• Title/Summary/Keyword: EVAPORATION

Search Result 3,553, Processing Time 0.029 seconds

Atmospheric Characteristics of Fog Incidents at the Nakdong River : Case Study in Gangjeong-Goryeong Weir (낙동강 유역 안개 발생시 기상 특성: 강정고령보 사례를 중심으로)

  • Park, Jun Sang;Lim, Yun-Kyu;Kim, Kyu Rang;Cho, Changbum;Jang, Jun Yeong;Kang, Misun;Kim, Baek-Jo
    • Journal of Environmental Science International
    • /
    • v.24 no.5
    • /
    • pp.657-670
    • /
    • 2015
  • Visibility and Automatic Weather System(AWS) data near Nakdong river were analyzed to characterize fog formation during 2012-2013. The temperature was lower than its nearby city - Daegu, whereas the humidity was higher than the city. 157 fog events were observed in total during the 2 year period. About 65% of the events occurred in fall (September, October, and November) followed by winter, summer, and spring. 94 early morning fog events of longer than 30 minutes occurred when south westerly wind speed was lower than 2 m/s. During these events, the water temperature was highest followed by soil surface and air temperatures due to the advection of cold and humid air from nearby hill. The observed fog events were categorized using a fog-type classification algorithm, which used surface cooling, wind speed threshold, rate of change of air temperature and dew point temperature. As a result, frontal fog observed 6 times, radiation 4, advection 13, and evaporation 66. The evaporation fog in the study area lasted longer than other reports. It is due to the interactions of cold air drainage flow and warm surface in addition to the evaporation from the water surface. In particular, more than 60% of the evaporation fog events were accompanied with cold air flows over the wet and warm surface. Therefore, it is needed for the identification of the inland fog mechanism to evaluate the impacts of nearby topography and land cover as well as water body.

Effect of Defect Energy levels on the AC PDP Discharging Characteristics (MgO 보호막의 결함 전위 레벨이 AC-PDP 방전 특성에 미치는 효과)

  • Kwon, Sang-Jik;Kim, Yong-Jae;Cho, Eou-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.12
    • /
    • pp.12-17
    • /
    • 2007
  • The effects of the evaporation rate of MgO films using an electron beam on the MgO properties and the discharge characteristics of a plasma display panel(PDP) were investigated and analyzed. Mgo films were deposited with the various MgO evaporation rates. The MgO properties such as the crystal orientation, the surface roughness, and the film structure, were inspected using XRD(X-ray diffractometry), AFM(atomic force microscopy). From the experiments and Paschen law, the maximum value of the secondary, electron emission coefficient $(\gamma)$ was obtained at the evaporation rate of $5\AA/sec$. The minimum firing voltage and the maximum luminous efficiency were obtained at an evaporation rate of $5\AA/sec$. In the MgO film deposited at $5\AA/sec$, the (200) orientation and $F^+$ center were most intensive. The XRD results and cathode-luminescence(CL) spectra show the $\gamma$ values are correlated with $F/F^+$ centers of the molecular structure of MgO films.

Performance Characteristics of R744 OTEC Power Cycle with Operation Parameters (운전조건에 따른 R744용 해양온도차 발전 사이클의 성능 특성)

  • Yoon, Jung-In;Son, Chang-Hyo;Baek, Seung-Moon;Kim, Hyeon-Ju;Lee, Ho-Saeng
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.5
    • /
    • pp.580-585
    • /
    • 2012
  • In this paper, the cycle performance analysis for condensation and evaporation capacity, total work and efficiency of ocean thermal energy conversion power system using R744 ($CO_2$) is presented to offer the basic design data for the operating parameters of this system. The operating parameters considered in this study include superheating and subcooling degree, evaporation and condensation temperature, pump and turbine efficiency. The main results were summarized as follows : The evaporation capacity of R744 increases with superheating and subcooling degree, but decreases with the increasing condensation temperature. The total work increases with superheating and subcooling degree of R744, but decreases with the increasing evaporating temperature. And, the efficiency increases with subcooling and superheating degree, but decreases with the increasing condensation temperature. Therefore, superheating and subcooling degree, evaporation and condensation temperature and pump and turbine efficiency of R744 OTEC power system have an effect on the evaporation and condensation capacity, total work and efficiency of this system. With a thorough grasp of these effect, it is necessary to design the OTEC power cycle using R744.

Simulation of Soil Hydrological Components in Chuncheon over 30 years Using E-DiGOR Model

  • Aydin, Mehmet;Jung, Yeong-Sang;Yang, Jae-E.;Lee, Hyun-Il;Kim, Kyung-Dae
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.4
    • /
    • pp.484-491
    • /
    • 2012
  • The hydrological components of a sandy loam soil of nearly level in Chuncheon over 30 years were computed using the E-DiGOR model. Daily simulations were carried out for each year during the period of 1980 to 2009 using standard climate data. Reference evapotranspiration and potential soil evaporation based on Penman-Montheith model were higher during May to August because of the higher atmospheric evaporative demand. Actual soil evaporation was mainly found to be a function of the amount and timing of rainfall, and presumably soil wetness in addition to atmospheric demand. Drainage was affected by rainfall and increased with a higher amount of precipitation and soil water content. Excess drainage occurred throughout rainy months (from July to September), with a peak in July. Therefore, leaching may be a serious problem in the soils all through these months. The 30-year average annual reference evapotranspiration and potential soil evaporation were 951.5 mm and 714.2 mm, respectively. The actual evaporation from bare soil varied between 396.9-528.4 mm and showed comparatively lesser inter-annual variations than drainage. Annual drainage rates below 120 cm soil depth ranged from 477.8 to 1565.9 mm. The long-term mean annual drainage-loss was approximately two times higher than actual soil evaporation.

Simulation Study on the Thickness Uniformity of Thin Film Deposited on a Large-Size Substrate in Multi-Source Evaporation System (다중소스 진공증착법에서의 대면적 박막균일도에 관한 전산모사 연구)

  • Kim, Chang-Gyu;Lee, Won-Jong
    • Korean Journal of Materials Research
    • /
    • v.21 no.1
    • /
    • pp.56-66
    • /
    • 2011
  • Multi-source evaporation is one of the methods to improve the thickness uniformity of thin films deposited by evaporation. In this study, a simulator for the relative thickness profile of a thin film deposited by a multi-source evaporation system was developed. Using this simulator, the relative thickness profiles of the evaporated thin films were simulated under various conditions, such as the number and arrangements of sources and source-to-substrate distance. The optimum conditions, in which the thickness uniformity is minimized, and the corresponding efficiency, were obtained. The substrate was a 5th generation substrate (dimensions of 1300 mm ${\times}$ 1100 mm). The number of sources and source-to-substrate distance were varied from 1 to 6 and 0 to the length of the major axis of the substrate (1300 mm), respectively. When the source plane, the area on which sources can be located, is limited to the substrate dimension, the minimum thickness uniformity, obtained when the number of sources is 6, was 3.3%; the corresponding efficiency was 16.6%. When the dimension of the source plane is enlarged two times, the thickness uniformity is remarkably improved while the efficiency is decreased. The minimum thickness uniformity, obtained when the number of sources is 6, was 0.5%; the corresponding efficiency was decreased to 9.1%. The expansion of the source plane brings about not only the improvement of the thickness uniformity, but also a decrement of the efficiency and an enlargement of equipment.

Synthesis and Properties of Ba(Ti,Sn)O3 Films by E-Beam Evaporation (전자빔증발법에 의한 Ba(Ti,Sn)O3막의 제조 및 특성)

  • Park, Sang-Shik
    • Korean Journal of Materials Research
    • /
    • v.18 no.7
    • /
    • pp.373-378
    • /
    • 2008
  • $Ba(Ti,Sn)O_3$ thin films, for use as dielectrics for MLCCs, were grown from Sn doped BaTiO3 sources by e-beam evaporation. The crystalline phase, microstructure, dielectric and electrical properties of films were investigated as a function of the (Ti+Sn)/Ba ratio. When $BaTiO_3$ sources doped with $20{\sim}50\;mol%$ of Sn were evaporated, $BaSnO_3$films were grown due to the higher vapor pressure of Ba and Sn than of Ti. However, it was possible to grow the $Ba(Ti,Sn)O_3$ thin films with {\leq}\;15\;mol%$ of Sn by co-evaporation of BTS and Ti metal sources. The (Ti+Sn)/Ba and Sn/Ti ratio affected the microstructure and surface roughness of films and the dielectric constant increased with increasing Sn content. The dielectric constant and dissipation factor of $Ba(Ti,Sn)O_3$ thin films with {\leq}\;15\;mol%$ of Sn showed the range of 120 to 160 and $2.5{\sim}5.5%$ at 1 KHz, respectively. The leakage current density of films was order of the $10^{-9}{\sim}10^{-8}A/cm^2$ at 300 KV/cm. The research results showed that it was feasible to grow the $Ba(Ti,Sn)O_3$ thin films as dielectrics for MLCCs by an e-beam evaporation technique.

A Study on the thermal Kinetics for Disposal of Sewage Sludge Using Thermal Wind Drying of One mechanical Power (ONE구동 열풍건조시스템을 이용한 하수슬러지 감량화를 위한 열적거동 연구)

  • Bae, Hae-Ryong;Ha, Sang-An
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.13 no.2
    • /
    • pp.74-84
    • /
    • 2005
  • The objectives of this study was to investigate the improvement of thermal kinetics for disposal of sewage sludge using thermal wind drying. The operational parameters varied are the temperature of $130{\sim}170^{\circ}C$ and evaporation velocity WD. Important parameters effect on thermal kinetics for evaporation of water in sewage sludge studied include the drying time, water content of sewage sludge, solids amount of sewage sludge(TS%) by the varied temperature. The saturation point of water evaporation was observed at the drying time of 60 min in conditions of drying temperature $170^{\circ}C$ and drying time of 120 min by drying temperature $130^{\circ}C$ and WD=0.95 m/s. Operation at drying temperature of $170^{\circ}C$ led to higher rate of evaporation than those 130, $150^{\circ}C$ at WD=1.0 m/s and WD=1.0 m/s was higher than WD=0.5 m/s at drying temperature of $130^{\circ}C$.

  • PDF

The Jang suk-sun's explanation and clinical application about liver (장석순의 간에 대한 천발과 임상응용)

  • 김진옥;김용진
    • The Journal of Korean Medicine
    • /
    • v.25 no.1
    • /
    • pp.85-95
    • /
    • 2004
  • The theory of liver by Jang suk-sun[張錫純] is that first, although liver exists at right side of body and spleen at left anatomically, function of liver presents at left side of body and function of spleen at right based on principle of 'interdependence between eum and yang' and 'join strength with elasticity', and in the relation between liver and spleen, if gi of spleen ascends, gi of liver also ascends, and if gi of stomach descents, gi of gall bladder also descents. So. care of spleen and stomach becomes main point in treating disease of liver. The meaning of 'the liver being in charge of the evaporation'[肝主氣化] is that first, it raises the primordial gi and forms the 'great g' for it's circulation of whole body. Second., it excretes the functional activity of gi and connects heart with kidney and guides the evaporation of the whole body by connecting innate nature with acquired nature. Third, 'the liver being in charge of the evaporation' is realized by the help of spleen and stomach. And he said that this functional activity of gi is one of distinctive features that distinguish Oriental medicine from Western medicine. He discoursed upon physiology of 'the liver being in charge of the evaporation' and 'the Body belonged to yin and the Use belonged to yang' after seeing an evil of abusing drugs that calm the liver and check hyperfunction of liver by contemporary doctors. And he established a treat of 'warming and recuperating the gi of liver' [溫補肝氣法] and used it for symptoms of 'deficiency of liver-gi'[肝氣虛], 'exhaution of liver-gi'[肝氣脫], and 'the liver-cold'[肝寒證].

  • PDF

Study of large-area CIGS thin film solar cell (CIGS 박막 태양전지의 대면적화 연구)

  • Kim, Chae-Woong;Kim, Dae-Sung;Kim, Tae-Sung;Kim, Jin-Hyeok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.399-399
    • /
    • 2009
  • CIS계 화합물 태양전지는 높은 광흡수계수와 열적 안정성 및 Ga 조성 조절을 통한 밴드갭 조절이 용이해 고효율 박막 태양전지로 각광 받고 있다. CIS 태양전지의 광 흡수층 제조 방법으로는 여러 가지 방법이 있지만 본 연구에서는 가장 높은 에너지 변환 효율을 달성한 Co-Evaporation 방법을 사용하기로 하였다. 미국의 NREL의 경우 Co-Evaporation 방법을 사용해 20%의 에너지 변환 효율을 달성한 바가 있다. 하지만 이러한 효율의 태양전지는 실험실에서 연구용으로 제작한 아주 작은 면적으로 태양전지 양산화에 그대로 적용하기는 힘들다. 따라서 CIGS 태양전지의 양산화 적용을 위해 대면적화가 필수적이다. 본 연구에서는 기존의 3 stage 방식을 이용해 광흡수층을 증착하여 최적화 조건을 연구하였다. 또한 기판의 면적 증가에 따라 효율과 Voc, Jsc, F.F가 얼마나 감소하는지 실험하여 보았다. 기판은 soda lime glass를 사용 하였으며 후면 전극으로 약$1{\mu}m$ 두께의 Mo를 DC Supptering 방법을 이용해 증착하였다. 다음으로 약 $2{\mu}m$이상의 광흡수층을 Co-Evaporation 방법을 이용하여 증착 하였으며 buffer층으로는 약 50nm의 CdS층을 CBD방법을 이용하여 제조 하였다. TCO층으로 약 50nm의 i-ZnO와 약 450nm의 Al-ZnO를 RF Sputtering 방법을 이용하여 증착 하였다. 마지막으로 앞면 전극으로 약 $3{\mu}m$의 Al을 Thermal Evaporation 방법으로 증착하였다. 태양전지 소자의 면적은 $0.49cm^2$, $25cm^2$, $100cm^2$로 각각 면적을 달리하며 효율을 비교 분석하였다.

  • PDF

Evaporation Heat Transfer and Pressure Drop Characteristics of Refrigerant R-22 in a P1ate and Shell Heat Exchanger (Plate and Shell 열교환기내의 R-22 증발열전달 및 압력강하 특성에 관한 실험적 연구)

  • Seo, Mu-Gyo;Park, Jae-Hong;Kim, Yeong-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.10
    • /
    • pp.1318-1326
    • /
    • 2001
  • The evaporation heat transfer coefficient and pressure drop for refrigerant R-22 flowing in the plate and shell heat exchanger were investigated experimentally in this study. Two vertical counterflow channels were farmed in the exchanger by three plates of commercial geometry with a corrugated trapezoid shape of a chevron angel of 45 ° Upflow boiling of refrigerant R-22 in one channel receives heat from the hot downf1ow of water in the other channel. The effects of the mean vapor quality, mass flux, heat flux and pressure of R-22 on the evaporation heat transfer and pressure drop were explored. The quality change of R-22 between the inlet and outlet of the refrigerant channel ranges from 0.03 to 0.05. The present data showed that both the evaporation heat transfer coefficient and pressure drop increase with the vapor quality. At a higher mass flux, the evaporation heat transfer coefficient and pressure drop are higher for the entire range of the vapor quality Raising the imposed wall heat flux was found to slightly improve the heat transfer, while at a higher refrigerant pressure, both the heat transfer and pressure drop are slightly lower.