• Title/Summary/Keyword: EPA method

Search Result 250, Processing Time 0.022 seconds

A Study on the Comparison of Measuring Methods and Development of Emssion Factor on Mercury from Large-Scale Emission Sources (대형배출원에서의 수은 측정방법 비교 및 배출계수 개발에 관한 연구)

  • Kim, Hyung-Chun;Kim, Rhok-Ho;Kim, Jong-Hyeon;Lim, Seung-young;Kang, Dae-Il;Hong, Ji-Hyung;Jang, Kee-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.2
    • /
    • pp.184-192
    • /
    • 2016
  • Recently, studies on reducing mercury have been actively conducted worldwide, which include the current status of mercury emissions and mercury control technology. Among the control technology, Sorbent Trap measurement method has been aggressively developed due to its reliability, easiness in measurement and analysis. The purpose of this study is to evaluate the applicability of the new international measurement method; Sorbent Trap. For this, the study compared the Sorbent trap method (US EPA Method 30B) and the Korean Standard Method for Examination of Air (ES 01408.1) to evaluate their reliability, and developed mercury emission factors. As the result, the relative standard deviations (% RSD) of the two methods were 3.5~13.4% at Coal-fired Power Plants (CPP), 4.0~18.4% at Cement Kilns (CK), and 3.0~11.3% at Medical Waste Incinerators (MWI). The emissions factors were developed as 14.50 kg/ton at CPP, 45.10 kg/ton at CK, and 1,290.2 kg/ton at MWI.

Analysis of Volatile Organic Compounds in Water by Modified Injection Mode for Purge & Trap-GC/MS Method (Purge & Trap-GC/MS 분석법의 주입방식 개선에 의한 물 중의 휘발성 유기물 분석)

  • Jeon, Chi Wan;Lee, Sang Hak;Eum, Chul Hun
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.8
    • /
    • pp.635-642
    • /
    • 1995
  • Improved sample introduction system has been investigated for the determination of volatile organic compounds in water using a purge & trap preconcentration apparatus and a capillary gas chromatography/mass spectrometry. The present limitations associated with the moisture control module and cryorefocusing system suggested by EPA were discussed. To solve the problems such as improper separation of peaks due to the adsorption of water and contamination of purge & trap system, a more efficient connection system between the purge & trap apparatus and the gas chromatograph was introduced and the optimum operational conditions were suggested. A carbopack B/carboxen 1000 and 1001 trap was used for the purge & trap procedure and a custom made crosslinked dimethyldiphenylpolysiloxane capillary column was used for the separation of compounds. Accuracy and precision of the method suggested in this report were examined and the method detection limit of each compound was proposed for the simultaneous determination of 54 volatile organic compounds in water.

  • PDF

Hazardous Characteristics of metals in Bottom Ash from Municipal Solid Waste Combustors(MSWC) of Korea (도시폐기물 소각로에서 발생되는 바닥재중의 금속류 유해특성에 관한 연구)

  • Chung, David;Kim, Yu-Nung;Yun, Young-Ja;Kim, Yoen-Ho
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.253-258
    • /
    • 2001
  • This is a research on hazardous characteristics and potentials of bottom ash from 9 municipal solid waste combustors(200 tons/day) of Korea by the test methods of leaching and content. The leaching method was performed by Waste Test Method of Korea. In case of the content method, mercury was determined by thermal decomposition amalgamation atomic absorption spectrometer, other 9 elemets including Pb, which were pretreated by U.S.EPA SW-846 3050B method, were determined by flame atomic absorption spectrometer(FAAS) or inductively coupled plasma atomic emission spectrometer(ICP-AES). Results of leaching test showed that Pb and Cu was main pollutants. It was interested that the distribution rate of metals' contents of each combustors was similar and the rank of concentration was Fe>Zn>Cu>Mn>Pb>Cr>As>Cd>Hg.

  • PDF

Quality Properties of Conger Eel (Conger myriaster) Oils Extracted by Supercritical Carbon Dioxide and Conventional Methods (초임계 이산화탄소 및 유기용매를 이용하여 추출된 붕장어(Conger myriaster) 오일의 품질특성)

  • Park, Jin-Seok;Cho, Yeon-Jin;Jeong, Yu-Rin;Chun, Byung-Soo
    • Clean Technology
    • /
    • v.25 no.4
    • /
    • pp.275-282
    • /
    • 2019
  • In this study, the extraction of Conger myriaster oil by using supercritical carbon dioxide (SC-CO2) and organic solvent was investigated. The extraction conditions conducted for SC-CO2 varied for pressure (25, 30 MPa) and temperature (45, 55 ℃), while the SC-CO2 flow rate was kept constant during the experiment (27 g min-1) and hexane was used as a conventional organic solvent. The extraction yield indicated that the best extraction condition would be SC-CO2 at 55 ℃ and 30 MPa, resulting in the highest yield of 37.73 ± 0.14%. The oils were characterized for their fatty acid (FAs) composition using gas chromatography, while it was revealed that the major FAs were mystric acid, palmitoleic acid, oleic acid, electroosapentaenoic acid (EPA), and docosahexaenoic acid (DHA). The oxidation stability of the extracted C. myriaster oil was evaluated by measuring the acid value, peroxide value, and free fatty acid. The best oxidative stability was obtained from SC-CO2 extracted oil at 30 MPa and 55 ℃. There was a significant difference in the color properties of the SC-CO2 and hexane extracted oils, with the SC-CO2 extracted oil showing better chromaticity than the oil extracted using hexane. Extracting oils from C. myriaster with SC-CO2 could bring better economic benefits than using organic solvents. When supercritical carbon dioxide was used, there was no post-treatment process; thus, it was confirmed that this is a more environmentally friendly oil extraction method.

An Estimation of NPS Pollutant Loads using the Correlation between Storm Water Runoff and Pollutant Discharge in a Small Urban Drainage Basin (도시소유역에서의 유출과 비점원오염물 배출 간의 상관관계 수립에 의한 NPS 오염물 배출량의 산정)

  • 신현석;윤용남
    • Water for future
    • /
    • v.26 no.4
    • /
    • pp.85-95
    • /
    • 1993
  • Three purposes of this study are as follows: The first was the development of the extention method for the limited data observed in an urban drainage basin. The second was the analysis of the correlation between storm water runoff and NPS(non-point source) pollutant discharge, The last was the calculation of the monthly and annual specific NPS loads using the established correlation. the selected model was the SWMM monthly and annual specific NPs loads using the established correlation. The selected model was the SWMM (Storm Water Management model) developed by the US EPA(environmental Protection Agency). As a result of this study, the best correlation between storm wate runoff and NPS pollutants discharge was produced by the non-linear correlation between runoff rate(mm/hr)and specific loads rate(g/ha/sec)for all pollutants studied ; SS, COD, BOD, and TN. The best correlation through the analysis based on evently total mass was made by the linear correlation between the specific accumulated runoff(mm) and the specific accumulated loads(kg/ha) for CASE 1., and by the non-linear correlation for CASE 2. The NPS annual specific loads for the urban basin studied were 4933 kg/ha/year for SS, 775kg/ha/year for BOD, 3094kg/ha /year for COD,257kg/ha/year for TN, respectively. And the proportion of the NPS annual specific loads to the total annual specific loads were 42 % for SS, 13 % for BOD, 29% for COD, and 21 % for TN.

  • PDF

Comparison of the elution patterns for polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/Fs) and dioxin-like polychlorinated biphenyls (PCBs) by manual open columns and automatic parallel LC columns (수동 및 자동화 액체 크로마토그래피 칼럼에 의한 PCDDs/Fs 및 다이옥신과 유사한 PCBs의 용출 패턴 비교)

  • Ahn, Yun Gyong;Shin, Jeoung Hwa;Yoo, Sun Young;Khim, Jeehyeong;Hong, Jongki
    • Analytical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.13-22
    • /
    • 2005
  • The elution patterns of seventeen 2,3,7,8-substituted PCDDs/Fs and 12 dioxin-like PCBs were studied by both manual open columns and automatic parallel LC columns in cleanup procedure. PCDDs/Fs and non-ortho-PCBs from other mono-ortho-PCBs were separated on automatic LC column, whereas they were not separated on an open manual column. The elution study on two cleanup methods was carried out using the PAR solution of unlabeled congeners and checked the recovery of each congener. Total recoveries of cleanup fractionation were ranged between 61.9 ~ 96.0% for PCDDs/Fs and 70.4 ~ 79.0% for PCBs by manual open columns and 71.8 ~ 104.5% for PCDDs/Fs and 61.3-120.3% for PCBs by automatic parallel LC columns, respectively. Unfortunately, #169-HxCB and 1,2,3,7,8-PeCDD were not separated on DB-5MS capillary column. The ions of 1,2,3,7,8-PeCDD were selected at M/M+2 instead of M+2/M+4 suggested by EPA method 1613. It is possible to discriminate 1,2,3,7,8-PeCDD and PCB #169 in HRGC/HRMS analysis.

A study on development of CRM chrysotile in soil (토양 중 백석면 표준물질 개발에 관한 연구)

  • Choi, Yun-Ho;Kwon, Ye-Bin;Lee, Jin-Wook;Kim, Nam-Jun;Jeong, Min-Jong;Hwang, Beom-Goo;Lee, Jae-Hyung;Sun, Yle-Shik;Kim, Bak-Gil
    • Analytical Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.91-98
    • /
    • 2013
  • Interested in NOA (Naturally Occurring Asbestos), Korea as well as the USA has been making geologic maps of asbestos distributed mines and surrounding areas, restoring mines, evaluating hazard, and so on. The result can be used to improve the reliability of analysts and analysis institutions by judging the amount of asbestos and set up PLM(Polarizing Light Microscope) information by analyzing in soil. The certification value of 2 kinds of CRM(Certified Reference Material) was performed by counting total 400 points with EPA 600-R-93-116 method using by PLM. The following is the result of homogeneity and stability of 2 kinds of manufactured CRM analyzed by ANOVA (Analysis of variance) and Regression Analysis. Based on the analyzation, the results are satisfied with homogeneity and long-term stability. The analyzed certification value of CRM includes the range of minimum and maximum value of point counting result for chrysotile; low concentration-1% (range, 0.25~3.00), high concentration-4% (range, 2.25~5.50).

Study on analytical method and international quality control program for environmental lead (환경 중 납 분석에 관한 국제 정도관리 및 분석 방법 연구)

  • Choi, Inja;Yoon, Chungsik;Kang, Taesun;Yang, Wonsu;Park, Dong Uk;Park, Doo Yong
    • Analytical Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.381-387
    • /
    • 2002
  • In this study, we introduced experience participated in ELPAT (Environmental Lead for Proficiency Analytical Testing) program that is administered by the American Industrial Hygiene Association and EPA. The 126 sample results of total 128 samples met reference value, as a result accepted 'proficient'. The concentration of Pb in air, paint chips, soils and dust wipes are $0.0089{\sim}0.3956mg/m^3$, 0.0500~8.9149%, 29.0${\sim}$1697 mg/kg and $18.00{\sim}900.3{\mu}g/sample$, respectively. The lead in environmental matrix prepared adequate techniques and analysed by flame atomic absorption spectrometry. The lead in air was extracted hydrochloric acid, in paint chips and soils were digested with microwave and hotplate and in dust wipes were prepared microwave digestion. No differences of each preparation techniques was found and all methods were to be proper.

A Study on the Risk of Pesticide Exposure by Food Intake (식이섭취를 통한 농약폭로의 위해도에 관한 연구)

  • 전옥경;이용욱
    • Journal of Food Hygiene and Safety
    • /
    • v.14 no.2
    • /
    • pp.201-215
    • /
    • 1999
  • Limited information is available on the acceptability of Korean MRLs(maximum residue limits) and the health risk based on the pesticide exposure by food intake. The aim of this study was to evaluate TMDI(theoretical maximum daily intake) and EDI(estimated daily intake) for Korean by using MRLs, food intake, residue data, and correction factors, and compare with ADI(acceptable daily intake) in order to estimate the health risk based on the pesticide exposure. The study was performed in three steps. In the frist step, the residual pesticides in each category of food were investigated using the pesticide residue analytical data(1995-96) from officially approved organizations and the analytical data for poultry was adopted from Korean food code method. In the second step, TMDI was estimated from MRLs and food factors, and was compared with ADI. In the third step, the effectiveness of each culinary treatment (washing, peeling, steaming, boiling, and salting) was evaluated and EDI was calculated using pesticide residue data, food factor, and correction factor by treatment. TMDI obtained from MRLs and food intake, and food intake was summed as 1,100.99 g, which was 79.1% of total consumption. The percent ratio of TMDI to ADI for 156 pesticides was mostly below 80% and only 30 pesticides exceeded the ADI. In particular, non-treated EDI from pesticide residue data and food intake was summed up to about 43 $\mu\textrm{g}$/day/capita, and the rank was procymidone(8.6 $\mu\textrm{g}$) > maleic hydrazide(8.2 $\mu\textrm{g}$) > EPN(3.7 $\mu\textrm{g}$) > deltamethrin(3.5 $\mu\textrm{g}$) > cypermethrin(3.0 $\mu\textrm{g}$). The treated EDI calculated from pesticide residue data, food intake, and correction factor by culinary treatment was summed up to 13.7 $\mu\textrm{g}$/day/captia. The percentage of ADI was TMDI(79.74%) > non-treated EDI (0.17%) > treated EDI (0.04%), and the exposure level of Korean population to whole pesticides was below the level to produce health risk. Oncogenic risk of five pesticides used in Korea whose oncogenic potency(Q*) was known were assessed from TMDI and treated EDI. Dietary oncogenic risk for Korean was estimated to be 2.0$\times$10-3 on the basis of TMDI, 8.3$\times$10-7 on the basis of treated EDI. The oncogenic risk from TMDI exceeded the risk level(1$\times$10-6) of EPA, whereas the oncogenic risk from treated EDI and real exposure level lower than that of EPA.

  • PDF

The chemical reactivity of detecting tube detection equipment for incident responder (화학사고 초기대응자를 위한 검지관식 탐지장비의 반응성 연구)

  • Ahn, Seung-Young;Kim, Jungmin;Kim, Sungbum;Chun, Kwangsoo;Lee, Jin-Seon;Park, Choonhwa
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.1
    • /
    • pp.33-39
    • /
    • 2014
  • Chemical accidents are the cause of the accident site during the initial responders to quickly and easily see materials and concentration method for the U.S. Environmental Protection Agency(EPA) is widely used in the initial response team direct reading detection equipment used. Ministry of the tubular gas detection equipment to detect direct reading detection equipment used in the event of an accident scene, and shell-and-tube gas detector for rapid detection and identification and precise analysis of causative pollutants before about strategically can identify the quantitative and qualitative useful equipment. However, those who initially respond to the scene of a direct reading detection equipment and a simple lack of understanding of how to use the numbers only because of the way you want to check the accuracy of detection results have been raising questions about the increase. The scene of the accident in order to obtain an accurate detection results used in this paper, the Ministry of Environment of gas detectors detect tubular Kitagawa and Draeger detector tube to check the reactivity of the material on-site detection of early response of those who were to raise the accuracy of the results.