• Title/Summary/Keyword: ESP

Search Result 466, Processing Time 0.032 seconds

Comparison of particle collection characteristics in a wire-cylindrical wet electrostatic precipitator with and without a water film (와이어-실린더형 습식 전기집진기의 수막 유무에 따른 집진 특성 비교)

  • Woo, Chang Gyu;Cho, Won Ki;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.89-95
    • /
    • 2018
  • People's environmental concerns for fine particles in Korea lead to the strong necessity of improving the performance of environmental control systems. Wet electrostatic precipitators (ESPs) are considered as one of the alternatives to overcome the limit of previous dry ESPs, the re-entrainment of collected particles during rapping and back corona problem for high electrical resistivity dusts etc. In this study, a wire-cylindrical ESP with a thin water film has been developed. Particle collection characteristics were compared in the ESP with operations of water film on and off. Particle collection efficiencies at various applied voltages as well as voltage-current curves were almost the same in the ESP with and without a water film. Particle collection performance for PM1.0, PM2.5 and PM10 in the wet ESP with a water film was constantly maintained with operation time even in the high dust loading environment. This results indicate that a uniform water film in our wet ESP was successfully formed with a very thin layer without any dry spot and therefore could continuously clean the collected particles on the inner wall of the ESP without any performance degradation.

Short-term streamflow Prediction Using ESP Method in Gumho River Basin (ESP 기법을 적용한 금호강유역의 단기 유량예측)

  • Choi, Hyun Gu;Lee, Eul Rae;Kang, Sin Uk;Lee, Sang Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.411-411
    • /
    • 2015
  • 유량예측의 가장 주된 목적은 가뭄과 홍수와 같은 수해방지를 위해 통합수자원관리를 수행하는데 있다. 이런 유량예측을 위해 다양한 기법들로 예측이 수행되고 있으며, 예측기간과 필요 정확도에 따라 초단기, 단기, 중 장기 예측 등으로 구분할 수 있다. 유량예측에 사용되는 기법들은 기후변화 시나리오와 같이 예측된 강우자료를 이용하여 유출량을 예측하는 방법이 있으며, 통계적인 방법으로 과거자료들을 활용하여 미래의 유량을 예측하는 방법이 있다. 본 연구에서는 ESP 기법을 이용하여 금호강 유역의 월 단위(30일) 유량을 예측하고자 한다. 앙상블 유량예측기법(ESP; Ensemble Streamflow Prediction)이란 현재의 유역상태를 초기조건으로 사용하고 과거의 온도나 강수 등의 시계열 앙상블을 강우-유출모형에 입력하여 유출량을 앙상블로 예측하는 기법이다. ESP는 결국 현재의 유역상태와 유역에서의 과거 강우 관측기록, 미래 강우예측에 대한 정보를 조합하여 그에 따른 유출 앙상블을 생산해내게 된다. 월 유량을 예측하기 위해서 금호강 유역의 1988년에서 2014년까지 27년간 대구, 영천, 포항 관측소의 기상자료를 수집하였으며, 금호강 표준유역에 해당하는 19개 유역으로 분할하여 모의에 이용하였다. 금호강 유역에 티센망을 적용하여 각 표준유역별로 강우량을 조합하여 2013년까지 모의에 적용하였으며, 이는 과거자료로 사용하였다. 유량예측에 사용되는 강우자료를 생성하기 위해서 26년간 일강우를 이용하였다. 예를 들어 2014년 12월을 예측한다면 11월까지 관측된 유역초기 조건을 가지는 수문모형의 12월 기상입력자료로써 현재 유역에서 발생 가능성이 있는 동일 유역의 과거 1988년부터 2013년까지의 12월 기상자료들을 사용하는 방법이다. 1988년부터 2013년까지 26개 12월 기상자료를 사용하므로 유량예측결과 또한 26개가 주워진다. 계산된 26개의 유량앙상블이 적용된 유역에서 12월에 발생 가능한 유출량의 모음이 된다. 시나리오결과를 수자원관리에 활용하기 위해서 초과확률로 분석하였으며, 이런 분석의 결과는 향후 가뭄과 홍수 같은 수해방지를 위해 수공구조물의 운영에도 활용할 수 있을 것으로 판단된다.

  • PDF

Association Between Vertebrobasilar Insufficiency and Cervicogenic Headache: Hypothetical Approach Towards Etiopathogenesis of Headache

  • Kaur, Aninditya;Rakesh, N.;Reddy, Sujatha S.;Thomas, Nithin;Nagi, Ravleen;Patil, Deepa Jatti
    • Journal of Oral Medicine and Pain
    • /
    • v.45 no.4
    • /
    • pp.97-109
    • /
    • 2020
  • Purpose: Cervicogenic headache (CGH) is pain referred to the head/ face from the structures in vicinity of upper cervical spinal nerves via trigeminocervical pathway. Ponticulus Posticus (PP) and Elongated Styloid Process (ESP) are anatomical structures that cause compression of vasculature present around upper cervical nerve plexus. Recently, computational fluid dynamics (CFD) has shown to play an essential role in identification of these high-pressure zones in the brain. The aim of this research is to study the association of ESP and PP in patients with CGH and to develop a hypothesis by CFD to analyse vertebrobasilar insufficiency as a contributing factor in occurrence of CGH. Methods: Retrospective analysis of 4500 full skull CBCT scans was done for the presence of partial or complete PP and length of Styloid Process (SP). Research was divided into two phases; In first Preliminary Phase, 150 scans that showed the presence of PP and ESP were analysed, and only 134 patients gave consent to fill the questionnaire containing 96 question items pertaining to symptoms associated with CGH. In the second phase, simulation of Vertebral and Carotid Artery was done using Fluent 14.5 Software and by CFD, pressure distribution on arteries was obtained that helped to identify high pressure regions. Results: Both PP and ESP showed a statistically significant association with CGH (p<0.001). By CFD analysis, both steady and transient phases of simulation showed drop in pressure due to constriction of internal carotid and vertebral artery by ESP and PP respectively and were found to decrease the volume of blood reaching the brain, 0.12 /0.13 mL and 0.06 mL respectively. Conclusions: Our analysis proves ESP and PP as contributing factors towards CGH. Hence for proper diagnosis and management of headache disorders, clinicians should have adequate knowledge about these anatomical structures and their resulting clinical symptoms.

Value of Ensemble Streamflow Forecasts for Reservoir Operations during the Drawdown Period (이수기 저수지 운영을 위한 앙상블 유량예측의 효용성)

  • Eum, Hyung-Il;Ko, Ick-Hwan;Kim, Young-Oh
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.3 s.164
    • /
    • pp.187-198
    • /
    • 2006
  • Korea Water Resources Corporation(KOWACO) has developed the Integrated Real-time Water Management System(IRWMS) that calculates monthly optimal ending target storages by using Sampling Stochastic Dynamic Programming(SSDP) with Ensemble Streamflow Prediction(ESP) running on the $1^{st}$ day of each month. This system, however, has a shortcoming: it cannot reflect the hydrolmeteorologic variations in the middle of the month. To overcome this drawback, in this study updated ESP forecasts three times each month by using the observed precipitation series from the $1^{st}$ day of the month to the forecast day and the historical precipitation ensemble for the remaining days. The improved accuracy and its effect on the reservoir operations were quantified as a result. SSDP/ESP21 that reflects within-a-month hydrolmeteorologic states saves $1\;X\;10^6\;m^3$ in water shortage on average than SSDP/ESP01. In addition, the simulation result demonstrated that the effect of ESP accuracy on the reduction of water shortage became more important when the total runoff was low during the drawdown period.

Evaluation of Raw and Calcined Eggshell for Removal of Cd2+ from Aqueous Solution

  • Kim, Youngjung;Yoo, Yerim;Kim, Min Gyeong;Choi, Jong-Ha;Ryoo, Keon Sang
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.5
    • /
    • pp.249-258
    • /
    • 2020
  • The potential use of egg shell and calcined egg shell as adsorbent was evaluated and compared to remove Cd2+ from aqueous solution. The samples were characterized using Thermogravimetry and Differential Thermal Analysis (TG/DTA), Scanning Electron Microscope (SEM), X-ray Diffractometer (XRD), Energy Dispersive X-ray Spectrometer (EDX) and BET Surface Analyzer. The batch-type adsorption experiment was conducted by varying diverse variables such as contact time, pH, initial Cd2+ concentrations and adsorbent dosage. The results showed that, under the initial Cd2+ concentrations ranged from 25 to 200 mg g-1, the removal efficiencies of Cd2+ by egg shell powder (ESP) were decreased steadily from 96.72% to 22.89% with increase in the initial Cd2+ concentration at 2.5 g of dosage and 8 h of contact time. However, on the contrary to this, calcined egg shell powder (CESP) showed removal efficiencies above 99% regardless of initial Cd2+ concentration. The difference in the adsorption behavior of Cd2+ may be explained due to the different pH values of ESP and CESP in solution. Cd2+ seems to be efficiently removed from aqueous solution by using the CESP with a basicity nature of around pH 12. It was also observed that an optimum dosage of ESP and CESP for nearly complete removal of Cd2+ from aqueous solution is approximately 5.0 g and 1.0 g, respectively. Consequently, Cd2+ is more favorably adsorbed on CESP than ESP in the studied conditions. Adsorption data were applied by the pseudo-first-order and pseudo-second-order kinetics models and Freundlich and Langmuir isotherm models, respectively. With regard to adsorption kinetics tests, the pseudo-second-order kinetics was more suitable for ESP and CESP. The adsorption pattern of Cd2+ by ESP was better fitted to Langmuir isotherm model. However, by contrast with ESP, CESP was described by Freundlich isotherm model well.

A Study on the Smoke Removal Characteristics of the ESP Adopting Resonant dc-dc Converter

  • Kim, Su-Weon;Park, Jong-Woong;Joung, Jong-Han;Chung, Hyun-Ju;Choi, Jin-Young;Kim, Hee-Je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.5
    • /
    • pp.193-200
    • /
    • 2004
  • In this study, we propose a small high voltage power supply, which uses a half-bridge ZCS resonant and Cockroft-Walton circuit as its ESP (Electrostatic Precipitator). This power supply transfers energy from the ZCS resonant inverter to the step-up transformer. The transformer secondary is then applied to the Cockroft-Walton circuit for generating high voltage as a discharging source of electrodes. It is highly efficient because its amount of switching losses are reduced by virtue of the current resonant half-bridge inverter, and also due to the small size, low parasitic capacitance in the transformer stage owing to the low number of winding turns of the step up transformer secondary combined with the Cockroft-Walton circuit. Using this power supply, experiments have been carried out as a function of the switching frequency and duty ratio in order to investigate the smoke removal characteristics. From these results, the best operational condition is obtained at the switching frequency of 9 kHz and the duty ratio of 50% in this ESP.

Gas Pressure Sintering, Mechanical Properties and Microstructure of Three Binds of Si3N4 Ceramics

  • Ha, Sung-Soo;Kim, Chang-Sam;Cheong, Deoek-Soo
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.10 s.269
    • /
    • pp.723-727
    • /
    • 2004
  • Three kinds of $Si_3N_4$ powders (M-11, SN-ESP, and SN-E10) were gas-pressure sintered at $1700-1900^{\circ}C$ for 2 h under 18 atm $N_2$. Their densification behavior was investigated and compared as well as the mechanical properties and microstructure of the resulting ceramics. SN-ESP and SN-E10 started to reach nearly full densification at $1750^{\circ}C$ and showed almost no decomposition up to $1900^{\circ}C$. In contrast, M-11 was not fully densified until $1800^{\circ}C$ and showed about $3\%$ weigh loss at $1900^{\circ}C$ indicating poor thermal stability. SN-ESP and SN-E10 showed much higher strength both at room temperature and $1200^{\circ}C$ than M-11 when fully densified. Compared with SN-ESP, SN-E10 was not only a little better in strength (both at room temperature and $1200^{\circ}C$) and fracture toughness but also much higher in the Weibull modulus due to more interlocked microstructure by well elongated grains.

Removal of Serratia marcescens Aerosols Using an Electrostatic Precipitator Air-Cleaner

  • Ko, Gwang-Pyo;Burge, Harriet
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.10
    • /
    • pp.1622-1628
    • /
    • 2007
  • We characterized the efficacy of an electrostatic precipitator (ESP) air-cleaner in reducing the concentration of Serratia marcescens in an enclosed space. We used an experimental room ($4.5{\times}3{\times}2.9\;m$) in which electrostatic air-cleaners were located. Two air-cleaners enhanced the equivalent ventilation rates in the chamber by about 3.3 air changes per hour (ACH) over the 2 ACH provided by the mechanical ventilation system. Natural die-off of the organisms provided an additional equivalent of 3 ACH, so that the total ventilation rate with the ESP air-ccleaners was 8.3 ACH. We also examined whether the ESP air-cleaners altered the deposition of Serratia marcescens aerosols on the experimental room surfaces. We did not find any significant differences in the number of colony forming units recovered from surfaces with and without the air-cleaners. We installed UV lights inside the ESPs and determined if UV light, in addition to electrical fields, increased the efficacy of the ESPs. The presence of UV light inside the ESP reduced S. marcescens aerosols by approximately 2 ACH. Finally, a box model indicates that the efficiency of the air-cleaner increases for both biological and nonbiological particles at ventilation rates of 0.2-1, which are typical for residential settings.

Deflective Behavior of Charged Particles in a Two-Stage Electrostatic Precipitator

  • Lim, Hun-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.83-91
    • /
    • 2011
  • Even if smoke, fumes, mist or dust particles are removed by electrostatic precipitators (ESPs), the occurrence of ozone, which is harmful to human body, has to be severely restricted in the indoor environments of hospitals, offices, and workshops. Therefore, the two-stage ESP generating positive corona at the ionizer is typically used because it creates less ozone than the two-stage ESP generating negative corona at the ionizer. In order to predict the collection performance and the optimal design of the two-stage ESP applied to positive high-voltage, particle concentration is experimentally investigated in this paper. In addition, particle motion within the collector section is also numerically analyzed. The positive corona discharge current of the ionizer is found to be affected by the applied voltage in the collector section but less so by the particle concentration. Particle concentration shows a minimum near the high voltage electrode of the collector section. The minimum value of the collection efficiency is almost proportional to gas velocity. When the collector length decreases, the minimum value of the collection efficiency increases. Charged particles entering the collector region are linearly deflected towards the grounded plate by an electric field. From the above experimental and numerical results, two empirical equations on the concentration ratio and the collection efficiency are derived, and are in good agreement with the experimental data.

A study of Cryptographic Algorithms of IKE version 2 Protocol (IKE 버전 2 프로토콜의 암호 알고리즘에 관한 연구)

  • 김윤희;이유태;이계상
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.199-202
    • /
    • 2003
  • IPsec is a standardization way for protection of IP packets in network layer and it is composed of three protocols that is AH(Authentication Header), ESP(Encapsulation Security Protocol) and IKE(Internet Key Exchange). Before doing encryption and decryption using AH or ESP protocols, both of communicating entities have to share same key safely. IKE protocol works automatically. But it has less interoperability because IKE protocol is not simple. A work which standardize IKEv2 has been done up to now. In this article, we will examine the Cryptographic Algorithms of IKEv2, and describe the AES usage with IPsec, based on the IETF Draft document.

  • PDF