• 제목/요약/키워드: Early Response Type

검색결과 171건 처리시간 0.025초

An Analysis of Working Hours by Type of Sprinkler Head Used at Indoor Gymnasiums

  • Ahn, Jae-Cheon;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • 제10권4호
    • /
    • pp.117-123
    • /
    • 2021
  • This study aims to analyze working hours of sprinkler heads when a fire occurs at an indoor gymnasium while sprinkler heads are installed in division of standard response type, special response type, and earlier response type. The fire scenario was designed under the assumption that the fire started from overheating of a heater in the indoor gymnasium has transferred on to a couch to spread. The analysis on the operation time of the standard response type sprinkler head, the special response type sprinkler head and the early response sprinkler head was conducted. The result showed that, in case of fire in a gymnasium, the time for opening of the heat sensor due to the heat from the fire varies by the type of the sprinkler head. When a special response type sprinkler is installed, it worked below the assessment standards. When an early response sprinkler head is installed, it worked appropriately according to assessment standards. Based on the results, we found that sprinkler heads will work properly when installed according to design relevant to laws and regulations. This means that there is a limit in installation of sprinkler heads based on the existing law-based design as for indoor gymnasiums. Again, we conclude that if sprinkler heads are installed based on design made through laws and regulations, more time will be needed for operation, making it highly likely to fail to stop a fire at an earlier point of time.

랙크식 물류창고 조기 화재감지를 위한 최적 화재감지기 설치방법에 관한 실험연구 (An Experimental Study on the Optimum Installation of Fire Detector for Early Stage Fire Detecting in Rack-Type Warehouses)

  • 최기옥;김동석;홍성호
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.38-45
    • /
    • 2017
  • This paper is an experimental study to find an optimal detection method for detecting fire early in a rack-type warehouse stored with goods. In this study, we constructed rack-type structure with the fourth floor of 13.5 m high and conducted fire experiments which were to measure flow of heat/smoke in rack-type structure and response time of fire detectors. The detectors used at experiments were fixed temperature type detectors, rate of rise detectors, photoelectric smoke detectors, air sampling smoke detectors and flame detectors. The used ignition sources are n-heptane fire for response of heat detection and cotton fire for response of smoke detection. The fixed temperature type detectors, rate of rise detectors and photoelectric detectors were installed to every rack level respectively. The results show that the rate of rise detector should be installed every 2 levels and photoelectric smoke detector should be installed every 4 levels for the early stage fire detection. Air sampling smoke detectors can detect fire early in response to control of sensitivity, but there is a problem in false alarm. The fixed temperature detector is not suitable for early stage fire detection in warehouse and flame detector not worked if flame is not visible, so it need to install combination with other detector.

Long Double-stranded RNA Induces Sequence-specific RNA Interference and Type I Interferon Responses in Rock Bream (Oplegnathus fasciatus)

  • Zenke, Kosuke;Kim, Ki-Hong
    • Fisheries and Aquatic Sciences
    • /
    • 제13권1호
    • /
    • pp.56-62
    • /
    • 2010
  • To determine whether long double-stranded RNA (dsRNA) induces RNA interference and type I interferon (IFN) responses in fish, long dsRNAs encoding enhanced green fluorescent protein (EGFP), GFPuv, and polyinosinic-polycytidylic acid sequences were co-injected with an EGFP expressing plasmid, into rock bream (Oplegnathus fasciatus). We investigated the EGFP mRNA and protein levels, and the transcriptional responses of dsRNA-dependent protein kinase and Mx1 genes. Long dsRNAs were strong inducers of a type I IFN response in rock bream, resulting in nonspecific suppression of exogenous gene expression. Furthermore, sequence-specific knockdown of exogenous gene expression at the mRNA level was detected at an early phase (24 h). These results suggested that long dsRNA may inhibit exogenous gene expression through an early mRNA interference response and a later type I IFN response in fish.

반응시간지수(Response Time Index)를 이용한 국내 화재감지기 등급분류에 관한 연구 (A Study on the Classification of Domestic Fire Detector using Response Time Index)

  • 홍성호;김동석;최기옥
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.46-51
    • /
    • 2017
  • This paper presents classification of domestic fire detector using response time index. Response time is measured using fire detector distributed in Korea, and the response time index is estimated. Plunge test prescribed by FM is conducted to measure response time of fire detector. The detector used to test is fixed temperature type(thermistor and bimetal type) and rate of rise temperature type(thermistor and pneumatic type). The nominal operation temperature of fixed temperature type detector is $70^{\circ}C$ and rate of rise temperature is $15^{\circ}C/min$. The fixed temperature type is measured 7 products, and the rate of rise temperature type is measured 5 products. The results show that in case of fixed temperature type(thermistor) is classified "Quick" or "Standard" and fixed temperature type(bimetal) is not classified. The rate of rise temperature type(thermistor) is classified "Fast" or "Ultra Fast" and the rate of rise temperature type(pneumatic) is classified "Very Fast" or "Ultra Fast". The pneumatic type shows more fast response than thermistor type. Also these results indicate the fixed temperature type(bimetal) is not suitable for early stage fire detection.

국내.외 철도사고유형 분석을 통해 초기 사고발생 인식.전파를 위한 오감인지 대응연구 (The recognition response research of five sences for the first accident occurrence cognizance and spread through the analysis of railroad accident type at domestic and foreign)

  • 양도철;황성근
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1180-1186
    • /
    • 2007
  • This paper contains that the current emergency response procedure through the railroad accident type at domestic and foreign, and the response program which is more systematic as a result of improving weaknesses. Because the response program at home is less sufficient than developed country's, we have made an investigation into system of classification in America, British, Germany, Japan for organizing separate emergency response code. we have researched the recognition response of five senses for minimizing the accident damage in a way of spreading the emergency response type analyzed through the accident procedure according to the feature of five senses by the first recognizer. Based on the first recognitions response of five senses, the scenario has been established according to each types and the criteria of accident has been researched through classifying the recognition of five senses response level, early response level, self-response level, outside support level.

  • PDF

안정성증강 작동기와 트림 작동기를 이용한 헬리콥터 자세명령반응타입 제어시스템 설계 (Helicopter Attitude Command Response Type Control System Design using SAS Actuators and Trim Actuators)

  • 김응태;최인호;현정욱
    • 한국항공운항학회지
    • /
    • 제21권4호
    • /
    • pp.34-40
    • /
    • 2013
  • Attitude command response type required for enhanced handling qualities of helicopter can be implemented by mechanical automatic flight control system with SAS actuators which have limited authorities. However, the early saturation of SAS actuator hinders the helicopter from following the attitude command for large stick command. Auto-trim controller can delay SAS actuator's saturation by utilizing trim actuators and allows the attitude command response type for larger stick command. This paper describes the control law for limited authority system of helicopter with auto-trim. Limited authority system is applied to BO-105 linear dynamic model and simulation is performed along with handling quality analysis.

Early adjusting damping force for sloped rolling-type seismic isolators based on earthquake early warning information

  • Hsu, Ting-Yu;Huang, Chih-Hua;Wang, Shiang-Jung
    • Earthquakes and Structures
    • /
    • 제20권1호
    • /
    • pp.39-53
    • /
    • 2021
  • By means of installing sloped rolling-type seismic isolators (SRI), the horizontal acceleration transmitted to the to-be-protected object above can be effectively and significantly reduced under external disturbance. To prevent the maximum horizontal displacement response of SRI from reaching a threshold, designing large and conservative damping force for SRI might be required, which will also enlarge the transmitted acceleration response. In a word, when adopting seismic isolation, minimizing acceleration or displacement responses is always a trade-off. Therefore, this paper proposes that by exploiting the possible information provided by an earthquake early warning system, the damping force applied to SRI which can better control both acceleration and displacement responses might be determined in advance and accordingly adjusted in a semi-active control manner. By using a large number of ground motion records with peak ground acceleration not less than 80 gal, the numerical results present that the maximum horizontal displacement response of SRI is highly correlated with and proportional to some important parameters of input excitations, the velocity pulse energy rate and peak velocity in particular. A control law employing the basic form of hyperbolic tangent function and two objective functions are considered in this study for conceptually developing suitable control algorithms. Compared with the numerical results of simply designing a constant, large damping factor to prevent SRI from pounding, adopting the recommended control algorithms can have more than 60% reduction of acceleration responses in average under the excitations. More importantly, it is effective in reducing acceleration responses under approximately 98% of the excitations.

안정성증강 작동기를 이용한 Fly-By-Wire 헬리콥터 제어법칙 설계에 대한 연구 (A Study on Fly-By-Wire Helicopter Control Law Design using SAS Actuators)

  • 김응태;최인호
    • 한국항공운항학회지
    • /
    • 제23권1호
    • /
    • pp.67-73
    • /
    • 2015
  • The previous limited authority system capable of implementing attitude command response type and translational command response type by operating SAS actuator has the problem of early saturation of SAS actuator since SAS actuator should compensate the mechanical linkage displacement caused by control sick movement. In this paper, a limited authority system where flight control computer receives the command from the control stick which is not connected to the mechanical linkage is described. In this system the compensation by the SAS actuator is not necessary and SAS actuator saturate later. SAS actuator saturation problem can be further relaxed by using the trim actuator. This new limited authority system is applied to BO-105 model, simulation is performed for the doublet input and pirouette maneuver is also simulated and analyzed.

Expression Analysis of Lily Type Lectin Isotypes in the Rock Bream, Oplegnathus fasciatus: in the Tissue, Developmental Stage and Viral Infection

  • Lee, Young Mee;Yang, In Jung;Noh, Jae Koo;Kim, Hyun Chul;Park, Choul-Ji;Park, Jong-Won;Noh, Gyeong Eon;Kim, Woo-Jin;Kim, Kyung-Kil
    • 한국발생생물학회지:발생과생식
    • /
    • 제20권4호
    • /
    • pp.297-304
    • /
    • 2016
  • Lectins belong to the pattern-recognition receptors (PRRs) class and play important roles in the recognition and elimination of pathogens via the innate immune system. Recently, it was reported that lily-type lectin-1 is involved when a pathogen attacks in the early immune response of fish. However, this study is limited to information that the lectin is involved in the innate immune response against viral infection. In the present study, the lily-type lectin-2 and -3 of Oplegnathus fasciatus (OfLTL-2 and 3) have been presented to be included B-lectin domain and two D-mannose binding sites in the amino acid sequence that an important feature for the fundamental structure. To investigate the functional properties of OfLTLs, the tissue distribution in the healthy rock bream and temporal expression during early developmental stage analysis are performed using quantitative real-time PCR. OfLTL-2 and 3 are predominantly expressed in the liver and skin, but rarely expressed in other organ. Also, the transcripts of OfLTLs are not expressed during the early developmental stage but its transcripts are increased after immune-related organs which are fully formed. In the challenge experiment with RBIV (rock bream iridovirus), the expression of OfLTLs was increased much more strongly in the late response than the early, unlike previously known. These results suggest that OfLTLs are specifically expressed in the immune-related tissues when those organs are fully formed and it can be inferred that the more intensively involved in the second half to the virus infection.

청소년 전기 여학생의 상의 치수 규격에 관한 연구 (The Apparel Sizing System of Early Adolescent Gins - focusing on Upper Garments -)

  • 정화연;서미아
    • 복식문화연구
    • /
    • 제13권4호
    • /
    • pp.526-539
    • /
    • 2005
  • Recently in the apparel industry, early adolescent girls are emerging as a new consumer group. In response to this, companies are developing clothes, cosmetics, underwear, etc. This study proposed a new size range and size interval for early adolescent girls and presented reference measurements for body parts necessary in designing clothes. For this purpose, a total of 529 girls aged between 10 and 14 were measured and data were collected from 42 anthropometric measurements and 41 photographic measurements per a person. SAS 8.1 was used in data analysis including means, standard deviations, frequency analysis. Based on the results, this study proposed: for Type A - 7 sizes (140A-67, 145A-65, 145A-69, 150A-69, 150A-73, 155A-73, 155A-76): for Type X - 7 sizes (150x-72, 155x-72, 155x-77, 160x-77, 160x-80, 165x-77, 165x-80); and for Type H - 8 sizes (145H-74, 145H-82, 150H-78, 150H-82, 155H-82, 155H-86, 160H-86, 160H-88). Reference measurements suggested for upper garments were 9 items. The outcome of this study may be used as a basic material for adolescent apparel manufacturers to set their apparel sizing system and to supply their consumers, namely, adolescent girls with products fitting their somatotype.

  • PDF