Browse > Article
http://dx.doi.org/10.11629/jpaar.2018.14.4.089

Comparison of particle collection characteristics in a wire-cylindrical wet electrostatic precipitator with and without a water film  

Woo, Chang Gyu (Department of Environmental Machinery, Korea Institute of Machinery & Materials)
Cho, Won Ki (Department of Environmental Machinery, Korea Institute of Machinery & Materials)
Kim, Hak-Joon (Department of Environmental Machinery, Korea Institute of Machinery & Materials)
Kim, Yong-Jin (Department of Environmental Machinery, Korea Institute of Machinery & Materials)
Han, Bangwoo (Department of Environmental Machinery, Korea Institute of Machinery & Materials)
Publication Information
Particle and aerosol research / v.14, no.4, 2018 , pp. 89-95 More about this Journal
Abstract
People's environmental concerns for fine particles in Korea lead to the strong necessity of improving the performance of environmental control systems. Wet electrostatic precipitators (ESPs) are considered as one of the alternatives to overcome the limit of previous dry ESPs, the re-entrainment of collected particles during rapping and back corona problem for high electrical resistivity dusts etc. In this study, a wire-cylindrical ESP with a thin water film has been developed. Particle collection characteristics were compared in the ESP with operations of water film on and off. Particle collection efficiencies at various applied voltages as well as voltage-current curves were almost the same in the ESP with and without a water film. Particle collection performance for PM1.0, PM2.5 and PM10 in the wet ESP with a water film was constantly maintained with operation time even in the high dust loading environment. This results indicate that a uniform water film in our wet ESP was successfully formed with a very thin layer without any dry spot and therefore could continuously clean the collected particles on the inner wall of the ESP without any performance degradation.
Keywords
fine particles; collection; coating; water-film; cleaning;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Hinds, W. C. (1999). Aerosol Technology: Properties, Behavior, and Measurement of Airborne Particles, 2nd Ed., New York, John Wiley & Sons, Inc.
2 Huang, S.-H, and Chen, C.-C. (2002). Ultrafine aerosol penetration through electrostatic precipitators, Environmental Science and Technology, 36(21), 4625-4632.   DOI
3 Huang, Y., Yin, Z., Chen, Y., and Guo X. (2018). Experimental study on gaseous elemental mercury removal by wet electrostatic precipitators, Fuel, 234, 1337-1345.   DOI
4 Kim, H.-J., Han, B., Kim, Y.-J., Hwang, K.-D., Oh, W.-S., Yoo, S.-Y., and Oda, T. (2011). Fine particle removal performance of a two-stage wet electrostatic precipitator using a nonmetallic pre-charger, Journal of the Air & Waste Management Association, 61(12), 1334-1343.   DOI
5 Lin, G.-Y., Tsai, C.-J., Chen, S.-C., Chen, T.-M., and Li, S.-N. (2010). An efficient single-stage wet electrostatic precipitator for fine and nanosized particle control, Aerosol Science and Technology, 44, 38-45.   DOI
6 Sui, Z., Zhang, Y., Peng, Y., Norris, P., Cao, Y., and Pan, W.-P. (2016). Fine particulate matter emission and size distribution characteristics in an ultra-low emission power plant, Fuel, 185, 863-871.   DOI
7 Wang, X., and You, C. (2013). Effects of thermophoresis, vapor, and water film on particle removal of electrostatic precipitator, Journal of Aerasol Science, 63, 1-9.   DOI
8 Ferge, T., Maguhn, J., Felber, H., and Zimmermann, R. (2004). Particle collection efficiency and particle re-entrainment of an electrostatic precipitator in a sewage sludge incineration plant, Environmental Science and Technology 38(5), 1545-1553.   DOI
9 Wiggers, H. (2007). Measurement of dust resistivity. Back corona in electrostatic precipitators, VGB PowerTech, 87(3), 93-96.
10 Hamra, G. B., Guha, N., Cohen, A., Laden, F., Raaschou-Nielsen, O., Samet, J. M., Vineis, P., Forastiere, F., Saldiva, P., Yorifuji, T., and Loomis, D. (2014). Outdoor particulate matter exposure and lung cancer: A systematic review and meta-analysis, Environmental Health Perspectives, 122(9), 906-911.   DOI
11 Yang, Z., Zheng, C., Zhang, X., Li, C., Wang, Y., Weng, W., and Gao, X. (2017). Sulfuric acid aerosol formation and collection by corona discharge in a wet electrostatic precipitator, Energy Fuels, 31(8), 8400-8406.   DOI
12 Zhao, H., He, Y., and Yao Y. (2018). Study on brush of moving electrode type electrostatic precipitator (MEEP), IOP Conference Series: Earth and Environmental Science, 121, 052024.