• Title/Summary/Keyword: Eddy current loss

Search Result 218, Processing Time 0.027 seconds

Water-Side Oxide Layer Thickness Measurement of the Irradiated PWR Fuel Rod by NDT Method

  • Park, Kwang-June;Park, Yoon-Kyu;Kim, Eun-Ka
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.680-686
    • /
    • 1995
  • It has been known that water-side corrosion of fuel rods in nuclear reactor is accompanied with the loss of metallic wall thickness and pickup of hydrogen. This corrosion is one of the important limiting factors ill the operating life of fuel rods. In connection with the fuel cladding corrosion, a device to measure the water-side oxide layer thickness by means of the eddy-current method without destructing the fuel rod was developed by KAERI. The device was installed on the multi-function testing bench in the nondestructive test hot-cell and its calibration was carried out successfully for the standard rod attached with plastic thin films whose thicknesses are predetermined. It shows good precision within about 10% error. And a PWR fuel rod, one of the J-44 assembly discharged from Kori nuclear power plant Unit-2, has been selected for oxide layer thickness measurements. With the result of data analysis, it appeared that the oxide layer thicknesses of Zircaloy cladding vary with the length of the fuel rod, and their thicknesses were compared with those of the destructive test results to confirm the real thicknesses.

  • PDF

Properties of Fe-based Soft magnetic Thin Film with Hybrid Structures (Hybrid 구조의 Fe계 연자성 박막의 특성)

  • 송재성;이원재;허정섭;김현식;오영우
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.11
    • /
    • pp.963-968
    • /
    • 2000
  • Magnetic properties and microstructures of Fe$\_$93-x/Zr$_3$B$_4$Ag$\_$x/ thin films were investigated as a function of addition of element Ag, (X$\_$Ag/=0 to 6 at.%) and annealing temperature, T$\_$a/=300$\^{C}$ to 600$\^{C}$. In the case of adding Ag, magnetic properties of Fe$\_$93-x/Zr$_3$B$_4$Ag$\_$x/ thin films were improved than those of Ag-free Fe$\_$93/Zr$_3$B$_4$thin films. The prominent soft magnetic properties with coercivity of 1.1 Oe, saturation magnetization of 2.2 T and permeability of 5400 at 50㎒ were obtained from Fe$\_$88/Zr$_3$B$_4$Ag$\_$5/ thin film annealed was lower than that of Fe-base or Co-base thin films reported previously. Such enhanced magnetic properties are presumably attributed to the format in ultra fine grains. Also, the reduced eddy current loss in the annealed sample is due to refined micro magnetic domains with increasing the amount of Ag in Fe$\_$93-x/Zr$_3$B$_4$Ag$\_$x/ thin films.

  • PDF

Analysis of Eddy Current Loss in the Bobbin Type Cooling Plate for Winding (권선 보빈형 열전도판의 와전류 손실 해석)

  • Park, Myung-Jin;Kwak, Sang-Yeop;Lee, Sang-Yeop;Kim, Woo-Seok;Lee, Ji-Kwang;Choi, Kyeong-Dal;Bae, Joon-Han;Kim, Seok-Ho;Sim, Ki-Duk;Seong, Ki-Chul;Jung, Hyun-Kyo;Hahn, Song-Yop
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.144-145
    • /
    • 2007
  • SMES의 운전 상태는 충전, 운전, 방전의 3가지 모드로 나눌 수 있으며, 충 방전 구간에서 와전류 손실이 발생한다. SMES의 에너지 방전 시 마그넷에서의 전류 감소로 인한 와전류 손실은 비록 짧은 시간동안 발생하지만 그 크기가 냉동기의 정격 열 부하 용량에 비해 상대적으로 크기 때문에, SMES 시스템 설계 시 이에 대한 영향을 고려해야 한다. 본 논문은 고온초전도 선재를 이용하여 개발 중인 600 kJ SMES의 방전 시, 마그넷을 냉각시키기 위한 권선 보빈형 열전도판의 분할과 슬릿의 위치에 따른 와전류 손실 변화를 3차원 유한요소법을 이용해 해석하고 그 결과를 제시하였다.

  • PDF

Microstructure and Mgnetic Properties of Electrodeposited Nanocrystalline Low-Nickel Permalloy (전착법으로 제조한 나노결정질 저Ni 퍼멀로이의 미세 조직과 자기적 특성)

  • 허영두;이흥렬;황태진;임태홍
    • Journal of the Korean institute of surface engineering
    • /
    • v.36 no.6
    • /
    • pp.455-460
    • /
    • 2003
  • Microstructural and magnetic properties of nanocrystalline Fe-46 wt%Ni and Fe-36 wt%Ni alloys were investigated. Alloys were prepared by the electrodeposition process. The electrolytes were iron sulfate/nickel chloride-based and iron chloride/nickel sulfamate-based solutions. Fe-46 wt%Ni alloy was FCC structure with grain size of 10 nm, but FCC and BCC phases were found in Fe-36 wt%Ni alloy and its grain size was smaller. Effective permeability of Fe-36 wt%Ni alloy was higher than that of Fe-46 wt%Ni alloy in the high frequency range because of large electrical resistivity and small eddy current loss resulted from grain size decrease. Up to $300^{\circ}C$ of annealing temperature, grain growth of Fe-Ni alloys slowly occured. Conversely, annealing above $450^{\circ}C$ led to a drastic grain growth. In that case, effective permeability was decreased at the temperature lower than $300^{\circ}C$ but at $300^{\circ}C$ or higher effective permeability was increased. At the high frequency of 1 MHz, electrodeposited Fe-Ni alloys had higher effective permeability with an decrease in the grain size.

A Study on the Magnetic Properties of Mn-Zn ferrite added on $V_2O_5$ and $CaCo_3$ ($V_2O_5$$CaCo_3$를 첨가한 Mn-Zn Ferrite의 자기적 특성에 관한 연구)

  • 권오흥
    • Resources Recycling
    • /
    • v.11 no.5
    • /
    • pp.30-33
    • /
    • 2002
  • Recently in the progress of electronic equipment, power transformer was considered an important part. To make power transformer with miniaturization, lightening, low Power, we need a high efficiency core material. In this paper, we added $V_2$$O_{5}$ and $CaCo_3$ to Mn-Zn Ferrite to make a high efficiency, low loss core material. The compositions are MnO : ZnO : $Fe_2$$O_3$=37 : 11 : 52 mol%. They were sintered at 1250 for Three hours. Initial permeability was measured at 0.1 MHz. At 200 mT, Power loss was measured by temperature changing at 25 KHz, 50 KHz, 100 KHz. When we added $V_2$$O_{5}$ and $CaCo_3$, 0.08 wt%, 0.05 wt% respectively, we get 415 ㎾/㎥ at 200 mT, 100 KHz, $60^{\circ}C$. We can reduce eddy current loss as a main loss of high frequency by addition of a little mount of $V_2$$O_{5}$ $CaCo_3$. So we can decrease the power transformer's power loss.

Effects of Annealing on Electromagnetic Wave Absorption Characteristics in FeSiCr Flakes/Polymer Composite Sheets (FeSiCr 박편/폴리머 복합 시트의 전자파 흡수 특성에 미치는 합금 어닐링 효과)

  • Kim, Ju-Beom;Noh, Tae-Hwan
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.3
    • /
    • pp.83-88
    • /
    • 2013
  • The soft magnetic Fe-Si-Cr flakes with the thickness of about 1 ${\mu}m$ were annealed at 500 and $700^{\circ}C$ for 1 h, and the composite sheets for electromagnetic wave noise absorber available for quasi-microwave band were fabricated by using these annealed flakes and polymer. Further the power loss characteristics of the composite sheets was investigated to clarify the annealing effect on electromagnetic wave absorption properties. The power loss decreased in the frequency range of several GHz when the annealed flakes were used as compared to the sheet using the as-milled FeSiCr alloy flakes. Moreover the sheets using annealed flakes exhibited lower value of real and imaginary part of complex permeability. These inferior electromagnetic wave absorption properties of the composite sheets using annealed alloy flakes were considered to be obtained by the enhanced eddy current effect upon annealing-induced recovery of microstructure and resulted low complex permeability.

An Application of Solenoid Eddy Current Sensor for Nondestructively Inspecting Deterioration of Overhead Transmission Lines due to Forest Fires (산불에 의한 가공송전선의 열화특성을 비파괴적으로 검출하기 위한 솔레노이드 와류센서의 응용)

  • Kim, Sung-Duck;Kim, Young-Dal;Jeong, Dong-Hwa
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.6
    • /
    • pp.404-415
    • /
    • 2000
  • This paper describes several performances and nondestructive inspection for deterioration due to forest fires in overhead transmission lines. After discussing corrosion mechanism such as atmospheric and galvanic corrosion for aged ACSR conductors and its detection for them are presented. Through impedance analysis of a solenoid coil, it is shown that the eddy current sensor may be available to inspect severe fault or local corrosion. As the solenoid coil changes its impedance when the test conductor is inserted into the coil, it can be possible to measure deterioration degree caused by forest fires. Tensile strength, extension rate and sensor impedance are tested for some samples degraded by artificial fire. As increasing blazed period to some extent, the strength of aluminum strand begins to be reduced remarkably, while galvanized steel strand holds the similar strength to the initial value, despite of appearing a little loss of zinc layer. In general, it is shown that the sensor impedance would be increased while the tension load of conductor is reduced and the extension rate is contrarily increased. Therefore, the sensor output could exhibit the changes of mechanical performances, and would be used to detect such deterioration caused by forest fire in ACSR conductors built on the ridge of mountains. Finally, it was verified that the solenoid coil could be applicable to obtain any crucial inform for serious deterioration due to forest fires.

  • PDF

Magnetic Properties of NixFe100-x(x=40~50) Permalloy Powders and Dust Cores Prepared by Gas-Atomization (가스 분무법으로 제조된 NixFe100-x(x=40~50) 퍼멀로이 분말 및 압분 코아의 자기적 특성)

  • Noh, T.H.;Kim, G.H.;Choi, G.B.;Kim, K.Y.
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.6
    • /
    • pp.218-223
    • /
    • 2002
  • We investigated the magnetic properties of High Flux-type $Ni_{x}Fe_{100-x}$(x=40∼50, wt.%) permalloy powders and dust cores. The powder was prepared by conventional gas atomization in mass production scale. At the composition of $Ni_{x}Fe_{55}$, saturation magnetization was maximum. In case of lower Ni content than X=45, the $M_{s}$, decreased largely with the decrease in Ni content, which is due to the invar effect. The permeability of compressed powder cores increased with the decrease in Ni content, which was considered to be due to the decrease in the magnetostriction. In addition, the dust core with Ni=45% showed the lowest core loss because of the increase in electrical resistivity leading to the low eddy current loss. From the better frequency dependence of permeability, larger Q value and superior DC bias characteristics of Ni=45% than those of Ni=50% core, it was confirmed that the 45%Ni-55%Fe powder alloy was better material for the dust core than commercial High Flux core materials.

Relation of Grain Size with Magnetic Domain Wall for Tertiary Recrystallized 3% Si-Fe Strip (3차 재결정에 의한 극박 방향성 규소강판의 결정립 크기와 자벽수와의 관계)

  • ;K. I. Arai
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.3
    • /
    • pp.165-169
    • /
    • 1996
  • The relationship between grain size and number of magnetic domain walls for tertiary recrystallized ultra thin 3 % Si-Fe strips was investigated. It was found that the strips with different grain size can be produced by controlling the inserting speed of sample in annealing furnace. Though grain size of the stirip became smaller than 1mm, $B_{8}$ of high value above 1.95T was obtained. But $H_{c}$ increased with decaying the grain size. The magnetic domains and losses of the ultra thin grain oriented silicon steel with smaller grian size were observed. The eddy current losses of the strips were decreased with decreasing the grain size in high frequency range because strips with smaller grain have narrower magnetic domain wall spacings. But Hysteresis losses of the strips with smaller grain have high value in low frequency range. Therefore the iron loss of ultra thin grain oriented silicon steel could be controlled by the grain size. It was clarified that the minumum tatal loses depended on the exciting frequency and grain size.

  • PDF

Analysis of Properties of Flake Sendust EM Wave Absorber according to Granularity (입도에 따른 Flake Sendust 전파 흡수체의 특성 분석)

  • Park, Soo-Hoon;Kim, Dong-Il;Choi, Dong-Han;Kim, Seong-Yeon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.9
    • /
    • pp.1051-1057
    • /
    • 2008
  • In this paper, we analyzed the characteristics of the EM wave absorber which was fabricated by using flake sendust (soft metal magnetic powder). The flake sendust was made of 3 different granularity by attrition mill. First, we have fabricated 3 kind of EM wave absorbers using the flake sendust and CPE(Chlorinated Polyethylene) and measured the S-parameters of the EM wave absorber. The complex relative permittivity and permeability were calculated from the measured data and the variations according to a change of granularity were researched. As a result, it was confirmed that the EM wave absorber using flake sendust with the $140{\mu}m$ average granularity has outstanding absorption ability in high frequency range(C band) for the reduction of eddy current loss(increase of permeability) and the increase of space charge polarization(increase of permittivity).