• Title/Summary/Keyword: Economical loss

Search Result 287, Processing Time 0.035 seconds

An Experimental Study on the Physical Properties of Foamed Concrete Using Bottom Ash (바텀 애쉬를 이용한 기포콘크리트의 물리적 특성에 관한 실험적 연구)

  • Kang Ki Woong;Kang Chul;Kwag Eun goo;Shin hong cheol;Kwon Ki Joo;Kim Jin Man
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.525-528
    • /
    • 2004
  • The annual consumption of coal by coal-fired power plants is increasing. Also a large amount of ash is produced. The disposal of this large amount of ash makes the serious environmental problems and economical loss. Fly ash among the ash produced is used in building industries as a substitute to cement in concrete. But bottom ash is not used because of its poor properties. This study is aimed at the production of foamed concrete using bottom ash, to examine the physical properties of foamed concrete is manufactured by autoc1aving, and to exhibit the fundamental data to use it in site.

  • PDF

Improvement of Apportioning Responsibility for the Time Extension in Construction Projects (건설공사 공기연장 책임구분의 문제점 및 개선방안 제시)

  • Kim, Jong-Han;Kim, Kyung-Rai
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.60-67
    • /
    • 2007
  • Cases of the time extension have continuously transpired in the public construction projects. The potential of economical loss and claims is increased because the concerned parties such as an owner or a contractor have not properly performed their own responsibility for the time extension. Therefore, this paper aimed to improvement of apportioning responsibility for the time extension in construction projects.

  • PDF

Optimal Maintenance Interval Decision For Minimum Cost (최소 비용을 위한 최적의 유지보수 주기 결정)

  • Kim, Hyung-Jun;Shin, Jun-Seok;Kim, Jin-O;Kim, Hyung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.742-743
    • /
    • 2007
  • A maintenance plan of power system equipment reduces failure rate caused by equipment's age. To prevent unexpected failure, the maintenance is performed periodically according to the interval time. The more expansive equipment's scale is, the more the maintenance without considering costs sustains a economical loss. Hence, the maintenance's time and the cost must be considered when maintenance which is considering the reliability is implemented. In this paper, optimum maintenance interval is calculated by considering minimum maintenance cost of the equipment with the combined cycle units in Korea power systems.

  • PDF

Analysis of administration system for lightning damage in developed countries (선진국의 낙뢰피해 관리운영체제 분석)

  • Cho, Sung-Chul;Lee, Tae-Hyung;Eom, Ju-Hong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.340-343
    • /
    • 2009
  • Recently, the lightning damage to human and structure is increasing steadily and many countries try to reduce lightning-caused casualties and economical loss through special disaster management system. The organization of warning system and management system for lightning damage in developed countries were investigated in this paper. The organization of central government for disaster management and cooperation system with local government in USA, Japan, the Britain, and Germany were introduced and the division of roles with meteorological administration were described.

  • PDF

Evaluate the expected price of HTS transformer for introducing into korean power system (초전도변압기의 계통적용을 위한 예상 시장진입가격 추정)

  • Kim, Jong-Yul;Lee, Seung-Ryul;Yoon, Jae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.176-178
    • /
    • 2004
  • HTS (High Temperature Superconducting) Transformer has the several useful characteristics in the viewpoints of technical and economical. Especially, an HTS transformer replaces the copper wire coils in a conventional transformer with lower loss HTS wire In addition, inexpensive, environmentally benign liquid nitrogen replaces the conventional oil as the electrical insulation (dielectric) and provides the necessary cooling for the HTS transformer Therefore, the Life-cycle cost of an HTS transformer is much more attractive than conventional because it is more energy efficient, lighter in weight, smaller in size, and environmentally compliant. HTS transformer can be the best way to replace with conventional transformer in the future. In this paper, we investigate the expected price of HTS transformer to have a merit in viewpoint of economic aspect. First, life-cycle cost of conventional transformer is calculated and based on this, the expected price of HTS transformer is evaluated, which HTS transformer is competitive against conventional transformer.

  • PDF

A Study on the Deterministic Evaluation Method of R&D Project in Food Industry (식품산업 연구개발의 결정론적 평가방법에 관한 연구)

  • 이종만;이근희
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.14 no.23
    • /
    • pp.57-64
    • /
    • 1991
  • The preliminary, advanced and final evaluation of R&D project is essential in order to reduce loss of resource and opportunity and to minimize uncertainty resulting from optimal selection and efficient progress of R&D project. This thesis examined characteristics of deterministic evaluation, economical evaluation, and OR-approach evaluation as theoretical methodology of evaluation of R&D project applicable to food industry in Korea by using scoring method, one of deterministic evaluations. In addition, this thesis divided the evaluation factors for preliminary evaluation of R&D project into 5 groups and 30 factors on basis of the environment of domestic companies and set up the standard of each evaluation factors and contains marking-selecting way. But, generally, the evaluation model by this thesis, as the conditions of the business company environment are different to each other, contents to be set up evaluation factors, evaluation standard and decision method conforming to each the environment of the business companies with referring to as one standard of evaluation project for selecting R&D project.

  • PDF

A Study on Microwave Self Oscillating Mixer Using Ga As MESFET (GaAs MESFET를 이용한 초고주파 자체발진 혼합기에 관한 연구)

  • Kwon, Dong Seung;Chae, Jong Seok;Park, Han Kyu
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.3
    • /
    • pp.413-419
    • /
    • 1987
  • In this paper, self-oscillating mixer is designed by small signal S-parameter and series feedback circuit. The input-output matching circuit is accomplished from double stub and additional matching stub. The self-oscillating mixer is oscillating itself and amplifies without any external local oscillator and an intermediate frequency amplifier, so it has advantages in its economical and system simplification. The experimental results show the maximum conversion gain 1.5d B and the noise figure 6.5d B at RF center frequency 4GHz and IF 1.1GHz` output oscillating power 4d Bm, efficiency 13.4%, stability -10MHz/V and -0.5MHz/\ulcornerC at oscillating frequency 5.1GHz.The rejection band loss characteristics in band pass filter and low pass filter are -40d B and -30d B, respectively.

  • PDF

Life cycle reliability analyses of deteriorated RC Bridge under corrosion effects

  • Mehmet Fatih Yilmaz
    • Earthquakes and Structures
    • /
    • v.25 no.1
    • /
    • pp.69-78
    • /
    • 2023
  • Life-cycle performance analysis of a reinforced concrete box section bridge was generated. Moreover, Monte Carlo simulation with important sampling (IS) was used to simulate the bridge material and load uncertainties. The bridge deterioration model was generated with the basic probabilistic principles and updated according to the measurement data. A genetic algorithm (GA) with the response surface model (RSM) was used to determine the deterioration rate. The importance of health monitoring systems to sustain the bridge to give services economically and reliably and the advantages of fiber-optic sensors for SHM applications were discussed in detail. This study showed that the most effective loss of strength in reinforced concrete box section bridges is corrosion of the reinforcements. Due to reinforcement corrosion, the use of the bridge, which was examined, could not meet the desired strength performance in 25 years, and the need for reinforcement. In addition, it has been determined that long-term health monitoring systems are an essential approach for bridges to provide safe and economical service. Moreover the use of fiber optic sensors has many advantages because of the ability of the sensors to be resistant to environmental conditions and to make sensitive measurements.

Corrosion resistance performance of arc thermal sprayed Al and Al/epoxy dual metal polymeric coating in 3.5 wt.% NaCl-contaminated concrete pore solution (3.5 wt.% NaCl로 오염된 콘크리트 기공 용액에서 아크 용사 Al 및 Al/에폭시 이중 금속 고분자 코팅의 내식성 성능)

  • Singh, Jitendra Kumar;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.119-120
    • /
    • 2023
  • Corrosion of the steel rebar in coastal environment caused huge economical loss of the globe. Therefore, coating on the steel rebar being used to mitigate the corrosion. In the present study, we have applied epoxy coating on arc thermal sprayed Al coating (a dual metal/polymeric coating) vis-à-vis compared with as coated one (Al coating). The corrosion studies were performed in simulated concrete pore solution with 3.5 wt. % NaCl solution. The morphology of the dual epoxy/Al coating is smooth while Al coating shows rankle and defects. Due to defects, Al coating is susceptible to corrosion while dual epoxy/Al coating has performed excellent compared to as coated one at extended period of immersion.

  • PDF

Dewaxing of Sunflower Seed Oil (해바라기 유(油)의 탈납)

  • Rhee, Joon-Shick
    • Korean Journal of Food Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.112-117
    • /
    • 1979
  • By using the existing caustic refining system with a minimum modification and by using a combination of various emulsifiers(0.2 % sodium hexametaphosphate. 0.05 % sodium lauryl sulfate and 0.001 % dioctyl sodium sulfosuccinate), a new economical dewaxing process for sunflower seed oil was developed in order to reduce the cost of the dewaxing process. The results indicate that the waxes can be removed satisfactorily from the sunflower seed oil by emulsifying. batchwise or continuously, the oil with the aqueous surfactant solution, followed by centrifugation at ambient temperatures $(16{\sim}27^{\circ}C)$. Dewaxing loss for the batch process was satisfactory for both low wax-and high wax-crude oil, whereas dewaxing loss for the continuous process needs to be improved. The results indicate that initial level of wax content (low wax vs. high wax) did not affect the loss for batch process (0.82 % vs. 0.62 %), but affected the loss for continuous processes, regardless of the type of mixing mode (2.28 % and 5.68 % for low wax-and high wax-oil, respectively). It was also noted that the type of mixing mode (centactor vs. static mixer) for the continuous process affected the loss, regardless of the wax content (5.2 % and 2.8 % for contactor and static mixer, respectively).

  • PDF