• Title/Summary/Keyword: Economical Efficiency

Search Result 1,231, Processing Time 0.031 seconds

The Comparison of the Economical Efficiency of Light Sources for a Tunnel Lighting (터널조명용 광원의 경제성 비교)

  • Yi, Chin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.32-42
    • /
    • 2011
  • In this paper to compare the economical efficiency of light sources for a tunnel lighting, we define a model tunnel and design tunnel lighting. And to examine economical efficiency of various tunnel lightings we compare the lighting expenses of tunnels. The results shows high pressure sodium lamps are more economical than fluorescent lamps.

A study on economic analysis of new renewable energy power(photovoltaic, wind power, small hydro, biogas) (신재생에너지 발전(태양광, 풍력, 소수력, 바이오가스)의 경제성 분석 연구)

  • Kim, Chong-Min;Kim, Ki-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.70-77
    • /
    • 2008
  • The purpose of this study evaluates a feasibility and economical efficiency of new renewable energy. According as weather change is serious problem now days, every people make attention to the reduction of greenhouse gas. The revitalization of new renewable energy creates the variety of energy source, stability of energy supply and reduction of greenhouse gas. In this study evaluates a feasibility and economical efficiency from new renewable energy of various photo voltaics, wind power, small hydro and biogas. Feasibility does in standard of technical characteristic, politic support, marketability, establishment present condition and development aim. Economical efficiency does in standard of developmental unit cost, utilization factor, equipment life, politic support cost, interest ratio. The results of this study were as follows photo voltaics, wind, small hydropower, biogas in order feasibility is high. Developmental unit cost, utilization factor, equipment life, politic support cost and analyzed the relationship of interest ratio fluctuation and economical efficiency. From all new renewable energy the utilization factor most is important in economical efficiency but necessary utilization factor is difficult because environmental problem.

A Study on the Selection Method of Foundation Type in the Underground Parking Lot of Apartments (공동주택 지하 주차장 기초형식 선정방법에 관한 연구)

  • Im, Nam-Gi;Lee, Yeong-Do;Bae, Yong-Hwan
    • Journal of the Korea Institute of Building Construction
    • /
    • v.4 no.3
    • /
    • pp.109-116
    • /
    • 2004
  • Normally easy task of plat in urban architecture is that using underground full of activities for increase building site efficiency. Especially for using underground space for the parking lot. Also utilize underground is more increase for fulfill requirement in modern society considered with environmental friendly architecture. The primary objective of this study is to apply analyzed formal foundation type for selecting the optimum type of parking lots considered with structural stability, economical efficiency, construction efficiency, construction duration. This study aim to on criteria decided through the questionaries for the selection considered with in the scale of second stories parking lots underground, parking volume is 80 and reinforced concrete structure. The bearing capacity is 6~8m and downward from surface, healthy ground bearing capacity is 40 t/m2. This study comparative analysis and discuss economical efficiency, construction efficiency, construction duration based constructivist stability which applied Single foundation, Mat foundation, Drop Mat foundation. The result of this study is as follows: First, the result of economical efficiency is that on the basis of single foundation, Drop Mat foundation is 1.88, Mat foundation 2.04 as a comparative analysis on the basis of total construction cost included material cost, labor coast and machinery cost. Second, the result of construction efficiency order is single foundation, Drop Mat foundation, Mat foundation as a comparative analysis on the based connected characteristics. Third, the result of construction duration is that on the basis of Mat Foundation, Drop Mat foundation is 1.33, single foundation is 1.87 as a comparative analysis Critical Path. Forth, Each foundational type characteristics order through the matrix method is that overall each formal type of foundation contraries at economical efficiency and construction efficiency, construction duration. Also expect contradiction between engineers and owners due to engineer pursuit construction duration and ewer to begin with economical efficiency. Fifth, The selection of suitable foundation formal type needs that based consider project characteristic and field condition as according to above result of a comparative analysis. As a result, a comparative analysis economical efficiency, construction efficiency, construction duration of Mat foundation, Drop Mat foundation, single foundation with 3Bay reinforced structure underground parking lots on the healthy ground.

An Introduction and Economical Efficiency analysis of Spring Tension Balancer (스프링식 자동장력 조정장치의 소개 및 경제성 분석)

  • Yoon Yong-Han;Yim Geum-Kwang;Shin Seung-Sik
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.856-861
    • /
    • 2005
  • This paper presents an introduction and economical efficiency analysis of spring tension balancer in trolly wire system. In the overhead trolly wire systems, one of the most things is tension balancer. Because it can be automatically adjusted tension for expansion and contraction of overhead catenary system. In this paper, we introduced spring tension balancer and analyzed economical efficiency of it.

The economical efficiency analysis of LED illuminator application at subway station (지하 역사 LED조명기구의 적용에 대한 경제성 분석)

  • Kim, Youn-Sik;Sim, Jae-Suk;Lee, Gi-Seung
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1868-1872
    • /
    • 2010
  • The LED illuminator has merits that it has low power consumption, long life and emits low Co2 gas. As it has many merits in comparison with existing illuminator it is a realistic alternative. but its possession in illuminator market shows slow increasement unexpectedly. Because its price is very high only low power consumption can not keep pace with economical efficiency. In this paper I analyzed economical efficiency about LED illuminator when it is applied at subway station.

  • PDF

Economical Efficiency Evaluation of the Cold Storage Warehouse with Various Envelope Structures (냉동냉장창고 외피구조 유형별 경제성 평가)

  • 송승영;석호태;황혜주;안홍섭
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1156-1164
    • /
    • 2001
  • This study aims to suggest envelope structure which can improve the insulation performance of cold storage warehouse with cost effectiveness. Envelope structures are classified and economical efficiency of each type is evaluated to the model warehouse. As results, type 3 (PC wall) and 4(sandwich panel wall) have benefits to the middle/large (lifetime of 25 years) and small (lifetime of 12∼13 years) warehouse, respectively.

  • PDF

An Experimental Study of Tire Safety & Economical Efficiency with Respect to Inflation Pressure (공기압에 따른 타이어의 안전성 및 경제성에 관한 실험적 연구)

  • Hong, Seung-Jun;Lee, Ho-Guen
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.1
    • /
    • pp.8-13
    • /
    • 2010
  • Many vehicles have significantly under-inflated tires, primarily because drivers infrequently check their vehicles' tire pressure. When a tire is used while significantly under-inflated, its sidewalls flex more and the tire temperature increases, increasing stress and the risk of failure. In this study we evaluated tire safety and economical efficiency at various inflation pressure. For tire safety we performed FMVSS indoor durability test, measurement of rolling tire temperature, braking performance at dry/wet road condition, and rolling resistance test for economical efficiency. Results show that low pressure decreases tire durability of both speed-increase condition and load-increase condition. Heat temperature of rolling tire increases as pressure decreases and significantly under-inflated tires cause increase of vehicle's stopping distance at wet road condition. Also Under-inflation increases the rolling resistance of a tire and, correspondingly, decreases vehicle's fuel economy.

A study of LCA(Life Cycle Assessment) to a office building remodeling - Focused on Electrical Equipment - (사무소건축 리모델링에서의 전과정 평가에 관한 연구 - 전기 부분을 중심으로 -)

  • Lee, Seon-Dong;Yoo, Ho-Chun
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.3
    • /
    • pp.85-92
    • /
    • 2004
  • Environmental issues become one of today's central concerns due to draining natural resources and environmental pollution. Architecture is given a great deal of weight on the evoking environmental pollution. In this point of view, polluting factors in architectural planning and construction were predicted in advance and alternative plans were studied, In investigation of alternative plans, both environmental pollution and economical efficiency of various alternatives were considered. A office building was analyzed for energy consumption and construction environmental load by appling LCA. Applying LCA to a office building includes a total amount of materials and energy consumption, environmental impacts and economical efficiency evaluation. In present study, LCA applied to electrical part of a office building and economical efficiency evaluation was considered.

Analysis on Durability Performance Enhancement and Economical Efficiency through Chloride Protection for Concrete Structures (콘크리트 구조물의 염해도장을 통한 내구성능 향상 및 경제적 효과분석)

  • Chai, Won-Kyu;Kim, Seong-Heon;Son, Young-Hyun;Park, Ju-Won;Lee, Cheung-Bin
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.155-160
    • /
    • 2010
  • In this study, detailed assessment for durability performance were performed on the chloride protected concrete structures to investigate the effectiveness of chloride protection. And economical efficiency for the chloride protected concrete structures were studied by LCC(Life Cycle Cost) analysis. In the comparison result of the first section repair time, it was found that the chloride protected concrete structures was economical better than the non-protected concrete structures in the long term. According to the analysis result of the accumulated chloride concentration by used time and chloride ion concentration by depth, it can be seen that the permeation through time from chloride has increased two times in the chloride protected concrete structures.

Effect of compact HTS superconduction 7ower cable and evaluation of its economical efficiency (컴퍽트형 고온 초전도 전력 케이블의 기대 효과와 경제성 평가)

  • 최상봉;성기철;조건욱;정성환;김대경;김학만;전영환
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.2
    • /
    • pp.10-14
    • /
    • 2001
  • This paper presents the possible application of a HTS superconducting power cable fro transmitting electric power in metropolitan areas, reflecting its important distinction such as compactness for installation in underground ducts and considerable efficiency improvement comparable to present underground cables. In this paper, we investigated characteristic and market scale compact HTS transmission cable which is possible to install in under-ground ducts. and reviewed its economical efficiency comparing to present existed CV cable construction and duct or tunnel installation.

  • PDF