• Title/Summary/Keyword: EPI

Search Result 543, Processing Time 0.023 seconds

Intravenous Patient-Controlled Analgesia with Nalbuphine: Could be an Alternative to Epidural Patient-Controlled Analgesia with Morphine-Bupivacaine for Pain Relief after Cesarean Delivery? (제왕절개술후 자가진통법을 이용한 정맥내 Nalbuphine은 경막외 Morphine과 Bupivacaine 혼합제를 대치할 수 있나?)

  • Lee, Jong-Seok;Lee, Youn-Woo;Yoon, Duck-Mi;Nam, Yong-Taek;Song, Keun-Ho
    • The Korean Journal of Pain
    • /
    • v.10 no.1
    • /
    • pp.34-41
    • /
    • 1997
  • Background : Patient-controlled analgesia(PCA) is a safe and effective technique for providing postoperative pain relief. Studies that compare epidural vs intravenous routes of opiate administration show conflicting results. We designed a prospective, randomized, controlled study to evaluate the safety and efficacy of epidural(EPI-PCA) morphine-bupivacaine versus intravenous (IV-PCA) nalbuphine when administered with a PCA system. Methods : Forty healthy women were randomly assigned to receive an epidural bolus of morphine 3 mg and 0.5% bupivacaine 10 ml, followed by a EPI-PCA with 0.01% morphine and 0.143% bupivacane (basal infusion 1 ml/hr, bolus 1 ml, lock-out interval 30 min) or intravenous bolus of nalbuphine 0.1 mg/kg followed by a IV-PCA with nalbuphine(basal infusion 1 mg/hr, bolus 1 ml, lock-out interval 20 min) for pain relief after cesarean delivery. This study was conducted for 2 days after cesarean section to compare the analgesic efficacy, side effects, patient satisfaction either as EPI-PCA or as IV-PCA. Results : EPI-PCA group had significant lower visual analog pain scale(VAS) at immediate postoperative period, whereas no significant difference was observed when pain was assessed at other time sequence. Urinary retention and pruritus were more frequent with EPI-PCA group, although the incidence of other side effects were the same. Conclusions : Although EPI-PCA with morphine-bupivacaine was of significantly lower VAS at immediate postoperative period, IV-PCA with nalbuphine is a safe and effective alternative to EPI-PCA with morphine-bupivacaine for providing pain relief after cesarean delivery. Further studies about IV-PCA with nalbuphine are needed to control the immediate postoperative pain and to further improve effective pain management.

  • PDF

Accelerated Resting-State Functional Magnetic Resonance Imaging Using Multiband Echo-Planar Imaging with Controlled Aliasing

  • Seo, Hyung Suk;Jang, Kyung Eun;Wang, Dingxin;Kim, In Seong;Chang, Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.4
    • /
    • pp.223-232
    • /
    • 2017
  • Purpose: To report the use of multiband accelerated echo-planar imaging (EPI) for resting-state functional MRI (rs-fMRI) to achieve rapid high temporal resolution at 3T compared to conventional EPI. Materials and Methods: rs-fMRI data were acquired from 20 healthy right-handed volunteers by using three methods: conventional single-band gradient-echo EPI acquisition (Data 1), multiband gradient-echo EPI acquisition with 240 volumes (Data 2) and 480 volumes (Data 3). Temporal signal-to-noise ratio (tSNR) maps were obtained by dividing the mean of the time course of each voxel by its temporal standard deviation. The resting-state sensorimotor network (SMN) and default mode network (DMN) were estimated using independent component analysis (ICA) and a seed-based method. One-way analysis of variance (ANOVA) was performed between the tSNR map, SMN, and DMN from the three data sets for between-group analysis. P < 0.05 with a family-wise error (FWE) correction for multiple comparisons was considered statistically significant. Results: One-way ANOVA and post-hoc two-sample t-tests showed that the tSNR was higher in Data 1 than Data 2 and 3 in white matter structures such as the striatum and medial and superior longitudinal fasciculus. One-way ANOVA revealed no differences in SMN or DMN across the three data sets. Conclusion: Within the adapted metrics estimated under specific imaging conditions employed in this study, multiband accelerated EPI, which substantially reduced scan times, provides the same quality image of functional connectivity as rs-fMRI by using conventional EPI at 3T. Under employed imaging conditions, this technique shows strong potential for clinical acceptance and translation of rs-fMRI protocols with potential advantages in spatial and/or temporal resolution. However, further study is warranted to evaluate whether the current findings can be generalized in diverse settings.

Properties of Defective Regions Observed by Photoluminescence Imaging for GaN-Based Light-Emitting Diode Epi-Wafers

  • Kim, Jongseok;Kim, HyungTae;Kim, Seungtaek;Jeong, Hoon;Cho, In-Sung;Noh, Min Soo;Jung, Hyundon;Jin, Kyung Chan
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.687-694
    • /
    • 2015
  • A photoluminescence (PL) imaging method using a vision camera was employed to inspect InGaN/GaN quantum-well light-emitting diode (LED) epi-wafers. The PL image revealed dark spot defective regions (DSDRs) as well as a spatial map of integrated PL intensity of the epi-wafer. The Shockley-Read-Hall (SRH) nonradiative recombination coefficient increased with the size of the DSDRs. The high nonradiative recombination rates of the DSDRs resulted in degradation of the optical properties of the LED chips fabricated at the defective regions. Abnormal current-voltage characteristics with large forward leakages were also observed for LED chips with DSDRs, which could be due to parallel resistances bypassing the junction and/or tunneling through defects in the active region. It was found that the SRH nonradiative recombination process was dominant in the voltage range where the forward leakage by tunneling was observed. The results indicated that the DSDRs observed by PL imaging of LED epi-wafers were high density SRH nonradiative recombination centers which could affect the optical and electrical properties of the LED chips, and PL imaging can be an inspection method for evaluation of the epi-wafers and estimation of properties of the LED chips before fabrication.

Rational Building Energy Assessment using Global Sensitivity Analysis (전역 민감도 분석을 이용한 건물 에너지 성능평가의 합리적 개선)

  • Yoo, Young-Seo;Yi, Dong-Hyuk;Kim, Sun-Sook;Park, Cheol-Soo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.5
    • /
    • pp.177-185
    • /
    • 2020
  • The building energy performance indicator, called Energy Performance Index (EPI), has been used for the past decades in South Korea. It has a list of design variables assigned with weighting factors (a, b). Unfortunately, the current EPI method is not performance-based but very close to a prescriptive rating. With this in mind, this study aims to propose a new performance-based EPI method. For this purpose, a global sensitivity analysis method, Sobol, is employed. The Sobol method is suitable for complex nonlinear models and can decompose all the output variance due to every input. The Sobol sensitivity index of each variable is defined as 0 to 1 (0 to 100%), and the sum of all sensitivity indices is equal to 1 (100%). In this study, an office building was modeled using EnergyPlus and then the Latin Hypercube Sampling (LHS) was conducted to generate a surrogate model to EnergyPlus. The sensitivity index was suggested to replace weight (a) in the existing EPI. In addition, the discrete weight (b) in the existing EPI was replaced by a set of continuous regression functions. Due to the introduction of the sensitivity index and the continuous regression functions, the new proposed approach can provide far more accurate outcome than the existing EPI (R2: 0.83 vs. R2: 0.01 for cooling, R2: 0.66 vs. R2: 0.01 for total energy). The new proposed approach proves to be more rational, objective and performance-based than the existing EPI method.

A Synthesis of Combinational Logic with TANT Networks (조합논리함수의 TANT회로에 의한 합성)

  • 고경식
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.5 no.4
    • /
    • pp.1-8
    • /
    • 1968
  • A TANT network is a three-level network composed solely of NAND gates having only true(i.e. uncomplemented) inputs. The paper presents a technique for finding for any given Boolean function a least-cost TANT network. The first step of the technique is to determine essential prime implicants(EPI) by Quine-McCluskey procedure or other methods and generate prime implicants(PI) hving the same head as any one of EPI by consensus operation. The second step is to select common factors among the usable tail factors. The selcetion phase is analogous to the use of C-C table. The last step is to minimize inputs by deleting the redundant PI. the technique permits hand solution of typical five-and six-variable problems.

  • PDF

Relationship Between Brain Injury and Head Circumference Growth in Extremely Premature Infants (중증 미숙아의 뇌병변과 머리둘레 성장 간의 관계)

  • Ahn, Young-Mee;Lee, Sang-Mi
    • Child Health Nursing Research
    • /
    • v.17 no.4
    • /
    • pp.281-287
    • /
    • 2011
  • Purpose: The study was done to explore growth variation in head circumference (HC) in extremely premature infants (EPI) with brain injury. Methods: A retrospective cohort study was conducted with 79 cohort samples from the archives of the catch-up growth project. Mean age of the infants was 29.2 weeks of gestation and mean HC, 27.1 cm at birth. Their HC measurements were retrieved from the archives up to 6 month of corrected age (CA) and analyzed against history of brain injury during hospitalization. Results: Overall growth retardation in HC was observed in the cohort sample compared to longer gestation premature infants. EPI with brain injury showed decreased HC compared to infants without brain injury, and resulting growth variation across 6 month of CA. Highest retardation in HC growth was observed in male infants with brain injury. Conclusion: Extreme preterm birth itself may function as a major obstacle against HC growth toward term age in EPI. Sustainability of brain injury could be observed with higher HC growth retardation after term. Evolutionary favor to female infants may exist in HC growth of EPI. Intensive education on HC monitoring is highly suggested for parents of EPI, particularly with children with brain injury.

Analysis for Threshold-voltage of EPI MOSFET (EPI MOSFET의 문턱 전압 특성 분석)

  • 김재홍;고석웅;임규성;정학기;이종인
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.665-668
    • /
    • 2001
  • As reducing the physical size of devices, we can integrate more devices per the unit chip area and make its speed better. We have investigated MOSFET built on an epitaxial layer(EPI) of a heavily-doped ground plane. We compared and analyzed the characteristics of such device structure, i.e., impact ionization, electric field and I-V characteristics curve with lightly-doped drain(LDD) MOSFET. We simulated MOSFET with gate lengths from 0.10 to 0.06${\mu}{\textrm}{m}$ step 0.01${\mu}{\textrm}{m}$ in according to constant voltage scaling theory.

  • PDF

Synthesis of New Semisynthetic Analogs of Epi-xanthatin by Modification of the Side Chain and Their Cytotoxic Activity (Epi-xanthatin의 Side Chain 변환을 통한 새로운 반합성 유도체들의 합성 및 세포독성)

  • Baek Du-Jong;Ahn Jong-Woong;Lee Chongock
    • YAKHAK HOEJI
    • /
    • v.49 no.1
    • /
    • pp.68-73
    • /
    • 2005
  • Epi-xanthatin analogs containing hydrophilic substituents such as carboxylic acid, alcohol, morpholine, amino acid, and glucose derivatives were synthesized and their in vitro cytotoxicity and in vivo antitumor activity were evaluated. The target compounds were generally cytotoxic against tumor cell lines of human origin with $ED_{50}$ values of $0.1{\sim}30{\mu}g/ml$, except the highly hydrophilic analog 6 containing aspartic acid. Contrary to the potent cytotoxicity weakly hydrophilic analogs 2 and 8 were not active in vivo, or even toxic to the test animals. As a result, hydrophilic analog of epi-xanthatin did not show in vitro cytotoxicity and hydrophobic analogs did not show in vivo antitumor activity, thus it is presumed that amphiphilic analogs or those with medium hydrophilicity would exhibit the antitumor potency in vivo.

DEM generation from an IKONOS stereo pair using EpiMatch and Graph-Cut algorithms

  • Kim, Tae-Jung;Im, Yong-Jo;Kim, Ho-Won;Kweon, In-So
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.524-529
    • /
    • 2002
  • In this paper, we report the development of two DEM (digital elevation model) generation algorithms over urban areas from an IKONOS stereo pair. One ("EpiMatch") is originally developed for SPOT images and modified for IKONOS images. It uses epipolar geometry for accurate DEM generation. The other is based on graph-cut algorithm in 3D voxel space. This algorithm is believed to work better on height discontinuities than EpiMatch. An IKONOS image pair over Taejon city area was used for tests. Using ground control points obtained from differential GPS, camera model was set up and stereo matching applied. As a result, two DEMs over urban areas were produced. Within a DEM from EpiMatch small houses appear as small "cloudy" patches and large apartment and industrial buildings are visually identifiable. Within the DEM from graph-cut we could achieve better height information on building boundaries. The results show that both algorithms can generate DEMs from IKONOS images although more research is required on handling height discontinuities (for "EpiMatch") and on faster computation (for "Graph-cut").

  • PDF