• 제목/요약/키워드: ERF : 전기 점성 유체

검색결과 8건 처리시간 0.019초

전기점성 유체를 이용한 동력전달 장치에 관한 연구 (A Study on Torque Transmission Using Electro-Rheological Fluid)

  • 주동우;이은준;박명관
    • 한국정밀공학회지
    • /
    • 제15권10호
    • /
    • pp.81-87
    • /
    • 1998
  • This paper provides an investigation of torque transmission system using ERF (Electro-Rheological Fluid). The torque transmission system using ERF is a new conception device because an apparent viscosity of ERF can be changed by applying an electric field, We use the coaxial cylinder type in which the ERF fills the annular space between a pair of coaxial cylindrical electrodes and experiment results show that the measured torque was increased with the increase of the electric field. These are analyzed to provide guidelines to assist in the development of practical ER devices.

  • PDF

ER유체를 이용한 수술용 원격 제어 시스템의 힘 반사 제어부에 관한 연구 (A Study on Force Reflection Controller of Tele-Surgery Control System using ERF)

  • 신진오;이은준;박명관
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.132-135
    • /
    • 2000
  • The development of a robot system being able to work instead of human in the hazardous environment have been conducted for many year. In this study, the new design of controllers for the Master-Slave system is discussed. The Master-Slave system, force, velocity and torque signals are communicated between a master and a slave system. the conventional requires the enhancement of characteristics of tactility for minute force, precision signals and mechanical abrasion of loader. It is possible b controlling the viscosity of ERF(Electro-rheological fluid) since it varies with the electric field. Design of controller as well comparison between numerical simulation and experiments as will be presented. Futhermore, current methodology is also applicable to design of tele-surgery

  • PDF

케미컬오일을 이용한 ERF 연마 특성 (Characteristics of ERF Polishing using Chemical-oil)

  • 윤종호;이재종;이응숙;이동주;김영호
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 춘계학술대회 논문집
    • /
    • pp.27-33
    • /
    • 2004
  • Electro-theological fluid is recently used for the micro polishing of 3-dimensional micro-aspherical lens. It's also used for polishing small area defects on the wide flat wafer. Since ER fluid shows a behavior of viscosity changing under certain electric fields. micro polishing efficiency may be enhanced for certain cases. In this paper, a perfluorinated carbonyl fluoride oil based ER fluids was used to improve surface polishing rate and submicron-scale accuracy. As the polishing electrodes, micro size cylindrical tools had been used for maximizing the electric field. An experimental device, which was applied for micro polishing a number of wafers of 4inches in size and other workpiece. was made on a precision polishing system. It consisted of a steel electrode. a wafer fixture. l0㎃ current and DC 5㎸ power supply unit, and a controller unit. From the Experiments. the ER fluid is applicable for micro polishing of small parts.

  • PDF

PIV 기법을 이용한 ER 유체의 유동특성에 관한 실험적 연구 (Experimental Study on Flow Characteristics of ERF by using PIV Technique)

  • 장태현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권1호
    • /
    • pp.116-123
    • /
    • 2004
  • An experimental investigation was performed to study the characteristics of ER (Electro-Rheological) fluid flow in a horizontal rectangular tube with or without D.C volatage. To determine some characteristics of the ER flow. 2D PIV(Particle Image Velocimetry) technique is employed for velocity measurement. This research found the mean velocity distribution with 0 kV/mm. 1.0kV/mm and 1 5kV/mm for Re=0, 0.62, 1.29 and 2.26. When the strength of the electric field increased. the claster of ERF are clearly strong along the test tube and the flow rate decreased.

ER클러치의 성능실험에 관한 기초적 연구 (Fundamental Study on Performance Experiment of ER Clutch)

  • 김도태;장성철;염만오;김태형
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 춘계학술대회 논문집(한국공작기계학회)
    • /
    • pp.66-71
    • /
    • 2001
  • In this work, an ER clutch has been constructed and its characteristics have been evaluated by adapting an electro-rheological fluid(ERF) as an operating medium. ER fluids are suspensions which show an abrupt increase in rheological properties under electric fields. An ER clutch system using ER fluid is a new conception device because an apparent viscosity of ER fluid can be changed by apply an electric field. As a first, Bingham properties of ER fluids are experimentally distilled as a function of electric field. We use the disk type ER clutch in which the ER fluid fills the annular space between a pair of coaxial disk electrodes and experiment results show that the measured revolution per minute was increased with the increase of the electric field. The ER fluid used in the present study consists of weight fraction 35% in zeolite suspended silicone oil.

  • PDF

3 포트 ERF 밸브의 유량-방향 제어 성능 실험 -유압시스템 및 자동화 융합연구- (Performance Test of 3 Port ERF Valve for Controlling Flow Rate-Direction)

  • 장성철
    • 동력기계공학회지
    • /
    • 제16권6호
    • /
    • pp.92-97
    • /
    • 2012
  • In this study, ER fluids were working fluid and yield shear stress of attained dispersive ER fluids made by analyzed to adapt effectively at the practical equipment like three port ER valve. In addition, movement of ER particle was observed by using a microscope the same as the strength of electric field with Bingham characteristic. Basis material was presented to develop 3 port ER-Valve by quantitatively comparing and analyzing entrance, load and outlet flow's differences of 3 port rectangular tubes. This study, after designing and producing the 3port ER-Valve, considered the characteristic of pressure drop, outlet and load flow rate by changing the strength of electric field on ER fluids flowing between electrodes.

ERF를 이용한 유압제어밸브의 특성실험 (Characteristic Experiment of a Hydraulic Control Valve by Using Electro-Rheological Fluid)

  • 김동수;박재범;장성철
    • 연구논문집
    • /
    • 통권30호
    • /
    • pp.93-99
    • /
    • 2000
  • Electro-Rheological(ER) fluids change their apparent viscosity according to the electric field strength. The electrical and rheological properties of zeolite based the ER fluids were reported. The electric field dependent yield stress are obtained from experimental investigation on the Bingham property of the ER fluid. Using ER fluids, it is possible to directly interface between electric drop and flow rate of the ER fluid was hydraulic control valve measured under application of an electric field. The purpose of the present study is pressure drop measurement of an ER valve by using strain gage. The performance characteristics of the valve system are evalusted in terms of pressrue fixed with respect to the intensity of employed electric fields and flow rates. As a result, it is esperimentally confirmed that pressure control valve using ER fluids applicable to use in hydraulic power systems.

  • PDF

회전식 점도계를 이용한 ERF의 겉보기 점도 특성 (Apparent Viscosity Properties of Electro-Rheological Fluid by Using Rotational Viscometer)

  • 장성철;이진우;김태형;박종근
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.196-201
    • /
    • 2001
  • Electro-Rheological(ER) fluids change their apparent viscosity according to the electric field strength. Therefore, there are many practical applications using the ER fluids. ER effect on the dispersive system of polarizable fine powder/dielectric oil has been investigated. The electrical and rheological properties of starch based ER fluid were reported. Yield stress of the fluids were measured on the couette cell type rheometer as a function of electric fields, particle concetrations, and temperatures. The electric field is applied by high voltage DC power supply, The outer cup is connected to positive electrode(+) and the bob becomes ground(-). And the temperatures the viscosity(or shear stress) versus shear rates were measured. In this experiment shear rates were increased from 0 to 200s$^{-1}$ in 2 minutes. This thesis presents Bingham properties of ER fluids subjected to temperature variations. The temperature dependence of the viscosity was determined for ER fluids consisting of 35 weight % starch particles in automatic transmission oil.

  • PDF