• Title/Summary/Keyword: Edentulous, Follow-up

Search Result 66, Processing Time 0.03 seconds

A STUDY OF CLINICAL RESULTS ON STERI-OSS ENDOSSEOUS IMPLANTS (Steri-Oss 임플랜트의 임상 결과에 관한 연구)

  • Min, Young-Kyu;Kweon, Hyeog-Sin;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.258-272
    • /
    • 1998
  • This investigation evaluated patients who received Steri-Oss implants from the Dental Hospital of Chosun University during the period from March 1989 to August 1997. 346 fixtures of 127 patients were included in this study. The results were as follows ; 1.The follow-up period was defined as the period between the surgical placement of the implants and the last follow-up examination. The mean follow-up period was $2.17{\pm}1.21$ years. 2.The period between fixture installation and second surgery was $0.71{\pm}0.44$ years in the maxilla and $0.46{\pm}0.21$ years in the mandible. 3.The number of fixtures which were installed in the upper jaw(112) was less than that in the lower jaw(234) and in the posterior region(260) was more than in the anterior region(86). 4.The length of fixture which was most frequently used was 12 mm and least was 8mm. Screw implants were installed more than cylindrical implants. 3.8mm implant was the most common implans, followed by 4.5mm and 3.25mm. 5.The number of augmentation cases was more than that of non-augmentation cases and the rate of augmentation cases in the maxilla was more than that in the mandible. 6.Implant restorations for partial edentulos patients(94cases) were more than single- tooth implant restorations(33cases) or implant restorations for complete edentulos patients(10cases). 7.Free-standing prostheses for partially edentulous patients were more commom than any other type of connection between implants and natural teeth. 8.Plaque Index($0.95{\pm}0.74$) and Gingival Index($0.31{\pm}0.52$) were very similar around the natural teeth and reflected an acceptable level of plaque and gingivitis control. Mean value for keratinized mucosa index($1.93{\pm}1.20$) remained fairly constant around level 2(1-2 mm keratinized epithelium). 9.Patients were generally satisfied with implant in terms of comfort, function, speech and esthetics. 10.There was not a statistically significant differences in overall survial rate between implants placed in the maxilla (91.5%) and those placed in the mandible (93.8%). Fourteen implants lost before the prosthetic rehabilitation and eleven implants lost following variable periods in function after the prosthetic phase of the treatment. 11.Cause of implant failures was exfoliation or removal of fixture due to non-osseointegration before the prosthetic rehabilitation or due to fracture of fixture, masticatory pain after the prosthetic rehabilitation. 12.The survival rate of Steri-Oss implants using the Kaplan-Meier statistical analysis was 93.8% at 2 year and 86.6% at 5 year, In all cases, implant losses occured predominantly in the healing period. There was a steep decline in the rate of implant loss after the first year. 13.The survival rate of Steri-Oss implants in the anterior region was 94.8% at 2 year and 94.8% at 5 year and that in the posterior region was 92.8% at 2 year and 75.9% at 5 year. In conclusion, this study revealed a number of parameters and guidelines for achieving an optimal success rate in osseointegration.

  • PDF

Long-term effect of implant-abutment connection type on marginal bone loss and survival of dental implants

  • Young-Min Kim;Jong-Bin Lee;Heung-Sik Um;Beom-Seok Chang;Jae-Kwan Lee
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.6
    • /
    • pp.496-508
    • /
    • 2022
  • Purpose: This study aimed to compare the long-term survival rate and peri-implant marginal bone loss between different types of dental implant-abutment connections. Methods: Implants with external or internal abutment connections, which were fitted at Gangneung-Wonju National University Dental Hospital from November 2011 to December 2015 and followed up for >5 years, were retrospectively investigated. Cumulative survival rates were evaluated for >5 years, and peri-implant marginal bone loss was evaluated at 1- and 5-year follow-up examinations after functional loading. Results: The 8-year cumulative survival rates were 93.3% and 90.7% in the external and internal connection types, respectively (P=0.353). The mean values of marginal bone loss were 1.23 mm (external) and 0.72 mm (internal) (P<0.001) after 1 year of loading, and 1.20 mm and 1.00 mm for external and internal abutment connections, respectively (P=0.137) after 5 years. Implant length (longer, P=0.018), smoking status (heavy, P=0.001), and prosthetic type (bridge, P=0.004) were associated with significantly greater marginal bone loss, and the use of screw-cement-retained prosthesis was significantly associated (P=0.027) with less marginal bone loss. Conclusions: There was no significant difference in the cumulative survival rate between implants with external and internal abutment connections. After 1 year of loading, marginal bone loss was greater around the implants with an external abutment connection. However, no significant difference between the external and internal connection groups was found after 5 years. Both types of abutment connections are viable treatment options for the reconstruction of partially edentulous ridges.

Implant assisted removable partial denture with implant surveyed crown: A 20-month follow-up case report (단일 임플란트 서베이드 크라운을 이용한 하악 임플란트 융합 국소의치: 20 개월 경과 관찰 증례 보고)

  • Roh, Kyoung-Woo;Jeon, Young-Chan;Jeong, Chang-Mo;Yoon, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.323-329
    • /
    • 2018
  • Traditional options for posterior edentulous treatment include removable partial dentures and implant fixed prostheses. Recently, the concept of implant assisted removable partial denture, in which two treatments are fused, has been introduced in consideration of systemic health and patient's needs, costs, residual alveolar bone status and so on. Implant assisted removable partial denture has the advantage of increasing the retention and stability of the denture and improving its esthetics in cases of large bone defects or biomechanical disadvantages. In addition, it is possible to strategically place the implants in a site where the alveolar bone is relatively sufficient, thereby overcome the limit of the conventional removable partial denture design as well as reducing the burden on a wide range of implant surgery. Cost reduction is also expected. In this case, the patient was treated by placing the implant in both premolar sites of the mandible and fabricating the distal extension removable partial denture with the implant fixed prosthesis as an abutment. After delivering the definitive prosthesis, the patient showed satisfaction with the masticatory function and esthetics. and has been regularly followed-up for more than one year. The following 20-months follow-up case report describes the design of an implant-assisted-removable partial denture (IARPD) in which two cementretained implant crowns used to provide support and stability.

Prosthetic rehabilitation by obturator considering the biomechanics in partially edentulous patient after maxillectomy (상악골 절제술을 받은 부분 무치악 환자에서 생역학을 고려해 제작한 구개 폐색장치를 이용한 보철 수복 증례)

  • Lee, Kang-Shin;Park, Ju-Mi;Ahn, Seung-Geun;Seo, Jae-Min;Park, Yeon-Hee;Lee, Jung-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.4
    • /
    • pp.281-293
    • /
    • 2021
  • Patients who went through maxillectomy can have severely impaired swallowing, mastication, and pronunciation functions because of palatal defects. Leakage occurs through the nasal cavity while eating, chewing becomes difficult due to the loss of teeth and alveolar ridges, and oral and nasal passages are not separated, leading to hyper-nasal sound, and significantly reducing the quality of life. To prosthetically reconstruct the defect, the weight of the obturator should be reduced as much as possible to minimize dropout because of gravity, and the bulb of the obturator should be properly extended into the defect to get additional retention and stability. In this case of a partially edentulous patient who underwent additional maxillary resection because of tumor recurrence, a metal framework was designed by applying the basic design principles of removable partial dentures. An obturator with improved retention, stability, and support was fabricated through functional impressions. The patient was satisfied with the improved facial expression, mastication, swallowing, and pronunciation, and showed stable occlusion and oral hygiene management during the follow-up period.

Retrospective Study of Sandblasted, Large-grit and Acid-etched Implant (Sandblasted, Large-grit and Acid-etched Implant에 대한 후향적 임상 연구)

  • Jo, Ji-Ho;Kim, Su-Gwan;Moon, Seong-Yong;Oh, Ji-Su;Park, Jin-Ju;Jung, Jong-Won;Yoon, Dae-Woong;Yang, Seong-Su;Jeong, Mi-Ae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.4
    • /
    • pp.352-358
    • /
    • 2011
  • Purpose: This study evaluated the prognosis and survival rate of SLA (Sandblasted, Large-grit and Acid-etched) implants and it also evaluated the prosthodontic complications and the associated factors. Methods: Twenty seven patients (14 men and 13 women, mean age: 54.9) who visited Chosun University Hospital Implant Center with the chief desire for placement of an implant in an edentulous area from March, 2008 to December 2008 and who received placement of a SLA implant ($Implantium^{(R)}$, Dentium Co., Korea) were selected for this study. Results: The average follow-up period was 15 months and the study was based on the treatment records, radiographs and clinical examinations. A total of 69 implant cases were retrospectively assessed for the width and length of the implant, the primary and secondary stability, the combined surgery, the employed bone graft material and barrier membrane, the status of the opposing tooth, implant failure and the prosthetic complications. During the follow-up period (average: 15 months), the accumulative survival rate of the 69 implants in 27 patients was 100%. Complications such as infection, sinusitis and fixture exposure after surgery were seen for 5 implants in 4 patients. Complications such as screw loosening, contact loosening and peri-implant gingivitis after prosthodontic treatment occurred in 7 cases (10.14%). Conclusion: This study reports placement of SLA implants may cause various complications, yet the final accumulative survival rate was 100%. The SLA implant ($Implantium^{(R)}$) has an excellent clinical survival rate and outcome.

PIEZOELECTRIC VERTICAL BONE AUGMENTATION USING SANDWICH TECHNIQUE IN ATROPHIC MANDIBLE: TWO CASES REPORT (Sandwich technique을 이용한 하악골 증대술의 치험 보고)

  • Lee, Ji-Soo;Lee, Jung-Kwang;Lee, Hyun-Jin;Ahn, Mi-Ra;Sohn, Dong-Seok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.3
    • /
    • pp.276-282
    • /
    • 2008
  • Objective: This is to report the efficacy of the sandwich technique for bone augmentation in a moderate atrophic posterior mandible through clinical and histological results in two cases. Subjects and Method: Two patients selected had moderate bone resorption in left lower edentulous area. Sandwich osteotomy using the piezosurgery was performed and the osteomized alveolar segments were elevated by 6mm in each two patients. The interpositional mineral allograft materials were inserted in the atrophic posterior mandibles. After four months healing period, bone biopsies in the grafted areas and placement of dental implants were performed. In both cases, panoramic views were taken preoperatively to measure the alveolar bone height for diagnosis, to monitor patient healing, and to evaluate bone healing and bone gain. Results: Sufficient vertical bone height was gained by using the sandwich technique and implants were placed successfully. In radiological evaluation, there was minimal resorption of bone height after the second operation and in histomorphometric evaluation, they showed favorable new bone formation without inflammation in the grafted areas. Conclusion: The sandwich technique can be an effective choice for augmenting vertical bone height in the atrophic mandible. More of cases and long term follow-up are needed to evaluate bone resorption and implant prognosis.

Implant Fixture Installation in the Posterior Maxilla Using a Tooth-supported Surgical Template Based on Computer Assisted Treatment Planning (컴퓨터 보조 기반 치아 지지 서지컬 템프레이트를 이용한 상악구치부 임플란트 식립)

  • Kim, Soung Min;Kim, Myung Joo;Lee, Jee Ho;Myoung, Hoon;Lee, Jong Ho;Kim, Myung Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.6
    • /
    • pp.381-389
    • /
    • 2013
  • Two patients with partial edentulous maxilla were scheduled to undergo installation of implant fixtures using a tooth-supported surgical template based on computer assisted treatment planning. After 3-dimensional (3D) computed tomographic scanning was transferred to the OnDemand3D (Cybermed Co., Seoul, Korea) software program for virtual planning, fixtures of MK III Groovy RP implant of the Br${\aa}$nemark System (Nobel Biocare AB Co., G$\ddot{o}$teborg, Sweden) was installed using the In2Guide (CyberMed Co., Seoul, Korea) tooth-supported surgical template with a Quick Guide Kit (Osstem Implant Co., Seoul, Korea) system in the posterior maxilla of each patient. Sinus floor elevation with a xenogenic bone graft procedure was also performed simultaneously in one patient. Fixture installations were completed successfully without complications, such as sinus mucosa perforation, bony bleedings, fenestrations, or others. During the last two-year follow-up period after prosthetics delivery, each implant was found to be fine with no other minor complications. The entire procedures are reported and the literatures on use of tooth-supported surgical template was reviewed.

MAXILLARY SINUS BONE GRAFT USING PARTICULATED RAMAL AUTOBONE AND BOVINE BONE (하악지 분쇄자가골과 이종골을 이용한 상악동 골이식술)

  • Kim, Kyoung-Won;Lee, Eun-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.3
    • /
    • pp.254-261
    • /
    • 2009
  • The maxillary sinus bone graft procedure is one of the predictable and successful treatments for the rehabilitation of atrophic and pneumatized edentulous posterior maxilla. Materials used for maxillary sinus floor augmentation include autogenous bone, allogenic bone, xenogenic bone and alloplastic materials. Among them, autogenous bone grafts still represents 'gold standard'for bone augmentation procedures. We selected the mandibular ramus area as a donor site for the autogenous bone graft because of low donor site morbidity. We performed maxillary sinus bone graft procedures with implant placement using particulated ramal autobone and bovine bone mixture, and got good results. This is a preliminary report of the maxillary sinus bone graft using particulated ramal autobone and bovine bone, requires more long-term follow up and further studies.

Hybrid telescopic double crown denture on maxillary few remaining teeth and 2 mandibular implants in case of failed implant overdenture (상악의 소수 잔존치와 실패한 하악의 임플란트 오버덴처의 재수복 임상증례: 프릭션핀을 이용한 하이브리드 텔레스코픽 이중관법)

  • Ha, Seok-Joon;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.246-252
    • /
    • 2016
  • Double crown prostheses can be used in patients who have a few remaining teeth and poor periodontal condition because of secondary splinting of abutments, vertical loading, decrease of the length of lever arm due to fulcrum line located on margin of inner and outer crown. Successful results of treatments using double crown prostheses for the partially edentulous patients who have a few remaining teeth and implant overdenture using a small number of implants have been reported. In this case, there were a few remaining teeth with a very poor periodontal condition in maxilla, and there were a failed implant with severe alveolar bone resorption and shrinkage in the mandible. The main objective of this report is to introduce our case because a double crown partial denture showed satisfactory results in functional and esthetical aspects during more than one-year follow-up period.

Causes of failures of long-term used double crown denture and new rehabilitation with dental implant and tooth combined denture using remaining teeth and implants (장기간 사용한 이중관 의치의 실패원인 및 자연치와 임플란트를 이용한 이중관 의치 수복증례)

  • Seo, Jeong-Gyo;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.384-390
    • /
    • 2018
  • Hybrid telescopic double crown have ever been good treatment option for patient with periodontally unfavorable few remaining teeth for successful prognosis. Tooth and implant combined telescopic double crown can be used for improving retention and support for denture with strategically placed implants on edentulous ridge. In this case, an 55-year-old female patient had chronic periodontitis with few remaining teeth on maxilla and fixed partial prosthodontics on mandible. Treatment of hybrid telescopic double crown with friction pin lasted 9.5 years only with natural teeth. After 9.5 years, additional implants was installed due to fracture of cast-posted abutment teeth. After implantation, tooth and implant combined double crown had fabricated. Through re-treatment, no complications of new denture has been found during 2 years follow up. This case presents fair prognosis of tooth and implant combined double crown denture in periodontally unfavorable condition.