Measurements of Fast Transient Voltages due to Human Electrostatic Discharges (인체에 대전된 정전기 방전에 의해 발생한 급속과도전압의 측정)

  • 이복희;이동문;강성만;엄주홍;이태룡;이승칠
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.4
    • /
    • pp.108-116
    • /
    • 2002
  • This paper presents the measurements and evaluation of voltage waveforms due to human electrostatic discharge(ESD). The principle of operation and design rule of a new device for measuring the ESD fast transient voltages with very fast rise time were described. Peak values and rise time of ESD voltages derived from a charged human body under a variety of experimental conditions were examined. The frequency bandwidth of the proposed voltage measuring system ranges from DC to 400[㎒]. The ESD voltage waveform is nearly equal to the ESD current waveform and the peak amplitude of ESD current waveform is roughly proportional to the ESD voltage in each experimental conditions. A rapid approach results in a discharge voltage with a faster initial rise time than for a slow approach. The voltages caused by direct finger ESDs have an initial slope with a relatively long, 10∼30[ns] rise time, but the amplitude is small. On the other hand, the voltages caused by direct hand/metal ESDs have a steep initial s1ope with 1 ∼3[ns] rise time, but an initial spike is very big. As a consequence, it was found that the ESD voltage and current waveforms strongly depend on the approach speed and material of intruder. These measurement results would be useful to design the ESD protective devices.

Characteristics of the Voltage Waveforms Caused by Human Electrostatic Discharges (인체에 의한 정전기 방전전압 파형의 특성)

  • 이복희;강성만;엄주홍;이태룡
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.113-120
    • /
    • 2002
  • This paper describes characteristics of transient voltage waveforms caused by human electrostatic discharges(ESDs). For purpose of achieving the statistics on the meaningful amplitude and initial slope for transient ESD voltage waveforms, transient voltages due to human ESDs in various conditions were observed. A voltage measuring system with a wide bandwidth from DC to 400[MHz] was employed. ESD voltage waveforms are approximately the same as ESD current waveforms. Also the simulated results, which are calculated by the reposed equivalent circuit, are closely similar to the measured voltage waveforms. ESD voltage waveforms are strongly dependent on the approach speed and material of intruder, a fast approach causes ESD voltage waveform with a steep rise time than for a slow approach. The voltage waveforms from dialect finger ESDs have a relatively long rise time of 10∼30[ns], but their peaks are low. On the other side ESD voltage waveforms causer by screwdriver with insulating handle have a steep slope with a very short, less than 1[ns] rise time, but their initial spikes are extremely high The obtained results in this work would be applied to solve ESD problems for low voltage and small current electronic devices.