• Title/Summary/Keyword: EPE

Search Result 27, Processing Time 0.026 seconds

공제조합 재활용 지정 사업자 명단

  • Korea Foam-Styrene Recycling Association
    • 환경사랑
    • /
    • s.43
    • /
    • pp.8-9
    • /
    • 2006
  • 환경부 비영리 사단법인으로 등록된 당 협회는 2003년 부터 시행하고 있는 생산자 책임 재활용제도의 발포합성수지(EPS, EPP, EPE 등) 재활용 사업 공제조합을 운영하고 있으며 자원의 절약과 재활용 촉진에 관한 법률 규정에 따라 발포합성수지 생산자의 재활용 의무를 대행코자 지자체 재활용 사업자 88개소와 민간 재활용 사업자 41개소를 지정 하였다.

  • PDF

동전기 정화 처리 효율 향상과 후처리 겸용 전극부(EPE) 개발

  • 김강호;한상재;김수삼
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.275-278
    • /
    • 2002
  • In this study, to increase removal efficiency of traditional electrokinetic treatment and to reduce contaminant load of wastewater that discharged through cathode compartment, enhanced electrode compartments were investigated. Hydroxide precipitation near the cathode electrode that encounter during traditional electrokinetic treatment were prevented by enhanced electrokinetic remediation test with newly invented electrode compartment. And heavy metal concentration in wastewater showed 0 ppm thus, additive post-treatment cost were not needed.

  • PDF

Compact See-though Near to Eye Display with Diffractive Optical Elements

  • Levola, Tapani
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1749-1752
    • /
    • 2007
  • The Near to Eye Display (NED) solves the problem of having a display larger than a small portable device. The virtual image of the NED is created using a microdisplay and imaging optics. It is important that the optics does not interfere with the human visual system and that the device is light, compact and easy to wear. In this paper the principles of a biocular NED, which is based on a novel diffractive Exit Pupil Expander (EPE), are presented. The optical system is compact and intrinsically free from distortions and misalignments.

  • PDF

The characterization of electronic materials (전자재료의 특성분석)

  • 박인식
    • Electrical & Electronic Materials
    • /
    • v.8 no.5
    • /
    • pp.658-663
    • /
    • 1995
  • 전자재료라 총칭하는 재료의 종류는 셀 수 없을 정도로 많다. 대표적인 전자재료로는 반도체재료를 들 수 있으며 다음으로는 전기광학 소자의 재료로 쓰이는 여러가지 광학용 단결정, 그리고 저항이나 축전지 등의 제조에 사용되는 여러가지 재료들도 이에 포함된다. 이러한 전자재료의 특성을 평가하는 방법도 여러가지 있겠으나 여기에서는 그 범위를 임의로 반도체레이저의 제조에 사용되는 화합물반도체에 국한시켜 각 공정별로 이떠한 평가방법이 사용되는지, 그리고 각각의 특성평가 방법에 대하여 간략하게 알아보기로 한다.

  • PDF

Nomogram Models for Distinguishing Intraductal Carcinoma of the Prostate From Prostatic Acinar Adenocarcinoma Based on Multiparametric Magnetic Resonance Imaging

  • Ling Yang;Xue-Ming Li;Meng-Ni Zhang;Jin Yao;Bin Song
    • Korean Journal of Radiology
    • /
    • v.24 no.7
    • /
    • pp.668-680
    • /
    • 2023
  • Objective: To compare multiparametric magnetic resonance imaging (MRI) features of intraductal carcinoma of the prostate (IDC-P) with those of prostatic acinar adenocarcinoma (PAC) and develop prediction models to distinguish IDC-P from PAC and IDC-P with a high proportion (IDC ≥ 10%, hpIDC-P) from IDC-P with a low proportion (IDC < 10%, lpIDC-P) and PAC. Materials and Methods: One hundred and six patients with hpIDC-P, 105 with lpIDC-P and 168 with PAC, who underwent pretreatment multiparametric MRI between January 2015 and December 2020 were included in this study. Imaging parameters, including invasiveness and metastasis, were evaluated and compared between the PAC and IDC-P groups as well as between the hpIDC-P and lpIDC-P subgroups. Nomograms for distinguishing IDC-P from PAC, and hpIDC-P from lpIDC-P and PAC, were made using multivariable logistic regression analysis. The discrimination performance of the models was assessed using the receiver operating characteristic area under the curve (ROC-AUC) in the sample, where the models were derived from without an independent validation sample. Results: The tumor diameter was larger and invasive and metastatic features were more common in the IDC-P than in the PAC group (P < 0.001). The distribution of extraprostatic extension (EPE) and pelvic lymphadenopathy was even greater, and the apparent diffusion coefficient (ADC) ratio was lower in the hpIDC-P than in the lpIDC-P group (P < 0.05). The ROC-AUCs of the stepwise models based solely on imaging features for distinguishing IDC-P from PAC and hpIDC-P from lpIDC-P and PAC were 0.797 (95% confidence interval, 0.750-0.843) and 0.777 (0.727-0.827), respectively. Conclusion: IDC-P was more likely to be larger, more invasive, and more metastatic, with obviously restricted diffusion. EPE, pelvic lymphadenopathy, and a lower ADC ratio were more likely to occur in hpIDC-P, and were also the most useful variables in both nomograms for predicting IDC-P and hpIDC-P.

A Study on Dynamic Stiffness of Multi-layered Damping Materials (완충재의 구성에 따른 동탄성계수 변화에 관한 연구)

  • Im, Jung-Bin;Chung, Jin-Yeon;Kim, Kyoung-Woo;Jeong, Gab-Cheol
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1149-1152
    • /
    • 2007
  • Many kind of damping materials are generally used on concrete slab in apartment building to reduce floor impact noise level. Lately, multi-layered damping material that is consist of several materials are used to improve the effect of floor impact noise insulation. In this study, dynamic stiffness of multi-layered damping material that is consist of common materials such as expanded polystyrene(EPS), expended polyethylene(EPE), ethylene vinyl acetate(EVA) and polyester was investigated. It was found that dynamic stiffness of multi-layered damping material could be estimated if know value of each layer that compose whole structure. And it was found that dynamic stiffness of whole structure did not change even if change order that build layer.

  • PDF

Performance Evaluation of Wavelet-based ECG Compression Algorithms over CDMA Networks (CDMA 네트워크에서의 ECG 압축 알고리즘의 성능 평가)

  • 김병수;유선국
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.9
    • /
    • pp.663-669
    • /
    • 2004
  • The mobile tole-cardiology system is the new research area that support an ubiquitous health care based on mobile telecommunication networks. Although there are many researches presenting the modeling concepts of a GSM-based mobile telemedical system, practical application needs to be considered both compression performance and error corruption in the mobile environment. This paper evaluates three wavelet ECG compression algorithms over CDMA networks. The three selected methods are Rajoub using EPE thresholding, Embedded Zerotree Wavelet(EZW) and Wavelet transform Higher Order Statistics Coding(WHOSC) with linear prediction. All methodologies protected more significant information using Forward Error Correction coding and measured not only compression performance in noise-free but also error robustness and delay profile in CDMA environment. In addition, from the field test we analyzed the PRD for movement speed and the features of CDMA 1X. The test results show that Rajoub has low robustness over high error attack and EZW contributes to more efficient exploitation in variable bandwidth and high error. WHOSC has high robustness in overall BER but loses performance about particular abnormal ECG.

Optical Proximity Corrections for Digital Micromirror Device-based Maskless Lithography

  • Hur, Jungyu;Seo, Manseung
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.221-227
    • /
    • 2012
  • We propose optical proximity corrections (OPCs) for digital micromirror device (DMD)-based maskless lithography. A pattern writing scheme is analyzed and a theoretical model for obtaining the dose distribution profile and resulting structure is derived. By using simulation based on this model we were able to reduce the edge placement error (EPE) between the design width and the critical dimension (CD) of a fabricated photoresist, which enables improvement of the CD. Moreover, by experiments carried out with the parameter derived from the writing scheme, we minimized the corner-rounding effect by controlling light transmission to the corners of a feature by modulating a DMD.

Effects of the Selective Eye Movement Program on the Foot Pressure and Balance in Normal Adults (선택적 안구운동 프로그램이 정상성인의 족저압과 균형에 미치는 영향)

  • Lee, Geon-Cheol;Kim, Chi-Hyok;Kim, Myung-Jin;Jung, Go-Woon;Lee, Jae-Cheol;Kim, Ji-Hwan;Lee, Mi-Hwa;Kim, Ji-Sun;Bae, Won-Sik
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.4
    • /
    • pp.425-436
    • /
    • 2011
  • Purpose : The purpose of this study is to identify static, dynamic balance performances and foot pressure after eye movement exercise in normal adults. Method : This study was performed on normal 18 males and 18 females subjects. They were divided into 3 groups using random sampling and executed saccadic eye movement, vestibuloocular eye movement, pursuit vergence eye movement exercise respectively. In order to compare the difference of balance and foot pressure, the subjects were measured before, middle and after eye movement. Balance was examined using the balance master 7.0 version systems. Foot pressure was examined using the gaitview AFA-50. Result : The result are as follows. 1. After first intervention, the difference of the FORM-EC item on MCTSIB variable in the vestibuloocular group was significantly decreased(p<.05) and after second intervention, the difference of the FIRM-EO(p<.05), FORM-EO(p<.01), FORM-EC(p<.01) items on MCTSIB variable in the saccadic group and FORM-EC(p<.05) item in the vestibuloocular group were significantly decreased respectively. 2. After first intervention, the difference of the EPE, MXE items in the saccadic group(p<.05) and RT(p<.05), EPE(p<.01) items in the pursuit vergence group were significantly decreased respectively after second intervention. 3. After first intervention, the difference of the Static A-P(p<.05), L-R(p<.01) and Dynamic A-P(p<.01), L-R (p<.01) items on foot pressure variable in the saccadic group, Dynamic A-P(p<.01) item in the vestibuloocular group and Static A-P(p<.01), Dynamic A-P(p<.05), L-R(p<.01) items in the pursuit vergence group were significantly decreased respectively. 4. After first intervention, the difference of the FORM-EO(p<.05), FORM-EC(p<.01) items and after second intervention, the difference of the FIRM-EO(p<.01) item on MCTSIB variable among three groups was significantly decreased respectively. Conclusion : Selective eye movement exercise program influences balance control ability and foot pressure of normal adults in positive ways.

Acoustic Comparisons of Vowel and Plosive Productions between the Normal and the Hearing-Impaired Children (청각장애아동과 건청아동의 모음 및 파열음 산출의 음향음성학적 특성 비교)

  • Oh, Y.J.;Zhi, M.Z.;Kim, Y.T.
    • Speech Sciences
    • /
    • v.7 no.2
    • /
    • pp.51-70
    • /
    • 2000
  • Twenty normal and 20 severe-to-profound hearing-impaired subjects participated in the present study. The two groups are matched by their chronological age. Each subject made a recording of three vowels of /i/, /a/, and /u/, and nine $VC_{plosive}V$ (hereafter, VCV) disyllables of /epe/, /ep'e/, /$ep^{h}e$/, /ete/, /et'e/, /$et^{h}e$/, /eke/, /ek'e/, and /$ek^{h}e$/, each five times. Formant frequencies of $F_1,\;F_2,\;and\;F_3$ were measured for the three vowels and six measures were made for the nine disyllables. The six measures were (1) the total duration of the disyllable, (2) the duration of the first vowel, (3) the duration of the closed period, (4) the ratio of the first vowel over the first vowel plus the closure period of the consonant, (5) the duration of the aspiration, and (6) the duration of the second vowel. Results shows that the three formants and each of the measures were significantly different between the two groups of subjects.

  • PDF