• Title/Summary/Keyword: Ear-band

Search Result 34, Processing Time 0.033 seconds

Effects of the Nei-Guan Acupressure by Wrist Band on Postoperative Nausea and Vomiting after Middle Ear Surgery (손목밴드를 이용한 내관지압이 중이수술 후 오심과 구토에 미치는 효과)

  • Lee, Myung-Yun;Min, Hye-Sook
    • Journal of Korean Academy of Nursing
    • /
    • v.38 no.4
    • /
    • pp.503-512
    • /
    • 2008
  • Purpose: This study was to identify the effects of Nei-Guan accupressure using a wrist band on postoperative nausea and vomiting after middle ear surgery. Methods: The study design was a nonequivalent control group non-synchronized posttest design. Forty patients were assigned into two groups of 20 patients, the wrist band group and the control group. In the wristband group, acupressure was applied with a wrist band on the P6 point at both wrists from 30 min before to 24 hr after anesthesia. Results: The 1st hypothesis 'Applied wrist band groups will have a greater reduction in the nausea & vomiting grades by INVR than the control group' was accepted (t=2.303, p=.028). The 2nd hypothesis 'The Applied wrist band groups will have a greater reduction in the occurrence of nausea & vomiting than the control group' was partly accepted. The 3rd hypothesis 'The applied wrist band group will have a greater reduction in injection of antiemetics for 24 hr. post anesthesia than the control group' was rejected. Conclusion: Acupressure on the P6 point using a wrist band is effective to alleviate nausea for middle ear surgery patients.

development of an ear-muff with active noise control for selective noise attenuation (특정주파수 소음제거를 위한 능동소음제어식 청각보호구 개발연구)

  • Kim, Dong-Gyun;Kim, Ok-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.12
    • /
    • pp.2068-2072
    • /
    • 1997
  • Acoustic noise has become an increasingly important issue, especially in the industrial environment. Nowadays home and office are not exceptional, mainly due to the increase in the usage of machinery. Active Noise Control(ANC) becomes efficiently an available tool for the noise suppression with rapid advances of solid state electronics. In this study an ANC system is developed for audio headphone to work as a noise protector, so called an ear-muff. The system is developed to kill a certain frequency band noises selectively which is purposed to suppress only the dominant ambient noise such that normal numan conversation is not disturbed with wearing the ear-muff. For the purpose, an ANC design strategy is suggested and implemented with an analogue control circuit. The performance is evaluated by frequency response test, which shows well consistence with theoretical one. The results are so satisfactory that noise of 640 Hz, which is aimed to suppress, is reduced by 20db without significant distortion in other frequency band.

A Study on Swaging Characteristics of Band for Low Pressure Hose (저압 호스용 밴드의 체결특성에 관한 연구)

  • Kim Tyoung-Gyu;Kim Pil-Jong;Cho Seok-Beom;Kwon Boo-Kil
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.3 s.28
    • /
    • pp.32-37
    • /
    • 2005
  • Hose bands, which are used in LPG (Liquefied Petroleum Gas) or LNG (Liquefied Natural Gas) facilities for home use to join low pressure hoses with fuse-cocks (or regulators), should give a tight connection to prevent a gas leakage from hose connection parts. In this paper, hydraulic pressure tests and pull force tests were carried out to evaluate the performance and swaging length of hose bands. Experimental results showed that the swaging force of ear type bands were higher than those of spring bands and also showed that the optimal swaging length was about 1${\~}$2 mm from the hose end.

  • PDF

A Empirical Review of the Measurement Method for the Impulse Noise Using Ear Simulator (Ear Simulator를 이용한 충격소음 측정방법에 대한 고찰)

  • Song, Kee-Hyeok;Chung, Sung-Hak
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2014.01a
    • /
    • pp.425-426
    • /
    • 2014
  • 충격소음(Impulse Noise) 측정 시 지그(Ear Simulator)가 자체적으로 음압측정에 미치는 영향을 확인하기 위해 지그를 이용하여 실내에서 충격소음을 측정하였다. 측정의 신뢰성과 정확성을 확보하기 위해 마이크로폰과 지그에서 동일조건에서 동시에 데이터를 수집하였다. 추가로 헤드&토르소에서 실험을 실시하였다. 최대음압레벨과 1/3옥타브 밴드 결과를 비교분석함으로써 측정 방법에 따른 차이점을 발견하였다.

  • PDF

Finite Element Analysis of Sound Transfer Characteristics for Middle Ear (유한요소 모델을 이용한 중이의 소리전달 특성 해석)

  • Gal, Young-Min;Baek, Moo-Jin;Lee, Doo-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.12
    • /
    • pp.1563-1571
    • /
    • 2011
  • In this study, we developed a finite element model of the human middle ear has been developed to calculate itsfor sound transfer characteristics calculation. We usedThe geometric data forof ossicles, obtained byfrom micro-CT scanning, was used in order to develop the middle- ear FE model. A right- side temporal bone of a Korean cadaver was used for the micro-CT scanning. The developed FE model includes three ossicles, the tympanic membrane, ligaments, and muscles. We calculated theA sound transfer function from the tympanic membrane to the stapes footplate was calculated. The sound transfer function calculated vias of the FE model shows good agreement with measured responses over the 10- kHz frequency band. To measureidentify the sensitivityies of the middle- ear function due to material property variation, we studied several parameters studies have been fulfilled using the middle ear FE model. TAs a result the stiffness property of the incudostapedial joint had the greatest influence onwas the most influential to the middle- ear sound transfer function among the parameters.

A Real-time Tinnitus Treatment System Using Tinnitus Frequency Removal and Adjacent Frequency Amplification on Mobile Device

  • Park, Dae-Hyun;Kim, Yoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.11
    • /
    • pp.111-118
    • /
    • 2015
  • In this paper, we propose a new tinnitus treatment system that removes the frequency band where the ear noises is generated and amplifies the around frequency bands in order to treat a nonstop buzzing in the ears, that is one among the disease commonly generated in modern people. Mostly the tinnitus is generated by the tunability with the neighboring nerves while the part of the cerebral cortex which is unable to react to the stimuli by the sound of the specific frequency band reacts to other frequency band. Therefore, the excitability activity by the tunability of the cerebral cortex is suppressed and the remedial value is gotten by removing the tinnitus frequency band, and the around frequency bands are amplified to strengthen the remedial value. Experimental results show that the tinnitus can be treated conveniently if the patients use the android application which the proposed technique is applied to.

A New Hearing Aid Algorithm for Speech Discrimination using ICA and Multi-band Loudness Compensation

  • Lee Sangmin;Won Jong Ho;Park Hyung Min;Hong Sung Hwa;Kim In Young;Kim Sun I.
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.3
    • /
    • pp.177-184
    • /
    • 2005
  • In this paper, we proposed a new hearing aid algorithm to improve SNR(signal to noise ratio) of noisy speech signal and speech perception. The proposed hearing aid algorithm is a multi-band loudness compensation based independent component analysis (ICA). The proposed algorithm was compared with a conventional spectral subtraction algorithm on behind-the-ear type hearing aid. The proposed algorithm successfully separated a target speech signal from background noise and from a mixture of the speech signals. The algorithms were compared each other by means of SNR. The average improvement of SNR by ICA based algorithm was 16.64dB, whereas spectral subtraction algorithm was 8.67dB. From the clinical tests, we concluded that our proposed algorithm would help hearing aid user to hear clearly a target speech in noisy conditions.

Isozymic Characteristics of Multiple-Ear and Tiller Maize Lines (다수다얼성 옥수수의 동위효소 특성)

  • ;Bong-Ho Chae
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.32 no.1
    • /
    • pp.16-23
    • /
    • 1987
  • This experiment was conducted to determine the isozymic differences between normal maize and maize inbreds of multiple ears and tillers (MET). Two maize inbreds Euisung, Iri and their hybrid having tillers and multiple ears were compared with normal maize. With usual electrophoresis using 6% polyacrylamide gel, peroxidase and esterase enzymes were studied. Matured leaf, culm, leaf sheath, root and young ear tissues showed different isozymic patterns between METs and normal maize in peroxidase. The Euisung inbred grown for 7 days under dark condition showed typical peroxidase. bands compared with checks in the tissues of coleoptile and stele. Better observation of isozymic bands was made during early part of maize growth. Parental inbreds showed more active and apparent band differences than their hybrids in esterase. Bands for esterase were also apparently different in the stele, coleoptile and young ear tissues of the METs and the checks. The maize lines infected with black streaked dwarf virus showed obvious differences in peroxidase and esterase isozymes.

  • PDF

Relationship with botanical characteristics and RAPD analysis of maize inbred lines with tillers (분얼형 옥수수의 식물학적 특성과 RAPD 분석에 의한 근연관계)

  • Kim, Chol-Min;Lee, Hee-Bong;Choi, Hyun-Gu;Jung, Jae-Young;Kim, Gi-Hoon
    • Korean Journal of Agricultural Science
    • /
    • v.28 no.1
    • /
    • pp.8-17
    • /
    • 2001
  • This study was carried out to obtain a basic intonation for the development of a new com hybird with tillers. Materials used in this study were 20 lines having three to four tillers per plant including the PI213749 U.S. line with non-tillers. These 20 lines were compared for the botanical characteristics and genetic distances were measured using RAPD analysis. Flowering date of the K15 was very earlier, while the K07 was very late in flowering date. Stem height and ear height were similar except for K04 and the K15. K06, K13 and K19 lines were appeared to be resistant to lodging due to decreased ear height. Number of tillers per plant of lines used were shown three to five on average. K09 showed the highest kernel yield, while the K08 was low. Among characteristics measured tiller per plant and flowering dates, and silking dates showed a positive correlation, while 100 kernels weight, flowering date and ear height were shown a negative with tillers per plant. A total of 17 bands by RAPD analysis using four per primer were appeared and these lines were classified into three groups, especially the third group could be classified into of four sub-groups.

  • PDF

A study of the measurement systems implementation for the interior impulse noise (실내 충격소음 측정시스템 구현에 관한 연구)

  • Song, Kee-Hyeok;Chung, Sung-Hak
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.6
    • /
    • pp.93-100
    • /
    • 2014
  • The objective of this study is to propose the measurement system implementation method for the evaluation and measurement of the indoor-impulsive over 170 dB noise source. For the purpose of measuring impulse noise, design and implementation constructed followed subsystems of the testing center, microphone, ear simulator, head and torso simulator and so on. Measurement systems for the accuracy and reliability of impulse noise are implemented when measuring 3 ways of measurements method by the simultaneous measurement system design. For the accuracy and reliability of three mutually indoor-impulse noise measurements were compared, three kinds of measuring methods in accordance with the peak sound pressure level and octave band. Comparing the results of data, the indoor-impulse noise by analyzing a frequency characteristic was validated in difference for the statistical significance. Result are determined by the influence of the reflected wave. Therefore, the flexible size of the interior test site while interior impulse noise measurement system was constructed. Throughout this system can be affected by parameters that are the impulse noise source and the corresponding frequency-characteristic analysis to determine the spectrum of the reflected wave. And, in the near future, indoor impulse noise measurement systems for acquisition and analysis are utilized in useful data.