• Title/Summary/Keyword: ERS

Search Result 369, Processing Time 0.033 seconds

A Study on Rapid Residual Analysis of Benzo(a)pyrene in Agricultural Products and Soils (농산물 및 경작지 토양 시료 중 Benzo(a)pyrene 신속잔류분석법 개선 연구)

  • Kim, Hee-Gon;Ham, Hun-Ju;Hong, Kyong-Suk;Shin, Hee-Chang;Hur, Jang Hyun
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.1
    • /
    • pp.44-49
    • /
    • 2020
  • BACKGROUND: Benzo(a)pyrene is a highly toxic substance which has been listed as a Group I carcinogen by the International Agency for Research on Cancer. There have been numerous studies by researchers worldwide on benzo(a)pyrene. Soxhlet, ultrasound-assisted, and liquid-liquid extractions have been widely used for the analysis of benzo(a)pyrene. However these extraction methods have significant drawbacks, such as long extraction time and large amount of solvent usage. To overcome these disadvantages, we aimed to establish a rapid residual analysis of benzo(a)pyrene content in agricultural products and soil samples. METHODS AND RESULTS: A Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) method was used as the pretreatment procedure. For rapid residual analysis of benzo(a)pyrene, a modified QuEChERS method were used, and the best codition was demonstrated after various performing instrument analysis. The extraction efficiency of this method was also compared with Soxhlet extraction, the current benzo(a)pyrene extracting method. Although both methods showed high recovery rates, the rapid residual analysis method markedly reduced both the measurement time and solvent usage by approximately 97% and 96%, respectively. CONCLUSION: Based on these results, we suggest the rapid residual analysis method established through this study, faster and more efficient analysis of residual benzo(a)pyrene in major agricultural products such as rice, green and red chili peppers and also soil samples.

Information Delivery Requirements of Steel Structure according the Structural Design Stages using IDM (IDM을 이용한 강구조의 구조설계 단계별 정보전달 요구 분석)

  • Lee, Jae-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1467-1473
    • /
    • 2013
  • In construction project, it is important to exchange and share the digital information generated by their own professional softwares. So this paper analyzed the information delivery requirements of steel structure according the structural design stages using IDM methodology. For schematic design stage and detailed design stage, the structural design information to share in each design stages is abstracted by defining the PM, ER, and FP. The new ERs and FPs are proposed by defining the new property sets(Psets), suchlike bolt gauge line, weld, scallop, and cope, to complement the structural design information of $IFC2{\times}3$. Finally, the reasonability of the proposed new ERs, FPs are verified by applying them to represent the standard steel connection sample in detailed design stage. As a result, the structural design information of standard steel connection could be stored and managed sufficiently by using the proposed new ERs and FPs.

Validation and selection of GCPs obtained from ERS SAR and the SRTM DEM: Application to SPOT DEM Construction

  • Jung, Hyung-Sup;Hong, Sang-Hoon;Won, Joong-Sun
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.5
    • /
    • pp.483-496
    • /
    • 2008
  • Qualified ground control points (GCPs) are required to construct a digital elevation model (DEM) from a pushbroom stereo pair. An inverse geolocation algorithm for extracting GCPs from ERS SAR data and the SRTM DEM was recently developed. However, not all GCPs established by this method are accurate enough for direct application to the geometric correction of pushbroom images such as SPOT, IRS, etc, and thus a method for selecting and removing inaccurate points from the sets of GCPs is needed. In this study, we propose a method for evaluating GCP accuracy and winnowing sets of GCPs through orientation modeling of pushbroom image and validate performance of this method using SPOT stereo pair of Daejon City. It has been found that the statistical distribution of GCP positional errors is approximately Gaussian without bias, and that the residual errors estimated by orientation modeling have a linear relationship with the positional errors. Inaccurate GCPs have large positional errors and can be iteratively eliminated by thresholding the residual errors. Forty-one GCPs were initially extracted for the test, with mean the positional error values of 25.6m, 2.5m and -6.1m in the X-, Y- and Z-directions, respectively, and standard deviations of 62.4m, 37.6m and 15.0m. Twenty-one GCPs were eliminated by the proposed method, resulting in the standard deviations of the positional errors of the 20 final GCPs being reduced to 13.9m, 8.5m and 7.5m in the X-, Y- and Z-directions, respectively. Orientation modeling of the SPOT stereo pair was performed using the 20 GCPs, and the model was checked against 15 map-based points. The root mean square errors (RMSEs) of the model were 10.4m, 7.1m and 12.1m in X-, Y- and Z-directions, respectively. A SPOT DEM with a 20m ground resolution was successfully constructed using a automatic matching procedure.

Catch Variations of Argentine Shortfin Squid Illex argentinus in the Southwest Atlantic (남서대서양 아르헨티나 짧은지느러미오징어(Illex argentinus)의 어획변동)

  • Ku, Jeong Eun;Choi, Seok-Gwan;An, Doo-Hae;Kim, Eunjung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.53 no.6
    • /
    • pp.934-941
    • /
    • 2020
  • The spatial and temporal catch variations of Argentine shortfin squid Illex argentinus in the Southwest Atlantic Ocean (SWA) were analyzed using Korean squid-jigging fishery data collected through electronic reporting system (ERS) from 2016 to 2020. The ERS linked with GPS has been implemented for collecting fishing data from all Korean fishing vessels operating in international waters since November 2015. The fishing period of the Korean squid-jigging fishery in the SWA runs from early summer to autumn (December to June) in the Southern Hemisphere. The fishing ground was extended from 42°S to 48°S along the Patagonian continental shelf and slope, and the main fishing ground was formed around the Falkland Islands. The yearly catch per unit effort (CPUE) of I. argentinus fluctuated between 1.69 and 7.53 tons/day. In this study, during the fishing season, a south and westward shift on the fishing ground was observed indicating the feeding migration of the south Patagonian stock. The shift in monthly fishing centroids differed according to fishing season. The gradual southward shifts of fishing centroids were observed in the catch years (2017 and 2018), whereas unapparent shifts in fishing centroids were observed in the low catch years (2016 and 2019).

Noise and Room Acoustic Conditions in a Tertiary Referral Hospital, Seoul National University Hospital

  • Cho, Wan-Ho;Jeong, Cheol-Ho;Chang, Ji-Ho;Lee, Seong-Hyun;Park, Moo Kyun;Suh, Myung-Whan;Han, Jae Joon
    • Journal of Audiology & Otology
    • /
    • v.23 no.2
    • /
    • pp.76-82
    • /
    • 2019
  • Background and Objectives: Noise levels and room acoustic parameters at a tertiary referral hospital, Seoul National University Hospital (SNUH) in Korea, are investigated. Materials and Methods: Through a questionnaire, acoustically problematic rooms are identified. Noise levels in emergency rooms (ERs) and intensive care units (ICUs) are measured over about three days. Acoustically critical and problematic rooms in the otolaryngology department are measured including examination rooms, operating rooms, nurse stations, receptions, and patient rooms. Results: The A-weighted equivalent noise level, LAeq, ranges from 54 to 56 dBA, which is at least 10 dB lower than the noise levels of 65 to 73 dBA measured in American ERs. In an ICU, the noise level for the first night was 66 dBA, which came down to 56 dBA for the next day. The noise levels during three different ear surgeries vary from 57 to 62 dBA, depending on the use of surgical drills and suctions. The noise levels in a patient room is found to be 47 dBA, while the nurse stations and the receptions have high noise levels up to 64 dBA. The reverberation times in an operation room, examination room, and single patient room are found to be below 0.6 s. Conclusions: At SNUH, the nurse stations and receptions were found to be quite noisy. The ERs were quieter than in the previous studies. The measured reverberation times seemed low enough but some other nurse stations and examination rooms were not satisfactory according to the questionnaire.

Noise and Room Acoustic Conditions in a Tertiary Referral Hospital, Seoul National University Hospital

  • Cho, Wan-Ho;Jeong, Cheol-Ho;Chang, Ji-Ho;Lee, Seong-Hyun;Park, Moo Kyun;Suh, Myung-Whan;Han, Jae Joon
    • Korean Journal of Audiology
    • /
    • v.23 no.2
    • /
    • pp.76-82
    • /
    • 2019
  • Background and Objectives: Noise levels and room acoustic parameters at a tertiary referral hospital, Seoul National University Hospital (SNUH) in Korea, are investigated. Materials and Methods: Through a questionnaire, acoustically problematic rooms are identified. Noise levels in emergency rooms (ERs) and intensive care units (ICUs) are measured over about three days. Acoustically critical and problematic rooms in the otolaryngology department are measured including examination rooms, operating rooms, nurse stations, receptions, and patient rooms. Results: The A-weighted equivalent noise level, LAeq, ranges from 54 to 56 dBA, which is at least 10 dB lower than the noise levels of 65 to 73 dBA measured in American ERs. In an ICU, the noise level for the first night was 66 dBA, which came down to 56 dBA for the next day. The noise levels during three different ear surgeries vary from 57 to 62 dBA, depending on the use of surgical drills and suctions. The noise levels in a patient room is found to be 47 dBA, while the nurse stations and the receptions have high noise levels up to 64 dBA. The reverberation times in an operation room, examination room, and single patient room are found to be below 0.6 s. Conclusions: At SNUH, the nurse stations and receptions were found to be quite noisy. The ERs were quieter than in the previous studies. The measured reverberation times seemed low enough but some other nurse stations and examination rooms were not satisfactory according to the questionnaire.

Applicability of American and European Spirometry Repeatability Criteria to Korean Adults (한국 성인을 대상으로 한 미국 및 유럽 폐활량 검사 재현성 기준의 유용성)

  • Park, Byung Hoon;Park, Moo Suk;Jung, Woo Young;Byun, Min Kwang;Park, Seon Cheol;Shin, Sang Yun;Jeon, Han Ho;Jung, Kyung Soo;Moon, Ji Ae;Kim, Se Kyu;Chang, Joon;Kim, Sung Kyu;Ahn, Song Vogue;Oh, Yeon-Mok;Lee, Sang Do;Kim, Young Sam
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.5
    • /
    • pp.405-411
    • /
    • 2007
  • Background: The objective of this study was to evaluate the clinical applicability of the repeatability criteria recommended by the American Thoracic Society/European Respiratory Society (ATS/ERS) spirometry guidelines and to determine which factors affect the repeatability of spirometry in Korean adults. Methods: We reviewed the spirometry data of 4,663 Korean adults from the Korean National Health and Nutritional Examination Survey (KNHANES) Chronic Obstructive Pulmonary Disease Cohort (COPD cohort) and the Community-based Cohort Study VI-Fishing village/Islands (community cohort). We measured the anthropometric factors and differences between the highest and second-highest FVC (dFVC) and $FEV_1$ ($dFEV_1$) from prebronchodilator spirometry. Analyses included the distribution of dFVC and $dFEV_1$, comparison of the values meeting the 1994 ATS repeatability criteria with the values meeting the 2005 ATS/ERS repeatability criteria, and the performance of linear regression for evaluating the influence of subject characteristics and the change of criteria on the spiro-metric variability. Results: About 95% of subjects were able to reproduce FVC and $FEV_1$ within 150 ml. The KNHANES based on the 1994 ATS guidelines showed poorer repeatability than the COPD cohort and community cohort based on the 2005 ATS/ERS guidelines. Demographic and anthropometric factors had little effect on repeatability, explaining only 0.5 to 3%. Conclusion: We conclude that the new spirometry repeatability criteria recommended by the 2005 ATS/ERS guidelines is also applicable to Korean adults. The repeatability of spirometry depends little on individual characteristics when an experienced technician performs testing. Therefore, we suggest that sustained efforts for public awareness of new repeatability criteria, quality control of spirograms, and education of personnel are needed for reliable spirometric results.

Evaluation of QuEChERS Method for Determination of pesticide Residues Using GC/NPD and GC/ECD (GC/NPD와 GC/ECD를 이용한 잔류농약 정량 분석법으로써의 QuEChERS의 평가)

  • Cho, Tae Hee;Park, Young Hye;Park, Hye Won;Hwang, Lae Hwong;Cho, In Soon;Kim, Min Jung;Kim, Hyun Jeong;Kim, Mu Sang;Chae, Young Zoo
    • The Korean Journal of Pesticide Science
    • /
    • v.17 no.1
    • /
    • pp.65-71
    • /
    • 2013
  • The modified QuEChERS method was evaluated for rapid determination of pesticide residues in spinach by gas chromatography-nitrogen phosphorous detector (NPD) and electron capture detector (ECD). Fifty GC-amenable pesticides which were most frequently detected in monitoring were selected in the current study. Matrix-matched calibration was performed. The detector response for all pesticides was linear with determination coefficients higher than 0.995. LODs for most compounds ranged between 0.001 and 0.1 ug/g, and about 90% of the compounds had LODs of less than 0.05 ug/g. LOQs ranged from 0.001 to 0.32 ug/g, which were well below the MRLs permitted for most of pesticides. In the majority of cases, the recoveries (80-120%) and relative standard deviations (RSDs) (less than 20%) were within acceptable levels except for dichlorvos, propamocarb, chlorothalonil, dichlofluanid, cyhalothrin and fenvalerate. Also, this method which is applied to routine samples showed good results when comparing with traditional multi-residue method.

Monitoring of Volcanic Activity of Augustine Volcano, Alaska Using TCPInSAR and SBAS Time-series Techniques for Measuring Surface Deformation (시계열 지표변위 관측기법(TCPInSAR와 SBAS)을 이용한 미국 알라스카 어거스틴 화산활동 감시)

  • Cho, Minji;Zhang, Lei;Lee, Chang-Wook
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.1
    • /
    • pp.21-34
    • /
    • 2013
  • Permanent Scatterer InSAR (PSInSAR) technique extracts permanent scatterers exhibiting high phase stability over the entire observation period and calculates precise time-series deformation at Permanent Scatterer (PS) points by using single master interferograms. This technique is not a good method to apply on nature environment such as forest area where permanent scatterers cannot be identified. Another muti-temporal Interferometric Synthetic Aperture Radar (InSAR), Small BAseline Subset (SBAS) technique using multi master interferograms with short baselines, can be effective to detect deformation in forest area. However, because of the error induced from phase unwrapping, the technique sometimes fails to estimate correct deformation from a stack of interferograms. To overcome those problems, we introduced new multi-temporal InSAR technique, called Temporarily Coherence Point InSAR (TCPInSAR), in this paper. This technique utilizes multi master interferograms with short baseline and without phase unwrapping. To compare with traditional multi-temporal InSAR techniques, we retrieved spatially changing deformation because PSs have been found enough in forest area with TCPInSAR technique and time-series deformation without phase unwrapping error. For this study, we acquired ERS-1 and ERS-2 SAR dataset on Augustine volcano, Alaska and detected deformation in study area for the period 1992-2005 with SBAS and TCPInSAR techniques.

Intertidal DEM Generation Using Satellite Radar Interferometry (인공위성 레이더 간섭기술을 이용한 조간대 지형도 작성에 관한 연구)

  • Park, Jeong-Won;Choi, Jung-Hyun;Lee, Yoon-Kyung;Won, Joong-Sun
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.1
    • /
    • pp.121-128
    • /
    • 2012
  • High resolution intertidal DEM is a basic material for science research like sedimentation/erosion by ocean current, and is invaluable in a monitoring of environmental changes and practical management of coastal wetland. Since the intertidal zone changes rapidly by the inflow of fluvial debris and tide condition, remote sensing is an effective tool for observing large areas in short time. Although radar interferometry is one of the well-known techniques for generating high resolution DEM, conventional repeat-pass interferometry has difficulty on acquiring enough coherence over tidal flat due to the limited exposure time and the rapid changes in surface condition. In order to overcome these constraints, we tested the feasibility of radar interferometry using Cosmo-SkyMed tandem-like one-day data and ERS-ENVISAT cross tandem data with very short revisit period compared to the conventional repeat pass data. Small temporal baseline combined with long perpendicular baseline allowed high coherence over most of the exposed tidal flat surface in both observations. However the interferometric phases acquired from Cosmo-SkyMed data suffer from atmospheric delay and changes in soil moisture contents. The ERS-ENVISAT pair, on the other hand, provides nice phase which agree well with the real topography, because the atmospheric effect in 30-minute gap is almost same to both images so that they are cancelled out in the interferometric process. Thus, the cross interferometry with very small temporal baseline and large perpendicular baseline is one of the most reliable solutions for the intertidal DEM construction which requires very accurate mapping of the elevation.