• Title/Summary/Keyword: ER fluid

Search Result 229, Processing Time 0.02 seconds

Experimental Investigation on the Flow Characteristics of ER Fluids III (3nd Report, Flow-Pressure Drop Characteristics clearance between Two Parallel Plate) (ER유체의 유동특성에 관한 실험적 연구 III (평행평판 간극내의 유량-압려강하 특성))

  • 김도태
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.399-404
    • /
    • 1999
  • Electro-rheological(ER) fluids are suspensions which show an abrupt increase in rheological properties under electric fields. The rheological response is very rapid and reversible when the electric field is imposed and/or removed. Therefore, there are many practical applications using the ER fluids. The purpose of the present study is to examine the flow characteristics of electro-rheological fluids. The field-dependent yield stress are obtained from experimental investigation on the Bingham property of the ER fluid. Then the steady relationshup between pressure drop and flow rate of the ERF was two fixed parallel-plates was measured under application of an electric fields. The electrical and rheological properties of zeolite based electro-rheological fluids were reported.

  • PDF

Electrorheological Effect of the Suspension Composed of Bismark Brown Chitosan Succinate as the Dispersed Phase

  • Choi, Ung-Su
    • KSTLE International Journal
    • /
    • v.8 no.2
    • /
    • pp.21-25
    • /
    • 2007
  • The electrorheological effect of the suspension composed of Bismark Brown chitosan succinate as the dispersed phase in silicone oil was investigated. Bismark Brown chitosan succinate suspension showed a typical ER response (Bingham flow behavior) upon application of an electric field. The shear stress for the suspension exhibited the dependence with a factor equals to 1.84 power on the electric field. The experimental results for the suspension correlated with the polarization model and Bismark Brown chitosan succinate suspension behaved as an anhydrous ER fluid. On the basis of the results, Bismark Brown chitosan succinate suspension showed the ER flow behavior upon application of the electric field due to the polarizability of the branched amide and amine polar groups of the Bismark brown chitosan succinate particles.

A Dynamic Simulation on the Squeezing Flow of ER Fluids (전기유변 유체의 압착유동에 대한 동적 수치모사)

  • 김도훈;주상현;안경현;이승종
    • The Korean Journal of Rheology
    • /
    • v.11 no.2
    • /
    • pp.82-90
    • /
    • 1999
  • Electrorheological(ER) fluid is a material that shows the dramatic change of rheological properties under an electric field and responds reversibly in a few milliseconds. ER fluid's response to an electric field along with its fast switching capability allows ER devices to be precisely controlled. The real application with ER fluid, however, has many limitations to be overcome; temperature fluctuation, moisture, dust, aggregation, precipitation, and low yield stress, for example. The magnitude and the characteristics of yield stress of ER fluid plays an important role in practical applications. In this research, a dynamic simulation on the squeezing flow of the ER fluid was carried out. Numerical simulation on isolated chains was performed to find out the effect of hydrodynamic and electrostatic force depending on the chain location, the squeezing rate, and the chain structure. Suspension model that is composed of a large number of particles was also investigated. The increase of normal stresses as well as the existence of a yield stress at an earlier stage could be observed, and the effective control of the normal stresses could be achieved at an optimal condition of the hydrodynamic force and the electrostatic force.

  • PDF

An Analysis and Test Results of Damping Characteristics of ER Dampers with Two Different Valve Types (ER 댐퍼의 밸브 형상에 따른 감쇠 특성의 해석 및 실험)

  • 장보영;이종민;김창호;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.608-613
    • /
    • 1998
  • Damping characteristics of ER dampers and flow rates inside ER valve with two different valve types were analyzed and compared with test results. Fluid flow inside ER valves was modeled by Bingham plastic model and Hagen-Poiseulli flow, while the equations of motion of total ER damper system were modeled by flow and hydraulic force balance. A general straight valve case was compared with a bended valve case which is newly tested for a possible improvement of ER damping force. As expected, the bended ER valve generates higher damping force and lower flow rates than the conventional straight ER valve due to additional flow restriction at the bended section. Analytical models of ER valve and ER damper generally predict reasonable performance characteristics of tested results. Therefore, developed analysis can be used for designing new ER dampers and simulation of ER semi-active suspension system as well.

  • PDF

Performance Evaluation of a Mixed-Mode Type ER Engine Mount (I);Manufacturing and Test of Engine Mount (복합모드형 ER엔진마운트의 성능평가 (I);엔진마운트의 제작 및 시험)

  • Choe, Yeong-Tae;Choe, Seung-Bok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.2 s.173
    • /
    • pp.370-377
    • /
    • 2000
  • This paper presents a mixed-mode type ER(electro-rheological) engine mount, and its vibration control performance for a passenger vehicle is presented. The field-dependent yield stress of a transfo rmer oil-based ER fluid is empirically distilled in both shear and flow modes. This is then incorporated with the governing equation of motion of the proposed mixed-mode(shear mode plus flow mode) type engine mount. The damping force is analyzed with respect to the intensity of the electric field and design parameters such as electrode gap. Subsequently, the ER engine mount which is equivalent to the conventional hydraulic engine mount in terms of the damping level is designed and manufactured. Both computer simulation and experimental test are undertaken in order to evaluate vibration isolation performance. In addition, this performance is compared with that of the conventional hydraulic engine mount.

Vibration Control of CD-ROM Feeding System Using ER Fluids (ER 유체를 이용한 CD-ROM 피딩 시스템의 진동 제어)

  • 김형규;임수철;최승복;박영필
    • The Korean Journal of Rheology
    • /
    • v.11 no.2
    • /
    • pp.97-104
    • /
    • 1999
  • This paper presents vibration control of a drive feeding system consisting of a new type of CD-ROM(compact discread only memory) mount using electro-rheologocal(ER) fluid. Chemically treated starch particles and silicon oil are used for ER fluid. and its field-dependent yield stresses are experimentally distilled under both the shear and the flow modes. On the basis of the yield stress, an appropriate size of ER CD-ROM mount adapted to conventional feeding system is designed and manufactured. Vibration isolation performance of the proposed mount is evaluated in the frequency domain and compared with that of conventional rubber mount. The ER CD-ROM mount is then installed to the drive feeding system and the system equation of motion is derived. Following the formulating the sky-hook controller, computer simulation is undertaken in order to evaluate vibration suppression of the feeding system subjected to various disturbances(excitations).

  • PDF

A Study on the Mechanism of Clusters Formation of ER Fluids (ER유체의 클러스터 형성 메커니즘에 관한 연구)

  • Rhee Eun-Jun.;Park Myeong-Kwan.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.503-506
    • /
    • 2002
  • Electrorheological fluids(ERFs) show a rapid and reversible increase in viscosity by applied electric field. It is called the electrorheological effect (ER effect). The reason for ER effect is the induction of an electric dipole in each particle, leading to the formation of clusters in the direction of the field, which resist fluid flow. Generally, the behavior of ER fluids has been modeled on those of Bingham fluids. But there are some differences between Bingham fluids and ER fluids. The visualization of ER fliuds are presented and ER effects by the forming, growing and breaking of clusters are discussed. In the low shear rate area, the pressure drop is measured by a pressure sensor and the formation of ER particles is visualized by video camera. The reason for the nonlinear behavior of ER fluids at low shear rate is explained through results of visualization.

  • PDF

Field-Dependent Characteristics of ER Shock Damper (ER 유체를 이용한 충격절연 댐퍼의 특성 연구)

  • 송현정;최승복;김재환;김경수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.109-114
    • /
    • 2001
  • This paper presents field-dependent dynamic characteristics of a shock damper featuring an electro-rheological(ER) damper. A cylindrical type of the shock damper is designed and manufactured on the basis of the field-dependent Bingham model. The damping force is then measured with respect to the piston velocity at various electric fields. The measured damping force is incorporated with the 1DOF shock system to analyze the shock isolation performance.

  • PDF

Damping Force Characteristics of ER Damper Considering Hysteresis (ER 댐퍼의 이력현상을 고려한 댐핑력 특성 고찰)

  • 홍성룡;송현정;한상수;최승복
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.489-494
    • /
    • 2002
  • This paper presents hydraulic model which can capture the hysteric damping force behavior of ER damper. A flow mode rue ER damper is manufactured, and its field-dependent damping forces are measured. Newly proposed hydraulic model which derived from physical hydro-mechanical parameters of ER damper are conventional Bingham model are investigated to represent the field-dependent damping force characteristics of ER damper. After principal parameters of two models are estimated from the measured damping forces data, the force vs velocity hysteresis cycles are then reconstructed. The results show that the proposed hydraulic model can capture the hysteresis behavior of ER damper accurately.

  • PDF

Durability Estimation for ER(Electro-Rheological) Fluids of Arabic Gum Components (아라빅 검 성분의 ER유체에 대한 내구성 평가)

  • Kim, O.S.;Park, W.C.
    • Journal of Power System Engineering
    • /
    • v.5 no.4
    • /
    • pp.61-66
    • /
    • 2001
  • Electro-Rheological(ER) fluids undergo a phase-change when subjected to an external electric field, and this phase-change typically manifests itself as a many-order-of magnitude change in the rheological behavior. This paper presents experimental results on material properties for an ER fluids of arabic gum components subjected to electrical fatigues. As a first step, ER fluids are made of arabic gum 25% of particle weight-concentration. Following the construction of test mechanism for estimated durability of ER fluid, the dynamic yield stress, shear stress and current density of the ER fluids are experimentally distilled as a function of DC electric field. The durability estimation of operated ER fluids are distilled and compared with those of unused ER fluids. In addition, the surface roughness of the employed electrode for copper and aluminum are evaluated as a function of the number of the electric-field cycles.

  • PDF