• 제목/요약/키워드: Ear-band

검색결과 34건 처리시간 0.027초

손목밴드를 이용한 내관지압이 중이수술 후 오심과 구토에 미치는 효과 (Effects of the Nei-Guan Acupressure by Wrist Band on Postoperative Nausea and Vomiting after Middle Ear Surgery)

  • 이명윤;민혜숙
    • 대한간호학회지
    • /
    • 제38권4호
    • /
    • pp.503-512
    • /
    • 2008
  • Purpose: This study was to identify the effects of Nei-Guan accupressure using a wrist band on postoperative nausea and vomiting after middle ear surgery. Methods: The study design was a nonequivalent control group non-synchronized posttest design. Forty patients were assigned into two groups of 20 patients, the wrist band group and the control group. In the wristband group, acupressure was applied with a wrist band on the P6 point at both wrists from 30 min before to 24 hr after anesthesia. Results: The 1st hypothesis 'Applied wrist band groups will have a greater reduction in the nausea & vomiting grades by INVR than the control group' was accepted (t=2.303, p=.028). The 2nd hypothesis 'The Applied wrist band groups will have a greater reduction in the occurrence of nausea & vomiting than the control group' was partly accepted. The 3rd hypothesis 'The applied wrist band group will have a greater reduction in injection of antiemetics for 24 hr. post anesthesia than the control group' was rejected. Conclusion: Acupressure on the P6 point using a wrist band is effective to alleviate nausea for middle ear surgery patients.

특정주파수 소음제거를 위한 능동소음제어식 청각보호구 개발연구 (development of an ear-muff with active noise control for selective noise attenuation)

  • 김동균;김옥현
    • 대한기계학회논문집A
    • /
    • 제21권12호
    • /
    • pp.2068-2072
    • /
    • 1997
  • Acoustic noise has become an increasingly important issue, especially in the industrial environment. Nowadays home and office are not exceptional, mainly due to the increase in the usage of machinery. Active Noise Control(ANC) becomes efficiently an available tool for the noise suppression with rapid advances of solid state electronics. In this study an ANC system is developed for audio headphone to work as a noise protector, so called an ear-muff. The system is developed to kill a certain frequency band noises selectively which is purposed to suppress only the dominant ambient noise such that normal numan conversation is not disturbed with wearing the ear-muff. For the purpose, an ANC design strategy is suggested and implemented with an analogue control circuit. The performance is evaluated by frequency response test, which shows well consistence with theoretical one. The results are so satisfactory that noise of 640 Hz, which is aimed to suppress, is reduced by 20db without significant distortion in other frequency band.

저압 호스용 밴드의 체결특성에 관한 연구 (A Study on Swaging Characteristics of Band for Low Pressure Hose)

  • 김영규;김필종;조석범;권부길
    • 한국가스학회지
    • /
    • 제9권3호
    • /
    • pp.32-37
    • /
    • 2005
  • LP가스나 도시가스시설의 저압 호스 체결에서 견고함과 기밀성을 높이기 위해 호스밴드를 사용한다. 본 연구에서는 호스밴드의 성능 파악과 안전한 체결 거리의 제시를 위하여 호스밴드에 대한 내압강도와 당김력을 측정하였다. 호스밴드의 체결력은 스프링밴드 보다는 귀형밴드에서 높게 나타났으며 최적의 호스밴드 체결거리는 호스접속 끝단부로부터 1${\~}$2 mm일 때에 우수한 것으로 파악되었다.

  • PDF

Ear Simulator를 이용한 충격소음 측정방법에 대한 고찰 (A Empirical Review of the Measurement Method for the Impulse Noise Using Ear Simulator)

  • 송기혁;정성학
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2014년도 제49차 동계학술대회논문집 22권1호
    • /
    • pp.425-426
    • /
    • 2014
  • 충격소음(Impulse Noise) 측정 시 지그(Ear Simulator)가 자체적으로 음압측정에 미치는 영향을 확인하기 위해 지그를 이용하여 실내에서 충격소음을 측정하였다. 측정의 신뢰성과 정확성을 확보하기 위해 마이크로폰과 지그에서 동일조건에서 동시에 데이터를 수집하였다. 추가로 헤드&토르소에서 실험을 실시하였다. 최대음압레벨과 1/3옥타브 밴드 결과를 비교분석함으로써 측정 방법에 따른 차이점을 발견하였다.

  • PDF

유한요소 모델을 이용한 중이의 소리전달 특성 해석 (Finite Element Analysis of Sound Transfer Characteristics for Middle Ear)

  • 갈영민;백무진;이두호
    • 대한기계학회논문집A
    • /
    • 제35권12호
    • /
    • pp.1563-1571
    • /
    • 2011
  • 본 연구에서는 인간중이의 소리전달특성 계산을 위한 유한요소모델을 개발하였다. 이소골의 형상을 얻기 위하여 한국인 사체에서 추출한 측두골을 마이크로 CT 촬영하여 3 차원 입체모델로 변환하였다. 유한요소모델은 이소골, 고막, 인대와 근육 등을 포함하여 구성하였다. 유한요소모델을 이용하여 고막에서 등골족판까지의 응답함수를 계산한 후 측정값을 갖는 선행연구와 비교하였고 그 결과 10 kHz 주파수 대역까지 소리전달특성을 잘 표현하고 있음을 보였다. 또한 유한요소 모델을 구성하는 주요 물성인자의 변화에 대한 소리전달특성의 변화를 살피고 침등골관절의 강성값이 중이의 소리전달특성에 큰 영향을 미침을 보였다.

A Real-time Tinnitus Treatment System Using Tinnitus Frequency Removal and Adjacent Frequency Amplification on Mobile Device

  • Park, Dae-Hyun;Kim, Yoon
    • 한국컴퓨터정보학회논문지
    • /
    • 제20권11호
    • /
    • pp.111-118
    • /
    • 2015
  • In this paper, we propose a new tinnitus treatment system that removes the frequency band where the ear noises is generated and amplifies the around frequency bands in order to treat a nonstop buzzing in the ears, that is one among the disease commonly generated in modern people. Mostly the tinnitus is generated by the tunability with the neighboring nerves while the part of the cerebral cortex which is unable to react to the stimuli by the sound of the specific frequency band reacts to other frequency band. Therefore, the excitability activity by the tunability of the cerebral cortex is suppressed and the remedial value is gotten by removing the tinnitus frequency band, and the around frequency bands are amplified to strengthen the remedial value. Experimental results show that the tinnitus can be treated conveniently if the patients use the android application which the proposed technique is applied to.

A New Hearing Aid Algorithm for Speech Discrimination using ICA and Multi-band Loudness Compensation

  • Lee Sangmin;Won Jong Ho;Park Hyung Min;Hong Sung Hwa;Kim In Young;Kim Sun I.
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권3호
    • /
    • pp.177-184
    • /
    • 2005
  • In this paper, we proposed a new hearing aid algorithm to improve SNR(signal to noise ratio) of noisy speech signal and speech perception. The proposed hearing aid algorithm is a multi-band loudness compensation based independent component analysis (ICA). The proposed algorithm was compared with a conventional spectral subtraction algorithm on behind-the-ear type hearing aid. The proposed algorithm successfully separated a target speech signal from background noise and from a mixture of the speech signals. The algorithms were compared each other by means of SNR. The average improvement of SNR by ICA based algorithm was 16.64dB, whereas spectral subtraction algorithm was 8.67dB. From the clinical tests, we concluded that our proposed algorithm would help hearing aid user to hear clearly a target speech in noisy conditions.

다수다얼성 옥수수의 동위효소 특성 (Isozymic Characteristics of Multiple-Ear and Tiller Maize Lines)

  • 이희봉;최봉호
    • 한국작물학회지
    • /
    • 제32권1호
    • /
    • pp.16-23
    • /
    • 1987
  • 다수다얼성 옥수수의 동위효소 특성을 구명하고 자얼성성 품종을 비교하여 생육단계에 따라 여러 조직을 6% polyaclamide gel을 사용 peroxidase와 esterase 동위효소 패턴을 관찰하였던 결과는 다음과 같다. 1. 성숙한 옥수수의 엽, 간, 업소. 근 및 미숙종자의 조직에서 독특한 peroxidase의 동위효소의 존재가 확인되었다. 2. 암조건에서 7일간 자란 다수다얼성 계통의 중심주와 초엽조직은 peroxidase 도위효소의 차이를 나타내는데 효과적이었다. 3. Esterase의 동위효소에 대한 활성은 양친의 경위가 그들의 교잡종보다. 밴드수나 활성이 높았다. 4. Esterase에 대한 밴드는 암조건인 7 일 유묘상태의 중심주, 초엽, 미숙종자에서 뚜렸한 차이가 있었다. 5. 효과적인 동위효소 관찰을 위해서는 성묘보다는 유묘조직이 유리하게 보였다. 6. 흑조위축병에 감염된 옥수수 잎은 PX나 EST 동위효소에서 모두 뚜렷한 차이를 보였다.

  • PDF

분얼형 옥수수의 식물학적 특성과 RAPD 분석에 의한 근연관계 (Relationship with botanical characteristics and RAPD analysis of maize inbred lines with tillers)

  • 김철민;이희봉;최현구;정재영;김기훈
    • 농업과학연구
    • /
    • 제28권1호
    • /
    • pp.8-17
    • /
    • 2001
  • 분얼형 옥수수 자식계통의 식물학적 특정, 유전적 거리를 조사하여 새로운 교잡종 육성을 위한 기초자료를 얻고자 실험 한 결과를 요약하면 다음과 같다. 1. 개화기에 있어서 조사된 20계통 중 K15가 가장 빨랐고 K07이 가장 늦은 개화소요일수를 보였다. 2. 간장과 착수고는 비슷한 경향으로 보며 K04가 가장컸고, K15가 가장 작은 것으로 나타났다. 3. 상관 분석 결과 분얼수는 개화기 및 출사기와 고도의 부의 상관을 보였으며, 100립중은 개화기, 이삭높이와 고도의 부의 상관을 가지고 있다. 4. RAPD 분석 결과 17개의 BAND가 나타났고 이중 1개 만이 monomolpic band를 보였으며, primer 당 평균 4개의 loci를 보였다. 5. 유전적 거리와 식물학적 특성간에는 개화기, 분얼수, 엽장과 100립중에서 관련이 있었다.

  • PDF

실내 충격소음 측정시스템 구현에 관한 연구 (A study of the measurement systems implementation for the interior impulse noise)

  • 송기혁;정성학
    • 한국컴퓨터정보학회논문지
    • /
    • 제19권6호
    • /
    • pp.93-100
    • /
    • 2014
  • 본 연구의 목적은170dB 이상의 고충격 소음원에서 실내 충격소음을 측정 평가 할 수 있는 측정시스템 구축 방법을 제안하는데 있다. 이러한 목적을 달성하기 위하여 실내충격소음 측정시스템용 시험장을 설계 및 구현하고, 충격소음 측정용 마이크로폰, Head & Torso Simulator, Ear Simulator를 구성하였다. 충격소음 측정 시 정확한 측정을 위하여 3가지 측정방법을 동시에 측정할 수 있도록 구현하였으며, 정확성과 신뢰성을 위하여 3가지의 실내충격소음 측정값을 상호 비교하였다. 3가지 측정방법에 따른 최대 음압레벨과 옥타브 밴드 결과를 비교 분석함으로써 실내 충격소음의 주파수 특성에 따른 차이점을 확인하였다. 이러한 결과는 반사파의 영향에 의한 것으로 판단된다. 이에, 시험장의 크기를 변형하면서 측정할 수 있도록 실내 충격소음 측정시스템을 구현하였다. 본 시스템 구현을 통하여, 충격 소음원의 특징분석과 해당 주파수별 스펙트럼의 반사파 영향들을 파악할 수 있을 것이며, 향후, 실내 충격소음에 대한 데이터 획득 및 분석을 위하여 유용하게 활용될 수 있을 것으로 판단된다.