• Title/Summary/Keyword: EOC

Search Result 197, Processing Time 0.034 seconds

Application of Change Detection Techniques Using KOMPSAT-1 EOC Images

  • Kim, Youn-Soo;Lee, Kwang-Jae
    • Korean Journal of Remote Sensing
    • /
    • v.19 no.3
    • /
    • pp.263-269
    • /
    • 2003
  • This research examined the capabilities of KOMPSAT-1 EOC images for the application of urban environment, including the urban changes of the study areas. This research is constructed in three stages: Firstly, for the application of change detection techniques, which utilizes multi-temporal remotely sensed data, the data normalization process is carried out. Secondly, the change detection method is applied for the systematic monitoring of land-use changes. Lastly, using the results of the previous stages, the land-use map is updated. Consequently, the patterns of land-use changes are monitored by the proposed scheme. In this research, using the multi-temporal KOMPSAT-1 EOC images and land-use maps, monitoring of urban growth was carried out with the application of land-use changes, and the potential and scope of the application of the EOC images were also examined.

Overexpression of Semaphorin4D Indicates Poor Prognosis and Prompts Monocyte Differentiation toward M2 Macrophages in Epithelial Ovarian Cancer

  • Chen, Ying;Zhang, Lei;Lv, Rui;Zhang, Wen-Qi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.10
    • /
    • pp.5883-5890
    • /
    • 2013
  • Previously, we demonstrated overexpression of semaphorin4D (SEMA4D, CD100) to be closely related to tumor angiogenesis in epithelial ovarian cancers (EOCs). However, the function and expression of SEMA4D in the EOC microenvironment has yet to be clarified in detail. In this study, we confirmed that overexpression of SEMA4D in primary tumors and ascites was related to low differentiation, platinum resistance and a refractory status (P<0.05), while high M2 macrophage count and percentage were evident in EOC patients with advanced FIGO stage and platinum resistance (P<0.05), using immunohistochemistry, enzyme-linked immunosorbent assay (ELISA), and fluorescence-activated cell sorting (FACS), respectively. The data showed correlations of SEMA4D expression and M2 macrophage counts in primary tumors and M2 macrophage percentage in ascites (r=0.281 and 0.355, each P<0.05). In the Cox proportional hazard mode, SEMA4D expression was an independent indicator of overall survival (OS) and progression-free survival (PFS) for EOC patients. Furthermore, higher expression of SEMA4D in ovarian cancer cell lines (SKOV3, A2780, and SW626) and their supernatants were found than that in a human primary cultured ovarian cell and its supernatant by reversed transcript PCR (RT-PCR), Western blotting and ELISA, respectively. Interestingly, peripheral blood monocytes (MOs) tended towards the M2-polarized macrophage phenotype ($CD163^{high}$) in vitro after human recombined soluble SEMA4D protein stimulation. These findings suggest that SEMA4D might possibly serve as a reliable tool for early and accurate prediction of EOC poor prognosis and could playan important role in promoting tumor dissemination and metastasis in the EOC microenvironment. Thus SEMA4D and its role in macrophage polarization in EOC warrants further study.

Impact of Preoperative Serum Levels of CA 125 on Epithelial Ovarian Cancer Survival

  • Pradjatmo, Heru
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.4
    • /
    • pp.1881-1886
    • /
    • 2016
  • Background: CA125 is very helpful in treatment monitoring and detection of epithelial ovarian cancer (EOC) recurrence. However there is controversy as to its accuracy and optimal usage. What is the impact of the CA125 levels before primary surgery treatment to the survival of patients? This study aimed to detect any association of preoperative serum levels with prognosis and survival in EOC patients. Materials and Methods: Our cohort comprised EOC patients in Dr. Sardjito Hospital, Yogyakarta, Indonesia, who complied with follow up. To explore the effect of preoperative CA125 levels and other variables on survival Cox's regression models were applied. Results: A total of 90 cases of EOC who had surgery were available for follow up. The level of CA125 proved to be a prognostic factor for overall survival of EOC patients, with an adjusted HR of 4.10 (p = 0.03). Adjuvant chemotherapy was another prognostic factor, 1 - 2 cycles having an adjusted HR of 0.17 (p = 0.04) and 3 - 8 cycles HR 0.39 (p = 0.06). Other factors such as age of patients adjusted HR 1.54 (p = 0.32), moderate differentiation (adjusted HR 1.61, p = 0.51) poor differentiation (adjusted HR 3.41, p = 0.15), and stage of disease (adjusted HR 1.98,p=0.27) were statistically not significant. However, this might have been because the power of the study was low. Conclusions: Preoperative level of CA125 is a prognostic factor for overall survival in EOC patients. The best cut-off for prognostic classification of CA125 serum level is 70 U/ml.

Detecting Land Cover Change in an Urban Area by Image Differencing and Image Ratioing Techniques (영상의 차연산과 비연산 기법에 의한 도시지역의 토지피복 변화탐지)

  • Lee, Jin-Duk;Jo, Chang-Hwan
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.12 no.2 s.29
    • /
    • pp.43-52
    • /
    • 2004
  • This study presents the application of aerial photographs and the Korea Multi-Purpose Satellite, KOMPSAT-1 Electro-Optical Camera(EOC) imagery in detecting change in an urban area that has been rapidly growing. For the study, we used multi-temporal images which were acquired by two different sensors. Image registration and resampling were rallied out before performing change detection in a common reference system with the same spatial resolution. for all of the images. Results from image differencing and image ratioing techniques show that panchromatic aerial photographs and KOMPSAT-1 EOC images collected by different sensors have potential to detect changes of urban features such as building, road and other man-made structure. And the optimal threshold values were suggested in applying image differencing and image ratioing techniques for change detection.

  • PDF

Change Detection Using Multispectral Satellite Imagery and Panchromatic Satellite Imagery (다중분광 위성영상과 팬크로매틱 위성영상에 의한 변화 검출)

  • Lee, jin-duk;Han, seung-hee;Cho, hyun-go
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2008.05a
    • /
    • pp.897-901
    • /
    • 2008
  • The objective of this study is to conduct land cover classification respectively using Landsat TM data collected on Oct., 1985 and KOMPSAT-1 EOC data collected on Jan., 2000 covering Gumi city, Gyeongbuk Province and to detect urban change by comparing between both land cover maps. Multispectral images of Landsat TM have spatial resolution of 30m are well known as useful data for extracting information related to landcover, vegetation classification, urban growth analysis and so forth. In contrast, as KOMPSAT-1 EOC collects panchromatic images with relatively high spatial resolution of 6.6m. We try to analyze how accurate landcover classification result is able to be derived from the panchromatic images. As the results of the study, the KOMPSAT EOC data with high resolution greater than 4 times showed higher classification degree than Landsat TM data. It was ascertained that the built-up region was extended by three to four times in the last 15 years between 1985 and 2000. In the contrast, it was shown that the forest region was decreased by 15% to 27% and the grass region including agricultural region was decreased by 28% to 45%.

  • PDF

KOMPSAT Data Processing System: An Overview and Preliminary Acceptance Test Results

  • Kim, Yong-Seung;Kim, Youn-Soo;Lim, Hyo-Suk;Lee, Dong-Han;Kang, Chi-Ho
    • Korean Journal of Remote Sensing
    • /
    • v.15 no.4
    • /
    • pp.357-365
    • /
    • 1999
  • The optical sensors of Electro-Optical Camera (EOC) and Ocean Scanning Multi-spectral Imager (OSMI) aboard the KOrea Multi-Purpose SATellite (KOMPSAT) will be placed in a sun synchronous orbit in late 1999. The EOC and OSMI sensors are expected to produce the land mapping imagery of Korean territory and the ocean color imagery of world oceans, respectively. Utilization of the EOC and OSMI data would encompass the various fields of science and technology such as land mapping, land use and development, flood monitoring, biological oceanography, fishery, and environmental monitoring. Readiness of data support for user community is thus essential to the success of the KOMPSAT program. As a part of testing such readiness prior to the KOMPSAT launch, we have performed the preliminary acceptance test for the KOMPSAT data processing system using the simulated EOC and OSMI data sets. The purpose of this paper is to demonstrate the readiness of the KOMPSAT data processing system, and to help data users understand how the KOMPSAT EOC and OSMI data are processed, archived, and provided. Test results demonstrate that all requirements described in the data processing specification have been met, and that the image integrity is maintained for all products. It is however noted that since the product accuracy is limited by the simulated sensor data, any quantitative assessment of image products can not be made until actual KOMPSAT images will be acquired.

Prediction Method of End of Charge Voltage using Battery Parameter Measurement (배터리 파라미터 측정을 이용한 충전종지전압 예측기법)

  • Kim, Ho-Yong;Wang, Yi-Pei;Park, Seong-Mi;Park, Sung-Jun;Son, Gyung-Jong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.387-396
    • /
    • 2022
  • Recently, e-Mobility, which is a personal mobility device such as an electric bicycle or an electric scooter, is rapidly emerging. However, since E-Mobility has various voltage systems due to the characteristics of its products, it is essential for companies that operate them to use multiple dedicated chargers. A universal charger capable of charging batteries of various voltage systems with one charger is required to reduce the cost of purchasing and managing multiple dedicated chargers. For this, information on the EOC(End of Charge) is essential. In order to know the EOC, it is necessary to detect the internal impedance of the battery. However, the internal impedance of the battery changes according to various conditions such as SOH(State Of Health), SOC(State Of Charge), and ambient temperature. By observing the change in these parameters, the state of the battery can be diagnosed and the EOC can be predicted. In this paper, we propose an algorithm to analyze the battery's internal impedance and to predict the EOC, in order to acquire information on the EOC of the battery, which is an essential requirement of a universal charger.

Emotion-on-a-chip(EOC) : Evolution of biochip technology to measure human emotion (감성 진단칩(Emotion-on-a-chip, EOC) : 인간 감성측정을 위한 바이오칩기술의 진화)

  • Jung, Hyo-Il;Kihl, Tae-Suk;Hwang, Yoo-Sun
    • Science of Emotion and Sensibility
    • /
    • v.14 no.1
    • /
    • pp.157-164
    • /
    • 2011
  • Emotion science is one of the rapidly expanding engineering/scientific disciplines which has a major impact on human society. Such growing interests in emotion science and engineering owe the recent trend that various academic fields are being merged. In this paper we propose the potential importance of the biochip technology in which the human emotion can be precisely measured in real time using body fluids such as blood, saliva and sweat. We firstly and newly name such a biochip an Emotion-On-a-Chip (EOC). EOC consists of biological markers to measure the emotion, electrode to acquire the signal, transducer to transfer the signal and display to show the result. In particular, microfabrication techniques made it possible to construct nano/micron scale sensing parts/chips to accommodate the biological molecules to capture the emotional bio-markers and gave us a new opportunities to investigate the emotion precisely. Future developments in the EOC techniques will be able to help combine the social sciences and natural sciences, and consequently expand the scope of studies.

  • PDF

Characteristics of the Electro-Optical Camera(EOC) (다목적실용위성탑재 전자광학카메라(EOC)의 성능 특성)

  • Seunghoon Lee;Hyung-Sik Shim;Hong-Yul Paik
    • Korean Journal of Remote Sensing
    • /
    • v.14 no.3
    • /
    • pp.213-222
    • /
    • 1998
  • Electro-Optical Camera(EOC) is the main payload of the KOrea Multi-Purpose SATellite(KOMPSAT) with the mission of cartography to build up a digital map of Korean territory including a Digital Terrain Elevation Map(DTEM). This instalment which comprises EOC Sensor Assembly and EOC Electronics Assembly produces the panchromatic images of 6.6 m GSD with a swath wider than 17 km by push-broom scanning and spacecraft body pointing in a visible range of wavelength, 510~730 nm. The high resolution panchromatic image is to be collected for 2 minutes during 98 minutes of orbit cycle covering about 800 km along ground track, over the mission lifetime of 3 years with the functions of programmable gain/offset and on-board image data storage. The image of 8 bit digitization, which is collected by a full reflective type F8.3 triplet without obscuration, is to be transmitted to Ground Station at a rate less than 25 Mbps. EOC was elaborated to have the performance which meets or surpasses its requirements of design phase. The spectral response, the modulation transfer function, and the uniformity of all the 2592 pixel of CCD of EOC are illustrated as they were measured for the convenience of end-user. The spectral response was measured with respect to each gain setup of EOC and this is expected to give the capability of generating more accurate panchromatic image to the users of EOC data. The modulation transfer function of EOC was measured as greater than 16 % at Nyquist frequency over the entire field of view, which exceeds its requirement of larger than 10 %. The uniformity that shows the relative response of each pixel of CCD was measured at every pixel of the Focal Plane Array of EOC and is illustrated for the data processing.