• 제목/요약/키워드: Earth leakage

검색결과 205건 처리시간 0.021초

충격파 부동작형 누전차단기의 뇌써지 응답 특성 (Lightning Surge Response Characteristics of Non-tripping Type Earth Leakage Breakers for Impulse)

  • 이재복;명성호;조연규;장석훈;김정식;길경석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1688-1690
    • /
    • 2002
  • The unpredictable threat of lightning surge is ever increasing in today's low-voltage power supplies. Thus Surge protection devices for AC mains are more widely used. The false-tripping of the earth leakage breaker (ELB) can be caused by the installation of surge protection devices with MOV. In order to examine the cause of malfunction, the malfunction characteristics of ELBs applied by lightning surge were investigated experimentally. As a result, all of them brought about malfunctions under 7 kV of the impulse voltage. The suitable position of MOV and use of zener diode were suggested to eliminate the problems.

  • PDF

IEC60947-2에 따른 누전차단기의 순시단락시험 과도현상에 대한 연구 (The Transient Analysis of Instant Short-Circuit Test Equipment For Earth Leakage Circuit Breaker)

  • 류행수;김명석;한규환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.357-359
    • /
    • 2003
  • This paper is for the transient analysis of instant short-circuit test equipment according to the test of tripping limits and characteristics under IEC 60947-2. The in-rush current is harmful to almost equipments and the exact testing is not made because of it. LGIS has a instant short-circuit test equipment, but it is not suitable for carrying out instant short-circuit test on ELB(Earth Leakage Circuit breaker) by reason of that. Now, I am going to show a solution for that problem. After applying this method, manufacturer is going to acquire the exact testing result according to the IEC standard. Moreover, Testing laboratory will be trusted by clients.

  • PDF

공장전기설비에서의 누전차단기 오동작과 전력품질 분석 (Power Quality Analysis and Failure of Earth Leakage Breakers in Plant)

  • 이상의;유재근;전정채;전현재;허혜성;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.479-481
    • /
    • 2007
  • This paper presented a actual conditions on a false-tripping of ELB(Earth Leakage Breakers) and an assessment of the harmonics due to non-linear electronic equipment such as personal computers, rectifier, electric furnace and test equipments in plant installations. Actual conditions on a failure of ELB were surveyed and analyzed by making up a question to safety managers of plant installations. Also, power quality measurements such as harmonic currents, voltage and current waveform and current imbalance were made at various plant installations where nuisance tripping of ELB is often occurred. The results of this study can be used in making decisions regarding cause of ELB trip and operating and tripping characteristics test of ELB when subjected to distorted current waveform.

  • PDF

태양광 및 소단위 풍력발전용 변압기 없는 인버터 (Transformer-less Inverter for Photovoltaic and small unit Windturbine System)

  • 박영산
    • 한국정보통신학회논문지
    • /
    • 제8권2호
    • /
    • pp.407-412
    • /
    • 2004
  • 태양광발전 및 소단위 풍력발전에 사용할 수 있는 변압기 없는 인버터를 설계하였다. 멀티 스위칭 방법에 의한 승압쵸퍼회로와 단상 풀브리지 인버터로 구성하였으며 소형화, 저 비용화를 위하여 변압기 없는 방식으로 설계하였다. 변압기 없는 시스템에서 문제가 될 수 있는 접지누설전류의 저감을 위해서는 승압쵸퍼의 스위칭기법 및 인버터 스위칭 등을 통하여 해결하였다

드론 열화상활용 저수지 제체 누수탐사 (Drone Infrared Thermography Method for Leakage Inspection of Reservoir Embankment)

  • 이준구;유영철;김영화;최원;김한중
    • 한국농공학회논문집
    • /
    • 제60권6호
    • /
    • pp.21-31
    • /
    • 2018
  • The result of examination of diagnostic method, which is composed of a combination of a thermal camera and a drone that visually shows the temperature of the object by detecting the infrared rays, for detecting the leakage of earth dam was driven in this research. The drone infrared thermography method was suggested to precise safety diagnosis through direct comparing the two method results of electrical resistivity survey and thermal image survey. The important advantage of the thermal leakage detection method was the simplicity of the application, the quickness of the results, and the effectiveness of the work in combination with the existing diagnosis method.

임베디드 시스템을 이용한 빌딩 누전감시 시스템 (A Leakage Current Supervising Control and Data Acquision in the Building based on Embedded System)

  • 신승우;유종일;장경배;심일주;박귀태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 D
    • /
    • pp.2457-2460
    • /
    • 2004
  • As the usage of electron electricity is rapidly increasing, corresponding accidents also take place proportionately. Although various losses occur very often because of senility of system and maintenance, only a earth leakage current breaker by a leakage current alert is used. That means it is always fraught with dander. This paper, we propose to measure and cut a leakage current and method of taking a measurement current short circuit. Besides, through keeping watch communication with server, prevent electric loss and mishap in advance.

  • PDF

마이크로 용적형 수차의 측면누설손실이 성능에 미치는 영향 (Influence of Side Leakage Loss on the Performance of a Micro Positive Displacement Hydraulic Turbine)

  • 최영도
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.291-295
    • /
    • 2006
  • Recently, greenhouse effect by $CO_2$ gas emitted by use of fossil fuel causes earth environmental problem. As a countermeasure of the global warming. micro hydropower under 100kW becomes the focus of attention for its clean and renewable energy sources. Newly developed micro positive displacement hydraulic turbine shows high efficiency and good applicability for the micro hydropoewer. The purpose of this study is to clarify the influence of leakage loss and effective head on the performance of the positive displacement hydraulic turbine for the further improvement of the turbine performance. The results show that the turbine. with a smaller side clearance. has much higher efficiency than that with bigger side clearance and it can sustain the high efficiency under the wider range of operation conditions. The turbine torque is proportional to the effective head and independent of the flow rate. The leakage is also dependent on the effective head but nearly independent of the flow rate.

인버터 구동 유도 전동기 고주파 모델링 (High Frequency Model of Inverter-fed Induction Motor)

  • 흥선기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.795-797
    • /
    • 2001
  • Voltage varing Fate dv/dt which is applied to induction motor usually makes unnegligible leakage current and it flows through stator winding and motor frame. This kind of harmonic leakage current makes effect on power source and cuases electromagnetic trouble because the motor frame has earth. Therefore in this study, a high frequency induction motor model is developed and analyze the motor performance to explain the phenomena. Inverter model is also developed and is combined with the motel model to prepare the basis of the high frequency effects on inverter fed induction motor.

  • PDF

서지에 대한 누전차단기의 오동작 특성 (Malfunction Characteristics of Earth Leakage Circuit Breakers against Electrical Surges)

  • 송재용;한주섭;박대원;서황동;길경석
    • 한국정보통신학회논문지
    • /
    • 제9권3호
    • /
    • pp.570-575
    • /
    • 2005
  • 저전압 전력계통에 사용되는 누전차단기의 서지에 대한 오동작은 심각한 문제이다. 본 논문에서는 누전차단기의 서지에 대한 영향을 분석하기 위하여 IEC 61009-1와 KS C 4613 규격에 따라 누전차단기를 시험하였다. 서지전압 시험은 국내외 규격에 모두 적용되고 있으며, 서지전류 시험에 대해서는 국제규격 IEC 61009-1에만 규정되어 있다. 실험결과로부터 누전차단기는 서지전압에 대해서는 강인하지만 서지전류에 대해서는 오동작을 발생시켰다. 실제로 누전차단기가 설치되어 있는 환경에서는 서지전류의 침입이 빈번하므로, 누전차단기는 서지전류에 의한 오동작 시험이 수행되어야 하며, 국내규격에도 누전차단기 시험에 서지전류에 의한 평가를 포함하여야 할 것이다.