• Title/Summary/Keyword: Early loading

Search Result 253, Processing Time 0.027 seconds

Effect of fatigue crack propagation on natural frequencies of system in AISI 4140 Steel

  • Bilge, Habibullah;Doruk, Emre;Findik, Fehim;Pakdil, Murat
    • Steel and Composite Structures
    • /
    • v.32 no.3
    • /
    • pp.305-312
    • /
    • 2019
  • In this study, we investigated the effect of fatigue crack propagation of the beams which have a vital importance in engineering applications, on the natural frequency of the system. Beams which have a wide range of applications, are used as fundamental structural elements in engineering structures. Therefore, early detection of any damages in these structures is of vital importance for the prevention of possible destructive damages. One of the widely used methods of early detection of damages is the vibration analysis of the structure. Hence, it is of vital importance to detect and monitor any changes in the natural frequencies of the structure. From this standpoint, in this study we experimentally investigated the effect of fatigue crack propagation on beams produced from 4140 steel, of the natural frequency of the beam. A crack was opened on the $8{\times}16{\times}500mm$ beam using a 3 mm long and 0.25 mm wide wire erosion. The beam, then, underwent 3 point bending tests at 10 Hz with a dynamic fatigue device and its natural frequencies were measured in scheduled intervals and any changes taking place on the natural frequencies of the beam were measured. This data allowed us to identify and measure the crack occurring on the beam subjected to dynamic loading, during the propagation phase. This method produced experimental data. The experimental data showed that the natural frequency of the beam decreased with the propagation of the fatigue crack on the beam.

Effect of Ruthenium Red and Ryanodine on Calcium Ion Metabolism in Oocyte and Early Embryo of Mouse (생쥐의 난자와 초기배아의 칼슘이온 대사에 미치는 Ruthenium Red와 Ryanodine의 영향)

  • Lee Joon Yeong;Hong Soon Cap;Kim Tae Sik;Min Byeong Yeol;Kim Haekwon;Yoon Yong-Dal
    • Development and Reproduction
    • /
    • v.7 no.2
    • /
    • pp.95-103
    • /
    • 2003
  • Intracellular calcium is an important physiological factor in most cells, and ruthenium red and ryanodine play an important role as calcium modulators. Ruthenium red inhibits calcium-induced calcium release(CICR) from the intracellular calcium store. Ryanodine activates calcium release through ryanodine channel. The present experiment was performed to investigate the effects of two modulators on calcium ion metabolism and to determine their dose-dependency in oocyte and early embryo of mouse. Intracellular calcium ion concentration was measured in realtime by using confocal laser scanning microscope(CLSM) after loading of Fluo-3/AM in mouse oocytes and early embryos. Ruthenium red decreased intracellular calcium ion concentration in oocytes and early embryos at its high concentration(30, 300 $\mu$M). Ryanodine increased intracellular calcium ion concentration in oocytes and early embryos in low concentration(0.01 $\mu$M) but decreased that at higher concentrations(1, 10 $\mu$M). These results indicate that two modulators affected calcium ion metabolism in oocyte and early embryo of mouse, and their dose-dependency was different from somatic cell including myocytes.

  • PDF

The effect of early loading on the direct bone-to-implant surface contact of the orthodontic osseointegrated titanium implant (교정력이 골유착성 티타니움 임프란트의 초기 고정에 미치는 영향에 관한 실험적 연구)

  • Chung, Kyu-Rhim;Lee, Sung-Ja
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.173-185
    • /
    • 2001
  • The orthodontic osseointegrated titanium implant, a kind of intraoral skeletal anchorage can be an alternative to tooth-borne anchorage, in case that the conventional tooth-borne anchorage is not available or the anchorage is critical. This study was conducted to elucidate the effect of early loading on the osseointegration of the orthodontic titanium implant and the healing process of the impaired bone at the site of implant after removing it. In two adult beagle dogs24 osseointegrated titanium implants were inserted into the alveolar bone, with 12 implants placed in each dog. In dog1, 6 out of 12 implants were loaded with 200-300gm of force immediately after placing, and the remaining 6 implants were not loaded for 4weeks. In dog2, all 12 implants had healing period of 4weeks, and then were loaded with 200-300gm of force for another 4weeks. Following an observation period of 4 and 8 weeks, the animals were sacrificed. Then the implants and the surrounding bone of dog1 and dog2 were removed, respectively. Undecalcified sections along the long axis of implant were made and the degree of osseointegration was examined under the light microscope. The results were as follows. 1. In the histologic features of tissues around implants anchored in dog1, there was no difference between immediately loaded implants and unloaded implants. Immature woven bone was ingrowing into the thread spaces from the original compacta and in direct contact with the implant surface in part. 2. The premature loading just after 4weeks healing period did not halt the progress of the osseointegration between bone and implant surface. The woven bone around the implants was maturing into the lamellar bone which resembled the structure of the original compacta at the end of 8weeks observation period. 3. Most implants with the inflammed surrounding mucosa were lost or mobile. The mobile implants were encapsulated by fibrous connective tissue which separated the implant surface from the bone. 4. The impaired bone at the site of the implant failed to anchor was showing recovery without inflammatory reaction 2weeks after removing, with the immaure woven bone lined by active osteoblasts and osteoid. Based on the results of this study, the integration of this orthodontic implant seemed to be impaired by the inflammation of the tissue surrounding the Implant rather than by early loading on implant, and increased with time lapsed after placing the implant. The use of implant described in this report can be recommended as an orthodontic anchorage unit immediately after insertion under the careful control of orthodontic force applied and plaque.

  • PDF

Controlled active exercise after open reduction and internal fixation of hand fractures

  • Jun, Dongkeun;Bae, Jaehyun;Shin, Donghyeok;Choi, Hyungon;Kim, Jeenam;Lee, Myungchul
    • Archives of Plastic Surgery
    • /
    • v.48 no.1
    • /
    • pp.98-106
    • /
    • 2021
  • Background Hand fractures can be treated using various operative or nonoperative methods. When an operative technique utilizing fixation is performed, early postoperative mobilization has been advocated. We implemented a protocol involving controlled active exercise in the early postoperative period and analyzed the outcomes. Methods Patients who were diagnosed with proximal phalangeal or metacarpal fractures of the second to fifth digits were included (n=37). Minimally invasive open reduction and internal fixation procedures were performed. At 3 weeks postoperatively, controlled active exercise was initiated, with stress applied against the direction of axial loading. The exercise involved pain-free active traction in three positions (supination, neutral, and pronation) between 3 and 5 weeks postoperatively. Postoperative radiographs and range of motion (ROM) in the interphalangeal and metacarpophalangeal joints were analyzed. Results Significant improvements in ROM were found between 6 and 12 weeks for both proximal phalangeal and metacarpal fractures (P<0.05). At 12 weeks, 26 patients achieved a total ROM of more than 230° in the affected finger. Postoperative radiographic images demonstrated union of the affected proximal phalangeal and metacarpal bones at a 20-week postoperative follow-up. Conclusions Minimally invasive open reduction and internal fixation minimized periosteal and peritendinous dissection in hand fractures. Controlled active exercise utilizing pain-free active traction in three different positions resulted in early functional exercise with an acceptable ROM.

Effects of Equilibration Time, Precooling and Straw Loading Method on Survival of Mouse Embryos Frozen by Vitrification (생쥐 수정란의 유리화 동결보존에 있어서 동결전 처리방법에 관한 연구)

  • Gong, Il-Geun;Lee, Eun-Bong;Gang, Dae-Jin;Park, Chung-Saeng
    • Korean Journal of Animal Reproduction
    • /
    • v.15 no.1
    • /
    • pp.49-57
    • /
    • 1991
  • This study was carried out to investigate the effect of equilibration time, precooling and straw loading method on the post-thaw survival rates of mouse embryos cryopreserved by vitrification method. The effect of the vitrification procedure on the damage of the embryos was also examined by the straining of nuclei using Hoechst 33342. The results obtained were summarized as follows; 1. The equilibration in Medium-1 for 10 minutes was considered to be the optimum equilibration time. Embryos equilibrated in Medium-1 for 10 minutes(81.0%) showed significantly(P<0.05) higher survival rates than those equilibrated for 5 minutes(40.0%) or 15 minutes(74.1%). 2. The survival rate of embryos cryopreserved using the double Medium-2 column(81.0%) was significantly(P<0.01) higher than that using the single Medium-2 column, whish was considered to be due to the double Medium-2 column method being more reliable for preventing contamination of diluent solution of 1M sucrose. 3. The survival rate of compacted morula stage embryos cryopreserved with the precooled and non-precooled Medium-2 was not significantly(P<0.05) different. 4. The number of blastomeres of embryos at late blastocyst stage after culture of mouse morulae for 24 to 28hours was significantly(P<0.05) decreased by freezing embryos using vitrification(53.3${\pm}$1.6 vs 41.4${\pm}$1.5), which was considered to be due to the damage of embryos during vitrification and the delay of embryo development by handling in vitro. 5. The vitrification procedure is considered to be a very simple and efficient method for cryopreservation of embryos at early developmental stage.

  • PDF

The EC3 approach to the design of columns, beams and beam-columns

  • Nethercot, D.A.;Gardner, L.
    • Steel and Composite Structures
    • /
    • v.5 no.2_3
    • /
    • pp.127-140
    • /
    • 2005
  • Procedures given in Eurocode 3 Part 1.1 (EN 1993-1-1) for design of the main types of structural member under given systems of loading are presented and described. Whereas some of these e.g. the procedure for axially loaded columns, are little changed from the early concept that appeared more than 25 years ago in the European Recommendations and have subsequently been adopted in many other steel codes of the world, others such as the interaction formulae for beam-columns are new, with aspects of the provisions still under development. For each type of member the basis of the procedure is described and some comparative comments made.

Application of Compression Molding to Determination of Binder System for Low Pressure Injection Molding (열간압축성형에 의한 저압사출성형 결합제 시스템의 결정)

  • 김상우;이해원;송휴섭;김병호
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.8
    • /
    • pp.823-828
    • /
    • 1994
  • Dispersion condition of Si3N4 powder in molten wax was established by comparing relative viscosity of mixture with 20 vol% solids loading, while the evaluation of compression-molded sample was demonstrated as an effective method for developing a binder system for injection molding. The best dispersion of Si3N4 powder in molten wax was achieved when Si3N4 powder was treated with 5% stearic acid, and the critical powder volume fraction was determined to be about 0.51 from density measurement of compression-molded samples. Samples containing polar secondary binder showed markedly improved green strength, higher thermal expansion and increased wicking rate in the early stage.

  • PDF

Considerations of Occlusion for Implant-Supported Fixed Prostheses (임상가를 위한 특집 1 - 임플란트 고정성 보철물의 교합적 고려사항)

  • Lee, Kyu-Bok
    • The Journal of the Korean dental association
    • /
    • v.51 no.5
    • /
    • pp.242-249
    • /
    • 2013
  • The proper occlusal design is one of the most important factors for the long-term success. The purpose of this research is to investigate and define occlusal considerations to reduce failure of implant-supported fixed prostheses. The physiological movement of implants is markedly lower than that of natural teeth and they also lack in occlusal sensitivity. Proper occulsal pattern may be assigned to compensate for the biological disadvantages and occlusal contacts must be formed where the cantilever effect is minimized. Moreover, the long-term success can be assured by reducing early occulsal loading to avoid implant overloading and selecting appropriate occlusion material.

Stochastic ship roll motion via path integral method

  • Cottone, G.;Paola, M. Di;Ibrahim, R.;Pirrotta, A.;Santoro, R.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.2 no.3
    • /
    • pp.119-126
    • /
    • 2010
  • The response of ship roll oscillation under random ice impulsive loads modeled by Poisson arrival process is very important in studying the safety of ships navigation in cold regions. Under both external and parametric random excitations the evolution of the probability density function of roll motion is evaluated using the path integral (PI) approach. The PI method relies on the Chapman-Kolmogorov equation, which governs the response transition probability density functions at two close intervals of time. Once the response probability density function at an early close time is specified, its value at later close time can be evaluated. The PI method is first demonstrated via simple dynamical models and then applied for ship roll dynamics under random impulsive white noise excitation.

Cyclic-loading Tests of 113-Scale R.C. Exterior Beam-column Joints With Non-Seismic Detailing (비내진 상세를 가진 1/3 축소 R.C. 외부 접합부의 반복 횡하중 실험)

  • 이한선;차병기;고동우;임동운
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.179-184
    • /
    • 2001
  • The objective of this study is to clarify the seismic capacity and the characteristics in the hysteretic behavior of RC structures with nonseismic detailing. To do this, an exterior beam-column subassemblage was selected from a 10-story RC building and 6 1/3-scale specimens were manufactured with 3 variables; ⑴ with and without slab, ⑵ upward and downward direction of anchorage for the bottom bar in beams, and ⑶ with and without hoop bars in the joint region. The test results have shown that ⑴ the existence of slab increased the strength in positive and negative moment, 25% and 62%, respectively; ⑵ the Korean practice of anchorage (downward and 25 $d_{b}$ anchorage length) caused the 8% reduction of strength and the early strength degradation when compared with the case of seismic details; and ⑶ the existence of hoop bars in the joint region does not show significant difference because the size of column is much larger than that of beam.m.

  • PDF