• Title/Summary/Keyword: Early breast cancer

Search Result 498, Processing Time 0.029 seconds

Quantitative Assessment of the Radiation Exposure during Pathologic Process in the Sentinel Iymph Node Biopsy using Radioactive Colloid (방사성 콜로이드를 이용한 감시림프절 생검 병리처리과정에서 방사선 피폭의 정량적 평가)

  • Song, Yoo-Sung;Lee, Jeong-Won;Lee, Ho-Young;Kim, Seok-Ki;Kang, Keon-Wook;Kook, Myeong-Cherl;Park, Weon-Seo;Lee, Geon-Kook;Hong, Eun-Kyung;Lee, Eun-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.309-316
    • /
    • 2007
  • Purpose: Sentinel lymph node biopsy became the standard procedure in early breast cancer surgery. Faculty members might be exposed to a trace amount of radiation. The aim of this study is to quantify the radiation exposure and verify the safety of the procedure and the facilities, especially during pathologic process. Materials and Methods: Sentinel lymph node biopsies with Tc-99m human serum albumin were performed as routine clinical work. Exposed radiation doses were measured in pathologic technologist, nuclear medicine technologist, and nuclear medicine physician using a thermoluminescence dosimeter (TLD) during one month. We also measured the residual radioactivities or absorbed dose rates, the exposure distance and time during procedure, the radiation dose of the waste and the ambient equivalent dose of the pathology laboratory. Results: Actual exposed doses were 0.21 and 0.85 (uSv/study) for the whole body and hand of pathology technologist after 47 sentinel node pathologic preparations were performed. Whole body exposed doses of nuclear medicine physician and technologist were 0.2 and 2.3 (uSv/study). According to this data and the exposure threshold of the general population (1 mSv), at least 1100 studies were allowed in pathology technologist. The calculated exposed dose rates (${\mu}$ Sv/study) from residual radioactivities data were 2.47/ 22.4 ${\mu}$ Sv (whole body/hand) for the surgeon; 0.22/ 0 ${\mu}$ Sv for operation nurse. The ambient equivalent dose of the pathology laboratory was 0.02-0.03 mR/hr. The radiation dose of the waste was less than 100 Bq/g and nearly was not detected. Conclusion: Pathologic procedure relating sentinel lymph node biopsy using radioactive colloid is safe in terms of the radiation safety.(Nucl Med Mol Imaging 2007;41(4);309-316)

Effect of Gd-based MR contrast agents on CT attenuation of PET/CT for quantitative PET-MRI study

  • Ko, In OK;Park, Ji Ae;Lee, Won Ho;Lim, Sang Moo;Kim, Kyeong Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.2
    • /
    • pp.130-136
    • /
    • 2015
  • We evaluate the influence of MR contrast agent on positron emission tomography (PET) image using phantom, animal and human studies. Phantom consisted of 15 solutions with the mixture of various concentrations of Gd-based MR contrast agent and fixed activity of [$^{18}F$]FDG. Animal study was performed using rabbit and two kinds of MR contrast agents. After injecting contrast agent, CT or MRI scanning was performed at 1, 2, 5, 10, and 20 minutes. PET image was obtained using clinical PET/CT scan, and attenuation correction was performed using the all CT images. The values of HU, PET activity and MRI intensity were obtained from ROIs in each phantom and organ regions. In clinical study, patients (n=20) with breast cancer underwent sequential acquisitions of early [$^{18}F$]FDG PET/CT, MRI and delayed PET/CT. In phantom study, as the concentration increased, the CT attenuation and PET activity also increased. However, there was no relationship between the PET activity and the concentration in the clinical dose range of contrast agent. In animal study, change of PET activity was not significant at all time point of CT scan both MR contrast agents. There was no significant change of HU between early and delayed CT, except for kidney. Early and delayed SUV in tumor and liver showed significant increase and decrease, respectively (P<0.05). Under the condition of most clinical study (< 0.2 mM), MR contrast agent did not influence on PET image quantitation.

Prevalence and Survival Patterns of Patients with Bone Metastasis from Common Cancers in Thailand

  • Phanphaisarn, Areerak;Patumanond, Jayantorn;Settakorn, Jongkolnee;Chaiyawat, Parunya;Klangjorhor, Jeerawan;Pruksakorn, Dumnoensun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.9
    • /
    • pp.4335-4340
    • /
    • 2016
  • Background: Bone metastasis is a single condition but presents with various patterns and severities. Skeletal-related events (SREs) deteriorate overall performance status and reduce quality of life. However, guidelines for early detection and management are limited. This study includes a survey of the prevalence of bone metastasis in cases with common cancers in Thailand as well as a focus on survival patterns and SREs. Materials and Methods: A retrospective cohort analysis was conducted using a database of the Chiang Mai Cancer Registry and the Musculoskeletal Tumor Registry of the OLARN Center, Chiang Mai University. The prevalence of bone metastasis from each type of primary cancer was noted and time-to-event analysis was performed to estimate cancer survival rates after bone metastasis. Results: There were 29,447 cases of the ten most common cancers in Thailand, accounting for 82.2% of the entire cancer registry entries during the study period. Among those cases, there were 2,263 with bone metastases, accounting for 7.68% of entries. Bone metastasis from lung, liver, breast, cervix and prostate are common in the Thai population, accounting for 83.4% of all positive cases. The median survival time of all was 6 months. Of the bone metastases, 48.9% required therapeutic intervention, including treatment of spinal cord and nerve root compression, pathological fractures, and bone pain. Conclusions: The frequency of the top five types of bone metastasis in Thailand were different from the frequencies in other countries, but corresponded to the relative prevalence of the cancers in Thailand and osteophilic properties of each cancer. The results of this study support the establishment of country specific guidelines for primary cancer identification with skeletal lesions of unknown origin. In addition, further clinical studies of the top five bone metastases should be performed to develop guidelines for optimal patient management during palliative care.

Quality Management for Mammography Equipment and Mammography (유방촬영장치와 유방검사를 위한 품질관리)

  • zheng, Hao Yang;Cho, Pyong Kon;Kim, Tae Woo;Kim, Jung Soo;Jang, Hyon Chol;Lee, Mi Hwa
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.683-692
    • /
    • 2018
  • Mammography using mammography equipment is a method of examination that is being employed most widely to diagnose the early stages of breast cancer. Detecting or diagnosing a fibrous tissue, micro calcification, or mass in the breast is influenced by the quality management of mammography equipment considerably. Particularly in mammography, quality management refers to a behavior of figuring out and correcting all sorts of hindrance factors that can cause all the problems related to the equipment associated with the diminishment of diagnosed area due to the reduction of image quality in clinical imaging in advance and maintaining a consistent level of image quality and obtaining a proper image. Here, these researchers aim to summarize and report the general contents of quality management in mammography using mammography equipment.

Rates of Change to a Positive Result in Subsequent Screening Mammography in Korean Women: A Retrospective Observational Study

  • Bae, Jong-Myon;Shin, Sang Yop;Kim, Eun Hee;Kim, Yoon-Nam;Nam, Chung Mo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.48 no.1
    • /
    • pp.48-52
    • /
    • 2015
  • Objectives: This retrospective cohort study aimed at calculating some parameters of changes in the findings of the subsequent screening mammography (SSM) in female Korean volunteers. Methods: The study included screenees aged 30 to 79 years who underwent SSM voluntarily after testing negative in the baseline screenings performed between January 2007 and December 2011. A change to a positive result was defined as category 4 or 5 by using the American College of Radiology Breast Imaging Reporting and Data System. The proportion of results that had changed to positive (CP, %) was calculated by dividing the number of cases with results that were positive in the SSM by the total number of study participants. The rate of results that had changed to positive (CR, cases per 100 000 screenee-months) was calculated by dividing the number of cases with results that were positive in the SSM by the total number of months of the follow-up period. Results: The overall CP and CR in all age groups (n=77 908) were 2.26% and 93.94 cases per 100 000 screenee-months, respectively. The median CP interval in the subjects who had positive SSM results was 30 to 36 months, while that in the age group of 30 to 39 years was shorter. Conclusions: Different screening intervals should be considered among women aged between 30 and 59 years. In addition, a strategy for a screening program should be developed for the age group of 30 to 39 years, in particular.

A Study on Absorbed Dose in the Breast Tissue using Geant4 simulation for Mammography (유방촬영에서 Geant4 시뮬레이션를 이용한 유방조직내 흡수선량에 관한 연구)

  • Lee, Sang-Ho;Lee, Jong-Seok;Han, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.345-352
    • /
    • 2012
  • As the breast cancer rate is increasing fast in Korean women, people pay more attention to mammography and number of mammography have been increasing dramatically over the last few years. Mammography is the only means to diagnose breast cancer early, but harms caused by radiation exposure shouldn't be overlooked. Therefore, it is important to calculate the radiation dose being absorbed into the breast tissue during the process of mammography for a protective measure against radiation exposure. Because it is impossible to directly measure the radiation dose being absorbed into the human body, statistical calculation methods are commonly used, and most of them are supposed to simulate the interaction between radiation and matter by describing the human body internal structure with anthropomorphic phantoms. However, a simulation using Geant4 Code of Monte Carlo Method, which is well-known as most accurate in calculating the absorbed dose inside the human body, helps calculate exact dose by recreating the anatomical human body structure as it is through the DICOM file of CT. To calculate the absorbed dose in the breast tissue, therefore, this study carried out a simulation using Geant4 Code, and by using the DICOM converted file provided by Geant4, this study changed the human body structure expressed on the CT image data into geometry needed for this simulation. Besides, this study attempted to verify if the dose calculation of Geant4 interlocking with the DICOM file is useful, by comparing the calculated dose provided by this simulation and the measured dose provided by the PTW ion chamber. As a result, under the condition of 28kVp/190mAs, the Difference(%) between the measured dose and the calculated dose was found to be 0.08 %~0.33 %, and at 28 kVp/70 mAs, the Difference(%) of dose was 0.01 %~0.16 %, both of which showed results within 2%, the effective difference range. Therefore, this study found out that calculation of the absorbed dose using Geant4 Simulation is useful in measuring the absorbed dose in the breast tissue for mammography.

The Value of Delayed $^{18}F$-FDG PET/CT Imaging for Differentiating Axillary Lymph Nodes in Breast Cancers (유방암 환자에서 액와 림프절 진단을 위한 $^{18}F$-FDG PET/CT 지연 검사의 유용성)

  • Ji, Young-Sik;Son, Ju-Cheol;Park, Cheol-Woo
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.313-318
    • /
    • 2013
  • Positron emission tomography/computed tomography (PET/CT) imaging with fluorodeoxyglucose (FDG) have been used as a powerful fusion modality in nuclear medicine not only for detecting cancer but also for staging and therapy monitoring. Nevertheless, there are various causes of FDG uptake in normal and/or benign tissues. The purpose of present study was to investigate whether additional delayed imaging can improve the diagnosis to differentiate the rates of FDG uptake at axillary lymph nodes (ALN) between malignant and benign in breast cancer patients. 180 PET/CT images were obtained for 27 patients with ALN uptake. The patients who had radiotherapy and chemotherapy were excluded from the study. $^{18}F$-FDG PET/CT scan at 50 min (early phase) and 90 min (delayed phase) after $^{18}F$-FDG injection were included in this retrospective study. The staging of cancers was confirmed by final clinical according to radiologic follow-up and pathologic findings. The standardized uptake value (SUV) of ALN was measured at the Syngo Acquisition Workplace by Siemens. The 27 patients included 18 malignant and 9 ALN benign groups and the 18 malignant groups were classified into the 3 groups according to number of metastatic ALN in each patient. ALNs were categorized less than or equal 3 as N1, between 4 to 9 as N2 and more than 10 as N3 group. Results are expressed as the mean${\pm}$standard deviation (S.D.) and statistically analyzed by SPSS. As a result, Retention index (RI-SUV max) in metastasis was significantly higher than that in non-metastasis about 5 fold increased. On the other hand, RI-SUV max in N group tended to decrease gradually from N1 to N3. However, we could not prove significance statistically in malignant group with ANOVA. As a consequence, RI-SUV max was good indicator for differentiating ALN positive group from node negative group in breast cancer patients. These results show that dual-time-point scan appears to be useful in distinguishing malignant from benign.

Microcalcification Extraction by Using Automatic Thredholding Based on Region Growing (영역 성장법을 기반으로 자동적인 임계치 설정을 이용한 미세 석회화 추출)

  • 원철호;권용준;이정현;박희준;임성운;김명남;조진호
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.235-242
    • /
    • 2004
  • In this paper, we proposed the algorithm for detection of microtalcification by automatic threshold decision based on region growing method. The region for optimal threshold is grown from local maximum pixel by increasing repeatedly threshold in microralcification candidate region. Then, the optimal threshold is automatically decided at the maximum value of the contrast and edge sharpness in this region. Microcalcifications could be efficiently detected as satisfied result that true positive ratio is 81.5% and average false positive numbers are 1.1 about total 299 microcalcifirations in real image. In a result, we showed that this algorithm can be used to aid diagnostic-radiologist for the diagnosis of the early phase of breast cancer.

Peutz-Jeghers Syndrome: A Case Report and Review of Literature (Peutz-Jeghers 증후군: 증례보고와 문헌고찰)

  • Kim, Hyun Soo;Kim, Soung Min;Choi, Jin Young;Myoung, Hoon;Lee, Suk Keun;Lee, Jong Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.5
    • /
    • pp.363-366
    • /
    • 2012
  • Peutz-Jeghers syndrome is a rare syndrome with characteristic features of multiple hamartomatous polyps and mucocutaneous pigmentation. This syndrome is an autosomal dominant disease, and has complications related with polyps of the gastrointestinal tract, such as small bowel obstruction, iron deficiency anemia associated with bleeding, and intussusceptions. Many studies have reported about higher cancer risk of patients with this syndrome than those with no syndrome in the gastrointestinal tract, including gastric, duodenal, jejunal and the extragastrointestinal organs, such as gallbladder, breast and reproductive system. There are guidelines for periodic test for early detection and treatment for higher risk organs. We report a case of Peutz-Jeghers syndrome patient in the emphasis of Oral and Maxillofacial surgeon's role with review of the literature.

Anticancer Effects of the Isoflavone Extract from Chungkukjang via Cell Cycle Arrest and Apoptosis in MDA-MB-453 Cells (청국장에서 얻은 Isoflavone의 MDA-MB-453세포에서 항암효과 및 관련 기전)

  • Shin, Jin Young;Kim, Taehee;Kim, An Keun
    • YAKHAK HOEJI
    • /
    • v.58 no.1
    • /
    • pp.33-39
    • /
    • 2014
  • The objective of this study is to evaluate the anticancer effects of the isoflavone extract from Chungkukjang in human breast cancer, MDA-MB-453 cells. For this study, MDA-MB-453 cells were treated with 12.5, 25, and $50{\mu}g$ isoflavone extract for 24, 48, and 72 hr. Cell proliferations were decreased in a time- and dose-dependent manner. Reduced cell proliferation was suspected by apoptosis or cell cycle arrest. Therefore, after treatment of $50{\mu}g$ isoflavone extract, apoptotic cells were investigated by annexin V staining. The results indicated that isoflavone extract increased the number of early apoptotic cells compared with control. Cleaved PARP was also increased. Next, we investigated the cell cycle and related proteins. The isoflavone extract leads to cell cycle arrest at the G2/M phase. Moreover isoflavone extract had influenced cell cycle relate proteins such as cyclin B1, cyclin A, and p21. These results suggest that isoflavone extract from Chungkukjang induce apoptosis and cell cycle arrest at G2/M phase via regulation of cell cycle-related proteins in MDA-MB-453 cells.