• Title/Summary/Keyword: ESD

Search Result 455, Processing Time 0.023 seconds

Input Balun Design Method for CMOS Differential LNA (차동 저 잡음 증폭기의 입력 발룬 설계 최적화 기법)

  • Yoon, Jae-Hyuk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.5
    • /
    • pp.366-372
    • /
    • 2017
  • In this paper, the analysis of baluns that are inevitably required to design a differential low noise amplifier, The balun converts a single signal input from the antenna into a differential signal, which serves as an input to the differential amplifier. In addition, it protects the circuit from ESD(Electrostatic Discharge) coming through the antenna and helps with input matching. However, in the case of a passive balun used in general, since the AC signal is transmitted through electromagnetic coupling formed between two metal lines, it not only has loss without gain but also has the greatest influence on the total noise figure of the receiving end. Therefore, the design of a balun in a low-noise amplifier is very important, and it is important to design a balun in consideration of line width, line spacing, winding, radius, and layout symmetry that are necessary. In this paper, the factors to be considered for improving the quality factor of balun are summarized, and the tendency of variation of resistance, inductance, and capacitance of the balun according to design element change is analyzed. Based on the analysis results, it is proved that the design of input balun allows the design of low noise, high gain differential amplifier with gain of 24 dB and noise figure of 2.51 dB.

The Review of Exposure Index in Digital Radiography and Image Quality (디지털 영상에서 화질관리에 관한 노출지수(EI)의 유용성 연구)

  • Yang, Sook;Han, Jae Bok;Choi, Nam Gil;Lee, Seong Gil
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.1
    • /
    • pp.29-36
    • /
    • 2013
  • The aim of this study was to determine the correlation between exposure index (EI) and dose factors related to radiation dose optimization in digital radiography (DR) system. Two phantoms with built-in regional test object for quantitative assessment of images were used to produce image signals that acquired in chest radiography background. EI and entrane surface dose (ESD) increased proportionally with rise of radiation dose (kVp, mAs) in both DR and CR systems. Especially, DR detector was effective to form good contrast and hence, reached easily to improvement of image quality with minimal dose changes. It made operators possible to expect the accuracy of EI values deeply related to absorbed dose of the detector. The evaluation of images was obtained specially employed calculation of noise to signal ratio (NSR) and contrast to noise ratio (CNR). These measurements were performed for how exposure factors affect image quality. NSR was inversely proportional to kVp and mAs and low NSR represented high signal detection efficiency. Consequently, EI values was the measure of the amount of exposure received by the image receptor and it was proportional to exposure factors. Therefore the EI in a recommended range from manufacturer can offer optimal image quality. Also, continuous monitoring of EI values in the digital radiography can reduce the unnecessary patient dose and help the quality control of the system.

A Study on Patients Dose and Image Quality according to Source to Image receptor Distance in Abdomen Radiography: comparison of ESD measured and DRLs in other countries (복부일반촬영시 선원과 검출기간의 거리변화에 따른 영상 화질 및 피폭선량에 관한 연구)

  • Jang, Ji-Sung;Choi, Weon-Keun;Jung, Jae-Yon;Lee, Kwan-Sub;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.39-46
    • /
    • 2012
  • Purpose : The purpose of this study was to reduce Entrance Surface Dose and maintain image quality by changing Source to Image receptor Distance. And we'd like to compare ESD on this study to DRLs in other contries. Materials and Methods : We used indirect DR system(Definium 8000, General Electric, USA)and phantom(ART-200X, Flukebiomedical, USA),glass dosimeters(GD-352M, Asahi Techno Glass, Japan)for this study. The imagies were obtained throuh 80kVp fixed, and different tube currents using AEC mode in $16{\times}16$(inch) field size and changing Source to Image receptor Distance from 100 cm to 130 cm per 10 cm unit. The phantom with attaching 5 glass dosimeters on abdomonal skin was set at supine and erect position as a anterioposterial projection on detector For measuring Entrance Surface Dose. Image analysis was conducted by histograms of Image J(1.46r) which was given from National Institutes of Health(NIH). Results : Due to inverse square law of distance, the tube currents were increasing 42.6 % in supine position and 32.6 % in erect position according to the change of Source to Image receptor Distance. While Entrance Surface Doses were rapidly decreasing 14.2 % in supine position and 29.4 % in erect position according to the change of Source to Image receptor Distance. As the results of histogram using Image J, pixel mean values from 100 cm to 110 cm, 120 cm and 130 cm were decreasing each 1.4%, 2.5%, 2.7%, 4.5%, 2.2 %, 5.8 % in supine, erect position. While standard deviations from 100 cm to 110 cm, 120 cm and 130 cm were increasing each 1.4 %, 2.5 %, 2.5 %, 4.0 %, 2.0 %, 4.9 % Consequently, there are no significant differences in abdomen images taken. Conclusion: As the results described above, we strongly recommend using long Sourceto Image receptor Distance than 100cm that we have been using. So, we should deliver less Entrance Surface Dose to the patients while maintaining image quality in abdomen radiography.

  • PDF

The investigation of the exposure dose reduction of the Staff according to the Lead Curtain installation in EVAR(Endovascular Aneurysm Repair) surgical operation using C-arm (C-arm을 이용한 EVAR(Endovascular Aneurysm Repair) 시술시 Lead Curtain 설치에 따른 Staff의 피폭선량 감소에 대한 연구)

  • Yoo, In Woung;Chung, Jea Yeon;Lee, Kwan Seob
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.33-38
    • /
    • 2012
  • In EVAR procedure using long time C-arm, we studied exposure dose reduction and effeciency through measuring surgical staff's ESD by installing lead curtain operating table next to. The height 3 the spot (50cm, 100cm, 150cm) dose was measured on 2 locations for 600sec in the X-ray radiation considering the surgical staff's movement. To install the curtains, we compared before and after the dose. As a result, it can confirm that dose of the installation former of 50cm height and after is reduced about 75% and 91% in 2 locations. In 100cm height, the reduction of the dose was a bit confirmed. There as to dose value, measured on 150cm height the installation former and after was nearly no change. This research examined the exposure dose about the radiation of the surgical staff during EVAR procedure in which the operation time is the long time. It was implemented in the object that it reduces the radiation exposure. It could confirm the certain effect of the experimental result exposure dose reduction In EVAR procedure using long time C-arm, we studied exposure dose reduction and effeciency through measuring surgical staff's ESD by installing lead curtain operating table next to. The height 3 the spot (50cm, 100cm, 150cm) dose was measured on 2 locations for 600sec in the X-ray radiation considering the surgical staff's movement. To install the curtains, we compared before and after the dose. As a result, it can confirm that dose of the installation former of 50cm height and after is reduced about 75% and 91% in 2 locations. In 100cm height, the reduction of the dose was a bit confirmed. There as to dose value, measured on 150cm height the installation former and after was nearly no change. This research examined the exposure dose about the radiation of the surgical staff during EVAR procedure in which the operation time is the long time. It was implemented in the object that it reduces the radiation exposure. It could confirm the certain effect of the experimental result exposure dose reduction.

  • PDF

Analysis of Research Trends in Education for Sustainable Development in the Practical Arts (Technology & Home Economics) Education: Focusing on 'Family Life' Area (실과(기술·가정)교육의 지속가능발전교육 연구 동향 분석: '가정생활' 영역을 중심으로)

  • Lee, Hana
    • Journal of Korean Home Economics Education Association
    • /
    • v.31 no.4
    • /
    • pp.81-95
    • /
    • 2019
  • This study examined the research trends of sustainable development education in the family life area, focusing on papers published in journals specialized in the Practical Arts (Technology & Home Economics) subject from 1989 to 2018. The papers from three journals were selected based on the titles, abstracts, and keywords for their contents related to sustainable development education. The results were analyzed by frequency analysis and cross-tabulation. Sustainable development education has surged since the mid-2000s when national interest on this topic sharply increased. Rather than focusing on particular content areas in home economics, most research was conducted through an integrated approach. More than half of the studies were conducted in experimental studies, with the largest number of studies involving elementary school students. Of the three components of ESD, research on society was most frequently conducted, followed by the environmental area. The contents of the home economics curriculum and the details of sustainable development were related. More related research should be conducted so that various sustainable development education can improve students' practical problem-solving ability through Practical Arts (Technology & Home Economics) curriculum.

Endoscopic Findings and Treatment of Gastric Neoplasms in Familial Adenomatous Polyposis

  • Sato, Chihiro;Takahashi, Kazuya;Sato, Hiroki;Naruse, Takumi;Nakajima, Nao;Takatsuna, Masafumi;Mizuno, Ken-ichi;Hashimoto, Satoru;Takeuchi, Manabu;Yokoyama, Junji;Kobayashi, Masaaki;Terai, Shuji
    • Journal of Gastric Cancer
    • /
    • v.22 no.4
    • /
    • pp.381-394
    • /
    • 2022
  • Purpose: Gastric neoplasia is a common manifestation of familial adenomatous polyposis (FAP). This study aimed to elucidate the clinical characteristics, endoscopic features including fundic gland polyposis (FGPsis), and treatment outcomes of gastric neoplasms (GNs) in patients with FAP. Materials and Methods: A total of 35 patients diagnosed with FAP, including nine patients from four pedigrees who underwent esophagogastroduodenoscopy (EGD), were investigated regarding patient characteristics, GN morphology, and treatment outcomes. Results: Twenty-one patients (60.0%) had 38 GNs; 33 (86.8%) and 5 (13.2%) were histologically diagnosed with adenocarcinoma and adenoma, respectively. There were no specific patient characteristics related to GNs.Nodule-type GNs were more prevalent in patients with FGP than without (52.2% vs. 0.0%, P=0.002) in the upper body of the stomach. Conversely, depressed-type GNs were fewer in patients with FGPsis than in those without (13.0% vs. 73.3%, P<0.001). Slightly elevated-type GNs were observed in both groups (34.8% vs. 20.0%, P=0.538). Even within pedigrees, the background gastric mucosa and types of GNs varied. In total, 24 GNs were treated with endoscopic submucosal dissection (ESD) and eight with endoscopic mucosal resection (EMR). EMR was selected for GNs with FGPsis because of the technical difficulty of ESD, resulting in a lower en bloc resection rate (62.5% vs. 100%, P=0.014). Conclusions: Our study indicates the necessity of routine EGD surveillance in patients diagnosed with FAP. Notably, the morphology and location of GNs differed between patients with and without FGPsis. Endoscopic treatment and outcomes require more attention in cases of FGPsis.

Investigation of Applying Technical Measures for Improving Energy Efficiency Design Index (EEDI) for KCS and KVLCC2

  • Jun-Yup Park;Jong-Yeon Jung;Yu-Taek Seo
    • Journal of Ocean Engineering and Technology
    • /
    • v.37 no.2
    • /
    • pp.58-67
    • /
    • 2023
  • While extensive research is being conducted to reduce greenhouse gases in industrial fields, the International Maritime Organization (IMO) has implemented regulations to actively reduce CO2 emissions from ships, such as energy efficiency design index (EEDI), energy efficiency existing ship index (EEXI), energy efficiency operational indicator (EEOI), and carbon intensity indicator (CII). These regulations play an important role for the design and operation of ships. However, the calculation of the index and indicator might be complex depending on the types and size of the ship. Here, to calculate the EEDI of two target vessels, first, the ships were set as Deadweight (DWT) 50K container and 300K very large crude-oil carrier (VLCC) considering the type and size of those ships along with the engine types and power. Equations and parameters from the marine pollution treaty (MARPOL) Annex VI, IMO marine environment protection committee (MEPC) resolution were used to estimate the EEDI and their changes. Technical measures were subsequently applied to satisfy the IMO regulations, such as reducing speed, energy saving devices (ESD), and onboard CO2 capture system. Process simulation model using Aspen Plus v10 was developed for the onboard CO2 capture system. The obtained results suggested that the fuel change from Marine diesel oil (MDO) to liquefied natural gas (LNG) was the most effective way to reduce EEDI, considering the limited supply of the alternative clean fuels. Decreasing ship speed was the next effective option to meet the regulation until Phase 4. In case of container, the attained EEDI while converting fuel from Diesel oil (DO) to LNG was reduced by 27.35%. With speed reduction, the EEDI was improved by 21.76% of the EEDI based on DO. Pertaining to VLCC, 27.31% and 22.10% improvements were observed, which were comparable to those for the container. However, for both vessels, additional measure is required to meet Phase 5, demanding the reduction of 70%. Therefore, onboard CO2 capture system was designed for both KCS (Korea Research Institute of Ships & Ocean Engineering (KRISO) container ship) and KVLCC2 (KRISO VLCC) to meet the Phase 5 standard in the process simulation. The absorber column was designed with a diameter of 1.2-3.5 m and height of 11.3 m. The stripper column was 0.6-1.5 m in diameter and 8.8-9.6 m in height. The obtained results suggested that a combination of ESD, speed reduction, and fuel change was effective for reducing the EEDI; and onboard CO2 capture system may be required for Phase 5.

Automation of Online to Offline Stores: Extremely Small Depth-Yolov8 and Feature-Based Product Recognition (Online to Offline 상점의 자동화 : 초소형 깊이의 Yolov8과 특징점 기반의 상품 인식)

  • Jongwook Si;Daemin Kim;Sungyoung Kim
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.17 no.3
    • /
    • pp.121-129
    • /
    • 2024
  • The rapid advancement of digital technology and the COVID-19 pandemic have significantly accelerated the growth of online commerce, highlighting the need for support mechanisms that enable small business owners to effectively respond to these market changes. In response, this paper presents a foundational technology leveraging the Online to Offline (O2O) strategy to automatically capture products displayed on retail shelves and utilize these images to create virtual stores. The essence of this research lies in precisely identifying and recognizing the location and names of displayed products, for which a single-class-targeted, lightweight model based on YOLOv8, named ESD-YOLOv8, is proposed. The detected products are identified by their names through feature-point-based technology, equipped with the capability to swiftly update the system by simply adding photos of new products. Through experiments, product name recognition demonstrated an accuracy of 74.0%, and position detection achieved a performance with an F2-Score of 92.8% using only 0.3M parameters. These results confirm that the proposed method possesses high performance and optimized efficiency.

Morphogenesis of Component Unit in Spatial Grid Structure (공간그리드구조 구성유닛의 형태구성)

  • Park, Chan-Soo;Choi, Sun-Young
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.3 s.25
    • /
    • pp.125-132
    • /
    • 2007
  • The purpose of this study is to investigate the functions and formations of the component units as aesthetic components in the spatial grid. The main subject covered here is the presentation of the morphological method of shaping spatial grid by application of 3-dimensional units satisfying the suitable form of polyhedra, tensegrity and hybrid structure. In accordance with the subject, the definition of the spatial grid and 3-dimensional nit, the relationship between them, and then the functions of those units are reviewed. And the formations of polyhedral units, tensegrity units and hybrid units are generated by means of the modules of the simplest type or pattern. And also the overall appearance of the spatial grid shaped by several basic methods in which one unit can be joined to another and arranged are depicted.

  • PDF

A Study on Analysis of Electrostatics Destruction of Electronic Equipment (전자부품의 정전파괴(ESD) 분석에 관한 연구)

  • Lee, Du-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.6
    • /
    • pp.235-241
    • /
    • 2010
  • The static electricity generated by friction of two objects is called frictional electricity. The main cause of troubles in electronic components for military and civil use as well as in military radar appliances is found mostly in parts like LSI memories, particularly when they lose information of function momentarily while in operation, which usually leads to a fatal cause of troubles in the equipment. Troubles occur if electric noise is caused by the spark effected from discharge of static electricity from the equipment that is used nearby.