RPMs may generate false alarms because of the naturally occurring radioactive materials. To manage these false alarms, we previously suggested an energy-weighted algorithm that emphasizes the Compton-edge area as an outstanding peak. This study intends to evaluate the identification of radioactive sources using an improved energy-weighted algorithm. Materials and Methods: The algorithm was modified by increasing the energy weighting factor, and different peak combinations of the energy-weighted spectra were tested for source identification. A commercialized RPM system was used to measure the energy-weighted spectra. The RPM comprised two large plastic scintillators with dimensions of 174 × 29 × 7 ㎤ facing each other at a distance of 4.6 m. In addition, the in-house-fabricated signal processing boards were connected to collect the signal converted into a spectrum. Further, the spectra from eight radioactive sources, including special nuclear materials (SNMs), which were set in motion using a linear motion system (LMS) and a cargo truck, were estimated to identify the source identification rate. Results and Discussion: Each energy-weighted spectrum exhibited a specific peak location, although high statistical fluctuation errors could be observed in the spectrum with the increasing source speed. In particular, 137Cs and 60Co in motion were identified completely (100%) at speeds of 5 and 10 km/hr. Further, SNMs, which trigger the RPM alarm, were identified approximately 80% of the time at both the aforementioned speeds. Conclusion: Using the modified energy-weighted algorithm, several characteristics of the energy weighted spectra could be observed when the used sources were in motion and when the geometric efficiency was low. In particular, the discrimination between 60Co and 40K, which triggers false alarms at the primary inspection sites, can be improved using the proposed algorithm.

미소 중력장에 있는 저신장율 화염소화에 미치는 다차원 효과 (Multi-Dimensional Effects on a tow Strain Rate Flame Extinction Under Microgravity Environment)

  • 오창보;김정수;;박정
    • 대한기계학회논문집B
    • /
    • 제29권9호
    • /
    • pp.988-996
    • /
    • 2005
  • Flame structure and extinction mechanism of counterflow methane/air non-premixed flame diluted with nitrogen are studied by NASA 2.2 s drop tower experiments and two-dimensional numerical simulations with finite rate chemistry and transport properties. Extinction mechanism at low strain rate is examined through the comparison among results of microgravity experiment, 1D and 2D simulations with a finite burner diameter. A two-dimensional simulation in counterflow flame especially with a finite burner diameter is shown to be very important in explaining the importance of multidimensional effects and lateral heat loss in flame extinction, effects that cannot be understood using a one-dimensional flamelet model. Extinction mechanism at low strain rate is quite different from that at high strain rate. Low strain rate flame is extinguished initially at the outer flame edge, the flame shrinks inward, and finally is extinguished at the center. It is clarified from the overall fractional contribution by each term in energy equation to heat release rate that the contribution of radiation fraction with 1D and 2D simulations does not change so much and the overall fractional contribution is decisively attributed to radial conduction ('lateral heat loss'). The experiments by Maruta et at. can be only completely understood if multi-dimensional heat loss effects are considered. It is, as a result, verified that the turning point, which is caused only by pure radiation heat loss, has to be shifted towards much lower global strain rate in microgravity flame.

Prediction Model of the Outer Radiation Belt Developed by Chungbuk National University

  • Shin, Dae-Kyu;Lee, Dae-Young;Kim, Jin-Hee;Cho, Jung-Hee
    • Journal of Astronomy and Space Sciences
    • /
    • 제31권4호
    • /
    • pp.303-309
    • /
    • 2014
  • The Earth's outer radiation belt often suffers from drastic changes in the electron fluxes. Since the electrons can be a potential threat to satellites, efforts have long been made to model and predict electron flux variations. In this paper, we describe a prediction model for the outer belt electrons that we have recently developed at Chungbuk National University. The model is based on a one-dimensional radial diffusion equation with observationally determined specifications of a few major ingredients in the following way. First, the boundary condition of the outer edge of the outer belt is specified by empirical functions that we determine using the THEMIS satellite observations of energetic electrons near the boundary. Second, the plasmapause locations are specified by empirical functions that we determine using the electron density data of THEMIS. Third, the model incorporates the local acceleration effect by chorus waves into the one-dimensional radial diffusion equation. We determine this chorus acceleration effect by first obtaining an empirical formula of chorus intensity as a function of drift shell parameter $L^*$, incorporating it as a source term in the one-dimensional diffusion equation, and lastly calibrating the term to best agree with observations of a certain interval. We present a comparison of the model run results with and without the chorus acceleration effect, demonstrating that the chorus effect has been incorporated into the model to a reasonable degree.

다엽 콜리메이터의 임상적용을 위한 엽측간 투과선량 및 엽종단간 투과선량 연구 (A Study on Inter-leaf Transmission and Cross-leaf Transmission for Clinical Applications of the Multileaf Collimator)

  • 이규찬;최진호
    • 한국의학물리학회지:의학물리
    • /
    • 제15권1호
    • /
    • pp.17-22
    • /
    • 2004
  • Multileaf collimator (MLC) is now rapidly replacing the lead ahoy block to shape the radiation treatment field. In addition to its defect of rectangular field shaping and increased penumbra width, it has another possible problem, and that is of radiation transmission between leaves, which needs to be maintained at as low a level as is permissible. The authors measured and analyzed the inter-leaf and cross-leaf transmissions of MLC by Varian Associates Inc, before its clinical application. The inter-leaf and cross-leaf transmissions were calculated by comparing the measured point doses in the polystyrene phantom in the open field and in a total closure of MLC. The beam profile of the inter-leaf and cross-leaf transmissions were depicted by using a water phantom. A photon beam of 6 MV was used in the measurement. The inter-leaf transmission was 1.63∼1.67%, indicating that the shielding effect of MLC is excellent. However, the cross-leaf transmission in the central area was 18.4∼18.7% and this is well over the clinically acceptable limitation of 5%. The beam profile of cross-leaf transmission displayed 80∼90% transmission near the field edge, so that the cross-leaf transmission was 14∼17% in this area. The multileaf collimator has an excellent shi디ding effect and the inter-leaf transmission is negligible so that it can be used in clinic as a good replacement of the conventional lead alloy block. However, care must be taken to avoid the cross-leaf transmission in the radiation field.

  • PDF

구내 방사선발생기의 선량 분포측정을 통한 필름유지기구(XCP-DS FIT)의 피폭선량감소에 대한 유용성 (Utilization-Focused Reduction of Radiation Exposure with XCP-DS FIT Sensor Holder by Measuring Dose of Dental X-ray Generator)

  • 이경희
    • 한국방사선학회논문지
    • /
    • 제6권6호
    • /
    • pp.465-471
    • /
    • 2012
  • 본 연구에서는 ALOKA PDM-117(X-ray 측정용 선량계)선량계를 이용하여 구내방사선 촬영기에서 발생하는 방사선에 대하여 거리의 변화에 따른 선량분포를 3차원으로 측정하였다. 구내 방사선촬영에 있어서 XCP 필름 유지기구(XCP-DS FIT)를 사용하여 영상을 얻는 경우 방사선의 선량 분포는 변할 수 있고 이것은 방사선영상과 환자피폭에 영향을 미치게 된다. 따라서 위치에 따른 선량을 표준화하여 XCP 필름 유지기구 사용 유무에 따른 선량과의 관계를 알아볼 필요성이 있다. 본 연구에서는 측정된 3차원 선량분포를 통하여 등각촬영시 얻을 수 있는 최적의 영상과 동일한 선량을 얻기 위한 조사시간과 거리와의 관계 및 선량분포의 모서리 퍼짐 현상에 대한 결과를 정량적으로 측정하였다. 거리가 증가함에 따라 중심 선량은 감소하였지만 조사통 가장자리 부분의 방사선 퍼짐은 증가하는 경향을 보였다. 이것은 XCP 필름 유지기구를 사용하는 경우에 선속 가장자리 부분에서 방사선의 선량이 퍼지는 경향을 보이기 때문이므로 환자의 병소이외의 부분에 대한 피폭에 주의를 기울여야 함을 정량적으로 확인 하였다. 본 연구의 결과는 품질 좋은 치아영상을 얻고, 환자의 피폭선량을 줄이는데 매우 유용하게 사용되어 질 수 있을 것으로 사료된다.

금속쐐기와 기능강화동적쐐기의 조사야 주변부 선량 비교 (A Comparison of Peripheral Doses Scattered from a Physical Wedge and an Enhanced Dynamic Wedge)

  • 박종민;김희정;민제순;이제희;박찬일;예성준
    • 한국의학물리학회지:의학물리
    • /
    • 제18권3호
    • /
    • pp.107-117
    • /
    • 2007
  • 방사선 방호의 측면에서 기능강화동적쐐기가 금속쐐기에 비하여 가지는 이점을 평가하기 위하여 각각의 쐐기에서 산란되는 조사야 주변부 선량을 측정하였다. 측정 장비는 2D Array를 사용하였고 장비의 신뢰성을 검증하기 위하여 측정값과 치료계획장치에서 계산된 결과를 비교하였다. $15^{\circ},\;30^{\circ},\;45^{\circ},\;60^{\circ}$의 금속쐐기와 기능강화동적쐐기를 사용하였을 때에 선원표면간거리를 80 cm에서 90 cm로 변화시키며 조사야 주변부의 선량백분율을 측정하였다. 광자선의 에너지는 6 MV와 15 MV를 사용하였다. 측정은 0.5 cm 깊이에서 조사야 경계로부터 1 cm부터 5 cm까지 1 cm 간격으로 이루어졌다. 열형광선량계를 사용하여 절대 선량을 측정하였다. 2D Array를 사용하여 측정하였을 경우, 기능강화동적쐐기를 사용하였을 때의 조사야 주변부 선량백분율($1.4%{\sim}11.9%$)이 금속쐐기를 사용하였을 때($2.5%{\sim}12.4%$)에 비하여 낮았다. 15 MV의 에너지를 사용했을 경우에 6 MV의 에너지를 사용했을 경우보다 조사야 주변부 평균 선량백분율이 2.9% 높았다. 선원표면간거리가 80 cm일 경우에 90 cm일 경우보다 선량백분율의 차이를 분명히 확인할 수 있었다. 쐐기의 Heel 방향의 선량백분율이 Toe방향의 선량백분율보다 평균적으로 0.9% 낮았다. 열형광선량계를 이용한 절대 선량 측정에서도 2D Array를 사용하여 측정한 경우와 합치하는 결과가 나왔다. 기능강화동적쐐기는 임상에서 조사야 주변부의 정상조직에 불필요하게 산란되어 전달되는 선량을 감소시켜준다. 이러한 이점은 쐐기의 각도가 증가하고 선원표면간거리가 감소할수록 더욱 부각된다.

  • PDF

다엽 콜리메이터(Multileaf Collimator)와 합금납 차폐물(Lead Alloy Block)의 반 그림자영역의 선량 분포상의 특성 비교 (Dosimetric Characteristics on Penumbra Regions of the Multileaf Collimator as Compared with the Lead Alloy Block)

  • 이상욱;오영택;김우철;금기창;윤성익;김현수;박원;추성실;김귀언
    • Radiation Oncology Journal
    • /
    • 제13권4호
    • /
    • pp.391-396
    • /
    • 1995
  • 목적 : 컴퓨터의 발달에 힘입어 3-D Conformal Radiotherapy(3-D CRT)가 가능하게 되었고 3-D CRT를 위해서는 다엽콜리메이터(MLC)가 필수적인 장치이다. 이에 본 저자들은 MLC 사용시 반그림자(Penumbra)의 크기와 그 특성을 알아보고 기존의 합금납(lead alloy block)을 사용할 때의 반그림자와 차이를 비교 분석하여 임상에서 다엽콜리메이터(MLC)의 이용에 도움이 되고자 본 연구를 계획하였다. 방법 : MLC와 합금납의 반그림자를 측정하기 위해 6MV 와 10MV 에너지의 방사선을 이용하여 필름선량분석을 시행하였다. 필름에 각에너지의 dmax와 10cm 두께의 폴리스탈린 판톰을 올려 놓고 측정하였고, MLC의 종단면과 조사면의 y축과 이루는 각도를 변화시키면서 Effective penumbra($20{\%}-80{\%}$)와 $10{\%}-90{\%}$ 반그림자를 측정하였다. 결과 : MLC의 각도가 0o에서 75o로 증가함에 따라 반그림자의 크기가 증가 하였고, 반그림자 영역에서 등선량곡선의 부채살모양이 심화 되었다. dmax에서 보다 10cm 깊이에서 반그림자의 크기가 약간 증가하였고, 에너지가 증가 하면서 약간 반그림자가 커지는 경향성만 보였다. 합금납을 사용할 경우의 반그림자보다 MLC를 사용할경우 최대 4.8mm가 더 크게 측정되었다. 결론 : 3-D CRT를 시행함에 있어서 반그림자 영역에서는 기존의 합금납 차폐물을 대신하여 MLC를 사용하여도 무방하리라는 결론을 얻을 수 있었다.

  • PDF

유방암 방사선치료에 있어 치료도중 및 분할치료 간 위치오차에 대한 전자포탈영상의 컴퓨터를 이용한 자동 분석 (Computer Assisted EPID Analysis of Breast Intrafractional and Interfractional Positioning Error)

  • ;;;;진호상;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제17권1호
    • /
    • pp.24-31
    • /
    • 2006
  • 유방암 환자의 방사선치료에 있어 치료도중(intrafractional) 및 분할 치료 간(intefractional)에 발생되는 오차를 측정하는 자동분석소프트웨어를 개발하였다. 오차 분석 결과는 3차원 입체조형 방사선치료를 임상에 적용하기에 앞서 적절한 치료계획용적(Planning Target Volume, PTV)을 설정하는 데 있어 매우 중요하다. 본 연구에서는 전자포탈영상장치(Electrical Portal imaging Device, EPID)로써 Portal Vision LC250 액체 충전형 이온화 검출기를 사용하였다(fast frame-averaging 모드, 초당 1.4 프레임, 256X256 픽셀). 12명의 환자에 대해 최소 7일 이상씩 영상을 획득하였다. 매 치료마다 평균 8 내지 9개의 영상을 각 빔에 대해 얻었다(분당 400 MU 선량률). 총 2,931 (720 측정을 포함하는)개의 영상을 정량적으로 분석할 수 있는 자동화 영상 분석 소프트웨어를 개발하였다. 이를 통해 호흡으로 인해 발생하는 치료도중 오차와 분할 치료간 발생하는 분할치료오차의 표준편차($\sigma$)들을 계산하였다. 신뢰 구간 95%로 임상표적체적(Clinical Target Volume, CTV)을 포함할 수 있는 PTV 마진은 $2\;(1.96\;{\sigma})$으로 계산되었다. 주로 호흡으로 인해 유발되는 치료도중오차를 보상하기 위해 필요한 PTV 마진은 2 mm에서 4 mm이었다. 반면에 분할 치료간 오차를 보상하기위해 필요한 PTV 마진은 7 mm에서 31 mm이었다. 12명의 환자에 대한 전체 평균오차는 17 mm이었다. 분할치료 간 오차는 호흡에 의해 유발되는 치료도중 오차에 비해 2배에서 15배까지 더 크게 나타났다. 유방암 치료에 있어 3차원 입체정형조사나 세기조절방사선치료(Intensity Modulated Radiation Therapy, IMRT)를 적용하기에 앞서 반드시 셋업 오차의 크기를 측정하여 PTV에 적절히 반영되어야 한다. 유방에 대한 3차원 입체정형조사나 세기조절방사선치료를 위해 반드시 필요한 것은 아니지만, 큰 PTV 마진을 줄여주기 위해서는 영상유도방사선치료(Image Guided Radiation Therapy, IGRT)가 매우 유용하게 이용될 수 있다. 전자포탈영상장치 들은 본 보고서에서 기술한 바와 같은 자동분석소프트웨어를 반드시 포함하여야 한다. 이를 통해 수많은 EPID 영상들을 자동화 처리하고 오차분석을 시행함으로써 각 병원의 임상적용 방법 및 환경에 따라 상이하게 나타날 수 있는 오차의 크기를 감안한 적절한 PTV마진을 구하는데 도움을 얻을 수 있다. 이러한 장치들은 또한 최소의 노력으로 환자 치료를 관찰할 수 있는 귀중한 정보를 제공해 준다.

  • PDF

임산부의 방사선치료 시 태아선량 평가 (Estimation of Fetal Dose during Radiation Therapy of Pregnant Patient)

  • 정치훈;김찬용;김보겸;서석진;유숙현;박흥득
    • 대한방사선치료학회지
    • /
    • 제19권1호
    • /
    • pp.35-41
    • /
    • 2007
  • 목 적: 임산부의 방사선치료시 태아에 조사되는 선량을 알아보고, 임상에 적용가능한 간단한 차폐방법을 적용하여 태아선량이 감소되는 정도를 평가하고자 한다. 대상 및 방법: 본원에 내원한 임신 24주째인 뇌전이 환자를 대상으로 전뇌 방사선치료를 시행하는 동안 태아에 조사되는 선량을 인체 팬톰(Anderson Rando Phantom, Alderson Research Laboratories Inc., USA)을 사용하여 평가하였다. 환자에 대한 치료처방은 일일선량 300 cGy, 10회, 총선량 3000 cGy, 그리고 치료조건은 에너지 6 MV, 조사야크기 $18{\times}22cm^2$이었다. 선량평가는 환자 치료조건과 동일한 상태로 조사야 하단에서 각각 30, 40, 50, 60 cm에서 전리함((TN30013, 0.6 cc Farmer type chamber, PTW Unidos, Germany)을 사용하여 측정하였고, 다음은 환자치료조건과 동일하지만 본원에서 고안한 추가 차폐방법(shielding wall, neck supporter, Pb sheets, acrylic bridge)을 이용하여 태아를 차폐한 다음 위의 측정점과 동일한 위치에서 측정하여 그 차폐효과를 비교 평가 하였다. 또한 추가 차폐한 상태에서 열형광선량계(4000, Harshaw, Solon Technologies Inc., USA)를 사용하여 30, 40, 50, 60, 70 cm 지점에서 측정하여 전리함 측정값과 비교 분석하였다. 결 과: 전리함을 이용하여 측정한 결과 환자가 총선량 3,000 cGy를 받는 동안 태아에 조사될 수 있는 선량은, 추가 차폐가 없는 경우 조사야 하단 30, 40, 50, 60 cm에서 각각 3.20, 3.21, 1.44, 0.90 cGy, 추가 차폐가 있는 경우 0.88, 0.60, 0.35, 0.25 cGy로 추가 차폐를 하였을 경우 하지 않았을 경우보다 약 $70{\sim}80%$의 차폐효과를 얻을 수 있었다. 그리고 열형광선량계 측정결과는 1.8, 1.2, 0.8, 1.2, 0.8 (70 cm) cGy로 나타났다. 이로서 태아가 전 치료 과정중 받을 수 있는 총선량은 1 cGy 이하로 측정되었다. 결 론: 임산부의 방사선치료가 필수적으로 요구될 경우 고려되어야 할 가장 중요한 인자는 태아선량의 최소화가 될 것이다. 방사선장애의 역치선량이 $10{\sim}20cGy$인 것을 감안하면 상기 방법에 의한 임산부의 방사선치료는 이러한 목적에 부합될 뿐만 아니라 사용방법 또한 비교적 용이하다고 생각된다.

  • PDF