• 제목/요약/키워드: EMTP-ATPDraw

검색결과 62건 처리시간 0.031초

혼합송전계통에서 재폐로 해석을 위한 모델수립 및 개폐과전압해석 (Modeling and Switching Overvoltage Analysis for Reclosing Analysis in Combined Transmission Systems)

  • 임광식;이종범;강지원;정채균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.442-443
    • /
    • 2008
  • This paper describes modeling using the EMTP/ATPDraw for reclosing analysis in 154kV combined transmission systems, and analyzes switching overvoltage. Current transformer established at lead-in area and lead-out area in transmission line and circuit breaker were modeled using TACS in the EMTP/ATPDraw. And also MODELS was constructed by signal processing of the operating reclosing. The simulation was carried out the switching overvoltage according to the length of overhead and underground transmission line, overvoltage between sheath and earth, and voltage between joint boxes.

  • PDF

BESS가 연계된 배전계통에서 새로운 재폐로 기법 (New Reclosing Technique in Distribution System with Battery Energy Storage System)

  • 서훈철
    • 조명전기설비학회논문지
    • /
    • 제30권1호
    • /
    • pp.21-27
    • /
    • 2016
  • The study concerning about the grid connection of the large-capacity battery energy storage system(BESS) is increasing. However, the protection study which is necessary to maintain the reliability of distribution system has been hardly performed. Therefore, this paper analyzes the effect of reclosing among protection issues in distribution system with BESS and proposes the new relcosing method. To verify the proposed method, the BESS, distribution system, and proposed method are modeled by using EMTP/ATPDraw and the various simulations according to the fault clearing time are performed. The simulation results show that the reclosing in distribution system with BESS is successfully performed by proposed method and the operation of BESS is not affected from reclosing.

EMTP/MODELS를 이용한 지중 배전선로의 뇌유도 과전압 및 전류 분석 (Analysis of Lightning-Induced Overvoltage and Current in Buried Underground Distribution Cable using EMTP/MODELS)

  • 서훈철;한준;김철환;최선규;이병성
    • 전기학회논문지
    • /
    • 제61권8호
    • /
    • pp.1077-1082
    • /
    • 2012
  • This paper analyzes the lightning-induced overvoltage and current in buried underground distribution cable. Based on analytical expressions, the lightning-induced overvoltage and current in buried underground distribution cable is calculated by EMTP/MODELS. The modeling is verified by comparing with the results in reference. Also, the type and buried arrangement of cables used in domestic distribution line are modeled by EMTP/ATPDraw. The various simulations according to the type and buried arrangement of cable are performed and the simulation results are analyzed.

지중배전계통에서 뇌서지특성 해석 (Analysis of Lightning Surge in the Underground Distribution Systems)

  • 임광식;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.2219-2220
    • /
    • 2006
  • This paper aims to analyze the overvoltage in underground distribution systems when lightning surge strikes to overhead line. The model is established by EMTP/ATPDraw for actual distribution systems. Simulation is carried out considering variation of parameters such as length and lightning current.

  • PDF

지중배전계통에서 뇌서지특성 해석 (Analysis of Lightning Surge in the Underground Distribution Systems)

  • 임광식;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.587-588
    • /
    • 2006
  • This paper aims to analyze the overvoltage in underground distribution systems when lightning surge strikes to overhead line. The model is established by EMTP/ATPDraw for actual distribution systems. Simulation is carried out considering variation of parameters such as length and lightning current.

  • PDF

지중배전계통에서 뇌서지특성 해석 (Analysis of Lightning Surge in the Underground Distribution Systems)

  • 임광식;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1253-1254
    • /
    • 2006
  • This paper aims to analyze the overvoltage in underground distribution systems when lightning surge strikes to overhead line. The model is established by EMTP/ATPDraw for actual distribution systems. Simulation is carried out considering variation of parameters such as length and lightning current.

  • PDF

지중배전계통에서 뇌서지특성 해석 (Analysis of Lightning Surge In the Underground Dlstrlbutlon Systems)

  • 임광식;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1713-1714
    • /
    • 2006
  • This paper aims to analyze the overvoltage in underground distribution systems when lightning surge strikes to overhead line. The model is established by EMTP/ATPDraw for actual distribution systems. Simulation is carried out considering variation of parameters such as length and lightning current.

  • PDF

지중송전계통에서 저감장치를 이용한 시스 순환전류 저감방안에 관한 연구 (A Study on the Reduction Methods of Sheath Circulating Current using the Reduction Equipment in Underground Transmission Systems)

  • 강지원;양해원
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권9호
    • /
    • pp.474-481
    • /
    • 2002
  • Sheath circulating current is increased in the change of sheath mutual impedance which is caused by unbalanced cable system, and different section length between joint boxes. If excessive current flows in sheath, sheath loss which is reduced the transmission capacity is produced. Recently, excessive sheath circulating current was partially measured in underground cable systems of KEPCO. Accordingly, actual schemes to reduce excessive sheath circulating current are urgently required for installed cable system as well as newly-installing cable systems. This paper describes the relation analysis of sheath circulating current and burying types. And also, various schemes to reduce excessive circulating current using EMTP/ATPDraw and applicable schemes are proposed through a detailed analysis regarding cable systems by considering various electrical and environmental factors. It is evaluated that the proposed reduction schemes can be effectively applied to reduce the excessive sheath circulating current with the minimized electrical problems. And reduction effect is Proved with sheath circulating current reduction equipment.

IEC60947-4에 따른 전자개폐기 전기적 수명시험설비의 과도현상을 고려한 SCR최적 정격선정에 대한 연구 (The transient analysis for choosing the optimal SCR ratings of AC3 utilization category testing equipment used for electrical durability test for magnetic switch)

  • 류행수;김갑동;한규환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.354-356
    • /
    • 2004
  • This paper is the transient analysis for choosing the optimal SCR ratings of AC3 utilization category testing equipment(AC3 TE) used for electrical durability test for magnetic switch according to IEC60947-4 Annex B by utilizing EMTP -ATPDraw. Magnetic contactor closes and opens the motor load with ON/OFF switch of electronic contactor. It is also used for protecting and controlling the load. Magnetic contactor detects the over-current flow in the load with a over-current relay and disconnects the load by opening its control power. The key cost of AC3 TE is the SCR ratings. The more decreases SCR ratings, the more decreased the cost is, but it is impossible to ensure the reliability. On the other hand, the more increases SCR ratings, the more increased the cost is. Thereupon, in this paper after the testing circuit is simulated by using EMTP-ATPDraw the SCR ratings will be applied in order to guarantee the testing reliability of PT&T(Power Testing and Technology institute in LG Industrial Systems Co.,Ltd.).

  • PDF

지중송전계통에서 절연접속함 위치 및 접지방식 변경의 효용성 평가 (Effectiveness Evaluation According to Change of IJ Joint Box Location and Grounding System in Underground Transmission System)

  • 고광만;이종범
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.247-253
    • /
    • 2015
  • Dielectric breakdown accidents have been mainly occurred in the vicinity of service entrance section in underground power transmission systems. One cause among them is due to the excessive component value of sheath located around service entrance of cable. In this paper, as one of the alternative to prevent these accidents, the change of cross bond grounding system and the location change of IJ(Insulation Joint) are suggested. Also, to evaluate effectiveness of this changing system, circulating current and induced voltage of sheath were analyzed in steady and transient state. By comparison of the analytical results for the several possible changing systems, a grounding system and location of IJ which has the smallest sheath component values is proposed. In this paper, analysis to evaluate the proposed system is carried out by EMTP/ATPDraw. It can be used as a valuable operational material to prevent accident of the service entrance section in underground power transmission system.