• 제목/요약/키워드: ENERGY PLUS

검색결과 463건 처리시간 0.034초

체외배양액과 첨가물질이 소 체외수정란의 체외발육에 미치는 효과 (Effect of Culture Medium and Additive on the Development of Bovine IVM/IVF Embryos)

  • 박동헌;황환섭;정희태;박춘근;김정익;김종복;양부근
    • 한국가축번식학회지
    • /
    • 제20권2호
    • /
    • pp.191-196
    • /
    • 1996
  • The objective of this study were to investigate the effects of culture media and additives on the development of bovine in vitro matured(IVM) and in vitro fertilized(IVF) oocytes. In experiment 1, bovine oocytes were cultured in droplets of TC 199 supplemented with 10% fetal bovine serum(FBS) with or without hormones (5$\mu\textrm{g}$/ml FSH, 5$\mu\textrm{g}$/ml LH, 1$\mu\textrm{g}$/ml E2). Cleavage rates of embryos cultured for 40~44hrs after IVF were higher when embryos were cultured in TC 199 supplemented hormones (68.1%, 921/35) than without hormones (52.7%, 77/146), but the percentages of development beyond morulae stage were not difference (20.7%, 19.4%). In experiment 2, the effects of various media such as TC 199, synthetic oviduct fluid(SOF), CR1aa with different energy source (fatal bovine serum, FBS; bovine serum albumin, BSA) on developmental capacity of IVM/IVF bovine embryos were investigated. The developmental rates into morulae and blastocysts were 27.1, 10.7, 6.3 and 0%, respecitvely, in CR1aa plus 3mg/ml BSA, SOF plus 10% FBS, TC 199 plus 10% FBS, SOF plus 3mg/ml BSA. In experiment 3, the comparisons of bovine embryos developed to morulae and blastocysts in different culture media (TC 199, SOF, CR1aa, Menezo's B2) were investigated. The developmental capacity beyond morulae stage were 32.9, 26.6, 11.1 and 7.1%, respectively, in Menezo's B2 plus BSA, CR1aa plus BSA, SOF plus BSA, TC 199 plus FBS medium. The cell numbers of the blastocyst were not different in different cultrue media. In experiment 4, bovine embryos were co-cultured with vobine oviduct epithelial cells(BOEC) in TC 199 plus FBS, SOF plus BSA, CR1aa plus BSA, Menezo's B2 plus BSA. The morula and blastocyst rates were 44.7, 32.9, 26.0 and 23.3%, respectively, in CR1aa TC 199, SOF, and Menezo's B2 medium. The cell numbers of the blastocyst were similar to those of blastocyst developed in different culture media.

  • PDF

초기 설계단계 건물 에너지 성능평가를 위한 IFC 속성정보 호환성 향상에 관한 연구 (A Study on the Interoperability Improvement of IFC Property Information for Energy Performance Assessment in the Early Design Phase)

  • 김인한;유현재;최중식
    • 한국CDE학회논문집
    • /
    • 제17권6호
    • /
    • pp.456-465
    • /
    • 2012
  • Nowadays, AEC industry tries to adopt BIM for low-carbon and eco-friendly building development. With increasing environment policies, many of global construction projects require the adoption of BIM for its many advantages. The advantages can be maximized with Open BIM since it can produce optimal results for various purposes of energy performance assessment. However there are some troubles in representation and property information in the process of Open BIM based energy performance assessment. To examine such troubles, this study focuses on differences between IFC of Open BIM and IDF format of Energy Plus known as the most accurate and diverse energy performance assessment. Two issues the study addresses are form representation and property information. The study figures out the different definition of IFC and IDF, and suggests the way of interoperability. The interoperability test of IFC for building energy performance assessment hope to develop of Open BIM based energy assessment.

AHU 토출온도에 따른 일반 공조시스템의 에너지 소비량 및 실내 온열환경 분석 (Energy Consumption and Thermal Comfort Assessment of Conventional Forced-air System According to AHU Discharge Air Temperature)

  • 김민지;연상훈;이광호
    • 설비공학논문집
    • /
    • 제30권2호
    • /
    • pp.51-57
    • /
    • 2018
  • Recently, global warming has been a serious issue on the worldwide, and the importance of energy conservation is increasing. In most buildings, energy consumption increases due to cooling, heating, and ventilation. Because of these issues, researches have been carried out to reduce building energy. However, in most conventional forced-air system, the guidelines for the Air Handling Unit (AHU) discharge air temperature are not fully established. The purpose of this study is to assess the impact of AHU discharge air temperature, which is one of the important control variables, on the overall energy consumption and thermal comfort characteristics by modeling conventional forced-air system using EnergyPlus. In addition, recommendations for energy reduction in conventional AHU is provided.

IFC 데이터의 건물에너지 성능평가를 위한 공간경계정보 호환성 향상 연구 (A Study on the Space Boundary Information Interoperability Improvement of IFC Data for Building Energy Performance Assessment)

  • 최중식;김인한
    • 한국CDE학회논문집
    • /
    • 제19권2호
    • /
    • pp.129-137
    • /
    • 2014
  • Due to the increase of carbon dioxide and building regulations, BIM is considered a way of low-carbon and eco-friendly building development for its many advantages. The advantages can be maximized with Open BIM since it can produce optimal results for various purposes of energy performance assessment. However there are some problems in data interoperability in the process of Open-BIM based energy performance assessment. To solve such problems, this study focuses on space boundary information interoperability between IFC of Open BIM and IDF format of Energy Plus known as the most accurate and diverse energy performance assessment. The study analyzes the analogous study then figures out the problems of IFC based energy performance analysis, and suggests the way of interoperability. Finally, the development of automation program makes this way much more effective. The study of IFC data interoperability is useful for improving the reliability of Open-BIM based energy assessment.

아스펜 플러스를 이용한 폭발성 가스 건식 연소 처리공정의 열회수 모델링 및 엑서지 분석 (Heat Recovery Modeling and Exergy Analysis of Dry Combustion Process for Explosive Gas Treatment Using Aspen Plus)

  • 최용만;최창식;홍범의;조성수;김용진;김학준
    • 한국대기환경학회지
    • /
    • 제33권5호
    • /
    • pp.521-528
    • /
    • 2017
  • In the combustion treatment of explosive gases with a high heating value such as $H_2$ and $NH_3$ used in semiconductor and chemical processes, the heat recovery modeling and exergy analysis of the process using the Aspen Plus simulator and its thermodynamic data were performed to examine the recovery of high temperature thermal energy. The heat recovery process was analyzed through this process modeling while the exergy results clearly confirmed that the rigorous reaction mainly occurs in the condenser and the chamber. In addition, the process modeling demonstrated that approximately 95% of the exergy is destructed on the basis of the exergies injected and the exergy being exhausted. Using the exergy technique, which can quantitatively analyze the energy, we could understand the energy flow in the process and confirm that our heat recovery process was efficiently designed.

기상 예보 데이터와 일사 예측 모델식을 활용한 실시간 에너지 수요예측 (Real-time Energy Demand Prediction Method Using Weather Forecasting Data and Solar Model)

  • 곽영훈;천세환;장철용;허정호
    • 설비공학논문집
    • /
    • 제25권6호
    • /
    • pp.310-316
    • /
    • 2013
  • This study was designed to investigate a method for short-term, real-time energy demand prediction, to cope with changing loads for the effective operation and management of buildings. Through a case study, a novel methodology for real-time energy demand prediction with the use of weather forecasting data was suggested. To perform the input and output operations of weather data, and to calculate solar radiation and EnergyPlus, the BCVTB (Building Control Virtual Test Bed) was designed. Through the BCVTB, energy demand prediction for the next 24 hours was carried out, based on 4 real-time weather data and 2 solar radiation calculations. The weather parameters used in a model equation to calculate solar radiation were sourced from the weather data of the KMA (Korea Meteorological Administration). Depending on the local weather forecast data, the results showed their corresponding predicted values. Thus, this methodology was successfully applicable to anywhere that local weather forecast data is available.

ANALYSIS OF THE LiF:Mg,Cu,Si TL AND THE LiF:Mg,Cu,P TL GLOW CURVES BY USING GENERAL APPROXIMATION PLUS MODEL

  • Chang, In-Su;Lee, Jung-Il;Kim, Jang-Lyul;Oh, Mi-Ae;Chung, Ki-Soo
    • Journal of Radiation Protection and Research
    • /
    • 제34권4호
    • /
    • pp.155-164
    • /
    • 2009
  • In this paper, we used computerized glow curve deconvolution (CGCD) software with several models for the simulation of a TL glow curve which was used for analysis. By using the general approximation plus model, parameters values of the glow curve were analyzed and compared with the other models parameters (general approximation, mixed order kinetics, general order kinetics). The LiF:Mg,Cu,Si and the LiF:Mg,Cu,P material were used for the glow curve analysis. And we based on figure of merits (FOM) which was the goodness of the fitting that was monitored through the value between analysis model and TLD materials. The ideal value of FOM is 0 which represents a perfect fit. The main glow peak makes the most effect of radiation dose assessment of TLD materials. The main peak of the LiF:Mg,Cu,Si materials has a intensity rate 80.76% of the whole TL glow intensity, and that of LiF:Mg,Cu,P materials has a intensity rate 68.07% of the whole TL glow intensity. The activation energy of LiF:Mg,Cu,Si was analyzed as 2.39 eV by result of the general approximation plus(GAP) model. In the case of mixed order kinetics (MOK), the activation energy was analyzed as 2.29 eV. The activation energy was analyzed as 2.38 eV by the general order kinetics (GOK) model. In the case of LiF:Mg,Cu,P TLD, the activation energy was analyzed as 2.39 eV by result of the GAP model. In the case of MOK, the activation energy was analyzed as 2.55 eV. The activation energy was analyzed as 2.51 eV by the GOK model. The R value means different ratio of retrapping-recombination. The R value of LiF:Mg,Cu,Si TLD main peak analyzed as $1.12\times10^{-6}$ and $\alpha$ value analyzed as $1.0\times10^{-3}$. The R of LiF:Mg,Cu,P TLD analyzed as $7.91\times10^{-4}$, the $\alpha$ value means different ratio of initial thermally trapped electron density-initial trapped electron density (include thermally disconnected trap electrons density). The $\alpha$ value was analyzed as $9.17\times10^{-1}$ which was the difference from LiF:Mg,Cu,Si TLD. The deep trap electron density of LiF:Mg,Cu,Si was higher than the deep trap electron density of LiF:Mg,Cu,P.

신재생에너지 단독주택 모델 냉방운전의 선형계획법 기반 운전 최적화 연구 (Optimal Cooling Operation of a Single Family House Model Equipped with Renewable Energy Facility by Linear Programming)

  • 신영기;김의종;이경호
    • 설비공학논문집
    • /
    • 제29권12호
    • /
    • pp.638-644
    • /
    • 2017
  • Optimal cooling operation algorithm was developed based on a simulation case of a single family house model equipped with renewable energy facility. EnergyPlus simulation results were used as virtual test data. The model contained three energy storage elements: thermal heat capacity of the living room, chilled water storage tank, and battery. Their charging and discharging schedules were optimized so that daily electricity bill became minimal. As an optimization tool, linear programming was considered because it was possible to obtain results in real time. For its adoption, EnergyPlus-based house model had to be linearly approximated. Results of this study revealed that dynamic cooling load of the living room could be approximated by a linear RC model. Scheduling based on the linear programming was then compared to that by a nonlinear optimization algorithm which was made using GenOpt developed by a national lab in USA. They showed quite similar performances. Therefore, linear programming can be a practical solution to optimal operation scheduling if linear dynamic models are tuned to simulate their real equivalents with reasonable accuracy.

영양플러스 사업 효과의 지속성에 대한 연구 - 포항지역을 중심으로 - (A Study of the Sustainability of NutriPlus Program Effect - in Pohang Area -)

  • 강지혜;류호경
    • 대한지역사회영양학회지
    • /
    • 제16권2호
    • /
    • pp.206-214
    • /
    • 2011
  • This study was conducted to investigate the effect of the NutriPlus+ Program and to observe how the improved statuses were maintained after the program's termination. The subjects were infants and their parents, who have participated in the NutriPlus+ Program conducted by South Healthcare Center in Po-hang for longer than six months, during the period 2007 - 2010. The survey was conducted with questionnaires, and scores were tabulated from each question. After the intervention of the program, scores representing degrees of nutrition knowledge and nutrition attitude increased. The rate of nutritional risk by anthropometric measurement decreased, and the prevalence rate of anemia was significantly decreased as well. The number of subjects lacking any nutrients, except for iron and vitamin C, decreased, which indicates that the NutriPlus+ Program was effective. After enough time had passed after the intervention's completion; however, the scores of nutrition knowledge and nutrition attitude decreased. The number of subjects with low height and weight (proportional to their age) relatively decreased, and the prevalence rate of anemia increased slightly. The number of subjects lacking in energy and calcium consumption increased as well, which indicates that the effect of the NutriPlus+ Program was not maintained after the program's termination.

시뮬레이션 입력값 라이브러리 구축 (The Development of the Simulation Input Library)

  • 강수현;유지석;백승효;조영흠;김광우
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.287-292
    • /
    • 2011
  • It has found that the using library base on criteria of a foreign country resulted in problem of reliability. In order to obtain reliable result, it was necessary to develop the simulation input library based on domestic condition. So, this study was conducted for making the library in accordance with domestic condition when doing simulation modeling about the exist and new buildings. The range of library were consist of material, facility systems, schedules and weather data. And Energy Plus program was used when making library. We hope that the developed library will contribute to reliability when simulating exist and new buildings.

  • PDF