• Title/Summary/Keyword: ESS 제어

Search Result 144, Processing Time 0.026 seconds

Design of Smart Plug based Media Platform interlocking with ESS (ESS 연동형 스마트 플러그 기반의 미디어 플랫폼 설계)

  • Kang, Mingoo
    • Smart Media Journal
    • /
    • v.3 no.2
    • /
    • pp.37-42
    • /
    • 2014
  • In this paper, the function design of smart media platform control with smart monitoring, and displaying modules which have the priorities of smart plug based smart outlet, is proposed for electrical suppliance of essential information appliance in emergency power consumption situation(blackout, peaktime etc). The effect of power management will be maximized by this smart gateway interlocking with ESS(energy storage system) which has bi-directional power transmission control modules, and smart outlet based on the priority control actions.

A Study on High Voltage SMPS for Controller of the ESS (ESS 제어기용 고압 SMPS에 관한 연구)

  • Jin, Jiao;Kim, Soo-Yeon;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.428-429
    • /
    • 2019
  • 본 논문은 ESS나, 고압 DC 전압을 입력으로 받아 주변 제어기 제어보드의 전력을 공급하기 위한 새로운 고압 SMPS 토포로지를 제안하였다. 본 논문에서 제안하는 고압 SMPS의 사양은 최근 고압화 추세인 ESS 전압을 허용할 수 있는 최대 입력전압이 1800[V]이며 출력전압이 24[V]이다. 제안된 토포로지는 단일 고압 전력 소자 사용의 경제성을 극복하기 위해 분활 콘덴서를 이용한 전압 분배 형태로 구성하고, 전압의 동일한 분배를 위해 포워드 컨버터를 사용하였다. 제안된 토포로지를 PSIM에서 시뮬레이션 하여 타당성을 검증하였다.

  • PDF

A Study on the Method of Energy Saving in a Marine Cooling System (선박 냉각시스템의 에너지 절감기법에 관한 연구)

  • Oh Jin-Seok;Lim Myoung-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.587-592
    • /
    • 2005
  • The ESS(Energy Saving System) is designed to have functions of controlling. monitoring for cooling system. etc. ESS consists of the I/O module, CPU module and Display module I/O module detects various ESS data on local area and treats signals via I/O interface system. The interface system receives various status data and outputs control signals. ESS is tested with dummy signal to verify proposed functions and is shown good results. For future study ESS will be tested under real condition in the ship.

Efficient Grid-Independent ESS Control System by Prediction of Energy Production Consumption (에너지 생산량 소비량 예측을 통한 효율적인 계통 독립형 ESS 제어 시스템)

  • Joo, Jong-Yul;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.1
    • /
    • pp.155-160
    • /
    • 2019
  • In this paper, we propose an efficient grid-independent ESS control system through the control of renewable energy and agricultural ICT by utilizing the prediction of energy production and consumption. The proposed system is an integrated management system that can perform maintenance and monitoring by visualizing the accurate phase and data of power system. It can automatically cope, collect, process, and control the data. Also, it can analyze the power generation of solar power generation, consumption pattern of installed facilities, and operation trend of facilities. Further, it can predict the consumption of energy production and present the optimal energy management method by using the OpenAPI of the Korea Meteorological Administration, thereby reducing unnecessary energy consumption and operating cost.

Suggestion of Logic to Control Power Plant Equipped ESS in case of Full Open Turbine Control Valve (ESS를 이용한 발전소 터빈제어밸브 전개 운전 제어로직 제안)

  • In Young Chung;Jae-Heon Lee
    • Plant Journal
    • /
    • v.18 no.4
    • /
    • pp.66-72
    • /
    • 2023
  • In order to respond to the demand for flexible operation of thermal power generation, development of natural sliding pressure operation that minimizes throttle loss by opening the turbine control valve 100% and maximize power generation efficiency in conjunction with ESS in order to quickly respond to fluctuations in the system frequency is required. The logic development of natural sliding pressure operation with ESS was developed to modify the existing logic at the power plant's top-level control logic such as the unit master, the boiler master and the turbine master. Cooperative control algorithms that complement the advantages and disadvantages of ESS operation (quick response, limited capacity) and power plant operation (slow response, continuous operation) not only improve efficiency when applied to actual power plants, but also respond quickly and flexibly to load demands to ensure system stability.

  • PDF

A study on the topology and control method of Solar Hybrid Energy Storage System (태양광-ESS 하이브리드시스템의 토폴로지 및 제어방법에 대한 연구)

  • Kim, JongHoe;Lee, KyungSoo
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.168-170
    • /
    • 2018
  • 소규모 신재생에너지 시스템의 보급 확산과 자가발전 시스템 시장이 확대됨에 따라 친환경 에너지저장시스템(ESS, Energy Storage System)에 대한 기술 요구가 증대되고 있다. 특히 전력변환장치인 컨버터와 인버터에서 발생하는 손실은 무시할 수 없다. 본 논문에서는 태양광-ESS 하이브리드시스템 토폴로지와 제어방법의 특징 및 차이점에 대하여 시뮬레이션을 통한 분석을 진행 하였다.

  • PDF

Development of Operation and Control Technology of Energy Storage System for Frequency Regulation and Operation by Grid Connected Automatic Control (주파수조정용 에너지저장장치 운전제어 기술의 개발과 계통연계 자동제어 운전)

  • Lim, Geon-Pyo;Choi, Yo-Han;Im, Ji-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.4
    • /
    • pp.235-241
    • /
    • 2016
  • Grid-connected, large-capacity energy storage systems (ESS) can be used for peak load supply, frequency regulation, and renewable energy output smoothing. In order to confirm the capability of battery ESS to provide such services, 4MW/ 8MWh battery ESS demonstration facility was built in the Jocheon substation on Jeju Island. The frequency regulation technology developed for the Jocheon demonstration facility then became the basis for the 28MW and 24MW frequency regulation ESS facilities installed in 2014 at the Seo-Anseong and Shin-Yongin substations, respectively. The operation control systems at these two facilities were continuously improved, and their successful commercialization led to the construction of additional ESS facilities all over Korea in 2015. In seven (7) locations nationwide (e.g., Shin-Gimje and Shin-Gyeryeong), a total of 184 MW of ESS had been commercialized in 2016. The trial run for the new ESS facilities had been completed between April and May in 2016. In this paper, results of the trial run from each of the ESS facilities are presented. The results obtained from the Seo-Anseong and Shin-Yongin substations during a transient event by a nuclear power plant trip are also presented in this paper. The results show that the frequency regulation battery ESS facilities were able to quickly respond to the transient event and trial run of ESS is necessary before it is commercialized.

Development of Energy Storage System Monitoring for electric peak load control based on CAN protocol (전력피크부하제어를 위한 CAN 기반 ESS 모니터링 시스템 개발)

  • Meang, Boyeon;Park, Jaeshin;Park, Jongtae;Lee, Seungwon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2014.04a
    • /
    • pp.135-137
    • /
    • 2014
  • 최근 공공건물, 중대형 건물 등에서 전력 피크 시간대에 또는 안정적인 전력공급을 위해 사용할 에너지를 저장하는 방법으로 ESS 를 채택하고 있다. 그러나 대부분의 ESS 의 상태를 모니터링하기 위해서는 별도의 PC 에 소프트웨어를 설치하거나, EMS(Energy Management System)와 같은 별도의 솔루션의 한 기능으로 확인할 수 있다. 이럴 경우, 소프트웨어가 설치되어 있지 않은 현장에서 확인이 어렵고, 자연방전이 일어난 경우 과방전의 가능성도 배제할 수 없다. 따라서 ESS 의 랙 내부에 LCD 화면을 탑재하여 ESS 독립적으로도 상태를 확인할 수 있도록 모니터링 시스템을 개발하였다. 본 연구의 ESS 모니터링 시스템은 ESS 의 안전성올 높이고, 보다 직관적으로 ESS 의 상태를 확인할 수 있도록 구현 하였다.

A Study on the Off-Grid Photovoltaic Generation System with Sequential Voltage System (순차전압시스템을 고려한 독립형 태양광 발전 시스템에 관한 연구)

  • Kim, Gu-Yong;Bae, Jun-Hyung;Kim, Jong-Hae
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.364-367
    • /
    • 2020
  • This paper presents the off-grid PV-ESS system of sequential voltage control method applied to OR logic gate. The conventional off-grid PV-ESS system with the low-voltage series connection has problems due to capacity expansion. To solve these problems, this paper proposes a noble PV-ESS system with high efficiency and low cost by applying sequential voltage control technique of the high-voltage series connection of analog circuit type. The input voltage of DC to AC inverter can be converted from the low-voltage by the combinations of series connection of the conventional cascaded 24V solar cell unit modules to the high-voltage of 384V in battery. The output voltage of the battery was 384V as the each input voltage of three phase DC to AC inverter, and the each output voltage of three phase 10kW DC to AC inverter is designed to be AC380V@60Hz as the line to line rms voltage value. To prove the validity of the theoretical analysis by PSIM simulation, the operating characteristics of sequential voltage control system with OR logic gate were confirmed through experiment results.

A Study on the Energy Saving Method by controlling Capacity of Sea Water Pump in Central Cooling System for Vessel (선박용 중앙냉각시스템의 해수 펌프 용량조절에 따른 에너지 절감 기법에 관한 연구)

  • Lee, Ji-Young;Yoo, Heui-Han;Kim, Yun-Hyung;Oh, Jin-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.592-598
    • /
    • 2007
  • The fuel charge is getting higher in navigation cost. Therefore, shipowners try to find the method for reducing oil consumption. ESS(Energy Saving System) is one of he method. ESS is the system consisted with two inverters, ESS control unit and monitoring system. Two inverters control two main sea water cooling pumps. In the ESS control Unit, the control algorithm finds optimized point to decrease a power consumption of main sea water cooling pumps. Monitoring system observes ESS not to work improperly. ESS is experimented in the laboratory with real condition and analyzed in every view. After experiment, the result of the experiment shows that the control algorithm works correctly and safely. ESS has a plan to be operated in the ship soon. In that case, additional devices are needed to connect ESS with cooling system of the vessel. So the development of addition device is needed and being studied.